ADC081C021, ADC081C027
www.ti.com
SNAS447C FEBRUARY 2008REVISED MARCH 2013
ADC081C021/ADC081C027 I
2
C-Compatible, 8-Bit Analog-to-Digital Converter with Alert
Function
Check for Samples: ADC081C021,ADC081C027
1FEATURES DESCRIPTION
The ADC081C021 is a low-power, monolithic, 8-bit,
23 I2C-Compatible 2-Wire Interface Which analog-to-digital converter (ADC) that operates from a
Supports Standard (100kHz), Fast (400kHz), +2.7 to 5.5V supply. The converter is based on a
and High Speed (3.4MHz) Modes successive approximation register architecture with
Extended Power Supply Range (+2.7V to an internal track-and-hold circuit that can handle input
+5.5V) frequencies up to 11MHz. The ADC081C021
operates from a single supply which also serves as
Up to Nine Pin-Selectable Chip Addresses the reference. The device features an I2C-compatible
(VSSOP-8 only) serial interface that operates in all three speed
Out-of-Range Alert Function modes, including high speed mode (3.4MHz).
Automatic Power-Down Mode While Not The ADC's Alert feature provides an interrupt that is
Converting activated when the analog input violates a
Very Small SOT-6 and VSSOP-8 Packages programmable upper or lower limit value. The device
features an automatic conversion mode, which frees
±8kV HBM ESD Protection (SDA, SCL) up the controller and I2C interface. In this mode, the
ADC continuously monitors the analog input for an
APPLICATIONS "out-of-range" condition and provides an interrupt if
System Monitoring the measured voltage goes out-of-range.
Peak Detection The ADC081C021 comes in two packages: a small
Portable Instruments SOT-6 package with an alert output, and an VSSOP-
8 package with an alert output and two address
Medical Instruments selection inputs. The ADC081C027 comes in a small
Test Equipment SOT-6 package with an address selection input. The
ADC081C027 provides three pin-selectable
KEY SPECIFICATIONS addresses while the VSSOP-8 version of the
ADC081C021 provides nine pin-selectable
Resolution: 8 bits; No Missing Codes addresses. Pin-compatible alternatives to the SOT-6
Conversion Time 1 µs (Typ) options are available with additional address options.
INL & DNL: ±0.2 LSB (Max) Normal power consumption using a +3V or +5V
Throughput Rate: 188.9 ksps (Max) supply is 0.26mW or 0.78mW, respectively. The
Power Consumption (at 22ksps): automatic power-down feature reduces the power
consumption to less than 1µW while not converting.
3V Supply: 0.26 mW (Typ) Operation over the industrial temperature range of
5V Supply: 0.78 mW (Typ) 40°C to +105°C is ensured. Their low power
consumption and small packages make this family of
ADCs an excellent choice for use in battery operated
equipment.
The ADC081C021 and ADC081C027 are part of a
family of pin-compatible ADCs that also provide 10-
and 12-bit resolution. For 10-bit ADCs see the
ADC101C021 and ADC101C027. For 12-bit ADCs
see the ADC121C021 and ADC121C027.
1Please be aware that an important notice concerning availability, standard warranty, and use in critical applications of
Texas Instruments semiconductor products and disclaimers thereto appears at the end of this data sheet.
2I2C is a registered trademark of Phillips Corporation..
3All other trademarks are the property of their respective owners.
PRODUCTION DATA information is current as of publication date. Copyright © 2008–2013, Texas Instruments Incorporated
Products conform to specifications per the terms of the Texas
Instruments standard warranty. Production processing does not
necessarily include testing of all parameters.
ALERT
SCL
SDA
VIN
VA
GND SOT
1
2
3
5
4
6
ADC081C021
ADDR
SCL
SDA
VIN
VA
GND SOT
1
2
3
5
4
6
ADC081C027
ALERT
SDA
ADR1
VA
GND
VSSOP
1
2
4
7
8
3
SCL
6
5
VIN
ADC081C021
ADR0
ADC081C021, ADC081C027
SNAS447C FEBRUARY 2008REVISED MARCH 2013
www.ti.com
Table 1. Pin-Compatible AlternativesAll devices are fully pin and function compatible.
Resolution SOT-6 (Alert only) and VSSOP-8 SOT-6 (Addr only)
12-bit ADC121C021 ADC121C027
10-bit ADC101C021 ADC101C027
8-bit ADC081C021 ADC081C027
Connection Diagrams
Figure 1. SOT (Alert Only) See Figure 2. SOT (Addr Only) See Figure 3. VSSOP See Package
Package Number DDC Package Number DDC Number DGK
2Submit Documentation Feedback Copyright © 2008–2013, Texas Instruments Incorporated
Product Folder Links: ADC081C021 ADC081C027
SDA
SCL
Lowest Conversion
Configuration
I2C Serial Interface
ADC081C021/
ADC081C027
Conversion Result
High Limit
Low Limit
Pointer
Register
and
Decode
Logic
Alert
Set-Point
Comparator
ADDR*
Highest Conversion
8-Bit
Successive
Approximation
ADC
GND
VA
Hysteresis
VIN
Alert Status
ALERT*
T/H
Oscillator
REF
* Note: The ADC081C021 has the ALERT pin but no ADDR pin.
The ADC081C027 has the ADDR pin but no ALERT pin.
ADC081C021, ADC081C027
www.ti.com
SNAS447C FEBRUARY 2008REVISED MARCH 2013
Block Diagram
PIN DESCRIPTIONS
Symbol Type Equivalent Circuit Description
Power and unbufferred reference voltage. VAmust be free
VASupply of noise and decoupled to GND.
GND Ground Ground for all on-chip circuitry.
VIN Analog Input See Figure 22 Analog input. This signal can range from GND to VA.
Copyright © 2008–2013, Texas Instruments Incorporated Submit Documentation Feedback 3
Product Folder Links: ADC081C021 ADC081C027
Snap
Back
GND
D1
PIN
V+
2.1k 41.5k
41.5k
Snap
Back
GND
D1
PIN
ADC081C021, ADC081C027
SNAS447C FEBRUARY 2008REVISED MARCH 2013
www.ti.com
PIN DESCRIPTIONS (continued)
Symbol Type Equivalent Circuit Description
Alert output. Can be configured as active high or active low.
ALERT Digital Output This is an open drain data line that must be pulled to the
supply (VA) with an external pull-up resistor.
Serial Clock Input. SCL is used together with SDA to control
the transfer of data in and out of the device. This is an open
drain data line that must be pulled to the supply (VA) with an
SCL Digital Input external pull-up resistor. This pin's extended ESD tolerance(
8kV HBM) allows extension of the I2C bus across multiple
boards without extra ESD protection.
Serial Data bi-directional connection. Data is clocked into or
out of the internal 16-bit register with SCL. This is an open
Digital drain data line that must be pulled to the supply (VA) with an
SDA Input/Output external pull-up resistor. This pin's extended ESD tolerance(
8kV HBM) allows extension of the I2C bus across multiple
boards without extra ESD protection.
Tri-level Address Selection Input. Sets Bits A0 & A1 of the
ADDR0 7-bit slave address. (see Table 2)
Digital Input,
three levels Tri-level Address Selection Input. Sets Bits A2 & A3 of the
ADDR1 7-bit slave address. (see Table 2)
Package Pinouts
VAGND VIN ALERT SCL SDA ADR0 ADR1
ADC081C021 (SOT-6) 1 2 3 4 5 6 N/A N/A
ADC081C027 (SOT-6) 1 2 3 N/A 5 6 4 N/A
ADC081C021 (VSSOP-8) 57421836
These devices have limited built-in ESD protection. The leads should be shorted together or the device placed in conductive foam
during storage or handling to prevent electrostatic damage to the MOS gates.
4Submit Documentation Feedback Copyright © 2008–2013, Texas Instruments Incorporated
Product Folder Links: ADC081C021 ADC081C027
I/O
GND
TO INTERNAL
CIRCUITRY
ADC081C021, ADC081C027
www.ti.com
SNAS447C FEBRUARY 2008REVISED MARCH 2013
Absolute Maximum Ratings(1)(2)(3)
Supply Voltage, VA(4) -0.3V to +6.5V
Voltage on any Analog Input Pin to GND 0.3V to (VA+0.3V)
Voltage on any Digital Input Pin to GND 0.3V to 6.5V
Input Current at Any Pin(5) ±15 mA
Package Input Current(5) ±20 mA
Power Dissipation at TA= 25°C See(6)
Human Body Model 2500V
VA, GND, VIN, ALERT, ADR pins Machine Model 250V
ESD Susceptibility(7) Charged Device Model (CDM) 1250V
Human Body Model 8000V
SDA, SCL pins Machine Model 400V
Junction Temperature +150°C
Storage Temperature 65°C to +150°C
(1) Absolute Maximum Ratings indicate limits beyond which damage to the device may occur. Operating Ratings indicate conditions for
which the device is functional, but do not ensure specific performance limits. For ensured specifications and test conditions, see the
Electrical Characteristics. The ensured specifications apply only for the test conditions listed. Some performance characteristics may
degrade when the device is not operated under the listed test conditions. Operation of the device beyond the maximum Operating
Ratings is not recommended.
(2) All voltages are measured with respect to GND = 0V, unless otherwise specified.
(3) If Military/Aerospace specified devices are required, please contact the Texas Instruments Sales Office/Distributors for availability and
specifications.
(4) To ensure accuracy, it is required that VAbe well bypassed and free of noise.
(5) When the input voltage at any pin exceeds 5.5V or is less than GND, the current at that pin should be limited per the Absolute Maximum
Ratings. The maximum package input current rating limits the number of pins that can safely exceed the power supplies.
(6) The absolute maximum junction temperature (TJmax) for this device is 150°C. The maximum allowable power dissipation is dictated by
TJmax, the junction-to-ambient thermal resistance (θJA), and the ambient temperature (TA), and can be calculated using the formula
PDMAX = (TJmax TA) / θJA. The values for maximum power dissipation will be reached only when the device is operated in a severe
fault condition (e.g., when input or output pins are driven beyond the operating ratings, or the power supply polarity is reversed).
(7) Human body model is a 100 pF capacitor discharged through a 1.5 kresistor. Machine model is a 220 pF capacitor discharged
through 0 . Charged device model simulates a pin slowly acquiring charge (such as from a device sliding down the feeder in an
automated assembler) then rapidly being discharged.
Operating Ratings(1)(2)
Operating Temperature Range 40°C TA+105°C
Supply Voltage, VA+2.7V to 5.5V
Analog Input Voltage, VIN 0V to VA
Digital Input Voltage(3) 0V to 5.5V
Sample Rate up to 188.9 ksps
(1) Absolute Maximum Ratings indicate limits beyond which damage to the device may occur. Operating Ratings indicate conditions for
which the device is functional, but do not ensure specific performance limits. For ensured specifications and test conditions, see the
Electrical Characteristics. The ensured specifications apply only for the test conditions listed. Some performance characteristics may
degrade when the device is not operated under the listed test conditions. Operation of the device beyond the maximum Operating
Ratings is not recommended.
