CSM_XS5_DS_E_13_2
1
Round Water-resistant Connectors (M12 Smartclick)
XS5
Round Water-resistive Smartclick
Connectors That Reduce Installation Work
A newly developed lock mechanism that is compatible with round M12 connectors.
Simply insert the Connectors, then turn them approximately 1/8 of a turn to lock.
A positive click indicates locking.
Features the same degree of protection (IP67) as M12 connectors.
A full line-up of models is planned.
Connectors with Cables are UL approved.
Refer to Safety Precautions on page 24.
Ratings and Specifications
*1. Only XS5C/G (IDC models)
*2. Refer to product specifications for details.
Rated current 4 A
Rated voltage 250 VDC
Contact resistance (connector) 40 mΩ max. (20 mV max., 100 mA max.)
Insulation resistance 1,000 MΩ min. (at 500 VDC)
Dielectric strength (connector) 1,500 VAC for 1 min (leakage current: 1 mA max.)
Degree of protection IP67 (IEC60529)
Insertion tolerance 50 times min.
Lock strength Tensile: 100 N/15 s, Torsion: 1 N·m/15 s
Cable holding strength Tensile: 100 N/15 s, Torsion: 1 N·m/15 s (for cable diameter of 6 mm) *2
Lock operating force 0.1 to 0.25 N·m
Ambient operating temperature range 25 to 70°C
Ambient humidity range 20% to 85%
Number of pressure-weld repairs *1 10 times max. (Limited to the same external diameter and wire diameter.)
XS5
2
Materials and Finishes
*Only plug
Connector Pinout Diagram (from Mating Side)
Connection Combinations
Item
Model XS5F/H/W XS5R XS5M/P XS5C/G
(Crimping, Soldering)
XS5C/G
(Screw-on)
XS5C/G
(IDC models)
Contacts
Material Phosphor bronze Phosphor bronze
or Brass Phosphor bronze Brass Phosphor bronze
or Brass Phosphor bronze
Finish Nickel base, 0.4-μm gold plating Nickel base, 0.15-
μm gold plating
Fixtures Nickel-plated zinc alloy
Fixtures (Lock) * Stainless
Pin block PBT resin (UL94V-0)
O-ring Rubber
Overmolding/Cover Soft PBT resin (UL94V-0) --- PBT resin (UL94V-0)
Cable
Fire-retardant,
Robot cable
UL AWM2464 CL3, 6 mm dia.,
AWG20 (0.5mm2)
Structure: 0.08 mm/110 wires
---
Oil-resistant
polyurethane
cable
6 mm dia.
AWG20 (0.5mm2)
Structure: 0.12 mm/45 wires
---
Spatter-resis-
tant Cable
6.6 mm dia.
AWG20 (0.5mm2)
Structure: 0.08 mm/100 wires
---
Seal resin --- Epoxy resin
(UL94V-0) ---
Power supply wires
--- UL1007 AWG20 ---
Item No. of poles 4 poles
DC type
Male (plug) contacts
Female (socket) contacts
1
2
3
4
2
1
4
3
is a registered trademark of the OMRON Corporation.
OMRON model No.
Smartclick Plug Connectors M12 Plug Connectors
XS5H, XS5G, XS5W (plug side),
XS5R (plug side), XS5M
XS2H, XS2G, XS2W (plug side),
XS2R (plug side), XS2M
Smartclick Socket
Connectors
XS5F, XS5C, XS5W (socket side),
XS5R (socket side), XS5P
M12 Socket
Connectors
XS2F, XS2C, XS2W (socket side),
XS2R (socket side), XS2P ❍❍
: Connected by twisting.
: Connected by screwing.
Note: The XS@M and XS@P cannot mate with each other.
XS5
3
XS5W Connectors Connected to Cable, Socket and Plug on Cable Ends
Dimensions (Unit: mm)
Note: Oil-resistant Polyurethane Cables (XS5W-D42@-@81-P) and Spatter-resistant Cable (XS5W-D421-@81-SA) have black covers.
Fire-retardant, Robot cable (XS5W-D42@-@81-F) have warm gray covers.
Fire-retardant, Robot cable XS5W-D42@-@81-F
Oil-resistant Polyurethane Cable XS5W-D42@-@81-P
Spatter-resistant Cable XS5W-D421-@81-SA
L (Cable length)
40.7 44.7
M12×1
14.9 dia. 14.9 dia.
Straight/straight
L (Cable length)
32.3
28.3
M12×1
14.9 dia.
14.9 dia.
Angled/angled
L (Cable length)
28.3
44.7
M12×1
14.9 dia.
14.9 dia.
Angled/straight
1
2
3
4
1
2
3
4
Pin No.
Brown
White
Blue
Black
Cable color of
core sheath
Wiring Diagram for 4 Cores
L (Cable length)
32.3
40.7
M12×1
14.9 dia.
14.9 dia.
Straight/angled
XS5
4
Model Number Legend
1. Type
W: Connectors connected to cable, socket and plug
on cable ends
2. Mating Section Form
D: DC
3. Connector Poles
4: 4 poles
4. Contact Plating
2: 0.4-μm gold plating
5. Cable Connection Direction
1: Straight/straight
2: Angled/angled
3: Straight (Socket)/angled (Plug)
4: Angled (Socket)/straight (Plug)
6. Cable Length
C: 1 m D: 2 m E: 3 m
G: 5 m J: 10m
7. Connections
8: A Brown, B White, C Blue, D Black (Numbers
inside circles are terminal numbers)
8. Connectors on One End/Both Ends
1: Both ends
9. Cable Specifications
F: Fire-retardant, Robot cable
P: Oil-resistant Polyurethane Cable
SA: Spatter-resistant Cable
Ordering Information
XS5W-D42@-@81-@@
83 4
2 6 951 7
Cable specifications Cable
length L (m)
Cable outer
diameter (mm)
Straight/straight Angled/angled Minimum
order UL
Model
Fire-retardant, Robot
cable
1
6
XS5W-D421-C81-F --- 10
Yes
2XS5W-D421-D81-F XS5W-D422-D81-F
53 XS5W-D421-E81-F ---
5XS5W-D421-G81-F XS5W-D422-G81-F
10 XS5W-D421-J81-F --- 1
Oil-resistant Polyure-
thane Cable
2XS5W-D421-D81-P --- 5---5XS5W-D421-G81-P ---
10 XS5W-D421-J81-P --- 1
Spatter-resistant
Cable
26.6 XS5W-D421-D81-SA --- 5---
5XS5W-D421-G81-SA ---
Cable specifications Cable
length L (m)
Cable outer
diameter (mm)
Straight (Socket)/
angled (Plug)
Angled (Socket)/
straight (Plug) Minimum
order UL
Model
Fire-retardant, Robot
cable
26XS5W-D423-D81-F XS5W-D424-D81-F 5Yes
5XS5W-D423-G81-F XS5W-D424-G81-F
XS5
5
XS5F Connector Connected to Cable, Socket on One Cable End
Dimensions (Unit: mm)
Note: Oil-resistant Polyurethane Cables (XS5F-D42@-@80-P) and Spatter-resistant Cable (XS5F-D421-@80-SA) have black covers. Fire-
retardant, Robot cable (XS5F-D42@-@80-F) have warm gray covers.
