1E3FZ/E3FR
Easy mounting photoelectric sensor in short M18 housing
E3FZ/E3FR
Secure-click snap mounting for fast
installation
High power LED for enhanced
sensing distance
Short housing with less than
40 mm length
Minimal optical axis deviation for easy
alignment
Features
Up to 10 times faster
Up to 3 times faster
Conventional
square sensors
Conventional
cylindrical
sensors
E3FZ with
SecureClick*
*SecureClick has been tested to withstand severe vibrations.
>>CLICK
2
1
The SecureClick snap mounting mechanism provides easy
installation in 2 steps and enhanced protection against vibration.
Easy and fast installation
Installation time can be reduced by up to 10 times compared to
conventional sensors.
E55E-EN-01+E3FZ-E3FR+Datasheet.FM Seite 1 Dienstag, 15. April 2008 5:17 17
2 Standard Photoelectric Sensors
Ordering Information
Snap mounting – E3FZ*2
Radial mounting – E3FR
*1. Measured with reflector E39-R1S
The reflector is sold separately.
*2. Mounting with Snap-Holder (provided with product) or M18 Nuts (provided with product) possible.
*3.Pre-wired connectors are available on request (item description see "Model Number Legend" on page 4)
Sensor type Sensing distance Connection method Order code
NPN output PNP output
Through-beam 15 m ––2 m
*3 E3FZ-T61H 2M E3FZ-T81H 2M
––
*3 E3FZ-T66H E3FZ-T86H
Retroreflective with M.S.R. 0.1 to 4 m *1––2 m
*3 E3FZ-R61H 2M E3FZ-R81H 2M
––
*3 E3FZ-R66H E3FZ-R86H
Diffuse reflective 1 m (adjustable) ––2 m
*3 E3FZ-D62 2M E3FZ-D82 2M
––
*3 E3FZ-D67 E3FZ-D87
Diffuse reflective
(background suppression)
100 mm (fixed) ––2 m
*3 E3FZ-LS61H 2M E3FZ-LS81H 2M
––
*3 E3FZ-LS66H E3FZ-LS86H
200 mm (fixed)
––2 m
*3 E3FZ-LS64H 2M E3FZ-LS84H 2M
––
*3 E3FZ-LS69H E3FZ-LS89H
Sensor type Sensing distance Connection method Order code
NPN output PNP output
Through-beam 15 m ––2 m
*3 E3FR-T61H 2M E3FR-T81H 2M
––
*3 E3FR-T66H E3FR-T86H
Retroreflective with M.S.R. 0.1 to 4 m *1
––2 m
*3 E3FR-R61H 2M E3FR-R81H 2M
––
*3 E3FR-R66H E3FR-R86H
Diffuse reflective 1 m (adjustable) ––2 m
*3 E3FR-D62 2M E3FR-D82 2M
––
*3 E3FR-D67 E3FR-D87
Diffuse reflective
(background suppression)
100 mm (fixed) ––2 m
*3 E3FR-LS61H 2M E3FR-LS81H 2M
––
*3 E3FR-LS66H E3FR-LS86H
200 mm (fixed)
––2 m
*3 E3FR-LS64H 2M E3FR-LS84H 2M
––
*3 E3FR-LS69H E3FR-LS89H
E55E-EN-01+E3FZ-E3FR+Datasheet.FM Seite 2 Dienstag, 15. April 2008 5:17 17
3E3FZ/E3FR
Accessories
Reflectors
Mounting brackets
Sensor I/O connectors
Note: For the complete list of sensor I/O connectors refer to E26E Accessories datasheet.
Shape Type Material Features Size in mm Applicable Sensor Order code
General purpose
reflectors
-ABS base
- Acrylic surface
Surface screw
mounting
(diagonal holes)
59.9x40.3x7.5 - Retroreflective
photo electric
sensors –
non polarizing
- Retroreflective
photo electric
sensors –
polarizing (MSR)
E39-R1S
Snap mounting dia 30 mm
(reflector)
dia 6.5 mm
(snap mount)
E39-R49
Shape Type Material Features Applicable Sensor Order code
General purpose
mounting
stainless steel Horizontal angle adjustment E3FZ (dia 20mm
snap holder)
E39-EL8
Telescope
mounting
3D rotation (fits to 12 mm mounting
rod)
E39-EL9
Straight 2 m 4-wire PVC XS2F-D421-D80-A
PUR Y92E-M12PUR4S2M-L
5 m PVC XS2F-D421-G80-A
PUR Y92E-M12PUR4S5M-L
L-shaped 2 m PVC XS2F-D422-D80-A
PUR Y92E-M12PUR4A2M-L
5 m PVC XS2F-D422-G80-A
PUR Y92E-M12PUR4A5M-L
E55E-EN-01+E3FZ-E3FR+Datasheet.FM Seite 3 Dienstag, 15. April 2008 5:17 17
4 Standard Photoelectric Sensors
Model Number Legend
e.g., E3FZ-T81H; short housing/ through-beam/PNP output/2 m cable/without an adjustor/L-on/D-on by wire/
E3FZ-T86H-D; short housing/through-beam/PNP output/M12 connector/without an adjustor/L-on/D-on by wire/receiver
E3FR-LS86; radial housing/background-suppression/PNP output/M12 connector/sensing distance of 100 mm/without an adjustor/
L-on/D-on by wire/
1. Cylindrical family name: E3F
2. Series name
2: standard housing (seperate naming rule)
Z: short housing
R: radial housing
3. Sensing method
T: through-beam
R: retroreflective
D: diffuse reflective
LS: background suppression
4. Output
6: NPN output
8: PNP output
5. Connection
Through-beam, retroreflective types
1: 2 m cable
6: M12 connector
Diffuse reflective types
2: 2 m cable
7: M12 connector
Background suppression types
1: 2 m cable/sensing distance of 100 mm
4: 2 m cable/sensing distance of 200 mm
6: M12 connector/sensing distance of 100 mm
9: M12 connector/sensing distance of 200 mm
6. Adjuster
Blank: with volume adjuster/L-on/D-on by wire
H: without volume adjuster/L-on/D-on by wire
7. Emitter/ Receiver
L: emitter
D: receiver
8. Kind of connection
Blank: standard 2 m cable or M12 connector
M1J: pre-wired with 30 cm cable and
M12 plug connector (4 pin)
M3J: pre-wired with 30 cm cable and
M8 plug connector (4 pin)
M5J: pre-wired with 30 cm cable and
M8 plug connector (3 pin)
M1TJ: pre-wired with 30cm cable and Twist&Click
M12 plug connector (4 pin)
9. Cable length
Blank: M12 connector
Number: cable length
E3F@-@@@@-@-@@
1 2 3456 7 89
E55E-EN-01+E3FZ-E3FR+Datasheet.FM Seite 4 Donnerstag, 15. Mai 2008 4:30 16
5E3FZ/E3FR
Mounting and dismounting
Mounting
Dismounting
Insert the snap holder into the
mounting hole from the front
Insert the sensor into the snap
holder from the back
Verify the correct position
(a clicking sound can be heard)
Verify the correct position
(a clicking sound can be heard)
Step 1
Step 2
2.5 to 2.9 mm
dia 20.1 to 20.2 mm
Apply soft pressure to the sensor
lens in the indicated areas (e.g. with
two thumbs)
Press down both snap-fits and push
the snap holder forward.