(2) All voltages are measured with respect to GND = 0V, unless otherwise specified.
(3) The inputs are protected as shown below. Input voltage magnitudes up to 5.5V, regardless of VA, will not cause errors in the conversion
result. For example, if VAis 3V, the digital input pins can be driven with a 5V logic device.
Copyright © 2008–2013, Texas Instruments Incorporated Submit Documentation Feedback 5
Product Folder Links: ADC081C021 ADC081C027
ADC081C021, ADC081C027
SNAS447C FEBRUARY 2008REVISED MARCH 2013
www.ti.com
Package Thermal Resistances(1)(2)
Package θJA
6-Lead SOT 250°C/W
8-Lead VSSOP 200°C/W
(1) Soldering process must comply with Reflow Temperature Profile specifications. Refer to www.ti.com/packaging.
(2) Reflow temperature profiles are different for lead-free packages.
Electrical Characteristics
The following specifications apply for VA= +2.7V to +5.5V, GND = 0V, fSCL up to 3.4MHz, fIN = 1kHz for fSCL up to 400kHz, fIN
= 10kHz for fSCL = 3.4MHz unless otherwise noted. Boldface limits apply for TA= TMIN to TMAX: all other limits TA= 25°C
unless otherwise noted.
Symbol Parameter Conditions Typical(1) Limits(1) Units (Limits)
STATIC CONVERTER CHARACTERISTICS
Resolution with No Missing Codes 8Bits
VA= +2.7V to +3.6V ±0.04 ±0.2 LSB (max)
Integral Non-Linearity (End Point
INL Method) VA= +2.7V to +5.5V. fSCL up to 400kHz(2) ±0.1 ±0.25 LSB (max)
VA= +2.7V to +3.6V +0.04 ±0.2 LSB (max)
DNL Differential Non-Linearity VA= +2.7V to +5.5V. fSCL up to 400kHz(2) ±0.08 ±0.25 LSB (max)
VA= +2.7V to +3.6V +0.26 ±0.5 LSB (max)
VOFF Offset Error VA= +2.7V to +5.5V. fSCL up to 400kHz(2) +0.25 ±0.5 LSB (max)
GE Gain Error -0.01 ±0.4 LSB (max)
DYNAMIC CONVERTER CHARACTERISTICS
ENOB Effective Number of Bits 7.98 7.8 Bits (min)
SNR Signal-to-Noise Ratio 49.8 49 dB (min)
THD Total Harmonic Distortion 70.6 64 dB (max)
SINAD Signal-to-Noise Plus Distortion Ratio 49.8 49 dB (min)
SFDR Spurious-Free Dynamic Range -68.8 65 dB (min)
Intermodulation Distortion, Second
IMD VA= +3.0V, fa= 1.035 kHz, fb= 1.135 kHz 75.5 dB
Order Terms (IMD2)
Intermodulation Distortion, Third VA= +3.0V, fa= 1.035 kHz, fb= 1.135 kHz 71.8 dB
Order Terms (IMD3)VA= +3.0V 8 MHz
FPBW Full Power Bandwidth (3dB) VA= +5.0V 11 MHz
ANALOG INPUT CHARACTERISTICS
VIN Input Range 0 to VAV
IDCL DC Leakage Current(3) ±1 µA (max)
Track Mode 30 pF
CINA Input Capacitance Hold Mode 3 pF
SERIAL INTERFACE INPUT CHARACTERISTICS (SCL, SDA)
VIH Input High Voltage 0.7 x VAV (min)
VIL Input Low Voltage 0.3 x VAV (max)
IIN Input Current(3) ±1 µA (max)
CIN Input Pin Capacitance 3 pF
VHYST Input Hysteresis 0.1 x VAV (min)
ADDRESS SELECTION INPUT CHARACTERISTICS (ADDR)
VIH Input High Voltage VA- 0.5V V (min)
VIL Input Low Voltage 0.5 V (max)
(1) Typical figures are at TJ= 25°C, and represent most likely parametric norms. Test limits are specified to AOQL (Average Outgoing
Quality Level).
(2) The ADC will meet Minimum/Maximum specifications for fSCL up to 3.4MHz and VA= 2.7V to 3.6V when operating in the QUIET
INTERFACE MODE.
(3) This parameter is specified by design and/or characterization and is not tested in production.
6Submit Documentation Feedback Copyright © 2008–2013, Texas Instruments Incorporated
Product Folder Links: ADC081C021 ADC081C027
ADC081C021, ADC081C027
www.ti.com
SNAS447C FEBRUARY 2008REVISED MARCH 2013
Electrical Characteristics (continued)
The following specifications apply for VA= +2.7V to +5.5V, GND = 0V, fSCL up to 3.4MHz, fIN = 1kHz for fSCL up to 400kHz, fIN
= 10kHz for fSCL = 3.4MHz unless otherwise noted. Boldface limits apply for TA= TMIN to TMAX: all other limits TA= 25°C
unless otherwise noted.
Symbol Parameter Conditions Typical(1) Limits(1) Units (Limits)
IIN Input Current(3) ±1 µA (max)
LOGIC OUTPUT CHARACTERISTICS, OPEN-DRAIN (SDA, ALERT)
ISINK = 3 mA 0.4 V (max)
VOL Output Low Voltage ISINK = 6 mA 0.6 V (max)
High-Impedence Output Leakage
IOZ ±1 µA (max)
Current(3)
Output Coding Straight (Natural) Binary
POWER REQUIREMENTS
Supply Voltage Minimum 2.7 V (min)
VASupply Voltage Maximum 5.5 V (max)
Continuous Operation Mode -- 2-wire interface active. VA= 2.7V to 3.6V 0.08 0.14 mA (max)
fSCL=400kHz VA= 4.5V to 5.5V 0.16 0.30 mA (max)
INSupply Current VA= 2.7V to 3.6V 0.37 0.55 mA (max)
fSCL=3.4MHz VA= 4.5V to 5.5V 0.74 0.99 mA (max)
VA= 3.0V 0.26 mW
fSCL=400kHz VA= 5.0V 0.78 mW
PNPower Consumption VA= 3.0V 1.22 mW
fSCL=3.4MHz VA= 5.0V 3.67 mW
Automatic Conversion Mode -- 2-wire interface stopped and quiet (SCL = SDA = VA). fSAMPLE = TCONVERT * 32
VA= 2.7V to 3.6V 0.41 0.59 mA (max)
IASupply Current VA= 4.5V to 5.5V 0.78 1.2 mA (max)
VA= 3.0V 1.35 mW
PAPower Consumption VA= 5.0V 3.91 mW
Power Down Mode (PD1) -- 2-wire interface stopped and quiet. (SCL = SDA = VA).(4)
IPD1 Supply Current 0.1 0.2 µA (max)
PPD1 Power Consumption 0.5 0.9 µW (max)
Power Down Mode (PD2) -- 2-wire interface active. Master communicating with a different device on the bus.
VA= 2.7V to 3.6V 13 45 µA (max)
fSCL=400kHz VA= 4.5V to 5.5V 27 80 µA (max)
IPD2 Supply Current VA= 2.7V to 3.6V 89 150 µA (max)
fSCL=3.4MHz VA= 4.5V to 5.5V 168 250 µA (max)
VA= 3.0V 0.04 mW
fSCL=400kHz VA= 5.0V 0.14 mW
PPD2 Power Consumption VA= 3.0V 0.29 mW
fSCL=3.4MHz VA= 5.0V 0.84 mW
(4) This parameter is specified by design and/or characterization and is not tested in production.
Copyright © 2008–2013, Texas Instruments Incorporated Submit Documentation Feedback 7
Product Folder Links: ADC081C021 ADC081C027
ADC081C021, ADC081C027
SNAS447C FEBRUARY 2008REVISED MARCH 2013
www.ti.com
A.C. and Timing Characteristics
The following specifications apply for VA= +2.7V to +5.5V. Boldface limits apply for TMIN TATMAX and all other limits are
at TA= 25°C, unless otherwise specified. Units
Symbol Parameter Conditions(1) Typical(2) Limits(1)(2) (Limits)
CONVERSION RATE
Conversion Time 1 µs
fSCL = 100kHz 5.56 ksps
fSCL = 400kHz 22.2 ksps
fCONV Conversion Rate fSCL = 1.7MHz 94.4 ksps
fSCL = 3.4MHz 188.9 ksps
DIGITAL TIMING SPECS (SCL, SDA)
Standard Mode 100 kHz (max)
Fast Mode 400 kHz (max)
fSCL Serial Clock Frequency High Speed Mode, Cb= 100pF 3.4 MHz (max)
High Speed Mode, Cb= 400pF 1.7 MHz (max)
Standard Mode 4.7 us (min)
Fast Mode 1.3 us (min)
tLOW SCL Low Time High Speed Mode, Cb= 100pF 160 ns (min)
High Speed Mode, Cb= 400pF 320 ns (min)
Standard Mode 4.0 us (min)
Fast Mode 0.6 us (min)
tHIGH SCL High Time High Speed Mode, Cb= 100pF 60 ns (min)
High Speed Mode, Cb= 400pF 120 ns (min)
Standard Mode 250 ns (min)
tSU;DAT Data Setup Time Fast Mode 100 ns (min)
High Speed Mode 10 ns (min)
0us (min)
Standard Mode(3) 3.45 us (max)
0us (min)
Fast Mode(3) 0.9 us (max)
tHD;DAT Data Hold Time 0ns (min)
High Speed Mode, Cb= 100pF 70 ns (max)
0ns (min)
High Speed Mode, Cb= 400pF 150 ns (max)
Standard Mode 4.7 us (min)
Setup time for a start or a repeated
tSU;STA Fast Mode 0.6 us (min)
start condition High Speed Mode 160 ns (min)
Standard Mode 4.0 us (min)
Hold time for a start or a repeated start
tHD;STA Fast Mode 0.6 us (min)
condition High Speed Mode 160 ns (min)
Bus free time between a stop and start Standard Mode 4.7 us (min)
tBUF condition Fast Mode 1.3 us (min)
Standard Mode 4.0 us (min)
tSU;STO Setup time for a stop condition Fast Mode 0.6 us (min)
High Speed Mode 160 ns (min)
Standard Mode 1000 ns (max)
20+0.1Cbns (min)
Fast Mode 300 ns (max)
trDA Rise time of SDA signal 10 ns (min)
High Speed Mode, Cb= 100pF 80 ns (max)
20 ns (min)
High Speed Mode, Cb= 400pF 160 ns (max)
(1) Cbrefers to the capacitance of one bus line. Cbis expressed in pF units.
(2) Typical figures are at TJ= 25°C, and represent most likely parametric norms. Test limits are specified to AOQL (Average Outgoing
Quality Level).
