Reflection-less Low Pass Filter
5 - 684 MHz
Rev. V2
MAFL-011082
1
1
MACOM Technology Solutions Inc. (MACOM) and its affiliates reserve the right to make changes to the product(s) or information contained herein without notice.
Visit www.macom.com for additional data sheets and product information.
For further information and support please visit:
https://www.macom.com/support
DC-0019302
1
Features
75 Ω
Surface Mount 18 mm device
Low Insertion Loss to 684 MHz
Matched to 1218 MHz
RoHS Compliant and Pb free
Description
MAFL-011082 is a reflection less low pass filter with
a pass band from 5 - 684 MHz with low insertion loss
in the pass band and excellent matched return loss
to 1218 MHz.
Ordering Information1,2
1. Reference Application Note M513 for reel size information.
2. All sample boards include 5 loose parts.
Part Number Package
MAFL-011082 300 piece reel
MAFL-011082-TB Sample Board
3. MACOM recommends connecting unused package pins to
ground.
4. The exposed pad centered on the package bottom must be
connected to RF, DC and thermal ground.
Pin # Function
1, 2, 4, 5, 6, 7, 8, 9,
11, 12, 13, 14, 15, 16 Ground
3 Input Port
10 Output Port
Functional Schematic
* Restrictions on Hazardous Substances, compliant to current RoHS EU directive.
Pin Configuration3,4
Parameter Test Conditions Frequency (MHz) Units Min Typical Max
Insertion Loss 5 - 684 dB 0.75 1.0
Filter Rejection 1000
1218 dB 22
35
24
45
Filter Input Port Return Loss 5 - 1218 dB 18 22
Electrical Specifications: TA = 25°C, Z0 = 75 Ω
Reflection-less Low Pass Filter
5 - 684 MHz
Rev. V2
MAFL-011082
2
2
MACOM Technology Solutions Inc. (MACOM) and its affiliates reserve the right to make changes to the product(s) or information contained herein without notice.
Visit www.macom.com for additional data sheets and product information.
For further information and support please visit:
https://www.macom.com/support
DC-0019302
2
Handling Procedures
Please observe the following precautions to avoid
damage:
Static Sensitivity
These electronic devices are sensitive to
electrostatic discharge (ESD) and can be damaged
by static electricity. Proper ESD control techniques
should be used when handling these devices.
Absolute Maximum Ratings5,6
Parameter Value
RF Power 250 mW
DC Current 30 mA
Operating & Storage
Temperature -40ºC to +85ºC
5. Exceeding any one or combination of these limits may cause
permanent damage to this device.
6. MACOM does not recommend sustained operation near these
survivability limits.
Typical Performance Curves
Low Pass Filter Input Port Return Loss
Reflection-less Low Pass Filter
5 - 684 MHz
Rev. V2
MAFL-011082
3
3
MACOM Technology Solutions Inc. (MACOM) and its affiliates reserve the right to make changes to the product(s) or information contained herein without notice.
Visit www.macom.com for additional data sheets and product information.
For further information and support please visit:
https://www.macom.com/support
DC-0019302
3
Recommended PCB Configuration
Dimensions in mm. Tolerance: .x ± 0.1, .xx ± 0.05
Filter Outline Drawing
Reflection-less Low Pass Filter
5 - 684 MHz
Rev. V2
MAFL-011082
4
4
MACOM Technology Solutions Inc. (MACOM) and its affiliates reserve the right to make changes to the product(s) or information contained herein without notice.
Visit www.macom.com for additional data sheets and product information.
For further information and support please visit:
https://www.macom.com/support
DC-0019302
4
Tape & Reel Information
Parameter Units Value
Qty per reel 300
Reel Size mm 330
Tape Width mm 32.00
Pitch mm 24.00
Ao mm 18.5
Bo mm 18.5
Ko mm 7.0
Orientation F30
Reference Application Note ANI-019 for orientation
Dimensions Orientation
Pin #1
Identifier
Reflection-less Low Pass Filter
5 - 684 MHz
Rev. V2
MAFL-011082
5
5
MACOM Technology Solutions Inc. (MACOM) and its affiliates reserve the right to make changes to the product(s) or information contained herein without notice.
Visit www.macom.com for additional data sheets and product information.
For further information and support please visit:
https://www.macom.com/support
DC-0019302
5
MACOM Technology Solutions Inc. All rights reserved.
Information in this document is provided in connection with MACOM Technology Solutions Inc ("MACOM")
products. These materials are provided by MACOM as a service to its customers and may be used for
informational purposes only. Except as provided in MACOM's Terms and Conditions of Sale for such products or
in any separate agreement related to this document, MACOM assumes no liability whatsoever. MACOM
assumes no responsibility for errors or omissions in these materials. MACOM may make changes to
specifications and product descriptions at any time, without notice. MACOM makes no commitment to update
the information and shall have no responsibility whatsoever for conflicts or incompatibilities arising from future
changes to its specifications and product descriptions. No license, express or implied, by estoppels or otherwise,
to any intellectual property rights is granted by this document.
THESE MATERIALS ARE PROVIDED "AS IS" WITHOUT WARRANTY OF ANY KIND, EITHER EXPRESS OR
IMPLIED, RELATING TO SALE AND/OR USE OF MACOM PRODUCTS INCLUDING LIABILITY OR
WARRANTIES RELATING TO FITNESS FOR A PARTICULAR PURPOSE, CONSEQUENTIAL OR
INCIDENTAL DAMAGES, MERCHANTABILITY, OR INFRINGEMENT OF ANY PATENT, COPYRIGHT OR
OTHER INTELLECTUAL PROPERTY RIGHT. MACOM FURTHER DOES NOT WARRANT THE ACCURACY
OR COMPLETENESS OF THE INFORMATION, TEXT, GRAPHICS OR OTHER ITEMS CONTAINED WITHIN
THESE MATERIALS. MACOM SHALL NOT BE LIABLE FOR ANY SPECIAL, INDIRECT, INCIDENTAL, OR
CONSEQUENTIAL DAMAGES, INCLUDING WITHOUT LIMITATION, LOST REVENUES OR LOST PROFITS,
WHICH MAY RESULT FROM THE USE OF THESE MATERIALS.
MACOM products are not intended for use in medical, lifesaving or life sustaining applications. MACOM
customers using or selling MACOM products for use in such applications do so at their own risk and agree to
fully indemnify MACOM for any damages resulting from such improper use or sale.