MTC1 Series www.murata-ps.com Isolated 1W SM 2:1 Input Single Output DC-DC Converters Nom. V Rated Input Current Order Code Output Current 1 Output Voltage SELECTION GUIDE V mA mA Min. % Typ. % 12 12 12 24 24 24 3.3 5 12 3.3 5 12 303 200 83 303 200 83 110 110 100 55 55 55 72 77 77 73 74 75 75 78.5 79 75.5 76.5 77 Input Voltage MTC1S1203MC MTC1S1205MC MTC1S1212MC MTC1S2403MC MTC1S2405MC MTC1S2412MC FEATURES UL 60950 recognised for reinforced insulation ANSI/AAMI ES60601-1, 1 MOPP/ 2 MOOPs recognised 3kVAC isolation test voltage `Hi Pot Test' Continuous short circuit protection Output Voltage Trim Remote on/off pin No electrolytic capacitors Operating temperature range -40C to 100C 2:1 Input Range PRODUCT OVERVIEW The MTC1 series of miniature surface mount DCDC converters offers a single output voltage from input voltage ranges of 9-18V and 18-36V. The MTC1 series regulated output voltage is adjustable by 10% and a remote on/off pin is also included for application power saving. The MTC1 ideally suited to applications which include medical. Industrial, telecommunications, battery powered systems, and process automation. For full details go to www.murata-ps.com/rohs Efficiency Ripple and Noise Typ. Max. mVp/p mVp/p 25 25 20 30 25 25 50 50 40 55 50 50 MTTF2 MIL kHrs Telecordia kHrs 1143 1129 977 1042 990 833 17407 17407 17407 17109 17109 17109 INPUT CHARACTERISTICS Parameter Conditions Min. Typ. Max. 12V input types 9 12 18 24V input types 18 24 36 Units Voltage range Input reflected ripple current V All variants 2 mA p-p ISOLATION CHARACTERISTICS Parameter Isolation test voltage Isolation capacitance Resistance Conditions Min. Production tested for 1 second Qualification tested for 1 minute All variants Viso = 1kVDC 3000 3000 Typ. Max. Units VAC VAC pF G 7 1 OUTPUT CHARACTERISTICS Parameter Conditions Rated power All output types Min. Max. 1 Minimal load to meet datasheet specification Voltage set point accuracy Typ. 10 3V, 5V output types 12V output types Units W % -2.5 2 -3 2 % Line regulation Low line to high line 0.05 0.2 % Load regulation All output types 0.25 0.5 % Peak deviation (25-75% & 75-25% swing) Transient response 2403 variant 4 2405 variant 3 All other variants 2 1203 Settling time (within 5% Vout Nom.) %Vout 220 1205 260 1212, 2403 & 2405 100 2412 70 s 1. Components are supplied in tape and reel packaging, please refer to package specification section. Orderable part numbers are MTC1SXXXXMC-R7 (30 pieces per reel), or MTC1SXXXXMC-R13 (150 pieces per reel) 2. Calculated using MIL-HDBK-217 FN2 and Telecordia SR-332 calculation model with nominal input voltage at full load. All specifications typical at TA=25C, nominal input voltage and rated output current unless otherwise specified. www.murata-ps.com All enquiries: www.murata-ps.com/support KDC_MTC1.E01 Page 1 of 12 MTC1 Series Isolated 1W SM 2:1 Input Single Output DC-DC Converters GENERAL CHARACTERISTICS Parameter Switching frequency Remote on/off pin Conditions Min. 1203, 2405, 2403 variants 1205, 2412 variants 1212 variant Module on, pin unconnected or open collector floating Module off (refer to application notes) 12V input types 24V input types Typ. Max. 240 260 300 Units kHz 2 1.5 3.9 V mW TEMPERATURE CHARACTERISTICS Parameter Operation Storage Case temperature above ambient Conditions Min. Typ. -40 -50 100% Load, Nom VIN, Still Air Max. Units 100 125 C 15 ABSOLUTE MAXIMUM RATINGS Short-circuit protection (for SELV input voltages) Remote on/off pin input voltage Input voltage, MTC1 12V input types Input voltage, MTC1 24V input types www.murata-ps.com