(3) The ADC081C021 will provide a minimum data hold time of 300ns to comply with the I2C Specification.
8Submit Documentation Feedback Copyright © 2008–2013, Texas Instruments Incorporated
Product Folder Links: ADC081C021 ADC081C027
SCL
SDA
tHD;STA
tLOW
tr
tHD;DAT tHIGH
tf
tSU;DAT
tSU;STA tSU;STO
tf
START REPEATED
START STOP
tHD;STA
START
tSP
trtBUF
ADC081C021, ADC081C027
www.ti.com
SNAS447C FEBRUARY 2008REVISED MARCH 2013
A.C. and Timing Characteristics (continued)
The following specifications apply for VA= +2.7V to +5.5V. Boldface limits apply for TMIN TATMAX and all other limits are
at TA= 25°C, unless otherwise specified. Units
Symbol Parameter Conditions(1) Typical(2) Limits(1)(2) (Limits)
Standard Mode 250 ns (max)
20+0.1Cbns (min)
Fast Mode 250 ns (max)
tfDA Fall time of SDA signal 10 ns (min)
High Speed Mode, Cb= 100pF 80 ns (max)
20 ns (min)
High Speed Mode, Cb= 400pF 160 ns (max)
Standard Mode 1000 ns (max)
20+0.1Cbns (min)
Fast Mode 300 ns (max)
trCL Rise time of SCL signal 10 ns (min)
High Speed Mode, Cb= 100pF 40 ns (max)
20 ns (min)
High Speed Mode, Cb= 400pF 80 ns (max)
Standard Mode 1000 ns (max)
20+0.1Cbns (min)
Fast Mode 300 ns (max)
Rise time of SCL signal after a
trCL1 repeated start condition and after an 10 ns (min)
High Speed Mode, Cb= 100pF
acknowledge bit. 80 ns (max)
20 ns (min)
High Speed Mode, Cb= 400pF 160 ns (max)
Standard Mode 300 ns (max)
20+0.1Cbns (min)
Fast Mode 300 ns (max)
tfCL Fall time of a SCL signal 10 ns (min)
High Speed Mode, Cb= 100pF 40 ns (max)
20 ns (min)
High Speed Mode, Cb= 400pF 80 ns (max)
Capacitive load for each bus line (SCL
Cb400 pF (max)
and SDA) Fast Mode 50 ns (max)
tSP Pulse Width of spike suppressed(4) High Speed Mode 10 ns (max)
(4) Spike suppression filtering on SCL and SDA will suppress spikes that are less than 50ns for standard and fast modes, and less than
10ns for hs-mode.
Timing Diagrams
Figure 4. Serial Timing Diagram
Copyright © 2008–2013, Texas Instruments Incorporated Submit Documentation Feedback 9
Product Folder Links: ADC081C021 ADC081C027
ADC081C021, ADC081C027
SNAS447C FEBRUARY 2008REVISED MARCH 2013
www.ti.com
Specification Definitions
ACQUISITION TIME is the time required for the ADC to acquire the input voltage. During this time, the hold
capacitor is charged by the input voltage.
APERTURE DELAY is the time between the start of a conversion and the time when the input signal is internally
acquired or held for conversion.
CONVERSION TIME is the time required, after the input voltage is acquired, for the ADC to convert the input
voltage to a digital word.
DIFFERENTIAL NON-LINEARITY (DNL) is the measure of the maximum deviation from the ideal step size of 1
LSB.
EFFECTIVE NUMBER OF BITS (ENOB, or EFFECTIVE BITS) is another method of specifying Signal-to-Noise
and Distortion or SINAD. ENOB is defined as (SINAD - 1.76) / 6.02 and says that the converter is equivalent to a
perfect ADC of this (ENOB) number of bits.
FULL POWER BANDWIDTH is a measure of the frequency at which the reconstructed output fundamental
drops 3 dB below its low frequency value for a full scale input.
GAIN ERROR is the deviation of the last code transition (111...110) to (111...111) from the ideal (VREF - 1.5
LSB), after adjusting for offset error.
INTEGRAL NON-LINEARITY (INL) is a measure of the deviation of each individual code from a line drawn from
negative full scale LSB below the first code transition) through positive full scale LSB above the last code
transition). The deviation of any given code from this straight line is measured from the center of that code value.
INTERMODULATION DISTORTION (IMD) is the creation of additional spectral components as a result of two
sinusoidal frequencies being applied to an individual ADC input at the same time. It is defined as the ratio of the
power in both the second and third order intermodulation products to the power in one of the original frequencies.
Second order products are fa± fb, where faand fbare the two sine wave input frequencies. Third order products
are (2fa± fb) and (fa± 2fb). IMD is usually expressed in dB.
MISSING CODES are those output codes that will never appear at the ADC output. The ADC081C021 is
ensured not to have any missing codes.
OFFSET ERROR is the deviation of the first code transition (000...000) to (000...001) from the ideal (i.e. GND +
0.5 LSB).
SIGNAL TO NOISE RATIO (SNR) is the ratio, expressed in dB, of the rms value of the input signal to the rms
value of the sum of all other spectral components below one-half the sampling frequency, not including
harmonics or d.c.
SIGNAL TO NOISE PLUS DISTORTION (S/N+D or SINAD) Is the ratio, expressed in dB, of the rms value of the
input signal to the rms value of all of the other spectral components below half the clock frequency, including
harmonics but excluding d.c.
SPURIOUS FREE DYNAMIC RANGE (SFDR) is the difference, expressed in dB, between the desired signal
amplitude to the amplitude of the peak spurious spectral component, where a spurious spectral component is
any signal present in the output spectrum that is not present at the input and may or may not be a harmonic.
TOTAL HARMONIC DISTORTION (THD) is the ratio, expressed in dBc, of the rms total of the first n harmonic
components at the output to the rms level of the input signal frequency as seen at the output. THD is calculated
as
(1)
where Af1 is the RMS power of the input frequency at the output and Af2 through Afn are the RMS power in the
first n harmonic frequencies.
THROUGHPUT TIME is the minimum time required between the start of two successive conversions. It is the
acquisition time plus the conversion time.
LEAST SIGNIFICANT BIT (LSB) is the bit that has the smallest value or weight of all bits in a word. This value is
LSB = VA/ 2n(2)
10 Submit Documentation Feedback Copyright © 2008–2013, Texas Instruments Incorporated
Product Folder Links: ADC081C021 ADC081C027
ADC081C021, ADC081C027
www.ti.com
SNAS447C FEBRUARY 2008REVISED MARCH 2013
where VAis the supply voltage for this product, and "n" is the resolution in bits, which is 8 for the ADC081C021.
MOST SIGNIFICANT BIT (MSB) is the bit that has the largest value or weight of all bits in a word. Its value is
1/2 of VA.
Copyright © 2008–2013, Texas Instruments Incorporated Submit Documentation Feedback 11
Product Folder Links: ADC081C021 ADC081C027
ADC081C021, ADC081C027
SNAS447C FEBRUARY 2008REVISED MARCH 2013
www.ti.com
Typical Performance Characteristics
fSCL = 400kHz, fSAMPLE = 22ksps, fIN = 1kHz, VA= 5.0V, TA= +25°C, unless otherwise stated.
INL vs. Code - VA=3V DNL vs. Code - VA=3V
Figure 5. Figure 6.
INL vs. Code - VA=5V DNL vs. Code - VA=5V
Figure 7. Figure 8.
INL vs. Supply DNL vs. Supply
Figure 9. Figure 10.
12 Submit Documentation Feedback Copyright © 2008–2013, Texas Instruments Incorporated
Product Folder Links: ADC081C021 ADC081C027
ADC081C021, ADC081C027
www.ti.com
SNAS447C FEBRUARY 2008REVISED MARCH 2013
Typical Performance Characteristics (continued)
fSCL = 400kHz, fSAMPLE = 22ksps, fIN = 1kHz, VA= 5.0V, TA= +25°C, unless otherwise stated.
ENOB vs. Supply SINAD vs. Supply
Figure 11. Figure 12.
FFT Plot - VA=3V FFT Plot - VA=3V
Figure 13. Figure 14.
Offset Error vs. Temperature Gain Error vs. Temperature
Figure 15. Figure 16.
Copyright © 2008–2013, Texas Instruments Incorporated Submit Documentation Feedback 13
Product Folder Links: ADC081C021 ADC081C027
ADC081C021, ADC081C027
SNAS447C FEBRUARY 2008REVISED MARCH 2013
www.ti.com
Typical Performance Characteristics (continued)
fSCL = 400kHz, fSAMPLE = 22ksps, fIN = 1kHz, VA= 5.0V, TA= +25°C, unless otherwise stated.
Continuous Operation Supply Current vs. VAAutomatic Conversion Supply Current vs. VA
Figure 17. Figure 18.
Power Down (PD1) Supply Current vs. VA
Figure 19.
14 Submit Documentation Feedback Copyright © 2008–2013, Texas Instruments Incorporated
Product Folder Links: ADC081C021 ADC081C027
VIN
AGND
SAMPLING
CAPACITOR
SW1 -
+CONTROL
LOGIC
SW2
VA/2
CHARGE
REDISTRIBUTION
DAC
VIN
AGND
SAMPLING
CAPACITOR
SW1 -
+CONTROL
LOGIC
SW2
VA/2
CHARGE
REDISTRIBUTION
DAC
ADC081C021, ADC081C027
www.ti.com
SNAS447C FEBRUARY 2008REVISED MARCH 2013
Functional Description
The ADC081C021 and the ADC081C027 are successive-approximation analog-to-digital converters designed
around a charge-redistribution digital-to-analog converter. Unless otherwise stated, references to the
ADC081C021 in this section will apply to both the ADC081C021 and the ADC081C027.
CONVERTER OPERATION
Simplified schematics of the ADC081C021 in both track and hold operation are shown in Figure 20 and
Figure 21 respectively. In Figure 20, the ADC081C021 is in track mode. SW1 connects the sampling capacitor to
the analog input channel and SW2 equalizes the comparator inputs. The ADC is in this state for approximately
0.4µs at the beginning of every conversion cycle, which begins at the ACK fall of SDA. Conversions occur when
the conversion result register is read and when the ADC is in automatic conversion mode. (see AUTOMATIC
CONVERSION MODE).
Figure 21 shows the ADC081C021 in hold mode. SW1 connects the sampling capacitor to ground and SW2
unbalances the comparator. The control logic then instructs the charge-redistribution DAC to add or subtract
fixed amounts of charge to or from the sampling capacitor until the comparator is balanced. When the
comparator is balanced, the digital word supplied to the DAC is also the digital representation of the analog input
voltage. This digital word is stored in the conversion result register and read via the 2-wire interface.
