156
Internet: www.schaevitz.com North America Tel: 800/745-8008
Fax Back System: 916/431-6541 Europe Tel: (01753) 537622
Features
Guaranteed accuracy of less than ±0.08%
F.R.O.
Intrinsically safe option to class EEx ia IIc T4
(Tamb=60°C) BASEEFA CENELEC EN50-020
Rugged stainless steel construction
Pressure ranges: 0-75 psi to 10,000 psi (0 - 5
bar to 0 - 700 bar)
5x overload capacity
IP67, NEMA 4x rated
Long term stability 0.1% F.R.O. per annum
Thermal performance: <0.002% F.R.O./°F
(<0.004% F.R.O./°C)
Select models are CE certified
Applications
Hydraulic and pneumatic controls
Steel and aluminum rolling mills
Pulp and paper mills
Automotive test stands
Power generation
Off-shore oil exploration
The new P9000 Series is the latest addition to the
Schaevitz family of advanced digitally compensated
pressure transducers. The unique design of the P9000
pressure transducer utilizes the proven reliability of strain
gauge technology and innovative digital compensation
electronics. The synergy of these technologies result in an
instrument grade pressure transducer with the highest level
of performance offered by Lucas Control Systems,
Schaevitz Sensors. Available in pressure ranges from 75 psi
to 10,000 psi (5 bar to 700 bar), the P9000 series can be
configured with a variety of pressure ports, electrical
outputs, and termination options to meet most pressure
sensing needs.
The P9000 Series incorporates 12 bit digital compensation
electronics to ensure precise calibration of all critical
parameters. This unique circuit design also provides a
significant advantage of maintaining a true analog “thru-
path” resulting in an exceptionally fast response of 1000
Hz without a sacrifice in accuracy. Error contribution
sources are digitally corrected to guarantee repeatable
performance and eliminate the need for user calibration.
Combined nonlinearity hysteresis and non-repeatability
errors are guaranteed to be less than ±0.08% F.R.O. with
total thermal error limited to 0.004% F.R.O/°C over an
extended industrial temperature range of -4°F to 185°F
(-20°C to 85°C).
The P9000 series delivers the advantages of a 17-4 PH
diaphragm offering a true stainless steel isolation barrier
with high burst pressures, at 20x the rated pressure, and a
proof pressure, up to 5x the rated pressure. Housed in a
rugged 316 stainless steel, NEMA 4X, IP67 enclosure with
guaranteed shock resistance of up to 1000g for 2msec, and
vibration to ±20g, the P9000 provides a robust solution for
a wide variety of demanding pressure applications and
environments.
Available in both cable and connector outlets, the P9000 is
offered in various electronic outputs: four wire 0-10 V,
four wire 0 to 5 V and a 2 wire 4-20 mA intrinsically safe
certified version. The P9000 can be configured to give 3
wire 1 to 6V or 1 to 11V output. All P9000 units are
constructed under an ISO 9001 environment. Each unit is
serialized and shipped with a calibration certificate
guaranteeing the highest quality and reliability found in an
instrument grade pressure transducer.
