circuit breakers Thermal Circuit Breaker, rocker actuated, 1-, 2- or 3-pole TA35 1-pole TA35 2-pole with CZM25 IP 65, antibacterial cover according ISO 22196 TA35 3-pole (pending) Description Applications - - - - - - - - - - - - - - - Thermal circuit breaker 1-, 2- or 3-pole Supplementary protector for general industrial use Positively trip-free release Snap-in mounting Version with illuminated rocker Different rocker colours Antibacterial cover IP65 CZM25 Dead-Man-version (Momentary switch) Power tools Industrial equipment Equipment for building construction Medical equipment Cleaning equipment Power generators Commercial and household kitchen appliances Weblinks Approvals: http://www.schurter.com/approvals RoHS: http://www.schurter.com/rohs Standards - IEC 60934 - UL 1077 - CSA C22.2 235 - GB 17701 (pending) Technical Data Rated voltage Ue 1-pole 2-pole 3-pole AC 240 V / 50/60 Hz DC 32 V AC 240 V / 50/60 Hz DC 60 V AC 415 Y/240 V / 50/60 Hz Rated current In 1- / 2-pole 3-pole 0.05 - 20 A 0.05 - 12 A Conditional short circuit Inc 1- / 2-pole, AC 240 V 3-pole, AC 415 V 0.05...20 A: 2000 A, SC (C1) 0.05...12 A: 2000 A Degree of protection Accessible range Terminal side IP 40 IP 00 Dielectric strength 50 Hz Impulse 1.2/50 s > 2500 V > 4000 V Insulation resistance DC 500 V > 100 MOhm Endurance (typical) Mechanical 50'000 cycles AC: 1 x In, cos phi 0.6 50'000 cycles DC: 1 x In, L/R = 2...3ms 50'000 cycles Overload IEC 60934 UL 1077 min. 40 cycles @ 6 x In, cos phi 0.6 min. 50 cycles @ 1.5 x In, cos phi 0.75 (OLO) Admissible ambient air temperature -30 C to +60 C Resistance to vibration IEC 60068-2-6, Test Tc 10...60 Hz: 0.75 mm 60...500 Hz: 10 G Shock resistance 2 IEC 60068-2-27, Test Ea 30 G / 18 ms Type of tripping Thermal positively trip free Weight 19 g 32 g 45 g 1-pole 2-pole 3-pole Max. switching capacity 1-, 2-pole for switch only types 3-pole (without bimetal) circuit breakers 20 A 12 A TA35 www.schurter.com/pg17_18_19 Tripping characteristics [ min ] [ sec ] 10'000 [ min ] [ sec ] 10'000 Type Rated current TA35 <3 A (TC-1) 1, 2 pole 60 20 Ambient temp. 1000 10 60 3 pole 2000 30 Type Rated current 20 5 Ambient temp. 1000 10 500 1,2,3 pole 2000 30 +23 C TA35 >3-20A (TC-1) (3 pole, max. 12A) +23 C 500 5 200 200 100 1 100 1 50 20 20 10 10 5 5 2 2 1 1 0,5 0,5 Tripping time Tripping time 50 0,3 0,2 0,1 1,05 1,35 2 3 4 5 8 10 0,2 0,1 1,05 1,35 [ x In ] Multiple of rated current 0,3 2 3 Multiple of rated current 4 5 8 10 [ x In ] The above tripping characteristics apply to symmetrical overloads on all poles on the TA35 only. At asymmetric overloads on multi-pole types, the tripping characteristic will change. - If a 2-pole type TA35 is loaded at one pole only, the tripping current will be shifted by factor 1.05 (TC-2). - If a 3-pole type TA35 is loaded at one pole only, the tripping current will be shifted by factor 1.10 (TC-2). To meet the above tripping characteristic at asymmetric overloads on multi-pole types, the value of the rated