1
2.0mm
2.0mm
Ultra-Small Surface Mount Coaxial Connectors - 1.18mm Mated Height
W.FL2 Series
2014.11w
Features
1. Nominal mated height of 1.18 mm
(Max. 1.3 mm)
2. Small board footprint
As with X.FL, W.FL Series, the receptacles
occupies an area of 3.4 mm
2
and share the same
land pattern.
Note: The W. FL2 Series is not compatible with X.FL, W.FL
Series.
3. Extremely light weight
The world's smallest and lightest class of coaxial
connectors.
Receptacle: 5.0mg
Right angle plug:16.7mg(062), 17.4mg(040),
15.3mg(032)
4. Frequency range up to 6 GHz
DC to 3 GHz: V.S.W.R. of 1.3 max.
3 GHz to 6 GHz: V.S.W.R. of 1.4 max.
5. Automatic board placement
Packaged on tape-and-reel the receptacles can
be placed with vacuum nozzles of the automatic
placement equipment.
6.
Plugs are terminated with ultra-fine coaxial
(fluorinated resin insulated) cable
The use of ultra-fine coaxial(fluorinated resin
insulated)cables on these connectors offer the
ability to complete connections in small,
confined spaces with a smooth, easy operation.
7. Simple connector mating / un-mating
Use of the available mating / un-mating tools
assures correct connection / disconnection of
the plug and receptacle.
8.
Halogen-free*(Receptacle, Plug(HF type))
*As defined by IEC61249-2-21
Br-900 ppm maximum, Cl-900 ppm maximum, Cl+Br
combined-1,500 ppm maximum.
W. FL2 Series W. FL Series
[MAX1.55]
1.4
1.18
[MAX1.3]
W.FL2-LP-032HF(06)
W.FL2-LP-040(06)
W.FL2-LP-040HF(06)
W.FL2-LP-062HF
W.FL-LP-040(06)
W.FL-LP-040HF(06)
W. FL SeriesW. FL2 Series
W.FL2-R-SMT-1 W.FL-R-SMT-1
(#( 8VWaZ
L#;A'Eaj\
9^V#&#%!%#-&!%#*
&#&-
PB6M&#(R
L#;A'"G"HBI"&
GZXZeiVXaZ
Mated height comparison (with W.FL Series)
Occupied Mounting Area
W. FL2 Plug and Receptacle
Fig.2
Fig.1
2
W.FL2 SeriesUltra-Small Surface Mount Coaxial Connectors - 1.18mm Mated Height
Specifications
Rating
Nominal characteristic impedance 50ø Operating temperature range -40°C to +90°C
(90%RH max.)
Frequency range DC to 6 GHz Storage temperature range
Item Specification
1. Contact resistance 20 mø max. (center contact), l0 mø max. (outer contact)
2. Insulation resistance 500 Mø min., 100 V DC
3. Withstanding voltage 200 V AC / 1 minute
4. V.S.W.R. 1.3 max. (DC to 3 GHz)
1.4 max. (3 GHz to 6 GHz)
* V.S.W.R. Measurement
as shown on the block diagram below.
Note: Verify connection and measurement setup.
Note1. The term “storage” refers to products stored for long period of time prior to mounting and use.
Note1: Cable assembly measurements with SMA conversion
adapters mated with W.FL2 plug at each end of the
100cm long ultra-fine coaxial cable.
Note2: Receptacles mounted on a 50 ohms glass epoxy board.
Measurements were conducted with SMA conversion
adapters attached.
Network Analyzer
Test Set
Test Port
TerminationD.U.T
Test Post Cable
-30°C to +70°C
(90%RH max.)Note 1
MaterialsMaterials
Plugs – Right Angle
Part Material Finish
Shell Phosphor bronze Silver plated/Gold plated(062)
Insulator PBT Color: Black, UL94V-0
Insulator (HF type) LCP Color: Milky white, UL94V-0
Female center contact Phosphor bronze Gold plated
Receptacle
Part Material Finish
Shell Phosphor bronze Silver plated
Insulator LCP Color: Black, UL94V-0
Male center contact Brass Gold plated
3
W.FL2 SeriesUltra-Small Surface Mount Coaxial Connectors - 1.18mm Mated Height
Cable Assembly(Plug)
[Plugs can be ordered only as terminated cable assemblies.]