Remove the sensor
Remove the snap holder
Step 1
Step 2
E55E-EN-01+E3FZ-E3FR+Datasheet.FM Seite 5 Dienstag, 15. April 2008 5:17 17
6 Standard Photoelectric Sensors
Specifications
Item Through-beam Retroreflective Diffuse reflective
E3FZ-T / E3FR-T E3FZ-R / E3FR-R E3FZ-D / E3FR-D
Sensing distance 15 m 4 m [100 mm] 1 m (white paper 300x300 mm)
Spot diameter
Standard sensing object Opaque: 12 mm dia .min Opaque: 75 mm dia. min
Differential travel 20% max. of sensing distance
max.
Black/white error
Directional angle Emitter and Reciever: 3° to 15° Sensor: 3° to 10°, Reflector: 3
Light source (wave length) Infrared LED (870 nm) Red LED (660 nm) Infrared LED (860 nm)
Power supply voltage 10 to 30 VDC, including 10% ripple(p-p)
Current consumption 45mA max.
(Emitter: 25mA max.,
Receiver; 20 mA max. )
25 mA max.
Control output Load power supply voltage; 30 VDC max., Load current; 100 mA max.(Residual voltage; 2 V max.),
Light-on/Dark-on selectable by wire,
E3F@-6@: NPN open-collector output
E3F@-8@: PNP open-collector output
Protective circuits Power supply reverse polarity
protection, output short-circuit
protection, and reversed output
polarity protection
Power supply reverse polarity protection,
output short-circuit protection, mutual interference prevention and
reversed output polarity protection
Response time Operate and reset; 1 ms max.
Sensitivity adjustment One-turn adjuster
Ambient illumination
(receiver side)
Incandescent lamp; 3000 lx max., Sunlight 10000 lx max.
Ambient temperature Operating; -25 to +55°C, Storage; -40 to +70°C (with no icing or condensation)
Ambient humidity Operating; 35 to 85% RH, Storage; 35 to 95% RH (with no condensation)
Insulation resistance 20MΩ min. at 500 VDC
Dielectric resistance 1000 VAC at 50/60 Hz for 1 min
Vibration resistance Destruction; 10 to 55 Hz, 1.5 mm double amplitude for 2 hours, each in X, Y and Z directions
Shock resistance Destruction; 500 m/s2, 3 times, each in X, Y and Z directions
Degree of protection *1
*1. The IP69k test according to DIN 40 050 part 9 is intended to simulate high pressure/steam cleaning. During the test 14-16 l/min water
at 80°C is sprayed onto the sensor from different angles with 8000-10000 kPa. The sensor may not suffer any damaging effects from
high pressure water in appearance and functionality.
IEC 60529 IP67, IP69K after DIN 40050-9
Connection method Pre-wired cable (standard length 2 m), Standard M12 connector
Indicator Operation indicator: yellow, stability indicator: green
(Emitter has only power supply indicator; green)
Weight
(packed state)
Pre-wired approx. 120 g approx. 60 g
Standard
connector
approx. 40 g approx. 20 g
Material Case ABS
Cover lens
Plate window
PMMA
Accessories Instruction sheet, 2x M18 nuts, snap mounting tool (E3FZ only).
E55E-EN-01+E3FZ-E3FR+Datasheet.FM Seite 6 Dienstag, 15. April 2008 5:17 17
7E3FZ/E3FR
Specification
Item Background suppression (BGS)
E3FZ-LS@1H / E3FR-LS@1H
E3FZ-LS@6H / E3FR-LS@6H
E3FZ-LS@4H / E3FR-LS@4H
E3FZ-LS@9H / E3FR-LS@9H
Sensing distance 10 to 100 mm (White paper 100x100 mm) 10 to 200 mm (White paper 100x100 mm)
Spot diameter 4 mm dia. at sensing distance of 100 mm 18 mm dia. at sensing distance of 200 mm
Standard sensing object
Differential travel 3% of sensing distance max. 20% of sensing distance max.
Black/white error 5% of sensing distance max. 20% of sensing distance max.
