RAY-90
Issue 3
17th April 2007
Page 1 of 2
The complete requirements for procuring the wire described herein shall consist of this document.
Copper
Plastic Former Tin Plated
Minimum Nom.
Weight #
Carriers Ends % (kg/ km)
16 5 90.0 13
16 7 90.0 17
24 6 90.0 21
24 7 90.0 25
24 9 90.0 52
24 10 90.0 65
24 11 90.0 100
36 7 90.0 165
36 9 90.0 207
36 9 90.0 310
NOTE: The last number of the part depicts the nominal internal diameter of the braid,
e.g. RAY-90-5.0 Tin Plated Copper Braid with 5.00 mm nominal internal diameter.
'#' The nominal weight value excludes weight of former
PERFORMANCE To be tested to and meet the requirements of the issue in effect of WSD 1922.
REQUIREMENTS:
APPROVAL: Electronic sign off - no signatures will appear.
RAYBRAID®is a registered trademark of Tyco Electronics Corporation.
©2007 Tyco Electronics Corporation. All International Rights Reserved.
Specification Control Drawing
RAYBRAID
PLATED COPPER BRAID
Page 2 is for internal use only
RAY-90-30.0
RAY-90-25.0
RAY-90-3.0
RAY-90-4.0
Braid Detail
Number of
RAY-90-10.0
RAY-90-12.5
RAY-90-20.0
RAY-90-5.0
RAY-90-15.0
RAY-90-6.0
36/ 0.13
36/ 0.13
36/ 0.13
Part
Number Strand
size
AWG/ mm
36/ 0.13
34/ 0.16
34/ 0.16
32/ 0.20
30/ 0.25
30/ 0.25
28/ 0.32
This specification sheet takes precedence over documents referenced
herein. As Tyco Electronics UK Ltd. reserve the right to make changes in
construction without notice please contact Tyco Electronics UK Ltd to
ensure that this document is the latest issue.
Tyco Electronics
UK Ltd
Faraday Road
Dorcan
SWINDON
SN3 5HH
Tel: (01793) 528171
Telex: 449409
Registration Number: 550926
London, England
This drawing and the information set forth hereon are the property of Tyco
Electronics UK Ltd, and are to be held in trust and confidence. Publication,
duplication, disclosure or use for any purpose not expressly authorised in
writing by Tyco Electronics UK Ltd is prohibited.