P/N 108964 rev. A 7
U-GAGE™ S18U Series Sensor — Discrete Output
Banner Engineering Corp. • Minneapolis, MN U.S.A.
www.bannerengineering.com • Tel: 763.544.3164
Sensing Range 30 to 300 mm (1.2" to 11.8")
Supply Voltage 10 to 30V dc (10% maximum ripple); 65 mA max. (exclusive of load), 40 mA typical @ 25V input
Ultrasonic Frequency 300 kHz, rep. rate 2.5 ms
Supply Protection Circuitry Protected against reverse polarity and transient voltages
Output Configuration SPST solid-state switch conducts when target is sensed within sensing window; one NPN (current sinking)
and one PNP (current sourcing) output in each model.
Output Protection Protected against short circuit conditions
Output Ratings 100 mA maximum
OFF-state leakage current: < 5 microamps
NPN saturation: < 200 mV @ 10 mA and < 600 mV @ 100 mA
PNP saturation: < 1.2V @ 10 mA and < 1.6V @ 100 mA
Output Response Time 5 milliseconds
Delay at Power-Up 300 milliseconds
Temperature Effect 0.02% of distance/ °C
Repeatability 0.5 mm
Minimum Window Size 5 mm
Hysteresis 0.7 mm
Adjustments Sensing window limits: TEACH-Mode programming of near and far window limits may be set using the
push button or remotely via TEACH input (see page 3).
Indicators Range Indicator (Red/Green) Green — Target is within sensing range
Red — Target is outside sensing range
OFF — Sensing power is OFF
Teach/Output Indicator (Yellow/Red) Yellow — Target is within taught limits
OFF — Target is outside taught window limits
Red — Sensor is in TEACH mode
Remote TEACH Input Impedance: 12 kΩ
Construction Threaded Barrel: Thermoplastic polyester Push Button Housing: ABS/PC
Push Button: Santoprene Lightpipes: Acrylic
Operating Conditions Temperature: -20° to +60° C (-4° to +140° F)
Maximum relative humidity: 100%
Connections 2 m (6.5') or 9 m (30') shielded 5-conductor (with drain) PVC jacketed attached cable or 5-pin
Euro-style quick-disconnect (see page 10 for quick-disconnect cable options)
Environmental Rating Leakproof design is rated IEC IP67; NEMA 6P
Vibration and Mechanical
Shock
All models meet Mil. Std. 202F requirements method 201A (vibration: 10 to 60Hz max., double amplitude
0.06", maximum acceleration 10G). Also meets IEC 947-5-2 requirements: 30G 11 ms duration, half sine
wave.
Temperature Warmup Drift Less than 1.7% of sensing distance upon power-up (see Temperature Compensation, page 2)
Application Notes Objects passing inside the specified near limit may produce a false response.
Certifications
Specifications