First Sensor APD Data Sheet First Sensor APD Data Sheet
Part Description AD800-8 TO Part Description AD800-8 TO
Order # 500947 Order # 500947
Version 20-06-11 Version 20-06-11
Quantum efficiency (23 °C) Capacitance as of reverse bias (23 °C)
Multiplication as of bias (23 °C) Dark current as of bias (23 °C)
• For high gain applications bias voltage should be temperature compensated
• Please consider basic ESD protection while handling
• Use low noise read-out - IC
• For further questions please refer to document "Instructions for handling and processing"
Small quantities: Foam pad, boxed (12 cm x 16.5 cm)
Disclaimer: Due to our strive for continuous improvement, specifications are subject to change within our PCN policy according to JESD46C.
European, International Sales:
sales.opto@first-sensor.com sales.us@first-sensor.com
• For low light level applications blocking of ambient light should be used
• Current should be limited by a protecting resistor or current limiting - IC
0,0
20,0
40,0
60,0
80,0
100,0
400 450 500 550 600 650 700 750 800 850 900 950 100010501100
0
10
20
30
40
50
60
70
80
90
100
010 20 30 40 50 60
1
10
100
1.000
20 30 40 50 60 70 80 90 100 110 120 130 140 150
1,0E-11
1,0E-10
1,0E-09
1,0E-08
20 30 40 50 60 70 80 90 100 110 120 130 140 150
Diode, protective circuit
Read-out circuit or
f.e. 50 Load resistance
min. 0,1 µF,
closest to APD
Current limiting resistor