Model Number Legend
Ordering Information
Fire-retardant, Robot cable XS5F-D42@-@80-F
Oil-resistant Polyurethane Cable XS5F-D42@-@80-P
Spatter-resistant Cable XS5F-D421-@80-SA
Straight
40.7
L (Cable length)
50
30 5
M12 × 1
14.9 dia.
1
2
3
4
Brown
White
Blue
Black
Pin No. Cable color of
core sheath
Wiring Diagram for 4 Cores
L (Cable length)
25.3
28.3
50
30 5
M12×1
14.9 dia.
Angled
XS5F-D42@-@80-@@
83 4
2 6 951 7
Cable specifications Cable length L (m)
Cable outer
diameter (mm)
Straight Connectors Angled Connectors Minimum
order UL
Model
Fire-retardant, Robot cable
1
6
XS5F-D421-C80-F XS5F-D422-C80-F 10
Yes
2XS5F-D421-D80-F XS5F-D422-D80-F
53 XS5F-D421-E80-F XS5F-D422-E80-F
5XS5F-D421-G80-F XS5F-D422-G80-F
10 XS5F-D421-J80-F XS5F-D422-J80-F 1
Oil-resistant
Polyurethane Cable
2XS5F-D421-D80-P XS5F-D422-D80-P 5---5XS5F-D421-G80-P XS5F-D422-G80-P
10 XS5F-D421-J80-P XS5F-D422-J80-P 1
Spatter-resistant
Cable
26.6 XS5F-D421-D80-SA --- 5---
5XS5F-D421-G80-SA ---
1. Type
F: Connector connected to cable,
socket on one cable end
2. Mating Section Form
D: DC
3. Connector Poles
4: 4 poles
4. Contact Plating
2: 0.4-μm gold plating
5. Cable Connection Direction
1: Straight
2: Angled
6. Cable Length
C: 1 m D: 2 m E: 3 m
G: 5 m J: 10 m
7. Connections
8: A Brown, B White, C Blue,
D Black (Numbers inside circles are
terminal numbers.)
8. Connectors on One End/Both Ends
0: One end
9. Cable Specification
F: Fire-retardant, Robot cable
P: Oil-resistant Polyurethane Cable
SA: Spatter-resistant Cable
XS5
6
XS5H Connector Connected to Cable, Plug on One Cable End
Dimensions (Unit: mm)
Note: Oil-resistant Polyurethane Cables (XS5H-D42@-@80-P) and Spatter-resistant Cable (XS5H-D421-@80-SA) have black covers. Fire-
retardant, Robot cable (XS5H-D42@-@80-F) have warm gray covers.
Model Number Legend
Ordering Information
Fire-retardant, Robot cable XS5H-D42@-@80-F
Oil-resistant Polyurethane Cable XS5H-D42@-@80-P
Spatter-resistant Cable XS5H-D421-@80-SA
Cable specifications Cable length L (m)
Cable outer
diameter (mm)
Straight Connectors Angled Connectors Minimum
order UL
Model
Fire-retardant, Robot cable
0.3
6
XS5H-D421-A80-F XS5H-D422-A80-F 10
Yes
1XS5H-D421-C80-F XS5H-D422-C80-F
2XS5H-D421-D80-F XS5H-D422-D80-F 5
5XS5H-D421-G80-F XS5H-D422-G80-F
Oil-resistant
Polyurethane Cable
0.3 XS5H-D421-A80-P XS5H-D422-A80-P 10
---2XS5H-D421-D80-P XS5H-D422-D80-P 5
5XS5H-D421-G80-P XS5H-D422-G80-P
Spatter-resistant
Cable
0.3 6.6 XS5H-D421-A80-SA --- 10 ---
1XS5H-D421-C80-SA ---
L (Cable length)
44.7
50
30 5
M12×1
14.9 dia.
1
2
3
4
Brown
White
Blue
Black
Pin No. Cable color of
core sheath
L (Cable length)
M12×1
50
30 5
32.3
25.3
14.9 dia.
Wiring Diagram for 4 Cores
Angled
Straight
XS5H-D42@-@80-@@
83 4
2 6 951 7
1. Type
H: Connector connected to cable,
plug on one cable end
2. Mating Section Form
D: DC
3. Connector Poles
4: 4 poles
4. Contact Plating
2: 0.4-μm gold plating
5. Cable Connection Direction
1: Straight
2: Angled
6. Cable Length
A: 0.3 m C: 1 m D: 2 m
G: 5 m
7. Connections
8: A Brown, B White, C Blue,
D Black (Numbers inside circles
are terminal numbers)
8.
Connectors on One End/Both Ends
0: One end
9. Cable Specifications
F: Fire-retardant, Robot cable
P: Oil-resistant Polyurethane
Cable
SA: Spatter-resistant Cable
XS5
7
XS5@ Eight-pole Connectors with Cables
Ordering Information
Pins and Cable Lead Colors
Dimensions (Unit: mm)
Panel Cutout
Type Cable specification Cable connection
direction
No. of cable
cores
Cable length L
(m)
Applicable wire
gauge Model
Connector Connected to
Cable, Socket on One End
6.3 mm dia.,
AWG23 (0.25 mm2)
Structure: 0.08 mm/60 wires
Straight 10
2
---
XS5F-D821-DH0-R
5XS5F-D821-GH0-R
10 XS5F-D821-JH0-R
Panel-mounting Plug --- --- --- --- AWG22 to AWG28 XS5M-D827-4
Pin No.