Directional angle
Light source (wave length) Red LED (650 nm) Red LED (660 nm)
Power supply voltage 10 to 30 VDC, including 10% ripple(p-p)
Current consumption 25 mA max.
Control output Load power supply voltage; 30 VDC max., Load current; 100 mA max. (Residual voltage; 2 V max.),
Light-on/Dark-on selectable by wire,
E3F@-LS6: NPN open-collector output
E3F@-LS8: PNP open-collector output
Protective circuits Power supply reverse polarity protection, output short-circuit protection,
mutual interference prevention and reversed output polarity protection
Response time Operate and reset; 1 ms max.
Sensitivity adjustment
Ambient illumination
(receiver side)
Incandescent lamp; 3000 lx max., Sunlight 10000 lx max.
Ambient temperature Operating; -25 to +55°C, Storage; -40 to +70°C (with no icing or condensation)
Ambient humidity Operating; 35 to 85%RH, Storage; 35 to 95%RH (with no condensation)
Insulation resistance 20MΩ min. at 500 VDC
Dielectric resistance 1000 VAC at 50/60 Hz for 1 min
Vibration resistance Destruction; 10 to 55 Hz, 1.5 mm double amplitude for 2 hours, each in X, Y and Z directions
Shock resistance Destruction; 500m/s2, 3 times, each in X, Y and Z directions
Degree of protection *1
*1. The IP69k test according to DIN 40 050 part 9 is intended to simulate high pressure/steam cleaning. During the test 14-16 l/min water
at 80ºC is sprayed onto the sensor from different angles with 8000-10000 kPa. The sensor may not suffer any damaging effects from
high pressure water in appearance and functionality.
IEC 60529 IP67, IP69K after DIN 40050-9
Connection method Pre-wired cable (standard length 2m), Standard M12 connector
Indicator Operation indicator: yellow, stability indicator: green
Weight
(packed state)
Pre-wired approx.60g
Standard
connector
approx.20g
Material Case ABS
Cover-lens
Plate-window
PMMA
Accessories Instruction sheet, 2x M18 nuts, snap mounting tool (E3FZ only).
E55E-EN-01+E3FZ-E3FR+Datasheet.FM Seite 7 Dienstag, 15. April 2008 5:17 17
8 Standard Photoelectric Sensors
Engineering Data (typical)
Parallel Operating Range
Through-beam Models Retroreflective Models
E3F@-T@1H(T@6H) E3F@-R@1H(R@6H)
Operating Range
Diffuse reflective Models BGS Models
E3F@-D@2(D@7) E3F@-LS@1H(LS@6H), left to right E3F@-LS@4H(LS@9H), left to right
Excess Gain vs. Distance
Through-beam Models Retroreflective Models Diffuse reflective Models
E3F@-T@1H(T@6H) E3F@-R@1H(R@6H) E3F@-D@2(D@7)
Distance Y (mm)
Distance X (m)
1500
-1500
405 1015202530350
1000
500
0
-500
-1000
Y
X
150
-150 1234560
100
50
0
-50
-100
E39-R1S
E39-R1
Y
X
Distance Y (mm)
Distance X (m)
120
100
80
60
40
20
0
-20
-40
-60
-80
-100
-120
140
-140
1.80.2 0.4 0.6 0.8 1 1.2 1.4 1.60
Y
X
Sensing object: 300 x 300 white paper
Distance Y (mm)
Distance X (m)
3
2
1
0
-1
-2
-3
4
-4 10020 40 60 800
Y
X
Distance Y (mm)
Sensing object: 100 x 100 white paper
Distance X (mm)
Sensing object: 100 x 100 white paper
8
6
4
2
0
-2
-4
-6
-8
100 150 200 250500
Distance X (mm)
Distance Y (mm)
Y
X
100
50
30
10
5
3
1
0.5
0.3
0.1
5045403530252015105
0
Distance (m)
Oper-
ating
level
Excess gain ratio (multiple)
100
50
30
10
5
3
1
0.5
0.3
0.1
612345
0
E39-R1S
E39-R1
Distance (m)
Oper-
ating
level
Excess gain ratio (multiple)
100
50
30
10
5
3
1
0.5
0.3
0.1 2.50.5 1 1.5 20
Sensing object: 300 x 300 white paper
Distance (m)
Oper-
ating
level
Excess gain ratio (multiple)
E55E-EN-01+E3FZ-E3FR+Datasheet.FM Seite 8 Dienstag, 15. April 2008 5:17 17
9E3FZ/E3FR
Sensing Object Size vs. Distance Spot Diameter vs. Distance
Diffuse reflective Models BGS Models
E3F@-D@2(D@7) E3F@-LS@1H(LS@6H) E3F@-LS@4H(LS@9H)
Sensing Distance vs. Sensing Object Material Inclination Characteristics (Vertical)
BGS Models BGS Models
E3F@-LS@1H(LS@6H) E3F@-LS@4H(LS@9H) E3F@-LS@1H(LS@6H)
Inclination Characteristics (Horizontal)
BGS Models
E3F@-LS@1H(LS@6H) E3F@-LS@4H(LS@9H) E3F@-LS@4H(LS@9H)
Sensing object: White paper
1.6
1.4
1.2
1.0
0.8
0.6
0.4
0.2
1.8
0.0 600100 200 300 400 5000
Length d of sensing object (mm)
Distance (m)
d
d
10
8
6
4
2
12
020 40 60 80 100
0
Distance (mm)
Spot diameter (mm)
18
16
14
12
10
8
6
4
2
20
050 100 150 200 2500
Distance (mm)
Spot diameter (mm)
120
100
80
60
40
20
0
White
paper
Veneer Card-
board
Black
paper
Black
rubber
SUS Mirror
surface
Material
Sensing distance (mm)
250
200
150
100
50
0
Sensing distance (mm)
White
paper
Veneer Card-
board
Black
paper
Black
rubber
SUS Mirror
surface
Material
8
6
4
2
0
-2
-4
-6
-8
10
-10 804020 600-40 -20-60-80 Inclination angle (°)
Sensing distance variation (%)
−θ
Upwards and
Downwards
Center
line
Sensing
object
Inclination
angle
40
30
20
10
0
10
20
30
40
50
50 804020 600-40 -20-60-80
(Left and Right)
Center
line
Sensing
object
Inclination
angle
Sensing distance variation (%)
Inclination angle (°)
−θ
40
30
20
10
0
10
20
30
40
50
50 804020 600-40 -20-60-80
−θ
Inclination
angle
(Left and Right)
Center
line
Sensing
object
Sensing distance variation (%)
Inclination angle (°)
40
30
20
10
0
10
20
30
40
50
50 804020 600-40 -20-60-80
Center
line
Sensing
object
Upwards and
Downwards
Inclination
angle
Sensing distance variation (%)
Inclination angle (°)
E55E-EN-01+E3FZ-E3FR+Datasheet.FM Seite 9 Dienstag, 15. April 2008 5:17 17
10 Standard Photoelectric Sensors
Output Circuit Diagram
PNP Output
Model Operation
mode
Timing charts Mode
selector
switch
Output circuit
E3F@-T8
E3F@-R8
E3F@-D8
Light ON Connect the
pink wire
(Pin(2)) to
the brown
(Pin(1)) or
open the pink
wire (Pin(2).
