EMC filters
3-line filters
Sine-wave output filters
Rated current 6 to 35 A
Series/Type: B84143V*R027
Date: January 2006
EPCOS AG 2006. Reproduction, publication and dissemination of this data sheet and the
information contained therein without EPCOS’ prior express consent is prohibited.
3-line filters B84143V*R027
Sine-wave output filters
Sine-wave filters for 3-phase systems
Rated voltage 440/250 V AC, 50/60 Hz
Rated current 6 to 35 A
Construction
3-line filter
Metal case
Features
Easy to install
Space-saving design
Degree of protection: IP 201)
Motor cables of more than 100 m possible
Minimized motor noise and eddy current losses
in the motor windings
Applications
Sine-wave output filters for frequency converters in
variable speed drivers
solar systems
–UPS
Terminals
Finger-safe terminal blocks
Marking
Marking on component:
Manufacturer’s logo, ordering code,
rated voltage, rated current, rated temperature,
climatic category, date code, terminal assignment
Minimum marking on packaging:
Manufacturer’s logo, ordering code
Further versions
Higher currents for sine-wave output filters on request
EMC sine-wave filters on request
1) To IEC 60529
Please read Cautions and warnings and
Important notes at the end of this document. 01/06 2
3-line filters B84143V*R027
Sine-wave output filters
Typical circuit diagram
Converter Load
U1 U2
V1 V2
W1 W2
SSB1572-D-E
Technical data and measuring conditions
Rated voltage VR 440/250 V AC, 50/60 Hz
Rated current IR Referred to 40 °C ambient temperature
Test voltage Vtest 1770 V DC, 2 s (line/line)
2700 V DC, 2 s (lines/case)
Overload capability (thermal) 1.5 · IR for 1 min per hour
Converter output frequency fM 0 … 100 Hz
Converter pulse frequency fP 6 … 16 kHz
Voltage drop (input to output) V t IR and 50 Hz
Capacitive reactive current Iq At 400/230 V AC, 50 Hz (typical value)
Max. voltage Vpeak
(e.g. overshot pulse edge max.)
700 V
Max. dv/dt at input 5 kV/µs
Climatic category (IEC 60068-1) 25/100/21 (–25 °C/+100 °C/21 days damp heat test)
A
Characteristics and ordering codes
VR
AC
V
IR
A
Terminal
cross section
mm2
Iq
A
V
V
Rtyp
m
Approx.
weight
kg
Ordering code
440/250 6 4 0.24 10 200 5.2 B84143V0006R027
12 4 0.48 8 66 7.9 B84143V0012R027
16 4 0.81 8 49 8.3 B84143V0016R027
25 6 1.20 7 27 11.1 B84143V0025R027
35 6 1.60 7 15 16.6 B84143V0035R027
Please read Cautions and warnings and
Important notes at the end of this document. 01/06 3
3-line filters B84143V*R027
Sine-wave output filters
Dimensional drawings
B84143V0006R027 (6 A)
372
350
40 27.5 95
20
37.5
45
54.5
80
380
PE
U2
V2
W2 W1
V1
PE
U1
365±0.3
6.5
91
70±0.3
LOAD Inverter
Marking
Thread M5
Terminal blocks 4 mm 2
Tightening torque 0.6 ... 0.8 Nm SSB1567-C-E
B84143V0012R027, B84143V0016R027 (12 A, 16 A)
372
350
40 27.5 95
20
37.5
80
89.5
115
W1
V1
PE
U1
365±0.3
380
6.5
91
70±0.3
LOAD Inverter
Marking
Thread M5
PE
U2
V2
W2
Terminal blocks 4 mm
2
Tightening torque 0.6 ... 0.8 Nm
SSB1568-K-E
Please read Cautions and warnings and
Important notes at the end of this document. 01/06 4
3-line filters B84143V*R027
Sine-wave output filters
B84143V0025R027 (25 A)
381
40 27.5 350
20
37.5
104
114
95
150
PE
U2
V2
W2 W1
V1
PE
U1
365±0.3
380
6.5
91
70±0.3
Marking
LOAD Inverter
Thread M5
Terminal blocks 6 mm
2
Tightening torque 1.5 ... 1.8 Nm
SSB1570-W-E
B84143V0035R027 (35 A)
PE
U2
V2
W2 W1
V1
PE
U1
40 45
20 55
104
114
350
381
150
130
365±0.3
380
6.5
126
105±0.3
Thread M5
LOAD Marking Inverter
Terminal blocks 6 mm
2
Tightening torque 1.5 ... 1.8 Nm
SSB1571-5-E
Please read Cautions and warnings and
Important notes at the end of this document. 01/06 5
EMC filters
Cautions and warnings
Important information
Please read all safety and warning notes carefully before installing the EMC filter and putting it into
operation (see ). The same applies to the warning signs on the filter. Please ensure that the signs
are not removed nor their legibility impaired by external influences.