current of the CBE has to be multiplied by the factor mentioned above. Effect of ambient temperature The unit is calibrated for an ambient temperature of +23 C. To determine the rated current for lower or higher ambient temperature, use a correction factor from the table below. Ambient temperature [C] Correction factor 1-pole 2-pole 3-pole -30 0.77 0.76 0.76 -20 0.81 0.81 0.81 0 0.90 0.90 0.90 +23 1.00 1.00 1.00 +40 1.03 1.03 1.06 +50 1.04 1.04 1.10 +60 1.06 1.06 1.14 Example for 2-pole type: Rated current at +23 C Ambient temperature Correction factor Chosen rated current at +40 C ambient temperature: 5.0 A +50 C 1.04 5 A x 1.04 = 5.2 A circuit breakers 3 circuit breakers Standard rated currents and typical internal resistance Code In Ri [Ohm] J01 0.1 70.000 J05 0.5 2.750 J10 1.0 0.720 J15 1.5 0.340 J20 2.0 0.187 J25 2.5 0.115 J28 2.8 0.089 030 3.0 0.059 040 4.0 0.059 050 5.0 0.044 060 6.0 0.028 070 7.0 0.0142 080 8.0 0.0142 100 10.0 0.0109 120 12.0 0.0086 140 14.0 0.0072 150 15.0 0.0056 160 16.0 0.0056 180 18.0 0.0052 200 20.0 0.0052 Unprotected poles (without bimetal) 2.2 m Approvals UL UL 1077 Rated currents Rated voltage AC Rated voltage DC 0.05...20 A 240 V 32 V 2 0.05...20 A 240 V 60 V 3 0.05...12 A 415 Y/240 V -- UL 1 0.05...20 A 240 V 32 V 2 0.05...20 A 240 V 60 V 3 0.05...12 A 415 Y/240 V -- VDE CSA C22.2 235 1 0.05...20 A 240 V 32 V 2 0.05...20 A 240 V 60 V 3 0.05...12 A 415 Y/240 V -- CQC IEC 60934 1* 0.05...20 A 240 V 32 V GB 17701 2* 0.05...20 A 240 V 60 V 3* 0.05...12 A 415 Y/240 V -- * Approvals pending 4 # of poles 1 Actual information about approvals can be found on: www.schurter.com/approvals. circuit breakers TA35 www.schurter.com/pg17_18_19 Order code Number of switched poles 1-pole Number of protected poles 0 1 0 LINE P1 LINE P1 2-pole 3-pole 1 2 0 LINE LINE P1 P2 7 8 P1 P1 LINE P2 P3 7 8 9 LINE P2 P1 P2 3 LINE P1 4 4 Switch CFC Switch illuminated LOAD LOAD CD1 CGT CEC 5 6 LOAD 415 V CK1 240 V CF2 C2F C02 C12 C32 120 V CF4 C4F C04 C14 C34 24 V CF7 C7F C07 C17 C37 12 V CF8 C8F C08 C18 C38 5V CF9 C9F C09 C19 C39 CGC P3 LOAD CKD Momentary without switch illumination CBC 5 LOAD 8 CKC without Illumination CFT 4 4 LOAD 7 LOAD P2 CBT CBD CET CED CLC CLD Other versions on request TA35- CBD W F 120 - C0 CZM21 Only factory mounted accessories are integreated in the Order Code. No other features Accessories, factory mounted (optional) Colours Switch frontRocker W B R G Y X 1 3 4 6 7 black black black black black black black black black black black non-illuminated illuminated white black red green yellow orange - - - - - - - - - - - clear transparent red transparent green transparent orange transparent blue transparent Other colours on request SurfaceIllustration 0 L printed l M printed OFF OFF printed l K white 0 ON H printed Colour of print white 0 l ON embossed Other legends on request Transparent cover, 2-pole, IP65 CZM23 Raised collar with transparent cover, 2-pole, IP65 CZM24 Raised collar without cover, 2-pole, IP40 