https://www.phoenixcontact.com/us/products/2692322 Bus coupler - IL PB BK DI8 DO4/EF-PAC - 2692322 Please be informed that the data shown in this PDF Document is generated from our Online Catalog. Please find the complete data in the user's documentation. Our General Terms of Use for Downloads are valid (http://phoenixcontact.com/download) Inline Modular PROFIBUS bus coupler DP/V1, 8 inputs: 24 V DC, 4 outputs: 24 V DC, 500 mA, 2, 3-conductor connection method Product description The bus coupler for the PROFIBUS has 4 digital outputs and 8 digital inputs. This package contains all the necessary Inline connectors for connecting the supply and the I/Os. For project planning, the relevant GSD (device master data) file can be downloaded in the download area of Phoenixcontact.com. The Inline terminals can be labeled using pull-out labeling fields. The fields have insert cards that can be labeled individually to suit the application. Additionally, there is the ZBFM-6... Zack marker strip for labeling the terminal points. Product Features IO-Link calls supported Operation of PROFIsafe devices Key commercial data Packing unit 1 pc Weight per Piece (excluding packing) 340.0 GRM Custom tariff number 85389091 Country of origin Germany Technical data Note Utilization restriction EMC: class A product, see manufacturer's declaration in the download area Dimensions Width 80 mm Height 119.8 mm Depth 71.5 mm Note on dimensions Specfications with connectors 09/03/2014 Page 1 / 7 https://www.phoenixcontact.com/us/products/2692322 Bus coupler - IL PB BK DI8 DO4/EF-PAC - 2692322 Technical data Ambient conditions Ambient temperature (operation) -25 C ... 60 C Ambient temperature (storage/transport) -40 C ... 85 C Permissible humidity (operation) 10 % ... 95 % (according to DIN EN 61131-2) Permissible humidity (storage/transport) 10 % ... 95 % (according to DIN EN 61131-2) Air pressure (operation) 70 kPa ... 106 kPa (up to 3000 m above sea level) Air pressure (storage/transport) 70 kPa ... 106 kPa (up to 3000 m above sea level) Degree of protection IP20 General Weight 320 g Note on weight specifications with connectors Mounting type DIN rail Protection class III, IEC 61140, EN 61140, VDE 0140-1 Conformance with EMC directives Noise immunity test in accordance with EN 61000-6-2 Electrostatic discharge (ESD) EN 6100042/IEC 6100042 Criterion B; 6 kV contact discharge, 8 kV air discharge Noise immunity test in accordance with EN 61000-6-2 Electromagnetic fields EN 6100043/IEC 6100043 Criterion A; Field intensity: 10 V/m Noise immunity test in accordance with EN 61000-6-2 Fast transients (burst) EN 6100044/IEC 6100044 Criterion A; all interfaces 1 kVCriterion B; all interfaces 2 kV Noise immunity test in accordance with EN 61000-6-2 Transient surge voltage (surge) EN 6100045/IEC 6100045 Criterion B; supply lines DC: 0.5 kV/0.5 kV (symmetrical/asymmetrical); fieldbus cable shield 1 kV Noise immunity test in accordance with EN 61000-6-2 Conducted interference EN 6100046/IEC 6100046 Criterion A; Test voltage 10 V Noise emission test as per EN 61000-6-4 EN 55011 Class A Mechanical tests Vibration resistance in acc. with EN 60068-2-6/IEC 60068-2-6 5g Shock in acc. with EN 60068-2-27/IEC 60068-2-27 Operation: 25g, 11 ms duration, semi-sinusoidal shock impulse Diagnostics messages Short-circuit / overload of the digital outputs Yes Sensor supply failure Yes Interfaces Fieldbus system PROFIBUS DP Designation PROFIBUS DP Connection method D-SUB-9 female connector Transmission speed 9,6 kBit/s ... 12 MBit/s Number of positions 9 Fieldbus system Lokalbus Designation Inline local bus 09/03/2014 Page 2 / 7 https://www.phoenixcontact.com/us/products/2692322 Bus coupler - IL PB BK DI8 DO4/EF-PAC - 2692322 Technical data Interfaces Connection method Inline data jumper Transmission speed 500 kBit/s / 2 MBit/s (Automatic detection, no combined system) System limits of the bus coupler Designation System limits of the bus coupler Amount of process data max. 488 Byte (per station) max. 244 Byte (Input) max. 244 Byte (Output) Number of parameter data max. 244 Byte (including 14 bytes for the bus coupler, DP/V1, and the local inputs and outputs) Number of configuration