SPECIFICATION
25W AC-DC Reliable Green Industrial Adaptor GST25B serie s
GST25B05-P1J
GST25B07-P1J
GST25B09-P1J
GST25B12-P1J
GST25B15-P1J
GST25B18-P1J
GST25B24-P1J
GST25B28-P1J
GST25B48-P1J
ORDER NO.
SAFETY MODEL NO.
DC VOLTAGE Note.2
RATED CURRENT
CURRENT RANGE
RATED POWER (max.)
RIPPLE & NOISE (max.) Note.3
OUTPUT
SETUP, RISE, HOLD UP TIME
FREQUENCY RANGE
EFFICIENCY (Typ.)
AC CURRENT
INPUT
ENVIRONMENT
INRUSH CURRENT (max.)
LEAKAGE CURRENT(max.)
SAFETY STANDARDS Note. 8
SAFETY &
EMC
(Note. 9)
WORKING TEMP.
WORKING HUMIDITY
STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
MTBF
DIMENSION
OTHERS
NOTE
PACKING
PROTECTION
5V
GST25B05
7.5V
GST25B07
9V
GST25B09
12V
GST25B12
15V
GST25B15
18V
GST25B18
24V
GST25B24
28V
GST25B28
48V
GST25B48
4.0A 2.93A 2.55A 2.08A 1.66A 1.38A 1.04A 0.89A 0.52A
0 ~ 4.0A 0 ~ 2.93A 0 ~ 2.55A 0 ~ 2.08A 0 ~ 1.66A 0 ~ 1.38A 0 ~ 1.04A
0 ~ 0.89A
0 ~ 0.52A
80mVp-p 80mVp-p 80mVp-p 100mVp-p 100mVp-p 150mVp-p 150mVp-p 150mVp-p
VOLTAGE TOLERANCE Note.4
LINE REGULATION Note.5
LOAD REGULATION Note.6
±5.0% ±5.0% ±5.0% ±3.0% ±3.0% ±3.0% ±2.0% ±2.0% ±2.0%
±1.0% ±1.0% ±1.0% ±1.0% ±1.0% ±1.0% ±1.0%
±2.0%
±1.0%
±2.0%
±1.0%
±2.0%±5.0% ±5.0% ±5.0% ±3.0% ±3.0% ±3.0%
47 ~ 63Hz
0.25mA / 240VAC
WITHSTAND VOLTAGE
ISOLATION RESISTANCE
I/P-O/P:4242VDC
500Khrs min. MIL-HDBK-217F(25℃)
20% ~ 90% RH non-condensing
10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes
79*54*33mm (L*W*H)
CONNECTOR
PLUG
CABLE
20W 22W 23W 25W 25W 25W 25W 25W 25W
OVERLOAD
OVER VOLTAGE
110 ~ 150% rated output power
Protection type : Hiccup mode, recovers automatically after fault condition is removed
Protection type : Clamp by zener diode
I/P-O/P:100M Ohms / 500VDC / 25℃/ 70% RH
See page 4~5 ; Other type available by customer requested
See page 4~5 ; Other type available by customer requested
80mVp-p
85 ~ 264VAC
81.5% 84.5% 85% 86.5% 87% 87% 88% 88% 89%
110 ~ 140% rated output voltage
1000ms, 30ms, 50ms/230VAC 1500ms, 30ms, 15ms/115VAC at full load
0.6A / 115VAC 0.35A / 230VAC
-30 ~ +70℃ (Refer to "Derating Curve")
-40 ~ +85℃, 10 ~ 95% RH non-condensing
±0.03% / ℃ (0 ~ 50℃)
191.5g; 60pcs/12.5Kg/1.15CUFT
℃
(as available on http://www.meanwell.com)
※:https://www.meanwell.com/serviceDisclaimer.aspx
Cold start 35A / 115VAC 65A / 230VAC
VOLTAGE RANGE Note.7
UL62368-1, CSA C22.2 No. 62368-1, TUV EN62368-1, BSMI CNS14336, CCC GB4943.1,AS/NZS 60950.1,PSE J62368-1 ,
BIS IS13252, KC K60950-1, approved EAC TP TC 004 approved; SIRIM MS IEC60950-1 (optional)
EMC IMMUNITY
EMC EMISSION
Parameter Standard
EN55032(CISPR32),FCC PART 15 / CISPR22
CAN ICES-3(B)/NMB-3(B),CNS13438,GB17625.1
EAC TP TC 020,MSIP KN32
EN61000-3-2,GB9254
Test Level / Note
Class B
-------
EN61000-3-3
Class B
Class A
Parameter
ESD
Standard
EN61000-4-2
Test Level /Note
EN61000-4-3
EN61000-4-4
EN61000-4-6
EN61000-4-5
EN61000-4-8
EN61000-4-11 >95% dip 0.5 periods, 30% dip 25 periods,
>95% interruptions 250 periods
EN55032(CISPR32),FCC PART 15 / CISPR22
CAN ICES-3(B)/NMB-3(B),CNS13438,GB17625.1
EAC TP TC 020,MSIP KN32
μ μ
Conducted emission
Radiated emission
Harmonic current
Voltage flicker
EFT bursts
Surge susceptibility
Level 3, 8KV air; Level 2, 4KV contact
Conducted susceptibility
Level 2, 3V/m
Level 3, 1KV/Line-Line
Level 2, 3A/m
Level 2, 3V
Level 2, 1KV
RF field susceptibility
Magnetic field immunity
Voltage dips , interruption
File Name:GST25B-SPEC 2020-10-20