Users should evaluate the suitability of this product for their application. Speci cations are subject to change without notice.
Tyco Electronics also reserves the right to make changes in materials or processing, which do not affect compliance with any speci cation, without noti cation to Buyer.
501 Oakside Avenue
Redwood City, California 94063-3800
1-800-227-8816 Fax: 1-650-361-6297
R
Wire & Cable © 2007 Tyco Electronics Corporation. All rights reserved.
THIS SPECIFICATION SHEET TAKES PRECEDENCE OVER DOCUMENTS REFERENCED HEREIN.
REFERENCED DOCUMENTS SHALL BE OF THE ISSUE IN EFFECT ON DATE OF INVITATION FOR BID.
CHEMINAX SPECIFICATION CONTROL DRAWING
ADDITIONAL REQUIREMENTS
CONSTRUCTION DETAILS ELECTRICAL CHARACTERISTICS
THIS SPECIFICATION SHEET FORMS A PART OF THE LATEST ISSUE OF RAYCHEM SPECIFICATION 1200.
Revision:
Date:
DIMENSIONS ARE NOMINAL VALUES IN INCHES UNLESS OTHERWISE
DESIGNATED.
5012E1339
1-23-07
D
50 OHM, AWG 12, 7 STRANDS OF .0296, COAXIAL CABLE
ELECTRICAL
CONDUCTOR RESISTANCE 1.9 ohms/1000 ft. (maximum)
INSULATION RESISTANCE 10,000 megohms (minimum) for 1000 ft.
JACKET FLAWS
SPARK TEST 1.0 kV (rms)
IMPULSE TEST 6.0 kV (peak)
VOLTAGE WITHSTAND
(DIELECTRIC) 1,000 volts (minimum)
ENVIRONMENTAL
FLAMMABILITY Method C
HEAT SHOCK 225°C
LOW TEMPERATURE-COLD BEND -55°C/11.0 inch mandrel
VOLTAGE WITHSTAND
(Post Environmental) 1,000 volts (rms), 1 minute
PHYSICAL
INSULATION (DIELECTRIC)
ELONGATION 200% (minimum)
TENSILE STRENGTH 1800 lbf/in2 (minimum)
JACKET
ELONGATION 100% (minimum)
TENSILE STRENGTH 2000 lbf/in2 (minimum)
JACKET THICKNESS .045 inch (nominal)
SHIELD COVERAGE 90% (minimum)
WEIGHT 109. lbs/1000 ft. (maximum)
CHARACTERISTIC IMPEDANCE 50 ± 2 ohms, Method A
CAPACITANCE 30.0 pF/ft. (nominal)
35.0 pF/ft. (maximum)
VELOCITY OF PROPAGATION 67% (nominal)
Outer jacket color will be white (designated by a "-0" appended to
the part number, e.g. 5012E1339-0) unless otherwise speci ed.
Designate outer jacket color with a dash number in accordance
with MIL-STD-681. Other codes and suf xes may be added to the part
number, as necessary, to capture any additional requirements imposed
by the purchase order.
JACKET
Thermorad® F
DIELECTRIC
Rayolin™ F
Color - Natural
CONDUCTOR
AWG 12, 7 Strands of
.0296, Bare Copper
SHIELD
AWG 33
Bare Copper
.285
± .014
.314
.403
± .007
.089