data max. 244 Byte (including 5 bytes for the local inputs and outputs) Number of supported devices max. 63 (per station) Number of local bus devices that can be connected max. 61 (on board I/Os are two devices) Number of devices with parameter channel max. 16 Number of branch terminals with remote bus branch 0 Response time of I/Os typ. 4 ms (aligned I/Os; transmission speed: PROFIBUS 1.5 Mbps, local bus 500 kbps) Power supply for module electronics Connection method Spring-cage connection Designation Bus coupler supply UBC; Communications power UL (7.5 V) and the analog supply UANA (24 V) are generated from the bus coupler supply. Supply voltage 24 V DC (via Inline connector) Supply voltage range 19.2 V DC ... 30 V DC (including all tolerances, including ripple) Current consumption max. 0.98 A (from UBK) Power loss typ. 1.7 W (entire device) Communications power UL 7.5 V DC Current consumption 0.8 A Power consumption typ. 1.7 W Inline potentials Communications power UL 7.5 V DC 5 % Power supply at UL max. 0.8 A DC Main circuit supply UM 24 V DC Supply voltage range UM 19.2 V DC ... 30 V DC (including all tolerances, including ripple) Power supply at UM max. 8 A DC (Sum of UM + US) Current consumption from UM max. 8 A DC Segment supply voltage US 24 V DC Supply voltage range US 19.2 V DC ... 30 V DC (including all tolerances, including ripple) 09/03/2014 Page 3 / 7 https://www.phoenixcontact.com/us/products/2692322 Bus coupler - IL PB BK DI8 DO4/EF-PAC - 2692322 Technical data Inline potentials Power supply at US max. 8 A DC (Sum of UM + US) Current consumption from US max. 8 A DC I/O supply voltage UANA 24 V DC Supply voltage range UANA 19.2 V DC ... 30 V DC (including all tolerances, including ripple) Power supply at UANA max. 0.5 A DC Digital inputs Input name Digital inputs Connection method Inline connector 2, 3-wire Number of inputs 8 (EN 61131-2 type 1) Typical response time approx. 500 s Protective circuit Protection against polarity reversal Polarity protection diode Input voltage 24 V DC Input voltage range "0" signal -30 V DC ... 5 V DC Input voltage range "1" signal 15 V DC ... 30 V DC Nominal input current at UIN typ. 3 mA Typical input current per channel typ. 3 mA Delay at signal change from 0 to 1 2.9 ms Delay at signal change from 1 to 0 2.9 ms Digital outputs Output name Digital outputs Connection method Inline connector 2, 3-wire Number of outputs 4 Protective circuit Short-circuit and overload protection Free running circuit Output voltage 24 V DC -1 V (At nominal current) Nominal output voltage 24 V DC Maximum output current per channel 500 mA Maximum output current per module / terminal block 2A Maximum output current per module 2A Nominal load, inductive 12 VA (1.2 H; 48 ) Nominal load, lamp 12 W Nominal load, ohmic 12 W 09/03/2014 Page 4 / 7 https://www.phoenixcontact.com/us/products/2692322 Bus coupler - IL PB BK DI8 DO4/EF-PAC - 2692322 Classifications eCl@ss eCl@ss 4.0 27250302 eCl@ss 4.1 27250302 eCl@ss 5.0 27250302 eCl@ss 5.1 27242604 eCl@ss 6.0 27242604 eCl@ss 7.0 27242604 eCl@ss 8.0 27242608 ETIM ETIM 2.0 EC001430 ETIM 3.0 EC001599 ETIM 4.0 EC001599 ETIM 5.0 EC001599 UNSPSC UNSPSC 6.01 43172015 UNSPSC 7.0901 43201404 UNSPSC 11 43172015 UNSPSC 12.01 43201404 UNSPSC 13.2 43201404 Approvals Approvals Approvals LR / GL / BV / DNV / ABS / RINA / PROFIBUS / GL-SW / UL Recognized / cUL Recognized / GL / cULus Recognized Ex Approvals ATEX Approvals submitted Approval details LR 09/03/2014 Page 5 / 7 https://www.phoenixcontact.com/us/products/2692322 Bus coupler - IL PB BK DI8 DO4/EF-PAC - 2692322 Approvals GL BV DNV ABS RINA PROFIBUS GL-SW UL Recognized cUL Recognized GL cULus Recognized Drawings 09/03/2014 Page 6 / 7 https://www.phoenixcontact.com/us/products/2692322 Bus coupler - IL PB BK DI8 DO4/EF-PAC - 2692322 Connection diagram Dimensioned drawing PWR DO4 DI4 DI4 1 2 3 4 119,8 IN6 24 V DC + (US) 1.1 2.1 1.1 2.1 1.1 2.1 3.1 4.1 +24 V 1.2 2.2 1.2 2.2 3.2 4.2 1.3 2.3 1.3 2.3 3.3 4.3 1.4 2.4 1.4 2.4 1.4 2.4 3.4 4.4 24 V DC (UM) + PROFIBUS - DP +24 V IN8 71,5 2.2 2.3 OUT2 1.2 1.3 OUT3 24 V DC + (UBK) - Phoenix Contact 2014 (c) - all rights reserved http://www.phoenixcontact.com 09/03/2014 Page 7 / 7