2
0.91
3.3
W.FL2-LP-040(06), W.FL2-LP-040HF(06) (Applicable cable : outer diameter 0.81)
2
3.3
0.89
W.FL2-LP-062HF (Applicable cable : outer diameter 1.0)
3.35
0.91 2
W.FL2-LP-032HF(06) (Applicable cable : outer diameter 0.5)
4
W.FL2 SeriesUltra-Small Surface Mount Coaxial Connectors - 1.18mm Mated Height
BHow to specify Cable Assembly
Ordering information Standard Tolerances for (L)
L (mm)
[Double-ended cable assembly]
L (mm)
[Single-ended cable assembly]
Ordering infometioan
(L)mm
Standard tolerance(mm)
*L=35 to 200 ±4
1L=200 to 500 ±8
1L=500 to 1000 ±12
L=Longer than 1000mm
1000 ±1.5% of (L)
Note: Minimum available length(L) is 35mm.
Used plug: W.FL2-LP-040(06), W.FL2-LP-040HF(06)
W.FL2 2LP HF6 04N「」TV −A−(L)
❶❷
W.FL2 LP HF6 04N「」TV −A−(L)
❷❸❹
Double-
Ended
Single-
Ended
Used plug: W.FL2-LP-062HF
W.FL2 2LP HF 062N
「」
SC −A−(L)
❶❷
W.FL2 LP HF 062N「」SC −A−(L)
❶❷
Double-
Ended
Single-
Ended
Used plug: W.FL2-LP-032HF(06)
W.FL2 2LP HF6 032N
「」TS −A−(L)
❶❷
W.FL2 LP HF6 032N「」TS −A−(L)
❶❷
Double-
Ended
Single-
Ended
Series name : WFL2, W.FL2
Assembly type LP: Single ended
2LP: Double ended
Environmental
compliant
HF6: Halogen-free
6: RoHS compliant
Cable type 04N: 0.81mm dia. ultra-fine
coaxial cable
Cable color 1: White, 2: Black
Cable outer conductor TV: Tin Plated braided wire
Total length (mm) Length(L)
Series name : WFL2, W.FL2
Assembly type LP: Single ended
2LP: Double ended
Environmental
compliant
HF6: Halogen-free
Cable type
032N: 0.5mm dia. ultra-fine coaxial cable
Cable color 1: White, 2: Black
Cable outer conductor TS: Tin Plated fiber or paper
covered copper winding wire
Total length (mm) Length(L)
Series name : WFL2, W.FL2
Assembly type LP: Single ended
2LP: Double ended
Environmental
compliant HF: Halogen-free
Cable type
062N: 1.0mm dia. ultra-fine coaxial cable
Cable color 1: Gray, 2: Black, 3: White
Cable outer conductor
SC: Outer tin plated braided wire
Inner conductor silver plated
Total length (mm) Length(L)
5
W.FL2 SeriesUltra-Small Surface Mount Coaxial Connectors - 1.18mm Mated Height
Receptacles
0.7
0.3
1.7
2
0.3
SIG
GND
1.3
1.7
2
0.25
2.6
1.4
0.5
SIG GND
No conductive traces
in this area
1.31.3
1.5
0.65
BRecommended PCB
mounting pattern (Note 1)
Note 1: The land pattern is the same as
that of the X.FL, W.FL series
connectors.
BEmbossed Carrier Tape Dimensions (IEC 60286-3 compliant)
Embossed Carrier Tape Dimensions Reel Dimensions
-
)'
&'
*#* &#,*
φ
&#*
'
¢
((%
&(#*
¢
&(
¢
'&
6
BViZg^Va
EH
L]^iZ
6
H86A:;G::
Embossed Carrier Tape Dimensions
(W.FL2-R-SMT-1(60) 8mm pitch)
&#,**#*
&'
')
)
φ
&#*
(W.FL2-R-SMT-1(80) 4mm pitch)
Part No. HRS No. Packaging RoHS
W.FL2-R-SMT-1(60) 331-0315-4 60 Reel (5,000 pcs/reel) Yes
W.FL2-R-SMT-1(80) 331-0315-4 80 Reel (10,000 pcs/reel)
6
W.FL2 SeriesUltra-Small Surface Mount Coaxial Connectors - 1.18mm Mated Height
Conversion Adapters
Note:
Used for performance measurements only.
The W.FL2 mating side has lower retention force when
mated with the corresponding part.
Note:
Used for performance measurements only.
The W.FL/W.FL2 mating side has lower retention force
when mated with the corresponding part.
Note: When mating with corresponding part (W.FL2-R-
SMT-1) must be pressed down and held to make
complete connection.
