SPECIFICATION
18WAC-DC High Reliability IndustrialAdaptor GST18A series
File Name:GST18A-SPEC 2015-06-24
ORDER NO.
SAFETY MODEL NO.
DC VOLTAGE Note.2
RATED CURRENT
CURRENT RANGE
RATED POWER (max.)
RIPPLE & NOISE (max.) Note.3
OUTPUT
SETUP, RISE, HOLD UP TIME
VOLTAGE RANGE Note.7
FREQUENCY RANGE
EFFICIENCY (Typ.)
AC CURRENT
INPUT
ENVIRONMENT
INRUSH CURRENT (max.)
LEAKAGE CURRENT(max.)
SAFETY STANDARDS
SAFETY &
EMC
(Note. 8)
WORKING TEMP.
WORKING HUMIDITY
STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
MTBF
DIMENSION
OTHERS
NOTE
PACKING
PROTECTION
5V 7.5V 9V 12V 15V 18V 24V 28V 48V
GST18A05
GST18A05-P1J
GST18A09-P1J
GST18A15-P1J
GST18A24-P1J
GST18A48-P1J
GST18A07-P1J
GST18A12-P1J
GST18A18-P1J
GST18A28-P1J
GST18A07 GST18A09 GST18A12 GST18A15 GST18A18 GST18A24 GST18A28 GST18A48
3.0A 2.0A 2.0A 1.50A 1.20A 1.0A 0.75A 0.64A 0.375A
0 ~ 3.0A 0 ~ 2.0A 0 ~2.0A 0 ~ 1.20A 0 ~ 1.0A
80mVp-p 80mVp-p 80mVp-p 100mVp-p 150mVp-p 180mVp-p 240mVp-p 240mVp-p
VOLTAGE TOLERANCE Note.4
LINE REGULATION Note.5
LOAD REGULATION Note.6
±5.0% ±5.0% ±5.0% ±3.0% ±3.0% ±3.0% ±2.0% ±2.0% ±2.0%
±1.0% ±1.0% ±1.0% ±1.0% ±1.0% ±1.0% ±1.0% ±1.0% ±1.0%
±5.0% ±5.0% ±5.0% ±3.0% ±3.0% ±3.0% ±2.0% ±2.0% ±2.0%
47 ~ 63Hz
0.75mA / 240VAC
UL60950-1, CSA C22.2, TUV EN60950-1, BSMI CNS14336, CCC GB4943, PSE J60950-1 approved
WITHSTAND VOLTAGE
ISOLATION RESISTANCE
I/P-O/P:4242VDC , I/P-FG:2121VDC
I/P-O/P, I/P-FG:100M Ohms / 500VDC / 25 / 70% RH℃
500Khrs min. MIL-HDBK-217F(25 )℃
-30 ~ +70 (Refer to "Derating Curve")℃
20% ~ 90% RH non-condensing
-40 ~ +85 , 10 ~ 95% RH℃
±℃℃0.03% / (0 ~ 50 )
10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes
93*54*36mm (L*W*H)
209g; 60pcs/13.5Kg/1.12CUFT
CONNECTOR
PLUG
CABLE See page 3 ; Other type available by customer requested
See page 3 ; Other type available by customer requested
15W 15W 18W 18W
0 ~ 1.50A
18W 18W 18W
0 ~ 0.75A
18W
0 ~ 0.64A
18W
0 ~ 0.375A
1.All parameters are specified at 230VAC input, rated load, 25 70% RH ambient. ℃
2.DC voltage: The output voltage set at point measure by plug terminal & 50% load.
3.Ripple & noise are measured at 20MHz by using a 12" twisted pair terminated with a 0.1uf & 47uf capacitor.
4.Tolerance: includes set up tolerance, line regulation, load regulation.
5.Line regulation is measured from low line to high line at rated load.
6.Load regulation is measured from 10% to 100% rated load.
7.Derating may be needed under low input voltage. Please check the derating curve for more details.
8.The power supply is considered as an independent unit, but the final equipment still need to re-confirm that the whole system complies with the
EMC directives. For guidance on how to perform these EMC tests, please refer to EMI testing of component power supplies.
(as available on http://www.meanwell.com)
Compliance to EN55022 class B EN61000-3-2,3, FCC PART 15 / CISPR22 class B, CNS13438 class B, , GB9254, GB17625.1
Compliance to EN61000-4-2,3,4,5,6,8,11, light industry level, criteria A
OVERLOAD
OVER VOLTAGE
110 ~ 150% rated output power
Protection type : Hiccup mode, recovers automatically after fault condition is removed
Protection type : Clamp by zener diode, output short
EMC IMMUNITY
EMC EMISSION
80mVp-p
85 ~ 264VAC
0.5A / 115VAC 0.3A / 230VAC
35A / 115VAC 65A / 230VAC
110 ~ 140% rated output voltage
1000ms, 30ms, 50ms/230VAC 1500ms, 30ms, 15ms/115VAC at full load
81% 85% 85% 86% 87% 88% 88% 88.5% 89%