XS5F cable lead colors
ABCDEFGH
White Brown Green Yellow Gray Pink Blue Red
Ratings and Specifications Materials and Finishes
*1. XS5F only.
*2. XS5M only.
Rated current
1.5 A
Rated voltage 36 VDC
Contact resistance 40 mΩ max.
(at 20 mV DC max., 100 mA max.)
Insulation resistance 1,000 MΩ min. (at 500 VDC)
Dielectric strength 1,000 VAC for 1 min
(leakage current: 1 mA max.)
Degree of protection IP67 (IEC 60529)
Insertion tolerance 50 times
Ambient operating temperature range 25 to 70°C
Ambient operating humidity range 20% to 85%
Contacts
Brass/nickel base, 0.4-μm gold plating
Fixtures Nickel-plated zinc alloy *1
Body Nickel-plated zinc alloy *2
Nuts Nickel-plated brass *2
Fixtures (lock) Stainless *2
Contact block PBT resin (UL94V-0), light gray
Cover *1 Soft PBT resin (UL94V-0)
Seal resin *2 Rubber
O-ring*1
L (cable length)
12
3
7
6
8
M12×1
5
4
40.7
(30)
(50)
(5)
14.9 dia.
XS5F-D821-@H0-R Connector Connected to Cable, Socket on One End
Pin No.
(19)
(21.9)
Nut
M12×1
M16×1 Seal resin
3
2.8
Eight, 1 dia
17
20 dia.
35
22.8
8
Resin filling
2
XS5M-D827-4 Front-locking, Panel-mounting Plug
Panel Cutout
Panel thickness (t): 1 to 4
16.1 dia.
+0.1
0
16.1 dia.
+0.1
0
14.1
+0.1
0
XS5
8
XS5G Assembly Connector Plugs
Dimensions (Unit: mm)
XS5G-D418 (IDC Model)
Straight Connectors
66
58
17.5 dia.
14.9
dia.
M12 × 1
XS5G-D4C@ (Crimping Model)
XS5G-D42@ (Soldering Model)
Straight Connectors
14.9 dia.
49.3
14.2 dia.
M12 × 1
XS5G-D42@ (Soldering Model)
Angled Connectors
37.7
14.9 dia.
23
M12 × 1
58.7
16 dia. 20 dia.
14.9 dia.
M12 × 1
XS5G-D@S@ (Screw-on Connectors, Applicable Cable Outer Diameter: 7 or 8 mm)
Straight Connectors
58.7
14 dia. 20 dia. 14.9 dia.
M12 × 1
XS5G-D@S@ (Screw-on Connectors, Applicable Cable Outer Diameter: 3, 4, or 6 mm)
Straight Connectors
39.7
39.6
20 dia.
14 dia.
M12 × 1
14.9 dia.
XS5G-D@S@ (Screw-on Connectors)
Angled Connectors
XS5
9
Ordering Information
*1. Minimum wire diameter: 0.08 mm, Outer diameter of wire covering: 0.7 to 2.6 mm, Material of wire covering: PVC and PE
*2. There are two types of contacts.
Note: XS5G Screw-on Plugs cannot be connected to side by side to the CN1 and CN2 connectors of XS2R or XS5R Y-Joint Sockets/Plugs.
Use one of the above cables. If you do not use one of these cables, there is a possibility that the performance can't be met.
Ask your OMRON representative about selecting a cable of other than above.
No. of
poles
Connection
method
Suitable cable dia.
(mm)
Core conductor size
(mm2)
Suitable sheath
material
Straight Connectors Angled Connectors Minimum
order
Model
4
IDC 3 to 8 mm 0.14 to 0.75 *1
PVC, PE, PUR
XS5G-D418 ---
50
Crimping
6 mm (5 to 6) 0.18 to 0.3
0.5 to 0.75 *2
XS5G-D4C1 ---
4 mm (4 to 5) XS5G-D4C3 ---
3 mm (3 to 4) XS5G-D4C5 ---
Soldering
6 mm (5 to 6)
0.5 max.
XS5G-D421 XS5G-D422
4 mm (4 to 5) XS5G-D423 XS5G-D424
3 mm (3 to 4) XS5G-D425 XS5G-D426
Screw-on
6 mm (5 to 6)
0.18 to 0.75
XS5G-D4S1 XS5G-D4S2
4 mm (4 to 5) XS5G-D4S3 XS5G-D4S4
3 mm (3 to 4) XS5G-D4S5 XS5G-D4S6
8 mm (7 to 8) XS5G-D4S7 ---
7 mm (6 to 7) XS5G-D4S9 ---
5 Screw-on
6 mm (5 to 6) XS5G-D5S1 ---
4 mm (4 to 5) XS5G-D5S3 ---
3 mm (3 to 4) XS5G-D5S5 ---
8 mm (7 to 8) XS5G-D5S7 ---
7 mm (6 to 7) XS5G-D5S9 ---
XS5
10
XS5U (Crimping Pin for XS5G)
Dimensions (Unit: mm)
Ordering Information
Note: Orders are accepted in multiples of the minimum order.
Suitable core size (mm2)Model Minimum order
0.18 to 0.3 XS5U-3121 100
0.5 to 0.75 XS5U-3122
XS5U-312@
Plug Pin
2.3 dia.2 dia.
C dia.
1.5
1 dia.
B
Slit
A
* A special tool must be used for crimping. For details, refer to page 18.
Dimensions
Model Suitable core
size (mm2)
Dimension (mm) No. of
slits
ABC
XS5U-3121 0.18 to 0.3 22.6 6.1 0.8 1
XS5U-3122 0.5 to 0.75 22.7 6.2 1.3 0
XS5
11
XS5C Assembly Connector Sockets
Dimensions (Unit: mm)
XS5C-D418 (IDC Model)
Straight Connectors
62.4
54.4
17.5 dia.14.9 dia.
M12 × 1
XS5C-D4C@ (Crimping Model)
XS5C-D42@ (Soldering Model)
Straight Connectors
M12 × 1
43.4
14.9 dia. 14.2 dia.
XS5C-D4C@ (Crimping Model)
XS5C-D42@ (Soldering Model)
Angled Connectors
M12 × 1
31.8
14.9 dia.
23
54.9
20 dia. 14.9 dia. 16 dia.
M12 × 1
XS5C-D@S@ (Screw-on Connectors, Applicable Cable Outer Diameter: 7 or 8 mm)
Straight Connectors
54.9
20 dia. 14.9 dia. 14 dia.