Dark ON Connect the
pink wire
(Pin(2)) to
the blue
(Pin(3)).
E3F@-LS8 Light ON Connect the
pink wire
(Pin(2)) to
the brown
(Pin(1)) or
open the pink
wire (Pin(2).
Dark ON Connect the
pink wire
(Pin(2)) to
the blue
(Pin(3)).
Light Incident
Light Interrupted
ON
OFF
ON
OFF
Operate
Reset
Operation indicator
(yellow)
(Between brown
and black wires)
Output transistor
Load
(e.g., relay)
4
1
3
0 V
ZD
Through-beam Receivers, retroreflective models,
diffuse reflective models
Operation
indicator
(Yellow)
Stability
indicator
(Green)
Photo-
electric
Sensor
Main
Circuit
(Control
output)
10 to 30 VDC
Brown
Black
Blue
100 mA
max. Load
(Relay)
Light Incident
Light Interrupted
ON
OFF
ON
OFF
Operate
Reset
Operation indicator
(yellow)
(Between brown
and black wires)
Output transistor
Load
(e.g., relay)
3
1
Through-beam Emitter
Power
indicator
(green)
Photo-
electric
Sensor
Main
Circuit
Brown
Blue
10 to 30 VDC
NEAR FAR
ON
OFF
ON
OFF
Operate
Reset
Operation indicator
(yellow)
Output transistor
Load
(e.g., relay)
(Between brown
and black wires) 4
3
2
1
Pink
100 mA max.
(Control output)
Light-ON
Dark-ON
0 V
ZD
Operation
indicator
(Yellow)
Stability
indicator
(Green)
Photo-
electric
Sensor
Main
Circuit
10 to 30 VDC
Brown
Black
Blue
Load
(Relay)
NEAR FAR
ON
OFF
ON
OFF
Operate
Reset
Operation indicator
(yellow)
Output transistor
Load
(e.g., relay)
(Between brown
and black wires)
E55E-EN-01+E3FZ-E3FR+Datasheet.FM Seite 10 Dienstag, 15. April 2008 5:17 17
11E3FZ/E3FR
NPN Output
Model Operation
mode
Timing charts Mode
selector
switch
Output circuit
E3F@-T6
E3F@-R6
E3F@-D6
Light ON Connect the
pink wire (2)
to the blue
wire (3) or
leave open.
Dark ON Connect the
pink wire (2)
to the brown
wire (1).
E3F@-LS6 Light ON Connect the
pink wire (2)
to the blue
wire (3) or
leave open.
Dark ON Connect the
pink wire (2)
to the brown
wire (1).
Light Incident
Light Interrupted
ON
OFF
ON
OFF
Operate
Reset
Operation indicator
(yellow)
(Between brown
and black wires)
Output transistor
Load
(e.g., relay)
4
3
1
0 V
ZD
Through-beam receivers, retroreflective models,
diffuse reflective models
10 to 30 VDC
Brown
Operation
indicator
(Yellow)
Stability
indicator
(Green)
Photo-
electric
Sensor
Main
Circuit
(Control
output) 100 mA
max.
Black
Blue
Load
(Relay)
Light Incident
Light Interrupted
ON
OFF
ON
OFF
Operate
Reset
Operation indicator
(yellow)
(Between brown
and black wires)
Output transistor
Load
(e.g., relay)
3
1
Through-beam Emitter
Power
indicator
(green)
Photo-
electric
Sensor
Main
Circuit
Brown
Blue
10 to 30 VDC
NEAR FAR
ON
OFF
ON
OFF
Operate
Reset
Operation indicator
(yellow)
Output transistor
Load
(e.g., relay)
(Between brown
and black wires) 4
3
2
1
10 to 30 VDC
Brown
Black
Blue
Pink
100 mA max.
(Control output)
Light-ON
Dark-ON
Operation
indicator
(Yellow)
Stability
indicator
(Green)
0 V
Z
D
Load
(Relay)
Photo-
electric
Sensor
Main
Circuit
NEAR FAR
ON
OFF
ON
OFF
Operate
Reset
Operation indicator
(yellow)
Output transistor
Load
(e.g., relay)
(Between brown
and black wires)
2
4
13
1
2
3
4
Brown
Blue
White
Black
Pin No.
