http://www.tracopower.com Page 4 of 9
All specifications valid at nominal input voltage, full load and +25°C after warm-up time unless otherwise stated.
AC/DC Power Modules
TPM Series 5 to 40 Watt
General Specifications
Temperature ranges – Operating –25°C to +70°C max.
– Case temperature +95°C max.
– Derating TPM 5/ 10/ 15 single output models: 2 %/K above 55°C
TPM 5/ 10/ 15 dual output models: 3 %/K above 55°C
TPM 10/ 15 triple output models: 5 %/K above 55°C
TPM 30/ 40 single output models: 2 %/K above 50°C
TPM 30 dual output models: 3 %/K above 50°C
TPM 30 triple output models: 5 %/K above 50°C
– Storage (non operating) –45°C to +100°C
Temperature coefficient 0.01 %/K
Efficiency 55 – 85 % (depending on model)
Humidity (non condensing) 95 % rel max.
Switching frequency (Puls width modulation PWM) TPM 5 models: 125 kHz typ.
TPM 10 / 15 / 30 models: 90 kHz typ.
TPM 40 models: 70 kHz typ.
Hold-up time – Vin = 115 VAC 50 ms min.
– Vin = 230 VAC 50 ms min.
I/O isolation voltage (50 Hz 60 sec.) 3‘300 VAC
Reliability, calculated MTBF (MIL-HDBK-217F, at +25°C, ground benign) >800‘000 h
EMI / RFI conducted EN 55022, class B, FCC part 15, level B
EMC compliance – Electrostatic discharge ESD IEC/EN 61000-4-2 4 kV / 8 kV
– RF field susceptibility IEC/EN 61000-4-3 10 V/m
– Electrical fast transients/bursts on mainsline IEC/EN 61000-4-4 2 kV
– Surge IEC/EN 61000-4-5 2 kV sym.
– Immunity to conducted RF disturbances IEC/EN 61000-4-6 10 V
– Immunity to voltage dips, short interruptions
and voltage variations IEC/EN 61000-4-11
Safety Class II to IEC/EN 60536
Safety standards UL 1950, IEC/EN 60950
Safety approvals – UL/cUL www.ul.com > UL File no.: e188913
Casing material CELANEX 2360 FL (UL94V-0 rated)