M12 × 1
XS5C-D@S@ (Screw-on Connectors, Applicable Cable Outer Diameter: 3, 4, or 6 mm)
Straight Connectors
14.9 dia.
35.9
39.6
14 dia.
20 dia.
M12 × 1
XS5C-D@S@ (Screw-on Connectors)
Angled Connectors
XS5
12
Ordering Information
*1. Minimum wire diameter: 0.08 mm, Outer diameter of wire covering: 0.7 to 2.6 mm, Material of wire covering: PVC and PE
*2. There are two types of contacts.
Note: Use one of the above cables. If you do not use one of these cables, there is a possibility that the performance can't be met.
Ask your OMRON representative about selecting a cable of other than above.
No. of
poles
Connection
method
Suitable cable dia.
(mm)
Core conductor size
(mm2)
Suitable sheath
material
Straight Connectors Angled Connectors Minimum
order
Model
4
IDC 3 to 8 mm 0.14 to 0.75 *1
PVC, PE, PUR
XS5C-D418 ---
50
Crimping
6 mm (5 to 6) 0.18 to 0.3
0.5 to 0.752 *2
XS5C-D4C1 XS5C-D4C2
4 mm (4 to 5) XS5C-D4C3 XS5C-D4C4
3 mm (3 to 4) XS5C-D4C5 XS5C-D4C6
Soldering
6 mm (5 to 6)
0.5 max.
XS5C-D421 XS5C-D422
4 mm (4 to 5) XS5C-D423 XS5C-D424
3 mm (3 to 4) XS5C-D425 XS5C-D426
Screw-on
6 mm (5 to 6)
0.18 to 0.75
XS5C-D4S1 XS5C-D4S2
4 mm (4 to 5) XS5C-D4S3 XS5C-D4S4
3 mm (3 to 4) XS5C-D4S5 XS5C-D4S6
8 mm (7 to 8) XS5C-D4S7 ---
7 mm (6 to 7) XS5C-D4S9 ---
5 Screw-on
6 mm (5 to 6) XS5C-D5S1 ---
4 mm (4 to 5) XS5C-D5S3 ---
3 mm (3 to 4) XS5C-D5S5 ---
8 mm (7 to 8) XS5C-D5S7 ---
7 mm (6 to 7) XS5C-D5S9 ---
XS5
13
XS5U (Crimping Pin for XS5C)
Dimensions (Unit: mm)
Ordering Information
Orders are accepted in multiples of the minimum order.
Suitable core size (mm2)Model Minimum order
0.18 to 0.3 XS5U-2221 100
0.5 to 0.75 XS5U-2222
XS5U-222@
Socket Pin
Slit
2.3 dia.2 dia.
C dia.
1.5
B
A
* A special tool must be used for crimping. For details, refer to page 18.
Dimensions
Model Suitable core
size (mm2)
Dimension (mm) No. of
slits
A B C
XS5U-2221 0.18 to 0.3 16.7 6.1 0.8 1
XS5U-2222 0.5 to 0.75 16.8 6.2 1.3 0
XS5
14
XS5R Y-Joint Plug/Socket Connectors
Dimensions (Unit: mm)
Ordering Information
Note 1. Ask your OMRON representative about other specifications.
2. XS2G/XS5G Assembled Connectors with screw connections cannot be connected to both CN1 and CN2 at the same time.
Cable Connector Cable length (m) Model Minimum order
With cable
Connectors on both cable
ends
0.5 XS5R-D426-B11-F 10
1XS5R-D426-C11-F
2XS5R-D426-D11-F
5
3XS5R-D426-E11-F
Connector on one cable
end
2XS5R-D426-D10-F
5XS5R-D426-G10-F
Cable Connector Cable length (m) Model Minimum order
With no cable Y-Joint Plug/Socket XS5R-D426-1 10
XS5R-D426-5
XS5R-D426-@11-F
Connectors on Both Ends (Y-Joint Plug/Socket)
1
2
3
44
3
2
1
1
2
3
4
CN2
CN1
1
43
2
1
43
2
1
43
2
1
43
2
1
4 3
2
1 1
4 4 3 3
2 2
1
4 3
2
1
4 3
2
45.5
4.6 dia.
18.0
35.0
CN1
CN2
15.0
Blue marking 8.5
13.6
L
44.7
Plug
Socket
M12 × 1
M12 × 1
Wiring Diagram
XS5R-D426-@10-F
Connectors on One Cable End (Y-Joint Socket)
1
43
2
1
43
2
1
43
2
1
43
2
18.0
15.0
35.0
CN1
CN2
Blue marking
45.5
4.6 dia.
30
50
5
8.5 13.6
L
SocketM12 × 1
1
2
3
4
1
2
3
4
Black
Blue
White
Brown
CN2
CN1
Wiring Diagram
4
3
2
1
4
3
2
1
4
3
2
1
4
3
2
1
4
3
2
1
4
3
2
1
CN2
CN1
CN0
CN2
CN1CN0
1
4 3
2
1
4 3
2
58.3
27
4.5 dia.
CN2
(37) 18
15
CN1
CN0
Blue marking
7
24.5
12.5
SocketM12 × 1
Plug
M12 × 1
Wiring Diagram
XS5R-D426-1 XS5R-D426-5
XS5R-D426-@
Y-Joint Plug/Socket without Cable
XS5
15
XS5P Panel-mounting Sockets
Dimensions (Unit: mm)
Panel Cutout
Ordering Information
XS5P-D426-4 Rear-locking Socket with Solder Cup Pins XS5P-D526-4 Rear-locking Socket with Solder Cup Pins
XS5P-D427-4 Front-locking Socket with Solder Cup Pins XS5P-D527-4 Front-locking Socket with Solder Cup Pins
Type No. of poles Lock Cable length (m) Model Minimum order
With cable 4 Rear lock 0.5 XS5P-D426-5 10
Front lock XS5P-D427-5
Type No. of poles Lock Applicable wires Model Minimum order
Solder cup
pins
4Rear lock
AWG20 to AWG28
XS5P-D426-4
50
Front lock XS5P-D427-4
5Rear lock XS5P-D526-4
Front lock XS5P-D527-4
23
4
120
White
Brown
Black
Blue
18
500
22.1
11.9
2.5
14.6 dia.
