Data Sheet TC Series M Case
Characteristics
Item Performance Test conditions (based on JIS C 5101−1 and JIS C 5101−3)
Operating Temperature −55
°C to
+125
°C
Maximum operating
temperature with no voltage
derating
+85
°C
Rated voltage (VDC)
Category voltage (VDC)
Surge voltage (VDC)
DC Leakage current Shall be satisfied the voltage on
" Standard list "
Capacitance tolerance
Measuring frequency : 100
±
10kHz
Measuring voltage : 0.5Vrms or less
Measuring circuit
: DC Equivalent series circuit
Tangent of loss angle
(Df, tan δ)
Impedance
Resistance to
Soldering heat
Temperature
cycle
Moisture
resistance
There should be no significant abnormality.
The indications should be clear.
Appearance
ΔC / C
Df (tan δ)
L.C.
Shall be satisfied the voltage on
" Standard list " Measuring frequency : 120
±
12Hz
Measuring voltage : 0.5Vrms +1.5.DC
Measuring circuit
: DC Equivalent series circuit
Shall be satisfied the voltage on
" Standard list "
at 85
°C
at 125
°C
at 85
°C
Voltage : Rated voltage for 5min
Shall be satisfied allowance range.
±
20% Measuring frequency : 120
±
12Hz
Measuring voltage : 0.5Vrms +1.5.DC
Measuring circuit
: DC Equivalent series circuit
Less than 200% of initial limit
Less than 200% of initial limit
Voltage reduction when temperature exceeds +
85°C
As per 4.9 JIS C 5101-1
As per 4.5.1 JIS C 5101-3
As per 4.7 JIS C 5101-1
As per 4.5.2 JIS C 5101-3
As per 4.8 JIS C 5101-1
As per 4.5.3 JIS C 5101-3
As per 4.10 JIS C 5101-1
As per 4.5.4 JIS C 5101-3
As per 4.14 JIS C 5101-1
As per 4.6 JIS C 5101-3
Dip in the solder bath
Solder temp : 260
±
5
°C
Duration
:
5
±
0.5s
Repetition
: 1
After the specimens, leave it at room temperature for
over 24h and then measure the sample.
As per 4.16 JIS C 5101-1
As per 4.10 JIS C 5101-3
As per 4.22 JIS C 5101-1
As per 4.12 JIS C 5101-3
There should be no significant abnormality.
The indications should be clear.
Appearance
ΔC / C
Df (tan δ)
L.C. Less than 200% of initial limit
After leaving the sample under such atmospheric
condition that the temperature and humidity are
60±2°C and 90 to 95% RH,respectiveiy, for 500±12h
leave it at room
temperature for over 24h and then measure the
sample.
Less than 200%
of initial limit
There should be no significant abnormality.
The indications should be clear.
Appearance
ΔC / C
Df (tan δ)
L.C. Less than 200% of initial limit
Repetition : 5 cycles
(1 cycle : steps 1 to 4) without discontinuation.
Less than 200% of initial limit
Temp. Time
1
2
3
4
Room temp.
Room temp.
3min.or less
3min.or less
30±3min.
30±3min.
−55 3°C
+
−
125 2°C
+
−
After the specimens, leave it at room temperature for
over 24h and then measure the sample.
Others : Within ±20% of initial value.
TCM0J336 : Within ±30% of initial value.
Others : Within ±20% of initial value.
TCM0J336 : Within ±30% of initial value.
Others : Within ±20% of initial value.
TCM0J336 : Within ±30% of initial value.