Continuous 6V 25V 40V All enquiries: www.murata-ps.com/support KDC_MTC1.E01 Page 2 of 12 MTC1 Series Isolated 1W SM 2:1 Input Single Output DC-DC Converters TECHNICAL NOTES ISOLATION VOLTAGE `Hi Pot Test', `Flash Tested', `Withstand Voltage', `Proof Voltage', `Dielectric Withstand Voltage' & `Isolation Test Voltage' are all terms that relate to the same thing, a test voltage, applied for a specified time, across a component designed to provide electrical isolation, to verify the integrity of that isolation. Murata Power Solutions MTC1 series of DC-DC converters are all 100% production tested at 3kVAC for 1 second and have been qualification tested at 3kVAC for 1 minute. A question commonly asked is, "What is the continuous voltage that can be applied across the part in normal operation?" The MTC1 series has been recognised by Underwriters Laboratory to 250 Vrms Reinforced Insulation, please see safety approval section below. REPEATED HIGH-VOLTAGE ISOLATION TESTING It is well known that repeated high-voltage isolation testing of a barrier component can actually degrade isolation capability, to a lesser or greater degree depending on materials, construction and environment. We therefore strongly advise against repeated high voltage isolation testing, but if it is absolutely required, that the voltage be reduced by 20% from specified test voltage. SAFETY APPROVAL ANSI/AAMI ES60601-1 The MTC1 series has been recognised by Underwriters Laboratory (UL) to ANSI/AAMI ES60601-1 and provides 1 MOPP (Means Of Patient Protection) and 2 MOOP (Means Of Operator Protection) based upon a working voltage of 250 Vrms max., between Primary and Secondary. File number E202895 applies. UL 60950 The MTC1 series has been recognised by Underwriters Laboratory (UL) to UL 60950 for reinforced insulation to a working voltage of 250 Vrms. File number E151252 applies. Creepage and clearance is 5mm. FUSING The MTC1 Series of converters are not internally fused so to meet the requirements of UL an anti-surge input line fuse should always be used with ratings as defined below. Input Voltage, 12V: 0.5A Input Voltage, 24V: 0.25A All fuses should be UL recognised and rated to 125V. RoHS COMPLIANCE INFORMATION, MSL This series is compatible with RoHS soldering systems with a peak reflow solder temperature of 245C as per J-STD-020D.1. The pin termination finish on this product series is Gold with Nickel Pre-plate. The series is backward compatible with Sn/Pb soldering systems. The series has a Moisture Sensitivity Level (MSL) 1. www.murata-ps.com All enquiries: www.murata-ps.com/support KDC_MTC1.E01 Page 3 of 12 MTC1 Series Isolated 1W SM 2:1 Input Single Output DC-DC Converters CHARACTERISATION TEST METHODS Ripple & Noise Characterisation Method Ripple and noise measurements are performed with the following test configuration. C1 1F X7R multilayer ceramic capacitor, voltage rating to be a minimum of 3 times the output voltage of the DC-DC converter 10F tantalum capacitor, voltage rating to be a minimum of 1.5 times the output voltage of the DC-DC converter with an ESR of less C2 than 100m at 100 kHz C3 100nF multilayer ceramic capacitor, general purpose R1 450 resistor, carbon film, 1% tolerance R2 50 BNC termination T1 3T of the coax cable through a ferrite toroid RLOAD Resistive load to the maximum power rating of the DC-DC converter. Connections should be made via twisted wires Measured values are multiplied by 10 to obtain the specified values. Differential Mode Noise Test Schematic DC/DC Converter OSCILLOSCOPE C1 C2 C3 + SUPPLY Input - + R1 T1 R2 Y INPUT