DG506A_MIL/507A_MIL
Vishay Siliconix
Document Number: 70066
S-00405—Rev. D, 21-Feb-00 www.vishay.com S FaxBack 408-970-5600
5-3
Test Conditions
Unless Otherwise Specified A Suffix
–55 to 125_C
Parameter Symbol V+ = 15 V, V– = –15 V
VIN = 2.4 V, 0.8 VfTempbMindTypcMaxdUnit
Analog Switch
Analog Signal RangeeVANALOG Full –15 15 V
Drain-Source
On-Resistance rDS(on) VD = "10 V, IS = –200 mARoom
Full 240 400
500 W
rDS(on) MatchinggDrDS(on) –10 V < VS < 10 V Room 6 %
Source Off
Leakage Current IS(off) VS = "10 V, VD = #10 V
VEN = 0 V Room
Full –1
–50 1
50
Drain Off
VD= #10 V
DG506A_MIL Room
Full –10
–300 10
300
Leakage Current
D(off)
S = "
VEN = 0 V DG507A_MIL Room
Full –5
–200 5
200 nA
Drain On
DG506A_MIL Room
Full –10
–300 10
300
Leakage Current
D(on)
S =
D = "
DG507A_MIL Room
Full –5
–200 5
200
Digital Control
Logic Input Current
VA = 2.4 V Room
Full –10
–30
Input V oltage High
AH VA = 15 V Room
Full 10
30 mA
Logic Input Current
Input V oltage Low IAL VEN = 0 V, 2.4 V, VA = 0 V Room
Full –10
–30
Dynamic Characteristics
Transition Time tTRANS See Figure 2 Room 0.6 1.0
Break-Before-Make T ime tOPEN See Figure 4 Room 0.2
Enable T urn-On T ime tON(EN)
Room 1 1.5 m
Enable T urn-Of f Time tOFF(EN)
ee
gure
Room 0.4 1.0
Charge Injection Q Room 6 pC
Off IsolationhOIRR VEN = 0 V, RL = 1 kW, CL = 15 pF
VS = 7 VRMS, f = 500 kHz Room 68 dB
Source Off Capacitance CS(off) VEN = 0 V, VS = 0 V, f = 140 kHz Room 6
VEN = 0 V
DG506A_MIL Room 45 pF
ra
n
apac
ance
D(off)
D =
f = 140 kHz DG507A_MIL Room 23
Power Supplies
Positive Supply Current I+
=
=
Room 1.3 2.4
Negative Supply Current I–
EN =
,
A =
Room –1.5 –0.7
Notes:
a. Refer to PROCESS OPTION FLOWCHART.
b. Room = 25_C, Full = as determined by the operating temperature suffix.
c. T ypical values are for DESIGN AID ONL Y, not guaranteed nor subject to production testing.
d. The algebraic convention whereby the most negative value is a minimum and the most positive a maximum, is used in this data sheet.
e. Guaranteed by design, not subject to production test.
f. VIN = input voltage to perform proper function.
g. DrDS(on) +ǒrDS(on)MAX – rDS(on)MIN
rDS(on)AVE Ǔ
h. Off isolation +20 log VD
VS,V
S+input to off switch, VD+output due to VS.