MEDER electronic
www.meder.com
NP-CL Series
Line Sensing
Reed Relays with
Magnetic Shield
RELAY DATA
All Data at 20° C Switch Model -->
Contact Form -->
Switch 81
Form A
Contact Ratings Conditions Min. Typ. Max. Units
Switching Power
Any DC combination of V & A
not to exceed their individual
max.‘s
5 W
Switching Voltage DC or peak AC 90 V
Switching Current DC or peak AC 0.5 A
Carry Current DC or peak AC 1.0 A
Static Contact Resistance w/ 0.5 V & 10mA 200 mΩ
Dynamic Contact Resistance Measured w/ 0.5 V & 50mA ,
1.5 ms after closure 200 mΩ
Insulation Resistance across
Contacts
Across Contact
Coil - Contact
1010
1013 Ω
Breakdown Voltage across
Contact
Across Contact
Coil - Contact
100
1000 VDC
Operation Time incl. Bounce 100 % Overdrive 0.5 ms
Release Time with no coil suppression 0.1 ms
Capacitance Across Contact
Coil - Contact
0.4
2.5 pF
Life Expectance
Switch Voltage 5V - 10 mA DC <10 pF stray cap. 100 106
Cycles
For other load requirements, see test section on Page 152.
Environmental Data
Shock Resistance 1/2 sinus wave duration 11 ms 30 g
Vibration Resistance From 10 - 2000 Hz 10 g
Ambient Temperature 10°C/ minute max. allowable -20 70 oC
Stock Temperature 10°C/ minute max. allowable -25 85 oC
Soldering Temperature 5 sec. 260 oC