Output - R LOAD APPLICATION NOTES Maximum Output Capacitance Maximum output capacitance should not exceed: Output Voltage V 3.3 5 12 Maximum Load Capacitance F 470 470 220 Start-up times Typical start up times for this series, with a typical input voltage rise time of 2.2s and output capacitance of 10F, are shown in the table below. The product series will start into the maximum output capacitance with increased start times. Typical Wave Form: Part No. MTC1S1203MC MTC1S1205MC MTC1S1212MC MTC1S2403MC MTC1S2405MC MTC1S2412MC www.murata-ps.com Start-up times ms 5 14 25 9 14 25 All enquiries: www.murata-ps.com/support KDC_MTC1.E01 Page 4 of 12 MTC1 Series Isolated 1W SM 2:1 Input Single Output DC-DC Converters APPLICATION NOTES (Continued) Control Pin The MTC1 converters have a shutdown feature which enables the user to disable the converter into a low power state. The control pin connects to the base of an internal NPN transistor with the converter shut down when the transistor is turned on by an external applied voltage. The converter can also be shut down using a 5V TTL signal (the unit is OFF for logic High and ON for logic LOW). If the control pin is left open (high impedance), the converter will run normally. A suitable application circuit is shown below. MTC1S VIN R2 VC or TTL -VIN R1 D1 CTRL Q1 D1 (e.g. 1N4001) is necessary for correct operation of the MTC1 when the control signal is LOW. The recommended drive current IB to shut down the MTC1 is 6mA to 15mA. The value of R1 can be derived as follows: R1 = VC - VD - 0.6 IB For a switch input: Calculate the value of R1 from the above equation given switch voltage Vc and chosen current between 6 and 15mA. For 5V TTL Signal: Set R1 to be between 320 to 800. Output Voltage Adjustment The MTC1S series has a trim capability which is located at pin 3, this allows the user to independently adjust the output voltages by 10%. Adjustments to the output voltages can be accomplished via a single fixed resistor as shown in Figures 1 and 2. A single fixed resistor can increase or decrease the output voltage depending on its connection. Fixed resistors should have low temperature coefficient to minimize sensitivity to changes in temperature. A single resistor connected from the TRIM pin (pin 3) to the +Vout (pin 4), will decrease the output voltage which is shown in figure 1. A single resistor connected from the TRIM pin (pin 3) to the -Vout (pin 2) will increase the output voltage which is shown in figure 2. TRIM DOWN TRIM UP Figure 1. Trim connections to decrease the output voltage 1 +Vin -Vout 2 TRIM 3 Figure 2. Trim connections to increase the output voltage 1 -Vout +Vin 2 RTRIM 6 -Vin 5 CTRL 3.3VoutRTRIM = 5VoutRTRIM = 12VoutRTRIM = RTRIM +Vout 18.64k x Vout - 52.3k 3.32 - Vout 33.2k x Vout - 141k 5 - Vout 21.5k x Vout - 171.29k 11.979 - Vout 4 6 -Vin 5 CTRL 3.3VoutRTRIM = 5VoutRTRIM = 12VoutRTRIM = TRIM 3 +Vout 4 14k x Vout - 52.3k 3.32 - Vout 23.2k x Vout - 141k 5 - Vout 12.4k x Vout - 171.29k 11.979 - Vout Accuracy of adjustment is subject to tolerances of resistors and factory adjusted output accuracy. Vout is equal to the desired output voltage. www.murata-ps.com All enquiries: www.murata-ps.com/support KDC_MTC1.E01 Page 5 of 12 MTC1 Series Isolated 1W SM 2:1 Input Single Output DC-DC Converters EFFICIENCY VS LOAD MTC1S1205MC 90 90 80 80 70 70 60 60 50 9 Vin 12 Vin 40 Efficiency (%) Efficiency (%) MTC1S1203MC 50 9 Vin 12 Vin 40 18 Vin 18 Vin 30 30 20 20 10 10 0 0 0 20 40 60 80 0 100 20 40 80 100 MTC1S2403MC 90 90 80 80 70 70 60 60 50 9 Vin 12 Vin 40 18 Vin Efficiency (%) Efficiency (%) MTC1S1212MC 50 18 Vin 24 Vin 40 36 Vin 30 30 20 20 10 10 0 0 0 20 40 60 80 0 100 20 40 60 80 100 Load (%) Load (%) MTC1S2405MC MTC1S2412MC 90 90 80 80 70 70 60 60 50 18 Vin 24 Vin 40 36 Vin Efficiency (%) Efficiency (%) 60 Load (%) Load (%) 50 18 Vin 36 Vin 30 30 20 20 10 10 0 24 Vin 40 0 0 20 40 60 Load (%) www.murata-ps.com 80 100 0 20 40 60 80 100 Load (%) All enquiries: www.murata-ps.com/support KDC_MTC1.E01 Page 6 of 12 MTC1 Series Isolated 1W SM 2:1 Input Single Output DC-DC Converters TEMPERATURE DERATING MTC1S1205MC- 12Vin 120 120 100 100 80 80 No Airflow 60 100lfm Load, % Load, % MTC1S1203MC - 12Vin 200lfm 40 No Airflow 60 100lfm 200lfm 40 400lfm 400lfm 20 20 0 0 70 75 80 85 90 95 70 100 75 80 MTC1S1212MC- 12Vin 90 95 100 MTC1S2403MC- 24Vin 120 100 100 80 80 No Airflow 60 100lfm Load, % 120 Load, % 85 Temperature, C Temperature, C 200lfm 40 No Airflow 60 100lfm 200lfm 40 400lfm 400lfm 20 20 0 0 70 75 80 85 90 95 70 100 75 80 MTC1S2405MC- 24Vin 90 95 100 MTC1S2412MC- 24Vin 120 120 100 100 80 80 No Airflow 60 100lfm 200lfm 40 Load, % Load, % 85 Temperature, C Temperature, C No Airflow 60 100lfm 200lfm 40 400lfm 20 400lfm 20 0 0 70 75 80 85 Temperature, C www.murata-ps.com 90 95 100 70 75 80 85 90 95 100 Temperature, C All enquiries: www.murata-ps.com/support KDC_MTC1.E01 Page 7 of 12 MTC1 Series Isolated 1W SM 2:1 Input Single Output DC-DC Converters TEMPERATURE DERATING MTC1S1203MC - 9Vin MTC1S1205MC- 9Vin 120 120 100 100 80 No Airflow 60 100lfm 200lfm 40 Load, % Load, % 80 No Airflow 60 100lfm 200lfm 40 400lfm 400lfm 20 20 0 70 75 80 85 90 95 0 100 70 75 80 Temperature, C MTC1S1212MC- 9Vin 90 95 100 MTC1S2403MC- 18Vin 120 120 100 100 80 80 No Airflow 60 100lfm Load, % Load, % 85 Temperature, C 200lfm 40 No Airflow 60 100lfm 200lfm 40 400lfm 400lfm 20 20 0 0 70 75 80 85 90 95 70 100 75 80 MTC1S2405MC- 18Vin 90 95 100 MTC1S2412MC- 18Vin 120 120 100 100 80 80 No Airflow 60 100lfm 200lfm 40 Load, % Load, % 85 Temperature, C Temperature, C No Airflow 60 100lfm 200lfm 40 400lfm 400lfm 20 20 0 0 70 75 80 85 Temperature, C www.murata-ps.com 90 95 100 70 75 80 85 90 95 100 Temperature, C All enquiries: www.murata-ps.com/support KDC_MTC1.E01 Page 8 of 12 MTC1 Series Isolated 1W SM 2:1 Input Single Output DC-DC Converters TEMPERATURE DERATING MTC1S1203MC - 18Vin MTC1S1205MC- 18Vin 100 100 80 80 No Airflow 60 100lfm Load, % 120 Load, % 120 200lfm 40 No Airflow 60 100lfm 200lfm 40 400lfm 400lfm 20 20 0 0 70 75 80 85 90 95 70 100 75 80 MTC1S1212MC- 18Vin 90 95 100 MTC1S2403MC- 36Vin 120 120 100 100 80 80 No Airflow 60 100lfm Load, % Load, % 85 Temperature, C Temperature, C 200lfm 40 No Airflow 60 100lfm 200lfm 40 400lfm 400lfm 20 20 0 0 70 75 80 85 90 95 70 100 75 80 MTC1S2405MC- 36Vin 90 95 100 MTC1S2412MC- 36Vin 120 120 100 100 80 80 No Airflow 60 100lfm 200lfm 40 Load, % Load, % 85 Temperature, C Temperature, C No Airflow 60 100lfm 200lfm 40 400lfm 400lfm 20 20 0 0 70 75 80 85 Temperature, C www.murata-ps.com 90 95 100 70 75 80 85 90 95 100 Temperature, C All enquiries: www.murata-ps.com/support KDC_MTC1.E01 Page 9 of 12 MTC1 Series Isolated 1W SM 2:1 Input Single Output DC-DC Converters EMC FILTERING AND SPECTRA FILTERING The module includes a basic level of filtering. With the addition of an input capacitor of 680nF and input inductor 10H that are typically required to meet EN 55022 Curve A Quasi-Peak EMC limit, as shown in the following plots. MTC1S1205MC 80 80 70 70 60 60 50 50 dBuV dBuV MTC1S1203MC 40 40 30 30 20 20 10 10 0 1.00E+05 1.00E+06 1.00E+07 0 1.00E+05 1.00E+08 Frequency (Hz) 80 70 70 60 60 50 dBuV