PG9
2.8
M12×1
17
18
20
10
XS5P-D426-5
Rear-locking Socket Connected to Wires
Wiring
Wire Specifications
Pin number Color
1Brown
2White
3Blue
4Black
Item Specification
Specification UL1007
Nominal size AWG20
Config-
uration
Number of
wires 21
Wire diameter 0.18
Standard outer
diameter 1.8
2
3
4
1
Blue
Brown
Black
White
18
17
500
22.1
10.5 2.5
13.9 dia.
PG9 2.8
M12×1
18
21
20
10
XS5P-D427-5
Front-locking Socket Connected to Wires
Resin filling
4, 1.3 dia.
18
PG9
Nut
2.5 11.9
2.8
22.1
3.5
M12×1
17 18
20
14.6 dia.
14.6 dia.
2.5 11.9
22.1
PG9
Nut
2.8
3.5
5.5
18
17
Resin filling
185, 1.3 dia.
20
M12×1
PG9
1817
20 18
Resin filling
4, 1.3 dia.
13.9 dia.
Nut
2.8
3.5
2.510.5
22.1
M12×1
PG9
Nut
1817
20 18
Resin filling
5, 1.3 dia.
13.9 dia.
2.8
3.5
5.5
2.510.5
22.1
M12×1
Panel Cutout Dimension
Panel thickness = 1 to 4 mm
15.3
+0.1
0
dia.
Note 1. The panel cutout dimension is the same for Front-locking and Rear-locking Sockets.
2. Rotational positioning is not possible for connector rotation.
XS5
16
XS5M Panel-mounting Plugs
Dimensions (Unit: mm)
Panel Cutout
Ordering Information
XS5M-D426-4 Rear-locking Plug with Solder Cup Pins XS5M-D526-4 Rear-locking Plug with Solder Cup Pins
XS5M-D427-4 Front-locking Plug with Solder Cup Pins XS5M-D527-4 Front-locking Plug with Solder Cup Pins
Type No. of poles Lock Cable length (m) Model Minimum order
With cable 4 Rear lock 0.5 XS5M-D426-5 10
Front lock XS5M-D427-5
Type No. of poles Lock Applicable wires Model Minimum order
Solder cup
pins
4Rear lock
AWG20 to AWG28
XS5M-D426-4
50
Front lock XS5M-D427-4
5Rear lock XS5M-D526-4
Front lock XS5M-D527-4
White
Brown
Blue
Black
2
3
4
1
20
18
500
22.8
10
2.8
PG9
2.8
M12×1
18
17
20
10
XS5M-D426-5
Rear-locking Plug Connected to Wires
Wiring
Wire Specifications
Pin number Color
1Brown
2White
3Blue
4Black
Item Specification
Specification UL1007
Nominal size AWG20
Configu-
ration
Number of wires 21
Wire diameter 0.18
Standard outer
diameter 1.8
1
4
3
2
M12×1
20
1818500
PG92.8
22.8
82.8
17
20
10
White
Brown
Blue
Black
XS5M-D427-5
Front-locking Plug Connected to Wires
PG9
17
1818
20
Resin filling
4, 1.3 dia.
M12×1
Nut2.8
3.5
2.810
22.8
M12×1 PG9
Nut18
17
18
20
Resin filling
5, 1.3 dia.
2.8
3.5
5.5
2.810
22.8
1818
20 17
Resin filling
4, 1.3 dia.
PG9
M12×1
Nut2.8
3.5
2.88
22.8
1818
20 17
Resin filling
5, 1.3 dia.
M12×1
PG9
Nut
2.8
3.5
5.5
2.88
22.8
Panel Cutout Dimension
Panel thickness = 1 to 4 mm
15.3+0.1
0 dia.
Note 1. The panel cutout dimension is the same for Front-locking and Rear-locking Sockets.
2. Rotational positioning is not possible for connector rotation.
XS5
17
Connector Covers
Model Minimum order Material Suitable connector
Model Mounting portion
XS2Z-11 50 Brass/nickel plated XS5G/XS5H/XS5M/XS5R/XS5W/
XS2G/XS2H/XS2M/XS2R/XS2W M12 male screw
XS5Z-11 PBT XS5C/XS5F/XS5P/XS5R/XS5W/XW3D M12 female screw
M12 × 1
XS2Z-11 M12 male screw
Water-resistive Covers
XS2Z-11
XS5Z-11 M12 female screw
XS5Z-11 The Water-resistive Cover ensures IP67.
When mounting the Water-resistive Cover
to a Connector, be sure to apply a torque
range between 0.39 and 0.49 N·m to
tighten the Water-resistive Cover.
XS5Z-11 is Smart click mechanism. There's
no need to keep track of locking torque.
Model Minimum order Material Suitable connector
Model Mounting portion
XS2Z-13
50 Rubber/black
XS5G/XS5H/XS5M/XS5R/XS5W/
XS2G/XS2H/XS2M/XS2R
M12 male screw
XS2Z-14
XS5C/XS5F/XS5P/XS5R/XS5W/
XS2C/XS2F/XS2P/XS2R/XS2W/
XW3B/XW3D
Pin block (female pins)
XS2Z-15 M12 female screw
XS2Z-13 M12 male screw
Dust Covers
XS2Z-13
XS2Z-15 XS2Z-14 M12 female screw
Pin block (female pins)
XS2Z-15/XS2Z-14 The Dust Cover is for dust prevention and
does not ensure IP67 degree of protection.
When mounting the Dust Cover to a
connector, be sure to press the Dust Cover
onto the Connector until the Connector is
fully inserted into the Dust Cover.
Model Material Applicable connector
XS2Z-31 Silicone rubber/black XS5F/XS5H/XS5W/
XS2F/XS2H/XS2W
XS2Z-31 M12 female screw (thread bracket)
Pin block (female contact)
Sputter Protective Cover
XS2Z-31 The Sputter Protective Cover protects the
connector from weld sputter.
Make sure it covers the entire connector.
XS5
18
Tools
Use the Crimp Tool to crimp a cable core to the XS5U or XS2U
Crimping Pin used with the XS@C or XS@G Crimping Connector.
The XY2F-0002 Crimp Tool is DMC's AFM8 (M22520/2-01).
Mount the XY2F-0003 Locator (sold separately) to the locator
guide of the Crimp Tool with a screw provided with the XY2F-0003
Locator.
Extraction Procedure
(1) Disconnecting Components
Disconnect all components on the cap side from the cover.
(2) Extracting Pin Block
Insert the claws of the Tool into the four holes of the cover.
Make sure that the pin block is outside the Tool.