In the Normal (non-Automatic) Conversion mode, a new conversion is started after the previous conversion result
is read. In the Automatic Mode, conversions are started at set intervals, as determined by bits D7 through D5 of
the Configuration Register. The intent of the Automatic mode is to provide a "watchdog" function to ensure that
the input voltage remains within the limits set in the Alert Limit Registers. The minimum and maximum
conversion results can then be read from the Lowest Conversion Register and the Highest Conversion Register,
as described in INTERNAL REGISTERS.
Figure 20. ADC081C021 in Track Mode Figure 21. ADC081C021 in Hold Mode
ANALOG INPUT
An equivalent circuit for the input of the ADC081C021 is shown in Figure 22. The diodes provide ESD protection
for the analog input. The operating range for the analog input is 0 V to VA. Going beyond this range will cause
the ESD diodes to conduct and result in erratic operation. For this reason, these diodes should NOT be used to
clamp the input signal.
The capacitor C1 in Figure 22 has a typical value of 3 pF and is mainly the package pin capacitance. Resistor R1
is the on resistance (RON) of the multiplexer and track / hold switch and is typically 500. Capacitor C2 is the
ADC081C021 sampling capacitor, and is typically 30 pF. The ADC081C021 will deliver best performance when
driven by a low-impedance source (less than 100). This is especially important when using the ADC081C021 to
sample dynamic signals. A buffer amplifier may be necessary to limit source impedance. Use a precision op-amp
to maximize circuit performance. Also important when sampling dynamic signals is a band-pass or low-pass filter
to reduce noise at the input.
Copyright © 2008–2013, Texas Instruments Incorporated Submit Documentation Feedback 15
Product Folder Links: ADC081C021 ADC081C027
|
|
|
0V +VA - 1.5 LSB
0.5 LSB ANALOG INPUT
1 LSB = VA/256
ADC CODE
111...111
111...110
111...000
011...111
000...010
000...001
000...000
VIN
D1
R1
C2
30 pF
VA
D2
C1
3 pF
Conversion Phase - Switch Open
Track Phase - Switch Closed
ADC081C021, ADC081C027
SNAS447C FEBRUARY 2008REVISED MARCH 2013
www.ti.com
Figure 22. Equivalent Input Circuit
The analog input is sampled for eight internal clock cycles, or for typically 400 ns, after the fall of SDA for
acknowledgement. This time could be as long as about 530 ns. The sampling switch opens and the conversion
begins this time after the fall of ACK. This time are typical at room temperature and may vary with temperature.
ADC TRANSFER FUNCTION
The output format of the ADC081C021 is straight binary. Code transitions occur midway between successive
integer LSB values. The LSB width for the ADC081C021 is VA/ 256. The ideal transfer characteristic is shown in
Figure 23. The transition from an output code of 0000 0000 0000 to a code of 0000 0000 0001 is at 1/2 LSB, or a
voltage of VA/ 512. Other code transitions occur at intervals of 1 LSB.
Figure 23. Ideal Transfer Characteristic
REFERENCE VOLTAGE
The ADC081C021 uses the supply (VA) as the reference, so VAmust be treated as a reference. The analog-to-
digital conversion will only be as precise as the reference (VA), so the supply voltage should be free of noise. The
reference should be driven by a low output impedance voltage source.
The Applications section provides recommended ways to provide the supply voltage appropriately. Refer to
TYPICAL APPLICATION CIRCUIT for details.
16 Submit Documentation Feedback Copyright © 2008–2013, Texas Instruments Incorporated
Product Folder Links: ADC081C021 ADC081C027
SDA
SCL
I2C Serial Interface
Conversion Result
Pointer = 00000000
Pointer
Register
(selects
register to
read from
or write to)
Pointer Address
Highest Conversion
Pointer = 00000111
Lowest Conversion
Pointer = 00000110
Configuration
Pointer = 00000010
Alert Status
Pointer = 00000001
Hysteresis
Pointer = 00000101
High Limit
Pointer = 00000100
Low Limit
Pointer = 00000011
Data
ADC081C021, ADC081C027
www.ti.com
SNAS447C FEBRUARY 2008REVISED MARCH 2013
POWER-ON RESET
An internal power-on reset (POR) occurs when the supply voltage transitions above the power-on reset
threshold. Each of the registers contains a defined value upon POR and this data remains there until any of the
following occurs:
The first conversion is completed, causing the Conversion Result and Status registers to be updated.
A different data word is written to a writeable register.
The ADC is powered down.
The internal registers will lose their contents if the supply voltage goes below 2.4V. Should this happen, it is
important that the VAsupply be lowered to a maximum of 200mV before the supply is raised again to properly
reset the device and ensure that the ADC performs as specified.
INTERNAL REGISTERS
The ADC081C021 has 8 internal data registers and one address pointer. The registers provide additional ADC
functions such as storing minimum and maximum conversion results, setting alert threshold levels, and storing
data to configure the operation of the device. Figure 24 shows all of the registers and their corresponding
address pointer values. All of the registers are read/write capable except the conversion result register which is
read-only.
Figure 24. Register Structure
Copyright © 2008–2013, Texas Instruments Incorporated Submit Documentation Feedback 17
Product Folder Links: ADC081C021 ADC081C027
ADC081C021, ADC081C027
SNAS447C FEBRUARY 2008REVISED MARCH 2013
www.ti.com
Address Pointer Register
The address pointer determines which of the data registers is accessed by the I2C interface. The first data byte
of every write operation is stored in the address pointer register. This value selects the register that the following
data bytes will be written to or read from. Only the three LSBs of this register are variable. The other bits must
always be written to as zeros. After a power-on reset, the pointer register defaults to all zeros (conversion result
register).
Default Value: 00h
P7 P6 P5 P4 P3 P2 P1 P0
0 0 0 0 0 Register Select
P2 P1 P0 REGISTER
0 0 0 Conversion Result (read only)
0 0 1 Alert Status (read/write)
0 1 0 Configuration (read/write)
0 1 1 Low Limit (read/write)
1 0 0 High Limit (read/write)
1 0 1 Hysteresis (read/write)
1 1 0 Lowest Conversion (read/write)
1 1 1 Highest Conversion (read/write)
Conversion Result Register
This register holds the result of the most recent conversion. In the normal mode, a new conversion is started
whenever this register is read. The conversion result data is in straight binary format with the MSB at D11.
Pointer Address 00h (Read Only)
Default Value: 0000h
D15 D14 D13 D12 D11 D10 D9 D8
Alert Flag Reserved Conversion Result [7:4]
D7 D6 D5 D4 D3 D2 D1 D0
Conversion Result [3:0] Reserved
Bits Name Description
15 Alert Flag This bit indicates when an alert condition has occurred. When the Alert Bit Enable is set in the
Configuration Register, this bit will be high if either alert flag is set in the Alert Status Register.
Otherwise, this bit is a zero. The I2C controller will typically read the Alert Status register and other data
registers to determine the source of the alert.
14:12 Reserved Always reads zeros.
11:4 Conversion Result The Analog-to-Digital conversion result. The Conversion result data is a 8-bit data word in straight
binary format. The MSB is D11.
3:0 Reserved Always reads zeros.
18 Submit Documentation Feedback Copyright © 2008–2013, Texas Instruments Incorporated
Product Folder Links: ADC081C021 ADC081C027
ADC081C021, ADC081C027
www.ti.com
SNAS447C FEBRUARY 2008REVISED MARCH 2013
Alert Status Register
This register indicates if a high or a low threshold has been violated. The bits of this register are active high. That
is, a high indicates that the respective limit has been violated.
Pointer Address 01h (Read/Write)
Default Value: 00h
D7 D6 D5 D4 D3 D2 D1 D0
Reserved Over Range Under Range
Alert Alert
Bits Name Description
7:2 Reserved Always reads zeros. Zeros must be written to these bits.
1 Over Range Bit is set to 1 when the measured voltage exceeds the VHIGH limit stored in the programmable VHIGH
Alert Flag limit register. Flag is reset to 0 when one of the following two conditions is met: (1) The controller writes
a one to this bit. (2) The measured voltage decreases below the programmed VHIGH limit minus the
programmed VHYST value (See Figure 27) . The alert will only self-clear if the Alert Hold bit is cleared in
the Configuration register. If the Alert Hold bit is set, the only way to clear an over range alert is to write
a one to this bit.
0 Under Range Bit is set to 1 when the measured voltage falls below the VLOW limit stored in the programmable VLOW
Alert Flag limit register. Flag is reset to 0 when one of the following two conditions is met: (1) The controller writes
a one to this bit. (2) The measured voltage increases above the programmed VLOW limit plus the
programmed VHYST value. The alert will only self-clear if the Alert Hold bit is cleared in the
Configuration register. If the Alert Hold bit is set, the only way to clear an under range alert is to write a
one to this bit.
Configuration Register
Pointer Address 02h (Read/Write)
Default Value: 00h
D7 D6 D5 D4 D3 D2 D1 D0
Cycle Time [2:0] Alert Hold Alert Flag Enable Alert Pin Enable 0 Polarity
Cycle Time[2:0] Conversion Typical fconvert
Interval (ksps)
D7 D6 D5
0 0 0 Mode Disabled 0
0 0 1 Tconvert x 32 27
0 1 0 Tconvert x 64 13.5
0 1 1 Tconvert x 128 6.7
1 0 0 Tconvert x 256 3.4
1 0 1 Tconvert x 512 1.7
1 1 0 Tconvert x 1024 0.9
1 1 1 Tconvert x 2048 0.4
Copyright © 2008–2013, Texas Instruments Incorporated Submit Documentation Feedback 19
Product Folder Links: ADC081C021 ADC081C027
ADC081C021, ADC081C027
SNAS447C FEBRUARY 2008REVISED MARCH 2013
www.ti.com
Bits Name Description
7:5 Cycle Time Configures Automatic Conversion mode. When these bits are set to zeros, the automatic conversion
mode is disabled. This is the case at power-up.
When these bits are set to a non-zero value, the ADC will begin operating in automatic conversion
mode. (See AUTOMATIC CONVERSION MODE). The Cycle Time table shows how different values
provide various conversion intervals.
4 Alert Hold 0: Alerts will self-clear when the measured voltage moves within the limits by more than the hysteresis
register value.
1: Alerts will not self-clear and are only cleared when a one is written to the alert high flag or the alert
low flag in the Alert Status register.
3 Alert Flag Enable 0: Disables alert status bit [D15] in the Conversion Result register.
1: Enables alert status bit [D15] in the Conversion Result register.
2 Alert Pin Enable 0: Disables the ALERT output pin. The ALERT output will TRI-STATE when the pin is disabled.
1: Enables the ALERT output pin.
*This bit does not apply to the ADC081C027.
1 Reserved Always reads zeros. Zeros must be written to these bits.
0 Polarity This bit configures the active level polarity of the ALERT output pin.
0: Sets the ALERT pin to active low.
1: Sets the ALERT pin to active high.
*This bit does not apply to the ADC081C027.