Digitally Compensated Pr essur e Transducer
P9000 Series
157
Common Specifications (all specifications are at 20°C unless otherwise noted)
Pressure Ranges
High psi.................. 0-75; 100; 150; 200; 250; 350; 500; 750; 1000; 1500; 2200; 2500; 3500; 5000; 7500; 10,000
bar................. 0-5; 7; 10; 15; 20; 25; 35; 50; 70; 100; 150; 200; 250; 350; 500; 700
Pressure References
High Pressure Range .... Vented gauge3: 0-75 to 0-350 psi
Absolute and sealed gauge: 0-75 to 0-10,000 psi
Pressure Limit ................... 5x full range scale pressure or 12,000 psi (830 bar), whichever is less
Burst Pressure................... 20 x rated pressure range or 22,000 psi (1500 bar), whichever is less
Pressure Media ................. Liquids or gases compatible with 17-4 PH and 17-7 PH stainless steel
Temperature Range
Operable ........................ -40°F to 212°F (-40°C to 100°C)
Compensated................. -4°F to 176°F (-20°C to 80°C)
Storage ........................... -40°F to 257°F (-40°C to 125°C)
Humidity
Connector Version........ 95% Relative Humidity
Cable Version ................ Immersible to IP67 (fluid must not enter ends of cables)
Vibration............................ Surpasses MIL STD 810C Method 514-2 Curve L
Shock ................................. 1000g for 2 msec will not damage sensor
Insulation Resistance ....... 500 Mohm at 50 VDC
Long Term Drift................ <0.1% F.R.O./year (<0.25% F.R.O. for first 6 months)
EMC ................................... CE Approved
The P9060, P9070 and P9080 Series when correctly installed comply with the EMC Directive
89/336/EEC Generic Standards for Residential Commercial, Light Industrial and Industrial
environments. Note: The Industrial environment cannot be complied with when the P9080
series is used in Intrinsic Safety applications where only one earth connection is made.
3Vented gauge units must only be used in dry, noncorrosive environments and will breathe through the cable vent tube
or hole in the 6-way receptacle.
Specifications by Model (All specifications are at 20°C unless otherwise noted)
Series P9060 P9070 P90801
Model Numbers P9061/4 P9071/4 P9081/4
Input Voltage 10 to 36 VDC 15 to 36 VDC 10 to 36 VDC
Current (mA) max < 6 < 6 N/A
Output (F.R.O.) 5 V ± 0.3% 10 V ± 0.3% 4-20 mA (16 mA ± 0.3%)
Impedance (ohms) <1 <1
Load Resistance (Ohms Min.) 1000 2000 1300 max at 36 V
Frequency Response 1 kHz 1 kHz 1 kHz
Combined Nonlinearity, Hysteresis and Nonrepeatability
High Range % F.R.O. (BSL) <±0.05 typ <±0.05 typ <±0.05 typ
<±0.08% max
Combined Thermal Zero & Sensitivity Error: (calculated from end points of temp. range)
The output will not deviate from 20°C by more then 0.5% F.R.O., over a temperature range of -20 to +80°C.
% F.R.O./°F <±0.002 <±0.002 <±0.002
% F.R.O./°C <±0.004 <±0.004 <±0.004
Residual Unbalance % F.R.O. <±0.3 <±0.3 <±0.3
Weight oz (gm) max (0001 version)
Connector Version 5.11 (145) 5.11 (145) 5.11 (145)
Cable Version 6.35 (180) 6.35 (180) 5.64 (160)
1Model P9080 is registered as an intrinsically safe transducer to Class ia IIc T4 BASEEFA, Cenelec EN50 - 020.
P9000 Series Foil Strain Gauge
Pressure Ranges: 0-75 to 0-10,000 psi
(0-5 to 0-700 bar)
Nonlinearity: <±0.08% F.R.O.
Select P9000 models, when correctly installed, are CE certified to
comply with the EMC Directive 89/336/EEC Generic Standards for
Residential, Commercial, Light Industrial and Industrial Environments.
158
Internet: www.schaevitz.com North America Tel: 800/745-8008
Fax Back System: 916/431-6541 Europe Tel: (01753) 537622
Dimensions in (mm)
P9000 Series
Advanced Digitally Compensated Pr essure Transducer
Connector Orientation
Connections
Cable Connector**
Red* Pin A* Excitation (+)
White Pin D Excitation (-)
Yellow Pin B Output (+)
Blue* Pin C* Output (-)
Violet Pin E No connection
Grey Pin F Factory use only
Note: Screen is connected to the case for CE marked units. Screen
is not connected to the case for optional IS units (P9080). IS
certification revokes CE certification.