Press the Tool so that the guides of the Tool are in close contact.
Then pull the pin block straight.
Precaution for Safe Use
The pin block must not be extracted from the same Connector
more than 3 times, otherwise the proper degree of protection of the
pin block or Connector will not be maintained.
Crimp Tool
XY2F-0002
Locator
XY2F-0003
5
4
3
2
1
8
7
6
R
A
I
S
E
T
O
R
O
T
A
T
E
SEL.
NO.
P
U
S
H
P
O
S
I
T
I
O
N
E
R
A
N
D
R
O
T
A
T
E
9
0
°
T
O
I
N
S
T
A
L
L
R
O
T
A
T
E
9
0
°
T
O
I
N
S
T
A
L
L
T
oo
l
i
n open pos
i
t
i
on
Tool in closed
position
XY2F-0002
Crimp Tool
XY2F-0003
Lo
ca
tor
Selector dial
(Set to 8.)
Locator guide
Model
XY2F-0002
XY2F-0003
Pin-block Extraction Tool
XY2F-0001
Use this tool to extract a Pin Block from the covers in order to make
wiring changes or corrections after the cover has been mounted to the
pin block for Connector Assemblies (XS@C/XS@G, soldering/
crimping). Model
XY2F-0001
Pin block Cover Rubber
bushing
Cable
clamp
Cap
Holes
Claws
Tool
Pin block
Guide
Cover Cover
Pin block
Guide
Extracting
direction
XS5
19
Assembly Procedure for XS5C/XS5G (IDC models) Connector Assemblies
(1) Preparations (Make sure they are all at hand.)
(2) Dressing the cable end
Peel covering of a cable.
(3) Choose the waterproof bushing
Choose the waterproof bushing type according to the cable
size.
<External diameter of cable: In case of 3 to 5 mm>
Use the cap unit in the delivery state.
<External diameter of cable: In case of 5 to 8 mm>
When using, pick tab both sides of the waterproof bushing
with a tab and pull it out in the direction of an arrow.
Note: When it isn't necessary to pull out bushing, do not pull a tab or pull out
bushing carelessly. Do not insert the pulled-out bushing again.
(4) Cable insertion
Insert a cable in the cap unit.
(5) Wiring
Confirm the terminal number indication*1 of a IDC
(Insulation Displacement Contact) cover, insert a core wire
in each wire guide according to the terminal number and
push in to the lowermost part of a core wire storage part.
(6) Processing the core wire end
Cut the end part of each core wire with nippers. Cutting the
core wire end in the range of cut-area of figure.
Note: Please be careful not to cut the boss.
(7) Assembling the Contact block
Insert the cap unit core wire end processing has completed
in a contact block.
Use a mark of a housing and an arrow of a IDC cover, as
a guideline of alignment. The location of the arrow is the
side of the terminal No.1.
Note: Confirm that the color of the housing and the IDC cover is same before
insertion.
(8) Tightening up the cap
After inserting the cap unit and tightening a screw up lightly
by hand, screw up the cap by a tool of a spanner or wrench
(size 15 mm).*2
When a gap between a mold cover of contact block and a
cap disappeared assembly and wire connection has
completed.
Note 1. When the operation has completed, mark of cap comes into the
square of the indicator formed into a mold cover ( ), so also use
it as guideline to know to complete.
2. Avoid tightening a cap up beyond the completion position. It may cause
damage.
(9) Final checking
When the connector has been assembled, make sure the
line insulation is as specified.
External diameter of
applicable cable Conductor cross section
3 to 8 mm 0.14 to 0.75mm2 / AWG26 to 18
Cap unit
Contact block IDC cover Cap
approx. 40 mm Cable
(Not required.)
waterproof bushing with a tab
* Insert fully until a cable doesn't
enter any more.
* It's shown by a figure in case of
cable external diameter 3 to 5
mm.
Core wire storage part
Wire guide part
Core wire
*1. Terminal No.1: Brown
Terminal No.2: White
Terminal No.3: Blue
Terminal No.4: Black
Note: There is a difference in a
storing state depending
on core wire diameter.
Terminal number
indication surface
Boss
Cut-area
Core wire
Housing
Pink marking
* Color : Housing/ IDC cover
XS5C : Gray
XS5G : White
completion position
*2. When screwing up the cap by large size tool,
it may cause damage.
completion position
Mold cover
Fixture
XS5
20
Cap unit removal
When releasing wire connection, remove the cap unit in the
opposite procedure of assembly work. [ from (8) to (7) ]
Note 1. The core wire remain connected to the IDC connection part rarely. In
that case, remove core wire end part to the vertical direction by
tweezers etc. Do not touch the IDC contact directly at that time.
2. When IDC cover was left on the housing side, remove it by pulling a
cable. In case IDC cover has been removed by holding strongly and
pulling, it may cause damage.
Cable removal
When removing the cable from the cap unit,
pull the cable to the opposite direction of
assembly work procedure (4). When tip of
the core wire end has been pushed lightly
into the IDC cover by tweezers etc, cable
removal becomes easy.
Repair work
When connecting the wire again, do assembly (repair work)
according to assembling procedure from (1) to (8).
Note 1. In case of repair, use a cable of the same diameter and a core wire of
the same diameter. The number of times of repair wire connection is
maximum 10 times.
2. When doing a repair, work after enough removing the foreign substance
and moisture adhering to a connector. Be careful so that the foreign
substance and moisture do not enter the wire connection part. It may
cause short-circuit etc.
Repair work procedure
XS5
21
Assembly Procedure for XS5C/XS5G (Crimping/Soldering/Screw-on models)
Connector Assemblies
(1) Connector and Cable External Diameters
Connectors for 8 ,7 ,6 , 4 , and 3 mm diameter Cables (i.e., Cables
that are 7 to 8, 6 to 7, 5 to 6, 4 to 5, and 3 to 4 mm in diameter
respectively) are available. When assembling a Connector used
with a cable, make sure that the external diameter of the Connector
is suited to that of the cable.
A watertight bushing for 6/7 mm diameter Cable has no stripe, that
for 8/4 mm diameter Cable has a single stripe, and that for 3 mm
diameter Cable has two stripes.
(2) Component Insertion
As shown in the above illustration, connect the above components
to the Cable with its end processed.
(3) Wiring (Processing Cable Ends)
Strip 10 mm of the Cable sheath and 4 mm of each core.