VLOW -- Alert Limit Register - Under Range
This register holds the lower limit threshold used to determine the alert condition. If the conversion moves lower
than this limit, a VLOW alert is generated.
Pointer Address 03h (Read/Write)
Default Value: 0000h
D15 D14 D13 D12 D11 D10 D9 D8
Reserved VLOW Limit [7:4]
D7 D6 D5 D4 D3 D2 D1 D0
VLOW Limit [3:0] Reserved
Bits Name Description
15:12 Reserved Always reads zeros. Zeros must be written to these bits.
11:4 VLOW Limit Sets the lower limit threshold used to determine the alert condition. If the conversion moves lower than
this limit, a VLOW alert is generated.
3:0 Reserved Always reads zeros. Zeros must be written to these bits.
VHIGH -- Alert Limit Register - Over Range
This register holds the upper limit threshold used to determine the alert condition. If the conversion moves higher
than this limit, a VHIGH alert is generated.
Pointer Address 04h (Read/Write)
Default Value: 0FFFh
D15 D14 D13 D12 D11 D10 D9 D8
Reserved VHIGH Limit [7:4]
D7 D6 D5 D4 D3 D2 D1 D0
VHIGH Limit [3:0] Reserved
20 Submit Documentation Feedback Copyright © 2008–2013, Texas Instruments Incorporated
Product Folder Links: ADC081C021 ADC081C027
ADC081C021, ADC081C027
www.ti.com
SNAS447C FEBRUARY 2008REVISED MARCH 2013
Bits Name Description
15:12 Reserved Always reads zeros. Zeros must be written to these bits.
11:4 VHIGH Limit Sets the upper limit threshold used to determine the alert condition. If the conversion moves higher
than this limit, a VHIGH alert is generated.
3:0 Reserved Always reads zeros. Zeros must be written to these bits.
VHYST -- Alert Hysteresis Register
This register holds the hysteresis value used to determine the alert condition. After a VHIGH or VLOW alert occurs,
the conversion result must move within the VHIGH or VLOW limit by more than this value to clear the alert
condition. Note: If the Alert Hold bit is set in the configuration register, alert conditions will not self-clear.
Pointer Address 05h (Read/Write)
Default Value: 0000h
D15 D14 D13 D12 D11 D10 D9 D8
Reserved Hysteresis [7:4]
D7 D6 D5 D4 D3 D2 D1 D0
Hysteresis [3:0] Reserved
Bits Name Description
15:12 Reserved Always reads zeros. Zeros must be written to these bits.
11:4 Hysteresis Hysteresis value. D11 is MSB.
3:0 Reserved Always reads zeros. Zeros must be written to these bits.
VMIN -- Lowest Conversion Register
This register holds the Lowest Conversion result when in the automatic conversion mode. Each conversion result
is compared against the contents of this register. If the value is lower, it becomes the lowest conversion and
replaces the current value. If the value is higher, the register contents remain unchanged. The lowest conversion
value can be cleared at any time by writing 0FFFh to this register. The value of this register will update
automatically when the automatic conversion mode is enabled, but is NOT updated in the normal mode.
Pointer Address 06h (Read/Write)
Default Value: 0FFFh
D15 D14 D13 D12 D11 D10 D9 D8
Reserved Lowest Conversion [7:4]
D7 D6 D5 D4 D3 D2 D1 D0
Lowest Conversion [3:0] Reserved
Bits Name Description
15:12 Reserved Always reads zeros. Zeros must be written to these bits.
11:4 Lowest Conversion Lowest conversion result data. D11 is MSB.
3:0 Reserved Always reads zeros. Zeros must be written to these bits.
Copyright © 2008–2013, Texas Instruments Incorporated Submit Documentation Feedback 21
Product Folder Links: ADC081C021 ADC081C027
ADC081C021, ADC081C027
SNAS447C FEBRUARY 2008REVISED MARCH 2013
www.ti.com
VMAX -- Highest Conversion Register
This register holds the Highest Conversion result when in the Automatic mode. Each conversion result is
compared against the contents of this register. If the value is higher, it replaces the previous value. If the value is
lower, the register contents remain unchanged. The highest conversion value can be cleared at any time by
writing 0000h to this register. The value of this register will update automatically when the automatic conversion
mode is enabled, but is NOT updated in the normal mode.
Pointer Address 07h (Read/Write)
Default Value: 0000h
D15 D14 D13 D12 D11 D10 D9 D8
Reserved Highest Conversion [7:4]
D7 D6 D5 D4 D3 D2 D1 D0
Highest Conversion [3:0] Reserved
Bits Name Description
15:12 Reserved Always reads zeros. Zeros must be written to these bits.
11:4 Highest Conversion Highest conversion result data. D11 is MSB.
3:0 Reserved Always reads zeros. Zeros must be written to these bits.
SERIAL INTERFACE
The I2C-compatible interface operates in all three speed modes. Standard mode (100kHz) and Fast mode
(400kHz) are functionally the same and will be referred to as Standard-Fast mode in this document. High-Speed
mode (3.4MHz) is an extension of Standard-Fast mode and will be referred to as Hs-mode in this document.
The following diagrams describe the timing relationships of the clock (SCL) and data (SDA) signals. Pull-up
resistors or current sources are required on the SCL and SDA busses to pull them high when they are not being
driven low. A logic zero is transmitted by driving the output low. A logic high is transmitted by releasing the output
and allowing it to be pulled-up externally. The appropriate pull-up resistor values will depend upon the total bus
capacitance and operating speed. The ADC081C021 offers extended ESD tolerance (8kV HBM) for the I2C bus
pins (SCL & SDA) allowing extension of the bus across multiple boards without extra ESD protection.
Basic I2C Protocol
The I2C interface is bi-directional and allows multiple devices to operate on the same bus. The bus consists of
master devices and slave devices which can communicate back and forth over the I2C interface. Master devices
control the bus and are typically microcontrollers, FPGAs, DSPs, or other digital controllers. Slave devices are
controlled by a master and are typically peripheral devices such as the ADC081C021. To support multiple
devices on the same bus, each slave has a unique hardware address which is referred to as the "slave address."
To communicate with a particular device on the bus, the controller (master) sends the slave address and listens
for a response from the slave. This response is referred to as an acknowledge bit. If a slave on the bus is
addressed correctly, it acknowledges (ACKs) the master by driving the SDA bus low. If the address doesn't
match a device's slave address, it not-acknowledges (NACKs) the master by letting SDA be pulled high. ACKs
also occur on the bus when data is being transmitted. When the master is writing data, the slave ACKs after
every data byte is successfully received. When the master is reading data, the master ACKs after every data
byte is received to let the slave know it wants to receive another data byte. When the master wants to stop
reading, it NACKs after the last data byte and creates a stop condition on the bus.
All communication on the bus begins with either a Start condition or a Repeated Start condition. The protocol for
starting the bus varies between Standard-Fast mode and Hs-mode. In Standard-Fast mode, the master
generates a Start condition by driving SDA from high to low while SCL is high. In Hs-mode, starting the bus is
more complicated. Please refer to High-Speed (Hs) Mode for the full details of a Hs-mode Start condition.
A Repeated Start is generated to address a different device or register, or to switch between read and write
modes. The master generates a Repeated Start condition by driving SDA low while SCL is high. Following the
Repeated Start, the master sends out the slave address and a read/write bit as shown in Figure 25. The bus
continues to operate in the same speed mode as before the Repeated Start condition.
22 Submit Documentation Feedback Copyright © 2008–2013, Texas Instruments Incorporated
Product Folder Links: ADC081C021 ADC081C027
SCL
SDA
START or
REPEATED
START
STOP
1 2 6 7 891 2 89
MSB
7-bit Slave Address R/W
Direction
BitAcknowledge
from the Device
MSB
Data Byte
*Acknowledge
or Not-ACK
ACK N/ACK
Repeated for the Lower Data Byte
and Additional Data Transfers
LSB LSB
*Note: In continuous mode, this bit must be an ACK from
the data receiver. Immediately preceding a STOP
condition, this bit must be a NACK from the master.
ADC081C021, ADC081C027
www.ti.com
SNAS447C FEBRUARY 2008REVISED MARCH 2013
All communication on the bus ends with a Stop condition. In either Standard-Fast mode or Hs-Mode, a Stop
condition occurs when SDA is pulled high while SCL is high. After a Stop condition, the bus remains idle until a
master generates another Start condition.
Please refer to the Philips I2C®Specification (Version 2.1 Jan, 2000) for a detailed description of the serial
interface.
Figure 25. Basic Operation.
Standard-Fast Mode
In Standard-Fast mode, the master generates a start condition by driving SDA from high to low while SCL is
high. The start condition is always followed by a 7-bit slave address and a Read/Write bit. After these 8 bits have
been transmitted by the master, SDA is released by the master and the ADC081C021 either ACKs or NACKs the
address. If the slave address matches, the ADC081C021 ACKs the master. If the address doesn't match, the
ADC081C021 NACKs the master.
For a write operation, the master follows the ACK by sending the 8-bit register address pointer to the ADC. Then
the ADC081C021 ACKs the transfer by driving SDA low. Next, the master sends the upper 8-bits to the
ADC081C021. Then the ADC081C021 ACKs the transfer by driving SDA low. For a single byte transfer, the
master should generate a stop condition at this point. For a 2-byte write operation, the lower 8-bits are sent by
the master. The ADC081C021 then ACKs the transfer, and the master either sends another pair of data bytes,
generates a Repeated Start condition to read or write another register, or generates a Stop condition to end
communication.
Aread operation can take place either of two ways:
If the address pointer is pre-set before the read operation, the desired register can be read immediately following
the slave address. In this case, the upper 8-bits of the register, set by the pre-set address pointer, are sent out
by the ADC. For a single byte read operation, the Master sends a NACK to the ADC and generates a Stop
condition to end communication after receiving 8-bits of data. For a 2-Byte read operation, the Master continues
the transmission by sending an ACK to the ADC. Then, the ADC sends out the lower 8-bits of the ADC register.
At this point, the master either sends; an ACK to receive more data or, a NACK followed by a Stop or Repeated
Start. If the master sends an ACK, the ADC sends the next upper data byte, and the read cycle repeats.
If the ADC081S021 address pointer needs to be set, the master needs to write to the device and set the address
pointer before reading from the desired register. This type of read requires a start, the slave address, a write bit,
the address pointer, a Repeated Start (if appropriate), the slave address, and a read bit (refer to Figure 30).
Following this sequence, the ADC sends out the upper 8-bits of the register. For a single byte read operation, the
Master must then send a NACK to the ADC and generate a Stop condition to end communication. For a 2-Byte
write operation, the Master sends an ACK to the ADC. Then, the ADC sends out the lower 8-bits of the ADC
register. At this point, the master sends either an ACK to receive more data, or a NACK followed by a Stop or
Repeated Start. If the master sends an ACK, the ADC sends another pair of data bytes, and the read cycle will
repeat. The number of data words that can be read is unlimited.