Wire colo
r
XS2F-D421-D80-A
XS2F-D421-G80-A
XS2F-D422-D80-A
XS2F-D422-G80-A
M12 4-wire Connectors
Classification Wire color Connector pin No. Application
DC
Brown APower supply (+V)
White BOperation selection
Blue CPower supply (0 V)
Black DOutput
Connector Pin Arrangement
M12 Pre-wired Connector (-M1J)
M12 Connector Pin Arrangement
3
1
24
Connectors (Sensor I/O connectors)
E55E-EN-01+E3FZ-E3FR+Datasheet.FM Seite 11 Dienstag, 15. April 2008 5:17 17
12 Standard Photoelectric Sensors
Dimensions
Note: All units are in millimeters unless otherwise stated.
E3FZ-Series
Pre-wired models Connector models
E3FZ-T@
Emitter
E3FZ-T@
Receiver
E3FZ-R@
E3FZ-LS@
E3FZ-D@
Optical Axis
M18x1 6g M18x1 6g
Power indicator (green)Power indicator (green)
M12x1 6g
15 16.25 16.25
30.25 30.355.20
4 dia
9.30
Optical Axis
M18x1 6g M18x1 6g
Stability indicator (green)
Operation indicator (yellow)Operation indicator (yellow)
Stability indicator (green)
M12x1 6g
15 16.25 16.25
30.25 30.355.20
4 dia
9.30
Optical Axis
Emitter
Receiver
M18x1 6g M18x1 6g
Stability indicator (green)
Operation indicator (yellow)Operation indicator (yellow)
Stability indicator (green)
M12x1 6g
15 16.25 16.25
30.25 30.355.20
4 dia
3.50
9.30
Optical Axis
Emitter
Receiver
M18x1 6g M18x1 6g
Stability indicator (green)
Operation indicator (yellow)
Sensitivity adjusterSensitivity adjuster
Operation indicator (yellow)
Stability indicator (green)
M12x1 6g
15 16.25 16.25
30.25
22.55
30.355.20
4 dia
3.50
9.30
E55E-EN-01+E3FZ-E3FR+Datasheet.FM Seite 12 Dienstag, 15. April 2008 5:17 17
13E3FZ/E3FR
E3FR Series
Pre-wired models Connector models
E3FR-T@1H 2M
E3FR-R@1H 2M
E3FR-LS@1H 2M
E3FR-D@2 2M
Power indicator (green)
Optical axis
25.75
40.405.20
10.75
18.25
M18x1 6g
4 dia
30.35
16.25
15
R8.3
Optical axis
25.75
40.409.30
10.75
18.25
M18x1 6g
M12x1 6g
15
R8.3
Stability indicator (green)
Operation indicator (yellow)
30.35
16.25
Emitter
Receiver
Stability indicator (green)
Operation indicator (yellow)
Receiver
Emitter
Optical axis
3.50
25.75
40.405.20
10.75
18.25
M18x1 6g
4 dia
30.35
16.25
15
R8.3
Receiver
Emitter
Optical axis
3.50
25.75
40.409.30
10.75
18.25
M18x1 6g
M12x1 6g
15
R8.3
Stability indicator (green)
Operation indicator (yellow)
Sensitivity adjuster
Receiver
Emitter
Optical axis
3.50
25.75
40.405.20
10.75
18.25
M18x1 6g
4 dia
30.35
22.55
16.25
15
R8.3
Receiver
Emitter
Optical axis
3.50
25.75
40.409.30
10.75
18.25
M18x1 6g
M12x1 6g
15
R8.3
E55E-EN-01+E3FZ-E3FR+Datasheet.FM Seite 13 Dienstag, 15. April 2008 5:17 17
14 Standard Photoelectric Sensors
Accessories
E39-R1S
Material:
ABS base,
acrylic surface
E38-R49
Material:
ABS base,
acrylic surface
E39-EL8
Material:
stainless steel
E39-EL9
(can be attached
to dia 12 mm
mounting rod)
Material:
stainless steel
Snap mount tool
Material:
ABS
34
40.3
5259.9
2.7
8
1.6
7.5
7
Two, 3.5 dia.
34.5
12.6
7.4
32.8
6.5
~ 2-3
2.5
630
32
16
38
20.15
20
14
42
15°
15°
4.3
15.5
1.5
Ø 25
E55E-EN-01+E3FZ-E3FR+Datasheet.FM Seite 14 Dienstag, 15. April 2008 5:17 17
15E3FZ/E3FR
Safety precautions
This product is not designed or rated for directly or
indirectly ensuring safety of persons. Do not use it for
such a purpose.
Do not use the product with voltage in excess of the
rated voltage. Excess voltage may result in malfunc-
tion or fire.
Never use the product with an AC power supply.
Otherwise, explostion may result.
When cleaning the product, do not apply a high-pres-
sure spray of water to one part of the product. Other-
wise, parts may become damaged and the degree of
protection may be degraded.
High-temperature environments may result in burn
injury.
The following precautions must be observed to ensure safe
operation of the Sensor.
Operating Environment
Do not use the Sensor in an environment where explosive or
flammable gas is present.
Connecting Connectors
Be sure to hold the connector cover when inserting or removing
the connector. Be sure to tighten the connector lock by hand;
do not use pliers or other tools. If the tightening is insufficient, the
degree of protection will not be maintained and the Sensor may
become loose due to vibration. The appropriate tightening torque
is 0.39 to 0.49 N·m for M12 connectors.
Load
Do not use a load that exceeds the rated load.
Rotation Torque for Sensitivity Adjustment
Adjust with a torque of 0.05 N·m or less.
Environements with Cleaners and Disinfectants
(e.g., Food Processing Lines)
Do not use the Sensor in environments subject to cleaners and
disifectants. They may reduce the degree of protection.