Before soldering cores and solder cup pins together, solder-coat
each of them.
The following conditions are recommended for soldering each
solder cup pin.
Soldering temperature: 350±5°C
Soldering period: 3±1 s
The length marked *A should be 6.5 mm max., otherwise the
proper degree of protection of the connector will not be maintained.
Strip 14 mm of the Cable sheath and 4 mm of each core.
Make sure that each core is not damaged and its end strands are
not spread out.
Mount the XY2F-0003 Locator to XY2F-0002 Crimping Tool, both
of which are sold separately, and set the selector dial of the
Crimping Tool to 8.
After mounting the crimping pins to the Locator, fully insert the
cores to the crimping pins.
Squeeze the handle of the Crimp Tool to press-fit the cores to the
crimping pins.
(Squeeze the handle firmly until the handle automatically returns to
the release position.)
After press-fitting the cores to the pins, insert the pins into the pin
clamp as shown in the illustration. Then make sure that the lead
colors correspond to the pin clamp numbers that are identical to
the connector pin numbers.
Crimping/Soldering Connectors
Screw-on Connectors
Cover
Watertight
bushing Cable
clamp Cap
Cover
Ring (Angled models only) *
Watertight
bushing
Cable clamp Cap
Straight Connectors
Angled Connectors
* A ring is not required for Screw-on Connectors.
Cover
Cover
Watertight bushing
Watertight
bushing
Cable clamp
Cable clamp
Cap
Cap
Ring *1
(*2 )
Confirm that you have all of the required parts.
Insulation caps and insulation tubes are included with
five-pole Connectors (XS2C-D5S@ and XS2G-D5S@).
*1. Rings are not required with 7-mm and 8-mm cables.
*2. Insert the waterproof bushing for 7-mm and 8-mm
cables in the direction shown in the diagram.
Soldering Connectors
Crimping Connectors
46
6
±0.5
*A
410
0
4
Crimping
Pin clamp Press
1 to 1.5
Wiring
XS5
22
Tentatively insert the pins to the pin block holes so that the key on
the pin block will coincide with the key groove on the pin clamp.
Then insert the cable along with the pin clamp.
Loosen the screws on pins 1 to 4 and insert the cores according to
the pin numbers.
Use the dedicated Screwdriver (XW4Z-00B)* and tighten the
screws securely so that the cores do not pull out (tightening torque:
0.15 to 0.2 N·m).
Five-pole Connectors
Strip the cable sheath for a total of 15 mm and strip the core
covering for 8 mm for the core to connect to pin 5.
Connect the core to pin 5 (in the center) first.
Insert the core from the side of the hold with the tab and tighten the
screw securely (tightening torque: Pins1 to 4: 0.15 to 0.2 N·m,
Pins5: 0.03 to 0.05 N·m), and then cut off the excess wire with wire
cutters.
Bend the cable as shown below, attached the enclosed insulation
cap, and then strip the other cores.
Connect the cores to pins 1 to 4.
Connecting Shielded Cables to Five-pole Connectors
Place the insulation tub on the drain line of the shield and connect
it to the terminal.
Tighten the screw and then check visually to see if there is
insulation between the cores.
* When tightening the screws, use the dedicated XW4Z-00B
Screwdriver that matches with the screw-slot dimensions.
(4) Inserting Pin Block
Mount the cover to the pin block so that the triangle mark on the pin
block will coincide with the triangle mark on the cover.
If the cover is used for an Angled model, the relationship between
the position of the polarity key on the engaged side and cable
connection direction will be determined by the direction in which
the positioning key is inserted into the cover, which can be rotated
by 90°.
Fully insert the positioning key until the positioning key is hidden by
the casing.
Screw-on Connectors
Pin Block Pin Clamp
Key groove Key groove
Key XS5C use XS5G use
6
±0.5
Insertion
8
12
12
±0.5
Cable End Processing
Four-pole Connectors
87
8
12
Conductors for
pins 1 to 4
Conductors for
pin 5
Screw
Dedicated
screwdriver
Dedicated
screwdriver
Screw
Ta b
Insulation cap
Insulation tube
Drain line
XW4Z-00B
Screwdriver
Lock spring O-ring
Triangle mark
Positioning key
(triangle mark)
Polarity key
Pin Block
(Soldering Model)
Cover
(Straight Model)
(Crimping Model) (Angled Model)
XS5
23
Align the triangular marks on the pin block and cover and insert the
pin block into the cover.
Press them together firmly (0.39 to 0.49 N·m) until the pin block
does not come out of the cover.
(5) Mounting Cap
After mounting the cover to the pin block and the cover snaps into
place, tighten the cap securely by hand within a torque of 0.39 and
0.49 N·m.
Note: If the cap is not tighten securely enough, the degree of
protection (IP67) may not be maintained or vibration may
cause the cap to become loose. Do not tighten the cap with
pliers or similar tools; they may damage the cap.
After fully tightening the cap, length A should be approximately one
of the following according to the cable external diameter and the
Connector model.
(6) After Assembly
Confirm the insulation between cores after completing assembly.
Recommended Cables
When connecting a commercially available cable to a connector
assembly, use a cable with an outside diameter of 3 to 6 mm and core
sizes of 0.18 to 0.75 mm2 for crimping connectors and 0.5 mm2
maximum for soldering connectors.
Connector Arrangement
For safety, when constructing a connection system between a Sensor
and panel with a connector, make sure that the connector plug is on
the Sensor side and the connector socket is on the panel side (i.e.,
the female pins are located on the power-supply side).
Connecting the XS5
1. Connecting the XS5 Plug and Socket
Align the projection on the plug cover with the polarity key on the
socket, then insert the plug all the way in.
Hold the knurled socket grip, then insert the projection on the plug
into the groove of the socket.
Turn the knurled grips of the socket clockwise approximately 45
degrees in respect to the plug. A click will indicate that the
Connectors are locked. The locking condition can also be
confirmed by the alignment marks on the plug and socket.
2. Connecting the XS5 and XS2
Align the projection on the plug cover with the polarity key on the
socket, then insert the plug all the way in.
In the same way as when connecting two XS2 Connectors, screw
the knurled grip in the clockwise direction.
Use your fingers to tighten the Connectors sufficiently.
