703
Dimensions are shown for
reference purposes only.
Dimensions are in inches over
(millimeters) unless otherwise
specified.
Specifications and availability
subject to change.
www.tycoelectronics.com
Technical support:
Refer to inside back cover.
P&B
Catalog 1308242
Issued 3-03
R10 series
General Purpose
Dry Circuit to 7.5 Amp
Multicontact AC or DC Relay
• R10-E – Clear Dust Cover Version
• R10-R – Sealed, Immersion Cleanable Type
• R10S – Super Sensitive, Logic Compatible
Coil Data @ 25°C (also see Coil Data tables)
Voltage: 3 to 115VDC and 6 to 115VAC.
Maximum Coil Power: 2.2 Watts.
Coil Temperature Rise: 30°C per Watt.
Maximum Coil Temperature: 105°C.
Operate Data @ 25°C
Initial Dielectric Strength
Between Open Contacts: 500V rms, for contact codes P and Z.
1,000V rms for contact codes W, X and Y with
coil code V.
Between All Other Conductors: 1,000V rms.
R10 Relays (DC Only) Typical Ranges of Operations
R10 R10SR10-R
Features
• Broad range of coil options provide sensitivity ranging from 25 to 750mW.
• Various contacts switch from dry circuit to 7.5 amps.
• Many mounting and termination options.
File E29244
File LR15734
Capacitance
Between Contacts: 2 pf, typ.
Between Contacts and Coil: 2 pf, typ.
Between Coil and Frame: 30 pf, typ.
Initial Insulation Resistance
Between Mutually Insulated Elements: 1010 ohms @ 25°C, 50% RH.
Consult factory for optional acetal resin material rated 1012 ohms.
Environmental Data
Storage Temperature Range: -55°C to +105°C.
Operating Temperature Range: -55°C to +75°C.
Mechanical Data
Terminal Finish: Tin plating standard.
Weight: 0.8 to 1.4 oz. (23 to 40g) approximately.
R10 Ultra-Sensitive "SS" and "JJ" Typical Ranges of Operation
Multiple of Max. Pull-In Voltage or Current
Operate Time (Milliseconds)
Release Time (Milliseconds)
(Curves for reference only. If specific
values are required, testing is required.)
Typical Operate
and Release Times
(all contact configurations)
Release Time
(no suppression)
50
40
30
20
10
1.0 1.5 2.0 3.0 4.0
10
8
6
4
2
Operate Time
Operate Time
Multiple of Max. Pull-In Voltage or Current
Operate Time (Milliseconds)
Release Time (Milliseconds)
30
(Curves for reference only. If specific
values are required, testing is required.)
25
20
15
10
Release Time
(no suppression)
5
Typical Operate
and Release Time
(all contact configurations)
12
10
8
6
4
2
1.0 1.33 1.5 2.0 2.5 3.0
Contact Data @ 25°C
Arrangements: 1 Form C (SPDT) through 8 Form C (8PDT) See Ordering
Information tables for more details regarding availability.
Contact Materials, Styles & Ratings @ +25°C
Contact Contact Contact Coil Codes Contact Ratings
Code Material Style Available Min. Typ. Max.
W Silver-Cadmium Oxide Single Button V, Q, S, J 500mA - 7.5A‡
X Silver-Cadmium Oxide Single Button V, Q, S, J 500mA - 5A§
Y Fine Silver Single Button All 100mA 2A 3A
Z Fine Silver Bifurcated All 1mA 100mA 2A
P Gold overlay on Silver Bifurcated Crossbar All Dry Circuit 1mA 3A
Ratings are at 28VDC or 155VAC unless otherwise specified. Total load must not
exceed 30A per relay.
‡ Use ungrounded frame for AC loads of 5A or greater. Max.ratings are 7.5A at 115VAC and
4A at 28VDC for coil codes S and J.
§ Use ungrounded frame for AC loads of 5A or greater. Max.ratings are 5A at 115VAC and 3A
at 28VDC for coil codes S and J.
UL Horsepower Contact Ratings (Coil Code V Only)
Contact Code No. of Poles At 110-120VAC At 220-240VAC
W 1, 2, 4 1/8 HP (3.8A) 1/6 HP (2.2A)
X 1, 2, 4, 6 1/20 HP (1.5A) 1/10 HP (1.5A)
Expected Mechanical Life: 100 million operations, typical. (Except contact
Code W: 1,000,000 operations, typical.)
Typical Expected Life For Resistive Loads @ 25°C
Type Current Voltage Contact Style Coil Code Operations††
R10 7.5A 120VAC, 60 Hz. W V,S,J 7.5 · 104
R10 7.5A 28VDC W V 7.5 · 104
R10 5.0A 120VAC, 60 Hz. X V,S,J 5 · 104
R10 5.0A 28VDC X V 5 · 104
R10 4.0A 28VDC W S,J 2 · 104
R10 3.0A 28VDC X S,J 2 · 104
R10 3.0A 28VDC or 120VAC P V,S,J 3 · 104
R10 2.0A 28VDC P,Y,Z V 1.5 · 106
R10 2.0A 28VDC P,Y,Z S,J 6 · 105
R10S 2.0A 28VDC P,Y,Z J 5 · 105
R10 1.0A 28VDC P,Y,Z V,S,J 12 · 106
R10 1.0A 28VDC P,Y,Z SS,JJ 5 · 105
R10S 1.0A 28VDC P,Y,Z J 1 · 106
R10 500mA 28VDC P,Y,Z SS,JJ 5 · 106
R10 100mA 28VDC or 120VAC P,Y,Z V,S,J 1 · 108
R10 100mA 48VDC P,Z SS,JJ 5 · 106
R10 100mA 6VDC P SS,JJ 5 · 107
R10S 100mA 28VDC or 120VAC P,Y,Z J 1 · 106
R10 50mA 6VDC P,Z V,S,J 5 · 107
R10S 30mA 6VDC P,Z J 5 · 106
R10 1mA 6VDC P SS,JJ 5 · 107
†† Relay operated at rated coil voltage or 133% of pick-up current or higher.
Users should thoroughly review the technical data before selecting a product part
number. It is recommended that user also seek out the pertinent approvals files of
the agencies/laboratories and review them to ensure the product meets the
requirements for a given application.