Modifications
Do not attempt to disassemble, repair, or modify the Sensor.
Outdoor Use
Do not use the Sensor in locations subject to direct sunlight.
Cleaning
Do not use thinner, alcohol, or other organic solvents. Otherwise,
the optical properties and degree of protection may be degraded.
Surface Temperature
Burn injury may occur. The Sensor surface temperature rises de-
pending on application conditions, such as the surrounding tem-
perature and the power supply voltage. Use caution when
operating or washing the Sensor.
Do not use the Sensor in any atmosphere or environment that
exceeds the ratings.
Do not install the Sensor in the following locations.
(1)Locations subject to direct sunlight
(2)Locations subject to condensation due to high humidity
(3)Locations subject to corrosive gas
(4)Locations where the Sensor may receive direct vibration or
shock
Connecting and Mounting
(1)The maximum power supply voltage is 30 VDC. Before turning
the power ON, make sure that the power supply voltage does
not exceed the maximum voltage.
(2)Laying Sensor wiring in the same conduit or duct as high-volt-
age wires or power lines may result in malfunction or damage
due to induction. As a general rule, wire the Sensor in a sepa-
rate conduit or use shielded cable.
(3)Use an extension cable with a minimum thickness of 0.3 mm2
and less than 100 m long.
(4)Do not pull on the cable with excessive force.
(5)Pounding the Photoelectric Sensor with a hammer or other
tool during mounting will impair water resistance.
(6)Mount the Sensor either using the bracket (sold separately) or
on a flat surface.
(7)Be sure to turn OFF the power supply before inserting or re-
moving the connector.
Cleaning
Never use thinner or other solvents. Otherwise, the Sensor sur-
face may be dissolved.
Power Supply
If a commercial switching regulator is used, ground the FG (frame
ground) terminal.
Power Supply Reset Time
The Sensor will be able to detect objects 100 ms after the power
supply is tuned ON. Start using the Sensor 100 ms or more after
turning ON the power supply. If the load and the Sensor are con-
nected to separate power supplies, be sure to turn ON the Sensor
first.
Turning OFF the Power Supply
Output pulses may be generated even when the power supply is
OFF. Therefore, it is recommended to first turn OFF the power
supply for the load or the load line.
Load Short-circuit Protection
This Sensor is equipped with load short-circuit protection, but be
sure to not short circuit the load. Be sure to not use an output cur-
rent flow that exceeds the rated current. If a load short circuit oc-
curs, the output will turn OFF, so check the wiring before turning
ON the power supply again. The short-circuit protection circuit will
be reset. The load short-circuit protection will operate when the
current flow reaches 1.8 times the rated load current. When using
a capacitive load, use an inrush current of 1.8 times the rated load
current or higher.
Water Resistance
Do not use the Sensor in water, rainfall, or outdoors.
! Warning
! Caution
Precautions for Safe Use
Precautions for Correct Use
E55E-EN-01+E3FZ-E3FR+Datasheet.FM Seite 15 Dienstag, 15. April 2008 5:17 17
Terms and Conditions of Sale
1. Offer; Acceptance. These terms and conditions (these "Terms") are deemed
part of all quotes, agreements, purchase orders, acknowledgments, price lists,
catalogs, manuals, brochures and other documents, whether electronic or in
writing, relating to the sale of products or services (collectively, the "Products")
by Omron Electronics LLC and its subsidiary companies (“Omron”). Omron
objects to any terms or conditions proposed in Buyers purchase order or other
documents which are inconsistent with, or in addition to, these Terms.
2. Prices; Payment Terms. All prices stated are current, subject to change with-
out notice by Omron. Omron reserves the right to increase or decrease prices
on any unshipped portions of outstanding orders. Payments for Products are
due net 30 days unless otherwise stated in the invoice.
3. Discounts. Cash discounts, if any, will apply only on the net amount of invoices
sent to Buyer after deducting transportation charges, taxes and duties, and will
be allowed only if (i) the invoice is paid according to Omron’s payment terms
and (ii) Buyer has no past due amounts.
4. Interest. Omron, at its option, may charge Buyer 1-1/2% interest per month or
the maximum legal rate, whichever is less, on any balance not paid within the
stated terms.
5. Orders. Omron will accept no order less than $200 net billing.
6. Governmental Approvals. Buyer shall be responsible for, and shall bear all
costs involved in, obtaining any government approvals required for the impor-
tation or sale of the Products.
7. Taxes. All taxes, duties and other governmental charges (other than general
real property and income taxes), including any interest or penalties thereon,
imposed directly or indirectly on Omron or required to be collected directly or
indirectly by Omron for the manufacture, production, sale, delivery, importa-
tion, consumption or use of the Products sold hereunder (including customs
duties and sales, excise, use, turnover and license taxes) shall be charged to
and remitted by Buyer to Omron.
8. Financial. If the financial position of Buyer at any time becomes unsatisfactory
to Omron, Omron reserves the right to stop shipments or require satisfactory
security or payment in advance. If Buyer fails to make payment or otherwise
comply with these Terms or any related agreement, Omron may (without liabil-
ity and in addition to other remedies) cancel any unshipped portion of Prod-
ucts sold hereunder and stop any Products in transit until Buyer pays all
amounts, including amounts payable hereunder, whether or not then due,
which are owing to it by Buyer. Buyer shall in any event remain liable for all
unpaid accounts.
9. Cancellation; Etc. Orders are not subject to rescheduling or cancellation
unless Buyer indemnifies Omron against all related costs or expenses.
10. Force Majeure. Omron shall not be liable for any delay or failure in delivery
resulting from causes beyond its control, including earthquakes, fires, floods,
strikes or other labor disputes, shortage of labor or materials, accidents to
machinery, acts of sabotage, riots, delay in or lack of transportation or the
requirements of any government authority.