Copyright © 2008–2013, Texas Instruments Incorporated Submit Documentation Feedback 23
Product Folder Links: ADC081C021 ADC081C027
SCL
SDA
START
1 2 6 7 89
8-ELW0DVWHUFRGH³00001[[[´
Not-Acknowledge
from the Device
NACK
5
Standard-Fast Mode Hs-Mode
Repeated
START
1 2
MSB
7-bit Slave
Address
ADC081C021, ADC081C027
SNAS447C FEBRUARY 2008REVISED MARCH 2013
www.ti.com
High-Speed (Hs) Mode
For Hs-mode, the sequence of events to begin communication differs slightly from Standard-Fast mode.
Figure 26 describes this in further detail. Initially, the bus begins running in Standard-Fast mode. The master
generates a Start condition and sends the 8-bit Hs master code (00001XXX) to the ADC081C021. Next, the
ADC081C021 responds with a NACK. Once the SCL line has been pulled to a high level, the master switches to
Hs-mode by increasing the bus speed and generating a second Repeated Start condition (driving SDA low while
SCL is pulled high). At this point, the master sends the slave address to the ADC081C021, and communication
continues as shown above in the "Basic Operation" Diagram (see Figure 25).
When the master generates a Repeated Start condition while in Hs-mode, the bus stays in Hs-mode awaiting the
slave address from the master. The bus continues to run in Hs-mode until a Stop condition is generated by the
master. When the master generates a Stop condition on the bus, the bus must be started in Standard-Fast mode
again before increasing the bus speed and switching to Hs-mode.
Figure 26. Beginning Hs-Mode Communication
I2C Slave (Hardware) Address
The ADC has a seven-bit hardware address which is also referred to as a slave address. For the VSSOP-8
version of the ADC081C021, this address is configured by the ADR0 and ADR1 addres selection inputs. For the
ADC081C027, the address is configured by the ADR0 address selection input. ADR0 and ADR1 can be
grounded, left floating, or tied to VA. If desired, ADR0 can be set to VA/2 rather than left floating. The state of
these inputs sets the hardware address that the ADC responds to on the I2C bus (see Table 2). For the SOT-6
version of the ADC081C021, the hardware address is not pin-configurable and is set to 1010100. The diagrams
in COMMUNICATING WITH THE ADC081C021 describe how the I2C controller should address the ADC via the
I2C interface.
Pin compatible alternatives that provide additional address options to the SOT-6 version of the ADC081C021 and
the ADC081C027 are available.
Table 2. Slave Addresses
ADC081C027 ADC081C021 ADC081C021
(SOT-6) (SOT-6) (VSSOP-8)
Slave Address
[A6 - A0] ADR0 ALERT ADR1 ADR0
1010000 Floating ----------------- Floating Floating
1010001 GND ----------------- Floating GND
1010010 VA----------------- Floating VA
1010100 ----------------- Single Address GND Floating
1010101 ----------------- ----------------- GND GND
1010110 ----------------- ----------------- GND VA
1011000 ----------------- ----------------- VAFloating
1011001 ----------------- ----------------- VAGND
1011010 ----------------- ----------------- VAVA
24 Submit Documentation Feedback Copyright © 2008–2013, Texas Instruments Incorporated
Product Folder Links: ADC081C021 ADC081C027
TIME
VOLTAGE
VHIGH Limit
VHIGH - VHYST
ALERT pin
(Active Low)
Measured Voltage
Over Range Alert
)ODJVHWWR³1´
TIME
VOLTAGE
Measured Voltage
VHIGH Limit
VHIGH - VHYST
ALERT pin
(Active Low)
ADC081C021, ADC081C027
www.ti.com
SNAS447C FEBRUARY 2008REVISED MARCH 2013
ALERT FUNCTION
The ALERT function is an "out-of-range" indicator. At the end of every conversion, the measured voltage is
compared to the values in the VHIGH and VLOW registers. If the measured voltage exceeds the value stored in
VHIGH or falls below the value stored in VLOW, an alert condition occurs. The Alert condition is indicated in up to
three places. First, the alert condition always causes either or both of the alert flags in the Alert Status register to
go high. If the measured voltage exceeds the VHIGH limit, the Over Range Alert Flag is set. If the measured
voltage falls below the VLOW limit, the Under Range Alert Flag is set. Second, if the Alert Flag Enable bit is set in
the Configuration register, the alert condition also sets the MSB of the Conversion Result register. Third, if the
Alert Pin Enable bit is set in the Configuration register, the ALERT output becomes active (see Figure 27). The
ALERT output (ADC081S021 only) can be configured as an active high or active low output via the Polarity bit in
the Configuration register. If the Polarity bit is cleared, the ALERT output is configured as active low. If the
Polarity bit is set, the ALERT output is configured as active high.
The Over Range Alert condition is cleared when one of the following two conditions is met:
1. The controller writes a one to the Over Range Alert Flag bit.
2. The measured voltage goes below the programmed VHIGH limit minus the programmed VHYST value and the
Alert Hold bit is cleared in the Configuration register. (see Figure 27). If the Alert Hold bit is set, the alert
condition persists and only clears when a one is written to the Over Range Alert Flag bit.
The Under Range Alert condition is cleared when one of the following two conditions is met:
1. The controller writes a one to the Under Range Alert Flag bit.
2. The measured voltage goes above the programmed VLOW limit plus the programmed VHYST value and the
Alert Hold bit is cleared in the Configuration register. If the Alert Hold bit is set, the alert condition persists
and only clears when a one is written to the Under Range Alert Flag bit.
If the alert condition has been cleared by writing a one to the alert flag while the measured voltage still violates
the VHIGH or VLOW limits, an alert condition will occur again after the completion of the next conversion (see
Figure 28).
Alert conditions only occur if the input voltage exceeds the VHIGH limit or falls below the VLOW limit at the sample-
hold instant. The input voltage can exceed the VHIGH limit or fall below the VLOW limit briefly between conversions
without causing an alert condition.
Figure 27. Alert condition cleared when measured voltage crosses VHIGH - VHYST
Figure 28. Alert condition cleared by writing a "1" to the Alert Flag.
Copyright © 2008–2013, Texas Instruments Incorporated Submit Documentation Feedback 25
Product Folder Links: ADC081C021 ADC081C027
D7 D6 D5 D4 D3 D2 D1 D0
1 9 1 9
ACK
by
ADC
Start by
Master N/ACK*
by
Master
SCL
SDA Stop
by
Master
1 9
D15 D14 D13 D12 D11 D10 D9 D8 ACK
by
Master
Frame 1
Address Byte
from Master
Frame 2
Data Byte from
ADC
Frame 3
Data Byte from
ADC
R/W
A2 A0A1
A3A4A5A6
Repeat Frames
2 & 3 for
Continuous Mode
*Note: In continuous mode, this bit must be an ACK. Immediately
preceding a STOP condition, this bit must be a NACK.
ADC081C021, ADC081C027
SNAS447C FEBRUARY 2008REVISED MARCH 2013
www.ti.com
AUTOMATIC CONVERSION MODE
The automatic conversion mode configures the ADC to continually perform conversions without receiving "read"
instructions from the controller over the I2C interface. The mode is activated by writing a non-zero value into the
Cycle Time bits - D[7:5] - of the Configuration register (see Configuration Register). Once the ADC081C021
enters this mode, the internal oscillator is always enabled. The ADC's control logic samples the input at the
sample rate set by the cycle time bits. Although the conversion result is not transmitted by the 2-wire interface, it
is stored in the conversion result register and updates the various status registers of the device.
In automatic conversion mode, the out-of-range alert function is active and updates after every conversion. The
ADC can operate independently of the controller in automatic conversion mode. When the input signal goes "out-
of-range", an alert signal is sent to the controller. The controller can then read the status registers and determine
the source of the alert condition. Also, comparison and updating of the VMIN and VMAX registers occurs after every
conversion in automatic conversion mode. The controller can occasionally read the VMIN and/or VMAX registers to
determine the sampled input extremes. These register values persist until the user resets the VMIN and VMAX
registers. These two features are useful in system monitoring, peak detection, and sensing applications.
COMMUNICATING WITH THE ADC081C021
The ADC081C021's data registers are selected by the address pointer (see Address Pointer Register). To
read/write a specific data register, the pointer must be set to that register's address. The pointer is always written
at the beginning of a write operation. When the pointer needs to be updated for a read cycle, a write operation
must precede the read operation to set the pointer address correctly. On the other hand, if the pointer is preset
correctly, a read operation can occur without writing the address pointer register. The following timing diagrams
describe the various read and write operations supported by the ADC.
Reading from a 2-Byte ADC Register
The following diagrams indicate the sequence of actions required for a 2-Byte read from an ADC081C021
Register.
Figure 29. (a) Typical Read from a 2-Byte ADC Register with Preset Pointer
26 Submit Documentation Feedback Copyright © 2008–2013, Texas Instruments Incorporated
Product Folder Links: ADC081C021 ADC081C027
1 9 1 9
Ack
by
ADC
Start by
Master
R/W Ack
by
ADC
Frame 1
Address Byte
from Master
Frame 2
Pointer Byte
from Master
0 0 0 0 P2 P1 P0
D7 D6 D5 D4 D3 D2 D1 D0
1 9
ACK
by
ADC
NACK
by
Master
Stop
by
Master
1 9
Frame 3
Address Byte
from Master
Frame 4
Data Byte from
ADC
R/W
A2 A0A1
A3A4A5A6
Repeat
Start by
Master
A2 A0A1A3A4A5A6
SCL
SDA 0
SCL
(continued)
SDA
(continued)
D7 D6 D5 D4 D3 D2 D1 D0
1 9
ACK
by
ADC
Start by
Master NACK
by
Master
SCL
SDA Stop
by
Master
1 9
Frame 1
Address Byte
from Master
Frame 2
Data Byte from
ADC
R/W
A2 A0A1
A3A4A5A6
1 9 1 9
Ack
by
ADC
Start by
Master
R/W Ack
by
ADC
Frame 1
Address Byte
from Master
Frame 2
Pointer Byte
from Master
0 0 0 0 P2 P1 P0
D7 D6 D5 D4 D3 D2 D1 D0
1 9 1 9
ACK
by
ADC
N/ACK*
by
Master
Stop
by
Master
1 9
D15 D14 D13 D12 D11 D10 D9 D8 ACK
by
Master
Frame 3
Address Byte
from Master
Frame 4
Data Byte from
ADC
Frame 5
Data Byte from
ADC
R/W
A2 A0A1
A3A4A5A6
Repeat Frames
4 & 5 for
Continuous Mode
*Note: In continuous mode, this bit must be an ACK. Immediately
preceding a STOP condition, this bit must be a NACK.