CZM25 Transparent cover antibacterial, 2-pole, IP65 antibacterial according ISO 22196 Without thermal overload protection: code C00 Rocker legend F CZM21 black black With thermal overload protection: rated current In (A) In Code In Code In Code In Code 0.05 0.1 0.2 0.3 0.4 0.5 0.8 Z05 J01 J02 J03 J04 J05 J08 1.0 1.2 1.5 2.0 2.5 3.0 3.5 J10 J12 J15 J20 J25 030 035 4.0 5.0 6.0 7.0 8.0 10.0 12.0 040 050 060 070 080 100 120 14.0 15.0 16.0 18.0 20.0 140 * 150 * 160 * 180 * 200 * Other rated currents on request circuit breakers * 3-pole max. 12A 5 circuit breakers Dimensions TA35, 1-Pole 17.5 34 9.9 14.5 +0.2 0 7.2 1.7 36 LINE 4 34 P1 10.6 7 33.5 5 44.1 7.8 L +0.2 0 +0.3 Label 2.8 x 0.4 mm (illuminated version only) 21.3 12.5 2.3 Panel thickness 1.0 to 4.0 mm 14.5 33.8 6.3 x 0.8 mm TA35, 1-Pole, Accessories CZZ11, Srew-on Collar with Cover, IP65 36 17.5 34 9.9 LINE 4 27.8 44 0.15 21.3 44 0.15 +0.2 0 34 33.5 10.6 23.5 13.8 Quick connect terminal IEC 61210 A2.8-0.4 5.7 P1 3 7 44.1 7.8 5 52 6 + +0.3 Label L +0.2 0 20 9.7 9.8 10.3 7.2 1.7 34 14.5 12.5 2.3 14.5 33.8 Quick connect terminal IEC 61210 A6.3-0.8 circuit breakers 2.5 Part. No. 4435.0052 Panel thickness 1.0 to 4.0 mm TA35 www.schurter.com/pg17_18_19 36 29 34 20.9 26 +0.2 0 7.2 1.7 TA35, 2-Pole 4 34 33.5 P1 10.6 10.5 7 44.1 LINE L +0.2 0 +0.3 Label 21.3 Panel thickness 1.0 to 4.0 mm 11 6.1 2.3 23.5 33.8 26 6.3 x 0.8 mm TA35, 2-Pole, Accessories CZM21 / CZM25, Factory Mounted Transparent Cover, IP65 32 39 24.1 27.9 +0.2 0 9.5 2.3 26 P1 +0.2 0 34 10.5 4 10.6 7 LINE LINE L 43.9 33.4 +0.3 6.3 x 0.8 mm 11 6.1 2.3 21.3 33.8 26 circuit breakers Panel thickness 1.0 to 3.5 mm 7 circuit breakers CZM23, Factory Mounted Raised Collar with Transparent Cover, IP65 32 39 29 36 +0.2 0 8.5 9.4 26 4 +0.2 0 34 10.5 P1 10.6 7 LINE LINE L 43.9 33.4 +0.3 11 6.3 x 0.8 mm 6.1 2.3 21.3 Panel thickness 1.0 to 3.5 mm 33.8 26 CZM24, Factory Mounted Raised Collar without Cover, IP40 29 36 +0.2 0 8.5 26 4 +0.2 0 34 10.5 P1 10.6 7 LINE LINE L 43.9 33.4 +0.3 11 6.3 x 0.8 mm 6.1 2.3 21.3 Panel thickness 1.0 to 3.5 mm 33.8 26 CZZ21, Screw-on Collar with Cover, IP65 Part. No. 4435.0053 36 31 44 0.15 44 0.15 +0.2 0 11 6.1 2.3 23.5 33.8 Quick connect terminal IEC 61210 A6.3-0.8 26 circuit breakers 2.5 +0.3 P1 10.6 21.3 +0.2 0 34 33.5 44.1 LINE 5.7 4 3 7 10.5 24.6 35 L 27.8 26 Label 52 8 29 20.9 1.7 9.7 34 7.2 9.8 10.3 34 Panel thickness 1.0 to 4.0 mm TA35 www.schurter.com/pg17_18_19 TA35, 3-Pole 40.5 34 31.9 37.5 +0.2 0 33.5 44.1 LINE 4 P1 10.6 10.5 7 +0.2 0 Label L 34 7.2 1.7 36 21.3 11 2.3 11 6.1 Panel thickness 1.0 to 4.0 mm 34.5 33.8 37.4 6.3 x 0.8 mm TA35, 3-Pole, Accessories CZZ31, Screw-on Collar with Cover, IP65 Part. No. 4435.0054 42 34 40.5 9.7 9.8 38 31.9 1.7 34 7.2 52 27.8 21.3 38 0.15 2.3 44 0.15 Quick connect terminal IEC 61210 A6.3-0.8 +0.2 0 2.5 11 11 6.1 34.5 33.8 37.5 10.6 3 P1 5.7 44.1 LINE 46.5 36.1 4 10.5 7 33.5 Label L 34 +0.2 0 +0.3 44 10.3 36 Panel thickness 1.0 to 4.0 mm 37.4 circuit breakers 9