* 2-wire connections (max cable length 50 meters when IS)
**Vented gauge units must breathe through the receptacle (mating
connector must have a vent hole)
Adapters Code Dimensions in (mm)
Thread Size Welded A B
G1/4A (BSP) (M) 0002 0.46 (11.7) 0.67 (16.9)
M14 x 1.5 (M) 0003 0.40 (10.2) 0.61 (15.4)
7/16"-20UNF-2A (M) 0004 0.56 (14.3) 0.77 (19.5)
1/4"-18NPT (M) 0005 0.55 (14.0) 0.76 (19.2)
M10 x 1.0 (F) 0006 0.60 (15.2)
Thread Size Screwed A B
G1/4A (BSP) (M) 0022 0.46 (11.7) 0.70 (17.8)
M14 x 1.5 (M) 0023 0.40 (10.2) 0.62 (15.8)
7/16"-20UNF-2A (M) 0024 0.56 (14.3) 0.78 (19.8)
1/4"-18NPT (M) 0025 0.55 (14.0) 0.80 (20.4)
M10 x 1.0 (M) 0026 0.60 (15.2)
Adaptor, Screwed
Adaptor, Welded
B
A
B
A
0.67
(17.0)
A/F
Bonded Seal
Connector
Orientation
A
D
C
B
E
F
A
D
C
B
E
F
A & SG.VG.
Connector Outlet
(P90X3-XXXX)
Thread G1/4B [BSP]
x 0.55 (14.0) Deep
0.756
(19.2)
A/F
Ø1.00
(25.4)
0.51
(13.0)
3.50 (89.0) 75-750 psi
3.562 (90.5) 751-10,000 psi
39.37
(1M)
Standard
(P90X1-XXXX)
159
P9000 Series Foil Strain Gauge
Pressure Ranges: 0-75 to 0-10,000 psi
(0-5 to 0-700 bar)
Nonlinearity: <±0.08% F.R.O.
How to Order
Specify by transducer excitation, electrical interface, pressure
port, pressure range, units, and pressure reference. Example:
P9061-0005-10 BA signifies a pressure transducer with 0 to 5
VDC output operating from 10-36V, cable outlet and 1/4
inch-18 NPT male pressure port, pressure range of 0 to 10
bar, with an absolute pressure reference.
Model Number Code P90 0
Input/Output
6 – 0 to 5 V output (10 to 32 V supply)
7– 0 to 10 V output (15 to 36 V supply)
8 – 4-20 mA output (10-36 V supply)
Cable/Connector
(Please reference to selected pressure range)
1 – High Range – cable outlet
3 – High Range – connector outlet
Unit
B: bar
P: psi
Pressure Reference
A: absolute
SG: sealed gauge
VG: vented gauge
Unit
0 – Welded Adapter
2 – Screw in Adapter
Pressure Range
(Enter full scale pressure range
without units)
High (psi) 0-75; 100; 150; 200; 250;
350; 500; 750; 1000;
1500; 2200; 2500; 3500;
5000; 7500; 10,000
(bar) 0-5; 7; 10; 15; 20; 25; 35;
50; 70; 100; 150; 200;
250; 350; 500; 700
Pressure Port
1 – 1/4 in BSP female
2 – 1/4 in BSP male
3 – M14 x 1.5 male
4 – 7/16 in 20 UNF 2A male
5 – 1/4 in 18 NPT male
6 – M10 x 1 female
Wiring
Corrosion resistant pressure transducers are
available with wetted parts manufactured from
Inconel 625 – consult factory for specifications.
B Yellow
C Blue
Output +Ve
Output
-
Ve
A Red
D White
E Violet
F Grey
Excitation +Ve
Excitation
-
Ve
Pin E – No connection
Pin F – Factory use only
C Blue
Output +Ve
Output
-
Ve
A Red
P9061/3 and 9071/3 P9081/3
Select P9000 models, when correctly installed, are CE certified to
comply with the EMC Directive 89/336/EEC Generic Standards for
Residential, Commercial, Light Industrial and Industrial Environments.
Intrinsic Safety
0 – Non IS
9 – IS (P9080 only)