Repeat
Start by
Master
A2 A0A1A3A4A5A6
SCL
SDA 0
SCL
(continued)
SDA
(continued)
ADC081C021, ADC081C027
www.ti.com
SNAS447C FEBRUARY 2008REVISED MARCH 2013
Figure 30. (b) Typical Pointer Set Followed by Immediate Read of a 2-Byte ADC Register
Reading from a 1-Byte ADC Register
The following diagrams indicate the sequence of actions required for a single Byte read from an ADC081C021
Register.
Figure 31. (a) Typical Read from a 1-Byte ADC Register with Preset Pointer
Figure 32. (b) Typical Pointer Set Followed by Immediate Read of a 1-Byte ADC Register
Copyright © 2008–2013, Texas Instruments Incorporated Submit Documentation Feedback 27
Product Folder Links: ADC081C021 ADC081C027
1 9 1 9
Ack
by
ADC
Start by
Master
R/W Ack
by
ADC
Frame 1
Address Byte
from Master
Frame 2
Pointer Byte
from Master
0 0 0 0 P2 P1 P0
D7 D6 D5 D4 D3 D2 D1 D0
1 9
ACK
by
ADC
NACK
by
Master
Stop
by
Master
1 9
Frame 3
Data Byte
from Master
Frame 4
Data Byte
from Master
A2 A0A1A3A4A5A6
SCL
SDA 0
SCL
(continued)
SDA
(continued) D15 D14 D13 D12 D11 D10 D9 D8
1 9 1 9
Start by
Master
R/W
Frame 1
Address Byte
from Master
D7 D6 D5 D4 D3 D2 D1 D0
1 9
Frame 3
Data Byte
from Master
Stop by
Master
SCL
SDA
Frame 2
Pointer Byte
from Master
ACK
by
ADC
ACK
by
ADC
ACK
by
ADC
A2 A0A1
A3A4A5A6 0 0 0 0 P2 P1 P00
ADC081C021, ADC081C027
SNAS447C FEBRUARY 2008REVISED MARCH 2013
www.ti.com
Writing to an ADC Register
The following diagrams indicate the sequence of actions required for writing to an ADC081C021 Register.
Figure 33. (a) Typical Write to a 1-Byte ADC Register
Figure 34. (b) Typical Write to a 2-Byte ADC Register
QUIET INTERFACE MODE
To improve performance at High Speed, operate the ADC in Quiet Interface Mode. This mode provides improved
INL and DNL performance in I2C Hs-Mode (3.4MHz). The Quiet Interface mode provides a maximum throughput
rate of 162ksps. Figure 35 describes how to read the conversion result register in this mode. Basically, the
Master needs to release SCL for at least 1µs before the MSB of every upper data byte. The diagram assumes
that the address pointer register is set to its default value.
Quiet Interface mode will only improve INL and DNL performance in Hs-Mode. Standard and Fast mode
performance is unaffected by the Quiet Interface mode.
28 Submit Documentation Feedback Copyright © 2008–2013, Texas Instruments Incorporated
Product Folder Links: ADC081C021 ADC081C027
1 9
ACK
by
ADC
Start by
Master
R/W
ACK
by
Master
Frame 1
Address Byte
from Master
D7 D6 D5 D4 D3 D2 D1 D0
1 9
NACK
by
Master
Stop
by
Master
1 9
D15 D14 D13 D12 D11 D10 D9 D8 ACK
by
Master
Frame 4
Upper Data Byte
from ADC
Frame 5
Lower Data Byte
from ADC
Repeat Frames
4 and 5 for
Continuous Mode
A2 A0A1A3A4A5A6
SCL
SDA
SCL
(continued)
SDA
(continued) D7 D6 D5 D4 D3 D2 D1 D0
1 9
1 9
D15 D14 D13 D12 D11 D10 D9 D8 ACK
by
Master
Frame 2
Upper Data Byte
from ADC
Frame 3
Lower Data Byte
from ADC
Interface Delay
tQuiet 8 1us
Interface Delay
tQuiet 8 1us
ADC081C021, ADC081C027
www.ti.com
SNAS447C FEBRUARY 2008REVISED MARCH 2013
Figure 35. Reading in Quiet Interface Mode
Copyright © 2008–2013, Texas Instruments Incorporated Submit Documentation Feedback 29
Product Folder Links: ADC081C021 ADC081C027
VIN
SCL
SDA
VA
ADC081C021
0.1 PF
GND
4.7 PF
22:
INPUT
470 pF
ALERT
5 k:RPRP
Regulated Supply
VDD
Controller
SCL
SDA
INTERRUPT
I2C BUS ...
ADC081C021, ADC081C027
SNAS447C FEBRUARY 2008REVISED MARCH 2013
www.ti.com
APPLICATIONS INFORMATION
TYPICAL APPLICATION CIRCUIT
A typical application circuit is shown in Figure 36. The analog supply is bypassed with a capacitor network
located close to the ADC081C021. The ADC uses the analog supply (VA) as its reference voltage, so it is very
important that VAbe kept as clean as possible. Due to the low power requirements of the ADC081C021, it is
possible to use a precision reference as a power supply.
The bus pull-up resistors (RP) should be powered by the controller's supply. It is important that the pull-up
resistors are pulled to the same voltage potential as VA. This will ensure that the logic levels of all devices on the
bus are compatible. If the controller's supply is noisy, an appropriate bypass capacitor should be added between
the controller's supply pin and the pull-up resistors. For Hs-mode applications, this bypass capacitance will
improve the accuracy of the ADC.
The value of the pull-up resistors (RP) depends upon the characteristics of each particular I2C bus. The I2C
specification describes how to choose an appropriate value. As a general rule-of-thumb, we suggest using a 1k
resistor for Hs-mode bus configurations and a 5kresistor for Standard or Fast Mode bus configurations.
Depending upon the bus capacitance, these values may or may not be sufficient to meet the timing requirements
of the I2C bus specification. Please see the I2C specification for further information.
Figure 36. Typical Application Circuit
BUFFERED INPUT
A buffered input application circuit is shown in Figure 37. The analog input is buffered by a TI LMP7731. The
non-inverting amplifier configuration provides a buffered gain stage for a single ended source. This application
circuit is good for single-ended sensor interface. The input must have a DC bias level that keeps the ADC input
signal from swinging below GND or above the supply (+5V in this case).
The LM4132, with its 0.05% accuracy over temperature, is an excellent choice as a reference source for the
ADC081C021.
30 Submit Documentation Feedback Copyright © 2008–2013, Texas Instruments Incorporated
Product Folder Links: ADC081C021 ADC081C027
TIME
VOLTAGE
Measured
Battery
Voltage
VLOW Limit
ALERT pin
(Active Low)
DISCHARGE CYCLE
VIN SCL
GND
VA
ADC081C021
REF
[LP2980-2.8] R
120 nF
20 kÖ
-+
SDA
ALERT
Low
Battery
Indicator
VBATT
To Controller...
20 kÖ
TIME
VOLTAGE
Measured
Battery
Voltage
VHigh Limit
ALERT pin
(Active Low)
RECHARGE CYCLE
VIN
SCL
SDA
ADDR
VA
ADC081C027
0.1 PF
GND
4.7 PF
R1
INPUT
Unregulated
Supply
+
-
LMP7731
R2
LM4132
4.7 PF
RS
CS
ADC081C021, ADC081C027
www.ti.com
SNAS447C FEBRUARY 2008REVISED MARCH 2013
Figure 37. Buffered Input Circuit
INTELLIGENT BATTERY MONITOR
The ADC081C021 is easily used as an intelligent battery monitor. The simple circuit shown in Figure 38, uses
the ADC081C021, the LP2980 fixed reference, and a resistor divider to implement an intelligent battery monitor
with a window supervisory feature. The window supervisory feature is implemented by the "out of range" alert
function. When the battery is recharging, the Over Range Alert will indicate that the charging cycle is complete
(see Figure 39). When the battery is nearing depletion, the Under Range Alert will indicate that the battery is low
(see Figure 40).
Figure 38. Intelligent Battery Monitor Circuit Figure 39. Recharge Cycle
Figure 40. Discharge Cycle
In addition to the window supervisory feature, the ADC081C021 will allow the controller to read the battery
voltage at any time during operation.
Copyright © 2008–2013, Texas Instruments Incorporated Submit Documentation Feedback 31
Product Folder Links: ADC081C021 ADC081C027
TIME
VOLTAGE
Measured
Battery Voltage
VLOW Limit
ALERT pin
(Active Low)
VLOW+VHYST
ADC081C021, ADC081C027
SNAS447C FEBRUARY 2008REVISED MARCH 2013
www.ti.com
The accurate voltage reading and the alert feature will allow a controller to improve the efficiency of a battery-
powered device. During the discharge cycle, the controller can switch to a low-battery mode, safely suspend
operation, or report a precise battery level to the user. During the recharge cycle, the controller can implement an
intelligent recharge cycle, decreasing the charge rate when the battery charge nears capacity.
Trickle Charge Controller
While a battery is discharging, the ADC081C021 can be used to control a trickle charge to keep the battery near
full capacity (see Figure 41). When the alert output is active, the battery will recharge. An intelligent recharge
cycle will prevent over-charging and damaging the battery. With a trickle charge, the battery powered device can
be disconnected from the charger at any time with a full charge.
Figure 41. Trickle Charge
LAYOUT, GROUNDING, AND BYPASSING
For best accuracy and minimum noise, the printed circuit board containing the ADC081C021 should have
separate analog and digital areas. The areas are defined by the locations of the analog and digital power planes.
Both of these planes should be located on the same board layer. A single, solid ground plane is preferred if
digital return current does not flow through the analog ground area. Frequently a single ground plane design will
utilize a "fencing" technique to prevent the mixing of analog and digital ground currents. Separate ground planes
should only be utilized when the fencing technique is inadequate. The separate ground planes must be
connected in one place, preferably near the ADC121C021. Special care is required to ensure that signals do not
pass over power plane boundaries. Return currents must always have a continuous return path below their
traces.
The ADC081C021 power supply should be bypassed with a 4.7µF and a 0.1µF capacitor as close as possible to
the device with the 0.1µF right at the device supply pin. The 4.7µF capacitor should be a tantalum type and the
0.1µF capacitor should be a low ESL type. The power supply for the ADC081C021 should only be used for
analog circuits.
Avoid crossover of analog and digital signals and keep the clock and data lines on the component side of the
board. The clock and data lines should have controlled impedances.
