LY
Refer to List of Certified Models for a list of models that are certified for safety standards and the Electrical Appliances
and Material Safety Act.
Characteristics
Endurance Under Real Loads (Reference Only)
Classification 1 pole Double-, 3-, and 4-pole models Bifurcated contacts
Item Load Resistive load Inductive load
(cos φ = 0.4, L/R = 7 ms) Resistive load Inductive load
(cos φ = 0.4, L/R = 7 ms) Resistive load Inductive load
(cos φ = 0.4, L/R = 7 ms)
Contact type Single Bifurcated
Contact materials Ag alloy Ag
Rated load
15 A at 110 VAC
15 A at 24 VDC
10 A at 110 VAC
7 A at 24 VDC
10 A at 110 VAC
10 A at 24 VDC
7.5 A at 110 VAC
5 A at 24 VDC
5 A at 110 VAC
5 A at 24 VDC
4 A at 110 VAC
4 A at 24 VDC
Rated carry current 15 A 10 A 7 A
Maximum contact voltage 250 VAC
125 VDC
250 VAC
125 VDC
250 VAC
125 VDC
Maximum contact current 15 A 15 A 10 A 10 A 7 A 7 A
Item
Type
Single-pole and double-pole models
(standard models and bifurcated contact
models)
Single-pole, double-pole models
(models with built-in operation indicators, models
with built-in diodes, and models with built-in CR
circuits),
3-pole and 4-pole models
Note: 1.
Some models in the LY1 and LY2 Series have an upper
temperature limit of +40°C. This limitation is due to the
diode junction temperature and the elements used.
2.
Refer to
Ambient Temperature vs. Coil Temperature
Rise
in
Engineering Data
on page 8 to 9 for information
on operation in temperature conditions that are not
described here.
3.
When you apply a minimum of 10 A of current to an LY1
when it is used in combination with the PTF-08-PU,
PTF-08-PU-L, PTF08A, PTF08A-E, or PT08, connect
each of the following terminal pairs: (1) to (2), (3) to (4),
and (5) to (6).
*1.
If the carry current is 4 A or less, the usable ambient temperature
range is
−
25 to 70° C.
*2.
If the flowing current is 4 A or less, the usable ambient
temperature range is -25 to 55° C.
Ambient operating
temperature
−25 to 55°C
(with no icing or condensation)*1
−25 to +40°C
(with no icing or condensation)*2
Ambient operating
humidity 5% to 85%
Item
Type
Standard models, models with built-in operation
indicators, models with built-in CR circuits, and
models with built-in diodes
Bifurcated contacts
Contact resistance
*
1
50 mΩ max. Note: The values at the left are initial values.
*1. Measurement conditions: 1 A at 5 VDC using the voltage
drop method
*2. Measurement conditions: With rated operating power
applied, not including contact bounce.
Ambient temperature condition: 23° C
*3. Measurement conditions: For 500 VDC applied to the
same location as for dielectric strength measurement.
*4. Ambient temperature condition: 23° C
*5. This value was measured at a switching frequency of 120
operations per minute.
Operating time
*
2
25 ms max.
Release time
*
2
25 ms max.
Maximum
operating
frequency
Mechanical 18,000 operations/h
Rated load 1,800 operations/h
Insulation resistance
*
3
100 MΩ min.
Dielectric
strength
Between coil and contacts
2,000 VAC at 50/60 Hz for 1 min.
Between contacts of
different polarity
Between contacts of
the same polarity 1,000 VAC at 50/60 Hz for 1 min.
Vibration
resistance
Destruction
10 to 55 to 10 Hz, 0.5-mm single amplitude (1.0-mm double amplitude)
Malfunction
10 to 55 to 10 Hz, 0.5-mm single amplitude (1.0-mm double amplitude)
Shock
resistance
Destruction 1,000 m/s2
Malfunction 200 m/s2
Endurance
Mechanical
AC: 50,000,000 operations min.
DC: 100,000,000 operations min.
(switching frequency: 18,000
operations/h)
Electrical
*
4
1-, 3-, 4-pole: 200,000 operations min.
2-pole: 500,000 operations min.
(rated load, operating frequency: 1,800
operations/h)
2-pole: 500,000 operations min.
(rated load, operating frequency: 1,800
operations/h)
Failure rate P value (reference value)
*
5
100 mA at 5 VDC 10mA at 5 VDC
Weight 1-pole and 2-pole: 40 g, 3-pole: Approx. 50 g, 4-pole: Approx. 70 g
Load
type
Item LY1, 100 VAC LY2, 100 VAC LY4, 100 VAC
Conditions Operating
frequency
Electrical life
(×10,000
operations min.)
Conditions Operating
frequency
Electrical life
(×10,000
operations min.)
Conditions Operating
frequency
Electrical life
(×10,000
operations min.)
AC motor
400 W, 100 VAC single-
phase with 35-A inrush
current, 7-A current
flow
ON for 10 s,
OFF for 50 s
5
200 W, 100 VAC single-
phase with 25-A inrush
current, 5-A current
flow
ON for 10 s,
OFF for 50 s 20
200 W, 200 VAC three-
phase with 5-A inrush
current, 1-A current
flow
ON for 10 s,
OFF for 50 s
50
750 W, 200 VAC three-
phase with 18-A inrush
current, 3.5-A current
flow
7
AC lamp
300 W, 100 VAC with
51-A inrush current, 3-
A current flow
ON for 5 s,
OFF for 55 s
10 300 W, 100 VAC with
51-A inrush current, 3-
A current flow
ON for 5 s,
OFF for 55 s 8
300 W, 100 VAC with
51-A inrush current, 3-
A current flow
ON for 5 s,
OFF for 55 s
5
500 W, 100 VAC with
78-A inrush current, 5-
A current flow
2.5
Capacitor
(2,000 µF)
24 VDC with 50-A
inrush current, 1-A
current flow
ON for 1 s,
OFF for 6 s
10
24 VDC with 50-A
inrush current, 1-A
current flow ON for 1 s,
OFF for 15 s
1
24 VDC with 50-A
inrush current, 1-A
current flow
ON for 1 s,
OFF for 15 s
0.5
24 VDC with 20-A
inrush current, 1-A
current flow
15
24 VDC with 20-A
inrush current, 1-A
current flow
ON for 1 s,
OFF for 2 s
20
AC solenoid
50 VA with 2.5-A inrush
current, 0.25-A current
flow
ON for 1 s,
OFF for 2 s
150
50 VA with 2.5-A inrush
current, 0.25-A current
flow ON for 1 s,
OFF for 2 s
100
50 VA with 2.5-A inrush
current, 0.25-A current
flow
ON for 1 s,
OFF for 2 s
100
100 VA with 5-A inrush
current, 0.5-A current
flow
80
100 VA with 5-A inrush
current, 0.5-A current
flow
50
100 VA with 5-A inrush
current, 0.5-A current
flow
50