Monitoring relay for monitoring 3-phase voltages of 483…897 V AC,
undervoltage, window, phase sequence, phase failure, asymmetry,
supply voltage can be selected using power module, 2 PDTs
Commercial data
GTIN (EAN)
4 017918 996482
sales group H216
Pack 1 pcs.
Customs tariff 85364900
Catalog page information Page 655 (IF-2009)
Product notes
WEEE/RoHS-compliant since:
12/03/2009
http://
www.download.phoenixcontact.com
Please note that the data given
here has been taken from the
online catalog. For comprehensive
information and data, please refer
to the user documentation. The
General Terms and Conditions of
Use apply to Internet downloads.
Product description
Increasingly higher demands are being placed on safety and system availability – across all sectors. Processes are
becoming more and more complex, not only in mechanical engineering and the chemical industry, but also in plant and
automation technology. Demands on power engineering are also increasing constantly.
Error-free and therefore cost-effective operation can only be achieved through continuous monitoring of important
network and system parameters. Electronic monitoring relays in the EMD series are available for a wide range of
monitoring tasks to avoid the consequences of errors or to keep them within limits.
EMD-FL-3V-690 Order No.: 2885249
http://eshop.phoenixcontact.de/phoenix/treeViewClick.do?UID=2885249
PHOENIX CONTACT Inc., USA Page 2 / 5
http://www.phoenixcon.com Feb 3, 2011
The operating states are indicated using colored LEDs, errors that may occur can be sent to a control system via a
floating contact or can shut down a part of the system. Some device versions are equipped with startup and response
delays in order to briefly tolerate measured values outside the set monitoring range.
Technical data
Input data
Nominal input voltage UN3 ~ 690 V
Maximum temperature coefficient < 0.1 %/K
Function Undervoltage, window, asymmetry, phase sequence, phase
failure
Min. setting range -30 % ... 20 % (From UN)
Max. setting range -20 % ... 30 % (From UN)
Min setting range of the voltage threshold value 483 V AC ... 828 V AC
Max. setting range of the voltage threshold value 552 V AC ... 897 V AC
Setting range for response delay 0.1 s ... 10 s
Basic accuracy ± 5 % (of scale end value)
Setting accuracy ≤ 5 % (of scale end value)
Repeat accuracy ≤ 2 %
Asymmetry 5% ... 25% / OFF
Recovery time 500 ms
Contact side
Contact type 2 floating PDT contacts
Maximum switching voltage 250 V AC (in acc. with IEC 60664-1)
Interrupting rating (ohmic load) max. 750 VA (3 A/250 V AC, module aligned, ≤ 5 mm spacing)
1250 VA (5 A/250 V AC, module not aligned, ≥ 5 mm spacing)
Output fuse 5 A (fast-blow)
Power supply
Supply voltage range 110 V AC ... 500 V AC (see Power modules)
General data
Width 45 mm
Height 90 mm
Depth 113 mm
Mechanical service life Approx. 2 x 107 cycles
Operating mode 100% operating factor
EMD-FL-3V-690 Order No.: 2885249
http://eshop.phoenixcontact.de/phoenix/treeViewClick.do?UID=2885249
PHOENIX CONTACT Inc., USA Page 3 / 5
http://www.phoenixcon.com Feb 3, 2011
Ambient temperature (operation) -25 °C ... 55 °C
-25 °C ... 40 °C (corresponds to UL 508)
Ambient temperature (storage/transport) -25 °C ... 70 °C
Mounting position Any
Assembly instructions on TS 35 profile rail acc. to EN 60715
Electromagnetic compatibility Conformance with EMC Directive 2004/108/EC
Surge voltage category III, basic insulation (as per EN 50178)
Housing insulation material Polyamide PA, self-extinguishing
Color green
Rated insulation voltage 600 V (According to EN 50178)
Conformance CE-compliant
UL, USA / Canada UL/C-UL listed UL 508
Connection data
Conductor cross section stranded min. 0.25 mm²
Conductor cross section stranded max. 2.5 mm²
Conductor cross section solid min. 0.5 mm²
Conductor cross section solid max. 2.5 mm²
Conductor cross section AWG/kcmil min. 20
Conductor cross section AWG/kcmil max 14
Stripping length 8 mm
Type of connection Screw connection
Certificates / Approvals
Certification CUL Listed, UL Listed
Additional products
Item Designation Description
General
2885281 EMD-SL-PS45-110AC Power modules, pluggable, for EMD-FL-..., supply voltage: 88 V
AC ... 121 V AC
EMD-FL-3V-690 Order No.: 2885249
http://eshop.phoenixcontact.de/phoenix/treeViewClick.do?UID=2885249
PHOENIX CONTACT Inc., USA Page 4 / 5
http://www.phoenixcon.com Feb 3, 2011
2885744 EMD-SL-PS45-120AC Power modules, pluggable, for EMD-FL-..., supply voltage: 108 V
AC ... 132 V AC
2885294 EMD-SL-PS45-230AC Power modules, pluggable, for EMD-FL-..., supply voltage: 195 V
AC ... 264 V AC
2885304 EMD-SL-PS45-400AC Power modules, pluggable, for EMD-FL-..., supply voltage:
323...456 V AC
2885317 EMD-SL-PS45-500AC Power modules, pluggable, for EMD-FL-..., supply voltage:
425...550 V AC
Diagrams/Drawings
Block diagram
EMD-FL-3V-690 Order No.: 2885249
http://eshop.phoenixcontact.de/phoenix/treeViewClick.do?UID=2885249
PHOENIX CONTACT Inc., USA Page 5 / 5
http://www.phoenixcon.com Feb 3, 2011
Address
PHOENIX CONTACT Inc., USA
586 Fulling Mill Road
Middletown, PA 17057,USA
Phone (800) 888-7388
Fax (717) 944-1625
http://www.phoenixcon.com
© 2011 Phoenix Contact
Technical modifications reserved;