32 Submit Documentation Feedback Copyright © 2008–2013, Texas Instruments Incorporated
Product Folder Links: ADC081C021 ADC081C027
ADC081C021, ADC081C027
www.ti.com
SNAS447C FEBRUARY 2008REVISED MARCH 2013
REVISION HISTORY
Changes from Revision B (March 2013) to Revision C Page
Changed layout of National Data Sheet to TI format .......................................................................................................... 32
Copyright © 2008–2013, Texas Instruments Incorporated Submit Documentation Feedback 33
Product Folder Links: ADC081C021 ADC081C027
PACKAGE OPTION ADDENDUM
www.ti.com 11-Apr-2013
Addendum-Page 1
PACKAGING INFORMATION
Orderable Device Status
(1)
Package Type Package
Drawing Pins Package
Qty Eco Plan
(2)
Lead/Ball Finish MSL Peak Temp
(3)
Op Temp (°C) Top-Side Markings
(4)
Samples
ADC081C021CIMK/NOPB ACTIVE SOT DDC 6 1000 Green (RoHS
& no Sb/Br) CU SN Level-1-260C-UNLIM -40 to 105 X34C
ADC081C021CIMKX/NOPB ACTIVE SOT DDC 6 3000 Green (RoHS
& no Sb/Br) CU SN Level-1-260C-UNLIM -40 to 105 X34C
ADC081C021CIMM/NOPB ACTIVE VSSOP DGK 8 1000 Green (RoHS
& no Sb/Br) CU SN Level-1-260C-UNLIM X36C
ADC081C021CIMMX/NOPB ACTIVE VSSOP DGK 8 3500 Green (RoHS
& no Sb/Br) CU SN Level-1-260C-UNLIM X36C
ADC081C027CIMK/NOPB ACTIVE SOT DDC 6 1000 Green (RoHS
& no Sb/Br) CU SN Level-1-260C-UNLIM -40 to 105 X35C
ADC081C027CIMKX/NOPB ACTIVE SOT DDC 6 3000 Green (RoHS
& no Sb/Br) CU SN Level-1-260C-UNLIM -40 to 105 X35C
(1) The marketing status values are defined as follows:
ACTIVE: Product device recommended for new designs.
LIFEBUY: TI has announced that the device will be discontinued, and a lifetime-buy period is in effect.
NRND: Not recommended for new designs. Device is in production to support existing customers, but TI does not recommend using this part in a new design.
PREVIEW: Device has been announced but is not in production. Samples may or may not be available.
OBSOLETE: TI has discontinued the production of the device.
(2) Eco Plan - The planned eco-friendly classification: Pb-Free (RoHS), Pb-Free (RoHS Exempt), or Green (RoHS & no Sb/Br) - please check http://www.ti.com/productcontent for the latest availability
information and additional product content details.
TBD: The Pb-Free/Green conversion plan has not been defined.
Pb-Free (RoHS): TI's terms "Lead-Free" or "Pb-Free" mean semiconductor products that are compatible with the current RoHS requirements for all 6 substances, including the requirement that
lead not exceed 0.1% by weight in homogeneous materials. Where designed to be soldered at high temperatures, TI Pb-Free products are suitable for use in specified lead-free processes.
Pb-Free (RoHS Exempt): This component has a RoHS exemption for either 1) lead-based flip-chip solder bumps used between the die and package, or 2) lead-based die adhesive used between
the die and leadframe. The component is otherwise considered Pb-Free (RoHS compatible) as defined above.
Green (RoHS & no Sb/Br): TI defines "Green" to mean Pb-Free (RoHS compatible), and free of Bromine (Br) and Antimony (Sb) based flame retardants (Br or Sb do not exceed 0.1% by weight
in homogeneous material)
(3) MSL, Peak Temp. -- The Moisture Sensitivity Level rating according to the JEDEC industry standard classifications, and peak solder temperature.
(4) Multiple Top-Side Markings will be inside parentheses. Only one Top-Side Marking contained in parentheses and separated by a "~" will appear on a device. If a line is indented then it is a
continuation of the previous line and the two combined represent the entire Top-Side Marking for that device.
PACKAGE OPTION ADDENDUM
www.ti.com 11-Apr-2013
Addendum-Page 2
Important Information and Disclaimer:The information provided on this page represents TI's knowledge and belief as of the date that it is provided. TI bases its knowledge and belief on information
provided by third parties, and makes no representation or warranty as to the accuracy of such information. Efforts are underway to better integrate information from third parties. TI has taken and
continues to take reasonable steps to provide representative and accurate information but may not have conducted destructive testing or chemical analysis on incoming materials and chemicals.
TI and TI suppliers consider certain information to be proprietary, and thus CAS numbers and other limited information may not be available for release.
In no event shall TI's liability arising out of such information exceed the total purchase price of the TI part(s) at issue in this document sold by TI to Customer on an annual basis.
TAPE AND REEL INFORMATION
*All dimensions are nominal
Device Package
Type Package
Drawing Pins SPQ Reel
Diameter
(mm)
Reel
Width
W1 (mm)
A0
(mm) B0
(mm) K0
(mm) P1
(mm) W
(mm) Pin1
Quadrant
ADC081C021CIMK/NOPB SOT DDC 6 1000 178.0 8.4 3.2 3.2 1.4 4.0 8.0 Q3
ADC081C021CIMKX/NOP
BSOT DDC 6 3000 178.0 8.4 3.2 3.2 1.4 4.0 8.0 Q3
ADC081C021CIMM/NOP
BVSSOP DGK 8 1000 178.0 12.4 5.3 3.4 1.4 8.0 12.0 Q1
ADC081C021CIMMX/NO
PB VSSOP DGK 8 3500 330.0 12.4 5.3 3.4 1.4 8.0 12.0 Q1
ADC081C027CIMK/NOPB SOT DDC 6 1000 178.0 8.4 3.2 3.2 1.4 4.0 8.0 Q3
ADC081C027CIMKX/NOP
BSOT DDC 6 3000 178.0 8.4 3.2 3.2 1.4 4.0 8.0 Q3
PACKAGE MATERIALS INFORMATION
www.ti.com 26-Mar-2013
Pack Materials-Page 1
*All dimensions are nominal
Device Package Type Package Drawing Pins SPQ Length (mm) Width (mm) Height (mm)
ADC081C021CIMK/NOPB SOT DDC 6 1000 210.0 185.0 35.0
ADC081C021CIMKX/NOP
BSOT DDC 6 3000 210.0 185.0 35.0
ADC081C021CIMM/NOPB VSSOP DGK 8 1000 210.0 185.0 35.0
ADC081C021CIMMX/NOP
BVSSOP DGK 8 3500 367.0 367.0 35.0
ADC081C027CIMK/NOPB SOT DDC 6 1000 210.0 185.0 35.0
ADC081C027CIMKX/NOP
BSOT DDC 6 3000 210.0 185.0 35.0
PACKAGE MATERIALS INFORMATION
www.ti.com 26-Mar-2013
Pack Materials-Page 2
IMPORTANT NOTICE
Texas Instruments Incorporated and its subsidiaries (TI) reserve the right to make corrections, enhancements, improvements and other
changes to its semiconductor products and services per JESD46, latest issue, and to discontinue any product or service per JESD48, latest
issue. Buyers should obtain the latest relevant information before placing orders and should verify that such information is current and
complete. All semiconductor products (also referred to herein as “components”) are sold subject to TI’s terms and conditions of sale
supplied at the time of order acknowledgment.
TI warrants performance of its components to the specifications applicable at the time of sale, in accordance with the warranty in TI’s terms
and conditions of sale of semiconductor products. Testing and other quality control techniques are used to the extent TI deems necessary
to support this warranty. Except where mandated by applicable law, testing of all parameters of each component is not necessarily
performed.
TI assumes no liability for applications assistance or the design of Buyers’ products. Buyers are responsible for their products and
applications using TI components. To minimize the risks associated with Buyers’ products and applications, Buyers should provide
adequate design and operating safeguards.
TI does not warrant or represent that any license, either express or implied, is granted under any patent right, copyright, mask work right, or
other intellectual property right relating to any combination, machine, or process in which TI components or services are used. Information
published by TI regarding third-party products or services does not constitute a license to use such products or services or a warranty or
endorsement thereof. Use of such information may require a license from a third party under the patents or other intellectual property of the
third party, or a license from TI under the patents or other intellectual property of TI.
Reproduction of significant portions of TI information in TI data books or data sheets is permissible only if reproduction is without alteration
and is accompanied by all associated warranties, conditions, limitations, and notices. TI is not responsible or liable for such altered
documentation. Information of third parties may be subject to additional restrictions.
Resale of TI components or services with statements different from or beyond the parameters stated by TI for that component or service
voids all express and any implied warranties for the associated TI component or service and is an unfair and deceptive business practice.
TI is not responsible or liable for any such statements.
Buyer acknowledges and agrees that it is solely responsible for compliance with all legal, regulatory and safety-related requirements
concerning its products, and any use of TI components in its applications, notwithstanding any applications-related information or support
that may be provided by TI. Buyer represents and agrees that it has all the necessary expertise to create and implement safeguards which
anticipate dangerous consequences of failures, monitor failures and their consequences, lessen the likelihood of failures that might cause
harm and take appropriate remedial actions. Buyer will fully indemnify TI and its representatives against any damages arising out of the use
of any TI components in safety-critical applications.
In some cases, TI components may be promoted specifically to facilitate safety-related applications. With such components, TI’s goal is to
help enable customers to design and create their own end-product solutions that meet applicable functional safety standards and
requirements. Nonetheless, such components are subject to these terms.
No TI components are authorized for use in FDA Class III (or similar life-critical medical equipment) unless authorized officers of the parties
have executed a special agreement specifically governing such use.
Only those TI components which TI has specifically designated as military grade or “enhanced plastic” are designed and intended for use in
military/aerospace applications or environments. Buyer acknowledges and agrees that any military or aerospace use of TI components
which have not been so designated is solely at the Buyer's risk, and that Buyer is solely responsible for compliance with all legal and
regulatory requirements in connection with such use.
TI has specifically designated certain components as meeting ISO/TS16949 requirements, mainly for automotive use. In any case of use of
non-designated products, TI will not be responsible for any failure to meet ISO/TS16949.
Products Applications
Audio www.ti.com/audio Automotive and Transportation www.ti.com/automotive
Amplifiers amplifier.ti.com Communications and Telecom www.ti.com/communications
Data Converters dataconverter.ti.com Computers and Peripherals www.ti.com/computers
DLP® Products www.dlp.com Consumer Electronics www.ti.com/consumer-apps
DSP dsp.ti.com Energy and Lighting www.ti.com/energy
Clocks and Timers www.ti.com/clocks Industrial www.ti.com/industrial
Interface interface.ti.com Medical www.ti.com/medical
Logic logic.ti.com Security www.ti.com/security
Power Mgmt power.ti.com Space, Avionics and Defense www.ti.com/space-avionics-defense
Microcontrollers microcontroller.ti.com Video and Imaging www.ti.com/video
RFID www.ti-rfid.com
OMAP Applications Processors www.ti.com/omap TI E2E Community e2e.ti.com
Wireless Connectivity www.ti.com/wirelessconnectivity
Mailing Address: Texas Instruments, Post Office Box 655303, Dallas, Texas 75265
Copyright © 2013, Texas Instruments Incorporated