Death, serious bodily injury and substantial material damage to equipment may occur if the appro-
priate safety measures are not carried out or the warnings in the text are not observed.
Using according to the terms
The EMC filters may be used only for their intended application within the specified values in low-
voltage networks in compliance with the instructions given in the data sheets and the data book.
The conditions at the place of application must comply with all specifications for the filter used.
Warnings
It shall be ensured that only qualified persons (electricity specialists) are engaged on work such
as planning, assembly, installation, operation, repair and maintenance. They must be provided
with the corresponding documentation.
Danger of electric shock. EMC filters contain components that store an electric charge. Danger-
ous voltages can continue to exist at the filter terminals for longer than five minutes even after
the power has been switched off.
The protective earth connections shall be the first to be made when the EMC filter is installed and
the last to be disconnected. Depending on the magnitude of the leakage currents, the particular
specifications for making the protective-earth connection must be observed.
Impermissible overloading of the EMC filter, such as impermissible voltages at higher frequen-
cies that may cause resonances etc. can lead to destruction of the filter housing.
EMC filters must be protected in the application against impermissible exceeding of the rated
currents by suitable overcurrent protective.
6 01/06
EMC filters
Important notes
The following applies to all products named in this publication:
1. Some parts of this publication contain statements about the suitability of our products for
certain areas of application. These statements are based on our knowledge of typical
requirements that are often placed on our products in the areas of application concerned. We
nevertheless expressly point out that such statements cannot be regarded as binding
statements about the suitability of our products for a particular customer application. As
a rule, EPCOS is either unfamiliar with individual customer applications or less familiar with them
than the customers themselves. For these reasons, it is always ultimately incumbent on the
customer to check and decide whether an EPCOS product with the properties described in the
product specification is suitable for use in a particular customer application.
2. We also point out that in individual cases, a malfunction of passive electronic components
or failure before the end of their usual service life cannot be completely ruled out in the
current state of the art, even if they are operated as specified. In customer applications
requiring a very high level of operational safety and especially in customer applications in which
the malfunction or failure of a passive electronic component could endanger human life or health
(e.g. in accident prevention or life-saving systems), it must therefore be ensured by means of
suitable design of the customer application or other action taken by the customer (e.g.
installation of protective circuitry or redundancy) that no injury or damage is sustained by third
parties in the event of malfunction or failure of a passive electronic component.
3. The warnings, cautions and product-specific notes must be observed.
4. In order to satisfy certain technical requirements, some of the products described in this
publication may contain substances subject to restrictions in certain jurisdictions (e.g.
because they are classed as “hazardous”). Useful information on this will be found in our
Material Data Sheets on the Internet (www.epcos.com/material). Should you have any more
detailed questions, please contact our sales offices.
5. We constantly strive to improve our products. Consequently, the products described in this
publication may change from time to time. The same is true of the corresponding product
specifications. Please check therefore to what extent product descriptions and specifications
contained in this publication are still applicable before or when you place an order.
We also reserve the right to discontinue production and delivery of products.
Consequently, we cannot guarantee that all products named in this publication will always be
available.
6. Unless otherwise agreed in individual contracts, all orders are subject to the current version
of the “General Terms of Delivery for Products and Services in the Electrical Industry”
published by the German Electrical and Electronics Industry Association (ZVEI).
7. The trade names EPCOS, EPCOS-Jones, Baoke, CeraDiode, CSSP, MLSC, PhaseCap,
PhaseMod, SIFI, SIKOREL, SilverCap, SIMID, SIOV, SIP5D, SIP5K, UltraCap, WindCap are
trademarks registered or pending in Europe and in other countries. Further information will be
found on the Internet at www.epcos.com/trademarks.
7 01/06
Mouser Electronics
Authorized Distributor
Click to View Pricing, Inventory, Delivery & Lifecycle Information:
EPCOS:
B84143V6R27 B84143V16R27 B84143V35R27 B84143V25R27 B84143V12R27