relays
0800 731 3186 www.oem.co.uk
130
MRC 14 PIN (FLAT BLADE) STANDARD/
POWER/LATCHING
•Lockable test button
•Marking label on relay
•2 window mechanical flag (not available on C4-X20)
•Colour coded test button
•Coil voltage marked on top of relay
•Label carries full technical information
•CE marked
C4-R30... Latching relay
Three change-over contacts, 10 A
10A/250V AC1 10 A @ 30V DC1
6A/250V AC15 0,5A @ 110V DC1
C4-X20... Power relay, DC
Double pole, NO, double make
10A / 250V AC1 1,2A @ 220V DC1
7A @ 110V DC1 0,3A @ 220V DC13
Contacts
Materials code 0 (standard)
Max. switching current 10 A
Peak inrush current (20 ms) 30 A
Max. switching voltage, (pollution 3) 250 V
Max. switching voltage, (pollution 2) 400 V
Max. AC load (Table 11) 2 KVA
Max. DC load See Table 10
Contacts
Materials code 0 (standard); options: 8 - 9
Max. switching current 10 A
Peak inrush current (20 ms) 30 A
Max. switching voltage, (pollution 3) 250 V
Max. switching voltage, (pollution 2) 400 V
Max. AC load (Table 11) 2 KVA
Max. DC load See Table 2, page 126
A2
14
811
(+)
13
A1
25
11
12 14
21
22 24 32 34
31
8
7
5
4
2
1
9
63
ON (+)
A1
13 12
OFF (+)
(-)
A2
14
A3
Standard types (50/60 Hz and DC)
AC 24, 48, 115 (110 ... 120), 230
X = LED (optional) C4-X20 X/ ... V
RC suppressor C4-X20R ... V
(LED not possible with RC suppressor)
DC 12, 24, 48, 110, 120/125, 220
X = LED (optional) C4-X20 X/ ... V
Free wheeling diode C4-X20D X/ ... V
Free wheeling and polarity C4-X20F X/ ... V
AC/DC rectifier (60V max.) C4-X20B X/ ... V
Standard types (50/60 Hz and DC)
AC 24, 48, 115 (110 ... 120), 230
C4-R30 /... V
DC 12, 24, 48, 110, 125
Two coils C4-R30 /... V
Note: All AC and DC coils withstand
permanent connection.
Specifications
Nominal coil power: 2,4 VA (AC), 1,3 W (DC)
Operate time 20 ms.
Release time 8 ms.
Isolation: EN60947 pollution 3, Gr C 250V
Dielectric strength, contacts/coil 2,5 KV
Dielectric strength, pole/pole 2,5 KV
Specifications
ON pulse power 1,5 VA/ W
OFF pulse power 0,5 VA/ W
Min. pulse length for ON/OFF control: 50 ms.
Isolation: EN60947 pollution 3, Gr C 250V
Dielectric strength, contacts/coil 2,5 KV
Dielectric strength, pole/pole 2,5 KV
gap > 3 mm (1,7+1,7)
C4-A40... General purpose
Four change-over contacts, 10 A
10A/250V AC1 10 A @ 30V DC1
6A/250V AC15 0,5A @ 110V DC1
Contacts
Materials code 0 (standard); options: 8 - 9
Max. switching current 10 A
Peak inrush current (20 ms) 30 A
Max. switching voltage, (pollution 3) 250 V
Max. switching voltage, (pollution 2) 400 V
Max. AC load (Table 11) 2 KVA
Max. DC load See Table 2, page 126
12
41
10 11
4442
11
12 14
21
22 24 32 34
31
8
7
5
4
2
1
9
63
13
A1(+)
A2
14
Standard types (50/60 Hz and DC)
AC 24, 48, 115 (110 ... 120), 230
X = LED (optional) C4-A40 X/ ... V
RC suppressor C4-A40R ... V
(LED not possible with RC suppressor)
DC 12, 24, 48, 110, 120/125, 220
X = LED (optional) C4-A40 X/ ... V
Free wheeling diode C4-A40D X/ ... V
Free wheeling and polarity C4-A40F X/ ... V
AC/DC rectifier (60V max.) C4-A40B X/ ... V
Specifications
Nominal coil power: 2,4 VA (AC), 1,4 W (DC)
Operate time 20 ms.
Release time 8 ms.
Isolation: EN60947 pollution 3, Gr C 250V
Dielectric strength, contacts/coil 2,5 KV
Dielectric strength, pole/pole 2,5 KV
35
1
25
4
8
7
11
10
9
12
14
6
3
13
8
8
8
4.15
6.75
6.75
7.0
6.5
3.85
ø1.5
FASTON .110
C.I.
1.2
35
3
52.5
DC1
DC13
AC15
AC1
10
1
0,1
Volts 25 75 125 175 225
Amps
10
1
0,1
KVA 0,25 0,5 1 1,5 2 2,5
ops
Table 10 Máx. DC load
Type C3-X10, C4-X20 Table 11 Electrical life (ops x 106)
Types C4-A40, C4-X20, C4-R30