11. Shipping; Delivery. Unless otherwise expressly agreed in writing by Omron:
a. Shipments shall be by a carrier selected by Omron; Omron will not drop ship
except in “break down” situations.
b. Such carrier shall act as the agent of Buyer and delivery to such carrier shall
constitute delivery to Buyer;
c. All sales and shipments of Products shall be FOB shipping point (unless oth-
erwise stated in writing by Omron), at which point title and risk of loss shall
pass from Omron to Buyer; provided that Omron shall retain a security inter-
est in the Products until the full purchase price is paid;
d. Delivery and shipping dates are estimates only; and
e. Omron will package Products as it deems proper for protection against nor-
mal handling and extra charges apply to special conditions.
12. Claims. Any claim by Buyer against Omron for shortage or damage to the
Products occurring before delivery to the carrier must be presented in writing
to Omron within 30 days of receipt of shipment and include the original trans-
portation bill signed by the carrier noting that the carrier received the Products
from Omron in the condition claimed.
13. Warranties. (a) Exclusive Warranty. Omron’s exclusive warranty is that the
Products will be free from defects in materials and workmanship for a period of
twelve months from the date of sale by Omron (or such other period expressed
in writing by Omron). Omron disclaims all other warranties, express or implied.
(b) Limitations. OMRON MAKES NO WARRANTY OR REPRESENTATION,
EXPRESS OR IMPLIED, ABOUT NON-INFRINGEMENT, MERCHANTABIL-
ITY OR FITNESS FOR A PARTICULAR PURPOSE OF THE PRODUCTS.
BUYER ACKNOWLEDGES THAT IT ALONE HAS DETERMINED THAT THE
PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR
INTENDED USE. Omron further disclaims all warranties and responsibility of
any type for claims or expenses based on infringement by the Products or oth-
erwise of any intellectual property right. (c) Buyer Remedy. Omron’s sole obli-
gation hereunder shall be, at Omron’s election, to (i) replace (in the form
originally shipped with Buyer responsible for labor charges for removal or
replacement thereof) the non-complying Product, (ii) repair the non-complying
Product, or (iii) repay or credit Buyer an amount equal to the purchase price of
the non-complying Product; provided that in no event shall Omron be responsi-
ble for warranty, repair, indemnity or any other claims or expenses regarding
the Products unless Omron’s analysis confirms that the Products were prop-
erly handled, stored, installed and maintained and not subject to contamina-
tion, abuse, misuse or inappropriate modification. Return of any Products by
Buyer must be approved in writing by Omron before shipment. Omron Compa-
nies shall not be liable for the suitability or unsuitability or the results from the
use of Products in combination with any electrical or electronic components,
circuits, system assemblies or any other materials or substances or environ-
ments. Any advice, recommendations or information given orally or in writing,
are not to be construed as an amendment or addition to the above warranty.
See http://www.omron247.com or contact your Omron representative for pub-
lished information.
14. Limitation on Liability; Etc. OMRON COMPANIES SHALL NOT BE LIABLE
FOR SPECIAL, INDIRECT, INCIDENTAL, OR CONSEQUENTIAL DAMAGES,
LOSS OF PROFITS OR PRODUCTION OR COMMERCIAL LOSS IN ANY
WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS
BASED IN CONTRACT, WARRANTY, NEGLIGENCE OR STRICT LIABILITY.
Further, in no event shall liability of Omron Companies exceed the individual
price of the Product on which liability is asserted.
15. Indemnities. Buyer shall indemnify and hold harmless Omron Companies and
their employees from and against all liabilities, losses, claims, costs and
expenses (including attorney's fees and expenses) related to any claim, inves-
tigation, litigation or proceeding (whether or not Omron is a party) which arises
or is alleged to arise from Buyer's acts or omissions under these Terms or in
any way with respect to the Products. Without limiting the foregoing, Buyer (at
its own expense) shall indemnify and hold harmless Omron and defend or set-
tle any action brought against such Companies to the extent based on a claim
that any Product made to Buyer specifications infringed intellectual property
rights of another party.
16. Property; Confidentiality. Any intellectual property in the Products is the exclu-
sive property of Omron Companies and Buyer shall not attempt to duplicate it
in any way without the written permission of Omron. Notwithstanding any
charges to Buyer for engineering or tooling, all engineering and tooling shall
remain the exclusive property of Omron. All information and materials supplied
by Omron to Buyer relating to the Products are confidential and proprietary,
and Buyer shall limit distribution thereof to its trusted employees and strictly
prevent disclosure to any third party.
17. Export Controls. Buyer shall comply with all applicable laws, regulations and
licenses regarding (i) export of products or information; (iii) sale of products to
“forbidden” or other proscribed persons; and (ii) disclosure to non-citizens of
regulated technology or information.
18. Miscellaneous. (a) Waiver. No failure or delay by Omron in exercising any right
and no course of dealing between Buyer and Omron shall operate as a waiver
of rights by Omron. (b) Assignment. Buyer may not assign its rights hereunder
without Omron's written consent. (c) Law. These Terms are governed by the
law of the jurisdiction of the home office of the Omron company from which
Buyer is purchasing the Products (without regard to conflict of law princi-
ples). (d) Amendment. These Terms constitute the entire agreement between
Buyer and Omron relating to the Products, and no provision may be changed
or waived unless in writing signed by the parties. (e) Severability
. If any provi-
sion hereof is rendered ineffective or invalid, such provision shall not invalidate
any other provision. (f) Setoff. Buyer shall have no right to set off any amounts
against the amount owing in respect of this invoice. (g) Definitions. As used
herein, “including” means “including without limitation”; and “Omron Compa-
nies” (or similar words) mean Omron Corporation and any direct or indirect
subsidiary or affiliate thereof.