Connector Cable external diameter (mm)
6 mm 5 mm 4 mm 3 mm
For 6-mm-dia. cable 1 0 --- ---
For 4-mm-dia. cable --- 2 1 ---
For 3-mm-dia. cable --- --- 2 1
Triangle mark
Pin block
Cover lock
Cover
Pin Block
(Screw-on Connectors)
Cap
A
Sensor Side Connecting Cable Panel Side
(Power-supply Side)
(Plug) (Socket) (Plug) (Socket)
Protrusion on
cover aligns with
polarity key.
Polarity key
Alignment marks
XS5
24
Safety Precautions
Do not use the Connectors in an atmosphere or environment that
exceeds the specifications.
Connector Connection and Disconnection
When connecting or disconnecting Connectors, be sure to hold the
Connectors by hand.
Do not hold the cable when disconnecting Connectors.
When mating Connectors, be sure to insert the plug all the way to
the back of the socket before attempting to lock the Connectors.
Do not use tools of any sort to mate the Connectors. Always use
your hands. Pliers or other tools may damage the Connectors.
When mating the Connectors to XS2 or other M12 Connectors,
tighten the lock by hand to a torque of 0.39 to 0.49 Nm.
Wiring
Always confirm wiring diagrams before wiring sensors, limit
switches, or other devices.
Lay the cables so that external force is not applied to the
Connectors. Otherwise, the degree of protection (IP67) may not be
achieved.
Degree of Protection
The degree of protection of Connectors (IP67) is not for a fully
watertight structure. Do not the Connectors underwater.
Do not step on or place any objects on the Connectors. Doing so
may damage the Connectors.
General Precautions
Do not pull excessively on the Connectors or cables. Do not install
the Connectors or cables in any way that would place a load
directly on the mating section or cable connections. Doing so can
damage the Connectors or break the wires inside the cables.
Install the Connectors and cables where they will not be stepped
on to prevent the wires inside the cables from being broken and to
prevent the Connectors from being damaged. If the Connectors or
cables must be installed where they might be stepped on, protect
them with covers.
Refer to the specifications for your cables before bending the
cables and do not bend them past their minimum bending radius.
If sensors or switches are not attached during installation, protect
the mating surface of the Connector with a XS5Z-11 Waterproof
Cover of XS2Z-14/15 Dust Cover.
Setup
Do not make any cable bends near the base of the Unit.
Any bends made must have a minimum radius of 40 mm.
Precautions for Correct Use
Terms and Conditions Agreement
Read and understand this catalog.
Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you
have any questions or comments.
Warranties.
(a) Exclusive Warranty. Omron’s exclusive warranty is that the Products will be free from defects in materials and workmanship
for a period of twelve months from the date of sale by Omron (or such other period expressed in writing by Omron). Omron
disclaims all other warranties, express or implied.
(b) Limitations. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, ABOUT
NON-INFRINGEMENT, MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE OF THE PRODUCTS. BUYER
ACKNOWLEDGES THAT IT ALONE HAS DETERMINED THAT THE
PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE.
Omron further disclaims all warranties and responsibility of any type for claims or expenses based on infringement by the
Products or otherwise of any intellectual property right. (c) Buyer Remedy. Omron’s sole obligation hereunder shall be, at
Omron’s election, to (i) replace (in the form originally shipped with Buyer responsible for labor charges for removal or
replacement thereof) the non-complying Product, (ii) repair the non-complying Product, or (iii) repay or credit Buyer an amount
equal to the purchase price of the non-complying Product; provided that in no event shall Omron be responsible for warranty,
repair, indemnity or any other claims or expenses regarding the Products unless Omrons analysis confirms that the Products
were properly handled, stored, installed and maintained and not subject to contamination, abuse, misuse or inappropriate
modification. Return of any Products by Buyer must be approved in writing by Omron before shipment. Omron Companies shall
not be liable for the suitability or unsuitability or the results from the use of Products in combination with any electrical or
electronic components, circuits, system assemblies or any other materials or substances or environments. Any advice,
recommendations or information given orally or in writing, are not to be construed as an amendment or addition to the above
warranty.
See http://www.omron.com/global/ or contact your Omron representative for published information.
Limitation on Liability; Etc.
OMRON COMPANIES SHALL NOT BE LIABLE FOR SPECIAL, INDIRECT, INCIDENTAL, OR CONSEQUENTIAL DAMAGES,
LOSS OF PROFITS OR PRODUCTION OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS,
WHETHER SUCH CLAIM IS BASED IN CONTRACT, WARRANTY, NEGLIGENCE OR STRICT LIABILITY.
Further, in no event shall liability of Omron Companies exceed the individual price of the Product on which liability is asserted.
Suitability of Use.
Omron Companies shall not be responsible for conformity with any standards, codes or regulations which apply to the
combination of the Product in the Buyer’s application or use of the Product. At Buyers request, Omron will provide applicable
third party certification documents identifying ratings and limitations of use which apply to the Product. This information by itself
is not sufficient for a complete determination of the suitability of the Product in combination with the end product, machine,
system, or other application or use. Buyer shall be solely responsible for determining appropriateness of the particular Product
with respect to Buyers application, product or system. Buyer shall take application responsibility in all cases.
NEVER USE THE PRODUCT FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY OR IN LARGE
QUANTITIES WITHOUT ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS,
AND THAT THE OMRON PRODUCT(S) IS PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE
OVERALL EQUIPMENT OR SYSTEM.
Programmable Products.
Omron Companies shall not be responsible for the user’s programming of a programmable Product, or any consequence
thereof.
Performance Data.
Data presented in Omron Company websites, catalogs and other materials is provided as a guide for the user in determining
suitability and does not constitute a warranty. It may represent the result of Omron’s test conditions, and the user must correlate
it to actual application requirements. Actual performance is subject to the Omron’s Warranty and Limitations of Liability.
Change in Specifications.
Product specifications and accessories may be changed at any time based on improvements and other reasons. It is our
practice to change part numbers when published ratings or features are changed, or when significant construction changes are
made. However, some specifications of the Product may be changed without any notice. When in doubt, special part numbers
may be assigned to fix or establish key specifications for your application. Please consult with your Omron’s representative at
any time to confirm actual specifications of purchased Product.
Errors and Omissions.
Information presented by Omron Companies has been checked and is believed to be accurate; however, no responsibility is
assumed for clerical, typographical or proofreading errors or omissions.
2016.3
In the interest of product improvement, specifications are subject to change without notice.
OMRON Corporation
Industrial Automation Company
http://www.ia.omron.com/
(c)Copyright OMRON Corporation 2016 All Right Reserved.