dBuV 50 40 30 40 30 20 20 10 10 1.00E+06 1.00E+07 0 1.00E+05 1.00E+08 Frequency (Hz) 1.00E+06 1.00E+07 1.00E+08 Frequency (Hz) MTC1S2405MC MTC1S2412MC 80 80 70 70 60 60 50 50 dBuV dBuV 1.00E+08 MTC1S2403MC 80 40 30 40 30 20 20 10 0 1.00E+05 1.00E+07 Frequency (Hz) MTC1S1212MC 0 1.00E+05 1.00E+06 10 1.00E+06 1.00E+07 Frequency (Hz) www.murata-ps.com 1.00E+08 0 1.00E+05 1.00E+06 1.00E+07 1.00E+08 Frequency (Hz) All enquiries: www.murata-ps.com/support KDC_MTC1.E01 Page 10 of 12 MTC1 Series Isolated 1W SM 2:1 Input Single Output DC-DC Converters PACKAGE SPECIFICATIONS Mechanical Dimensions Pin Connections MTC1SXXXXMC XYYWW 14.99 [0.590] 14.22 [0.560] Pin Function 1 2 3 4 5 6 +Vin -Vout Trim +Vout Ctrl -Vin S 0.890.23 [0.030.01] 9.910.27 [0.390.011] 14.220.27 [0.560.011] 12.190.27 [0.480.011] 11.230.47 [0.4420.019] x6 PINS 0.10 S SEATING PLANE 1.140.24 [0.0450.009] 12.700.28 [0.5000.011] 1 2 7.620.27 [0.3000.011] 0.250.27 [0.0100.011] 3 12.450.25 [0.4900.010] 6 5 x6 PINS 1.020.05 [0.0400.002] 0.250.27 [0.0100.011] 4 x6 PINS 1.520.08 [0.0600.003] All dimensions in mm(inches), Controlling dimension is mm. Tolerances (unless otherwise stated) 0.10(0.004). Weight: 3.4g Components shown for reference only Recommended Footprint Details x6 PLACES 1.37 [0.054] x6 PLACES 1.91 [0.075] 0.25 [0.010] 9.91 [0.390] 12.19 [0.480] RECOMMENDED ISOLATION BARRIER 0.25 [0.010] 1.52 [0.060] 12.45 [0.490] 7.62 [0.300] 1.52 [0.060] 12.70 [0.500] www.murata-ps.com All enquiries: www.murata-ps.com/support KDC_MTC1.E01 Page 11 of 12 MTC1 Series Isolated 1W SM 2:1 Input Single Output DC-DC Converters TAPE & REEL SPECIFICATIONS REEL OUTLINE DIMENSIONS REEL PACKAGING DETAILS O330 [13.000] MAX OR O177.8 [7.000] MAX [ 13.5 5.319 O12.8 O 5.043 ] GOODS ENCLOSURE SECTION LEADER SECTION 400 [15.748] MIN 38.4 [1.512] MAX # TRAILER SECTION 160 [6.299] MIN 100 [3.937] MIN 1.50 [0.059] MIN O20.20 [O0.795] MIN Carrier tape pockets shown are illustrative only - Refer to carrier tape diagram for actual pocket details. Tape & Reel specifications shall conform with current EIA-481 standard Unless otherwise stated all dimensions in mm(inches) Controlling dimension is mm # Measured at hub Reel Quantity: 7" - 30 or 13" - 150 TAPE OUTLINE DIMENSIONS 14.20.1[0.5590.004] 28.4 [1.118] 32.00.3[1.260.01] 1.75 [0.069] 4.0 [0.157] [ +0.004 +0.1 O1.5 -0.0 O0.059 -0.000 O2.0 [O0.079] MIN ] XXXX 3 MAX 2.0 [0.079] 15.50.15 [0.6100.006]# 0.20.05[0.0080.002] COVER TAPE 14.80.15 [0.5830.006]# 3 MAX 0.6 [0.024] MAX 12.2 [0.480] 4.5 3.5 Tape & Reel specifications shall conform with current EIA-481 standard Unless otherwise stated all dimensions in mm(inches) 0.1mm (0.004 Inches) Controlling dimension is mm Components shall be orientated within the carrier tape as indicated # Measured on a plane 0.3mm above the bottom pocket [ 0.177 0.138 ] 28.0 [1.102] DIRECTION OF UNREELING This product is subject to the following operating requirements and the Life and Safety Critical Application Sales Policy: Refer to: http://www.murata-ps.com/requirements/ Murata Power Solutions, Inc. makes no representation that the use of its products in the circuits described herein, or the use of other technical information contained herein, will not infringe upon existing or future patent rights. The descriptions contained herein do not imply the granting of licenses to make, use, or sell equipment constructed in accordance therewith. Specifications are subject to change without notice. (c) 2018 Murata Power Solutions, Inc. www.murata-ps.com/support All enquiries: www.murata-ps.com/support KDC_MTC1.E01 Page 12 of 12