Certain Precautions on Specifications and Use
1. Suitability of Use. Omron Companies shall not be responsible for conformity
with any standards, codes or regulations which apply to the combination of the
Product in the Buyer’s application or use of the Product. At Buyer’s request,
Omron will provide applicable third party certification documents identifying
ratings and limitations of use which apply to the Product. This information by
itself is not sufficient for a complete determination of the suitability of the Prod-
uct in combination with the end product, machine, system, or other application
or use. Buyer shall be solely responsible for determining appropriateness of
the particular Product with respect to Buyer’s application, product or system.
Buyer shall take application responsibility in all cases but the following is a
non-exhaustive list of applications for which particular attention must be given:
(i) Outdoor use, uses involving potential chemical contamination or electrical
interference, or conditions or uses not described in this document.
(ii) Use in consumer products or any use in significant quantities.
(iii) Energy control systems, combustion systems, railroad systems, aviation
systems, medical equipment, amusement machines, vehicles, safety equip-
ment, and installations subject to separate industry or government regulations.
(iv) Systems, machines and equipment that could present a risk to life or prop-
erty. Please know and observe all prohibitions of use applicable to this Prod-
uct.
NEVER USE THE PRODUCT FOR AN APPLICATION INVOLVING SERIOUS
RISK TO LIFE OR PROPERTY OR IN LARGE QUANTITIES WITHOUT
ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO
ADDRESS THE RISKS, AND THAT THE OMRON’S PRODUCT IS PROP-
ERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE
OVERALL EQUIPMENT OR SYSTEM.
2. Programmable Products. Omron Companies shall not be responsible for the
user’s programming of a programmable Product, or any consequence thereof.
3. Performance Data. Data presented in Omron Company websites, catalogs
and other materials is provided as a guide for the user in determining suitabil-
ity and does not constitute a warranty. It may represent the result of Omron’s
test conditions, and the user must correlate it to actual application require-
ments. Actual performance is subject to the Omron’s Warranty and Limitations
of Liability.
4. Change in Specifications. Product specifications and accessories may be
changed at any time based on improvements and other reasons. It is our prac-
tice to change part numbers when published ratings or features are changed,
or when significant construction changes are made. However, some specifica-
tions of the Product may be changed without any notice. When in doubt, spe-
cial part numbers may be assigned to fix or establish key specifications for
your application. Please consult with your Omron’s representative at any time
to confirm actual specifications of purchased Product.
5. Errors and Omissions. Information presented by Omron Companies has been
checked and is believed to be accurate; however, no responsibility is assumed
for clerical, typographical or proofreading errors or omissions.
Printed on recycled paper.
Cat. No. E55E-EN-01 03/11 Note: Specifications are subject to change. © 2011 Omron Electronics LLC Printed in U.S.A.
OMRON CANADA, INC. • HEAD OFFICE
Toronto, ON, Canada 416.286.6465 866.986.6766 www.omron247.com
OMRON ELECTRONICS DE MEXICO • HEAD OFFICE
México DF 52.
55.59.01.43.00
001.800.556.6766 mela@omron.com
OMRON ELECTRONICS DE MEXICO • SALES OFFICE
Apodaca, N.L. 52.81.11.56.99.20 001.800.556.6766 mela@omron.com
OMRON ELETRÔNICA DO BRASIL LTDA • HEAD OFFICE
São Paulo, SP, Brasil 55.11.2101.6300 www.omron.com.br
OMRON ARGENTINA • SALES OFFICE
Cono Sur 54.11.4783.5300
OMRON CHILE • SALES OFFICE
Santiago 56.9.9917.3920
OTHER OMRON LATIN AMERICA SALES
54.11.4783.5300
Automation Systems
• Programmable logic controllers (PLC) • Human machine interfaces (HMI) • Remote I/O
• Industrial PC’s • Software
Motion & Drives
• Motion controllers • Servo systems • AC drives
Control Components
• Temperature controllers • Power supplies • Timers • Counters • Programmable relays
• Digital panel indicators • Electromechanical relays • Monitoring products • Solid-state relays
• Limit switches • Pushbutton switches • Low voltage switch gear
Sensing & Safety
• Photoelectric sensors • Inductive sensors • Capacitive & pressure sensors
• Cable connectors • Displacement & width-measuring sensors • Vision systems
• Safety networks • Safety sensors • Safety units/relay units • Safety door/guard lock switches
Authorized Distributor:
OMRON INDUSTRIAL AUTOMATION • THE AMERICAS HEADQUARTERS Schaumburg, IL USA 847.843.7900 800.556.6766 www.omron247.com
OMRON EUROPE B.V. •
Wegalaan 67-69, NL-2132 JD, Hoofddorp, The Netherlands.
Tel: +31 (0) 23 568 13 00
Fax: +31 (0) 23 568 13 88
www.industrial.omron.eu
Mouser Electronics
Authorized Distributor
Click to View Pricing, Inventory, Delivery & Lifecycle Information:
Omron:
E3FZ-R81H 2M E3FZ-B66 E3FZ-LS81H-M1TJ 03M E3FZ-T81H-M1TJ 03M E3FZ-LS81H 2M E3FZ-D82-M1TJ 03M
E3FZ-B86 E3FZ-LS84H-M1TJ 03M E3FZ-LS86H E3FZ-R86H E3FZ-T81H 2M E3FZ-R81H-M1TJ 03M E3FZ-D82
2M E3FZ-B81 2M E3FZ-D87 E3FZ-LS84H 2M E3FZ-LS89H E3FZ-T86H E3FZ-LS66H E3FZ-T61H 2M E3FZ-D62
E3FZ-LS64H 2M E3FZ-LS69H E3FZ-T66H E3FZ-D67 E3FZ-R61H E3FZ-LS61H 2M