SMA Conversion Adapter (W.FL2/W.FL side plug – SMA side jack)
SMA Conversion Adapter
SMA Conversion Adapter (W.FL2 side jack – SMA side plug)
Receptacle Inspection Adapter (W.FL2/W.FL)
Used for inspecting the performance parameters of the cable assembly.
8HEX
(10.15)
(4.05)
6
1/4-36UNS-2A
13.8
Ø6.35
5.6
(18.14)
(4)
6
1/4-36UNS-2A
Ø6.35
5.5
(4.4) 1
(7.9) 4.2
12.1
M5∞0.5
7HEX
All dimensions: mm
All dimensions: mm
All dimensions: mm
All dimensions: mm
Part No.
HRMP-W.FL2J
HRS No. Packaging RoHS
Yes311-0394-6 1
Part No.
HRMJ-W.FLP(40)
HRS No. Packaging RoHS
Yes311-0368-6 40 1
Part No.
HRMJ-W.FL2P-ST3
HRS No. Packaging RoHS
Yes311-0417-0 1
Part No.
W.FL-R-1
HRS No. Packaging RoHS
Yes331-0483-9 1
7
W.FL2 SeriesUltra-Small Surface Mount Coaxial Connectors - 1.18mm Mated Height
BTools
Plug - Mating /Unmating (W.FL2-LP-040HF/032HF)
This tool is for mating and unmating a plug.
Plug - Mating (Space saving type)
This tool is used for mating a plug.
Plug-Mating/Unmating (W.FL2-LP-062HF)
This tool is for mating and unmating W.FL2-LP-062HF plug.
M#;A
+%
&%
'
BVi^c\ZcY JcbVi^c\ZcY
M#;ABVg`^c\
Part No. HRS No. RoHS
X.FL-LP-IN.OUT1 331-0715-2 Yes
Note: Can be used with X.FL plug.
(100)
Ø10
8
Part No. HRS No. RoHS
W.FL-LP-IN 331-0323-2 Yes
Note: Can be used with W.FL, X.FL plugs.
(60)
10
2
Mating end Unmating end
Part No. HRS No. RoHS
W.FL2-LP-IN.OUT 331-0321-7 Yes
8
W.FL2 SeriesUltra-Small Surface Mount Coaxial Connectors - 1.18mm Mated Height
Precautions
1. Plugs
Use of the extraction
tool is absolutely
mandatory. Any attempt
of unmating by pulling
on the cable may result
in damage and affect
the mechanical /
electrical performance.
• Unmating
• Mating
(1) Recommended reflow
temperature profile
q
The temperature of the printed circuit board
surface temperature at the points of contact
with the terminals.
w Reflow soldering should be performed at a
printed circuit surface temperature of 250°C
max.
e In individual applications the actual
temperature may vary, depending on the
solder paste type, volume / thickness and
board size / thickness. Consuly your solder
paste and equipment manufacturer for specific
recommendations.
(2)
Recommended metal mask thickness
(3) Reflow cycles
2. Receptacles
80
100
120
140
160
180
200
220
240
260
[ç]
Preheat
(130 to 180ç)
230ç
220ç
50 seconds max.
120 seconds max.
60 seconds max.
Time
250 ç max. for
10 seconds
(1) Mating / Unmating
(3) Precautions
q Align the mating axes of the
plug and the receptacle.
w Confirm that the plug is
positioned to be guided.
(The both axes are aligned and
the plug is positioned stably.)
e Remove the tool by carefully
pulling it up.
q To disconnect connectors, insert the extraction side of insertion and extraction jig and perform as
described in the diagram below.
Do not twist connectors excessively during mating / unmating.
Removal
completed
Insert the extraction side of the
tool under the mated plug at the
cableconnectionside(asshown).
Tiltthetoolasshown
andlifttheplugcable
assembly.
:@
>chZgiidgZXZeiVXaZEaj\e^X`je GZbdkVad[
i]Zidda
L#;A'"AE"Eaj\ L#;A'"G"HBI"&
:@.;=
Do not apply any pull forces after the bending
of the cable.
(2) Pull forces on the
cable after connectors
are mated
0.1 mm to 0.12 mm
2 times
(1) Operating environment
The connectors are not designed to operate in the following environments:
Exposed to a excessive amounts of fine particles and dust
Regions and places having a high density of sulfur dioxide, hydrogen sulfide, nitrogen dioxide or other
corrosive gasses.
Environments having large rapid variations in temperature.
(2) Storage conditions -
Receptacle
Store in the Hirose Electric packaging.
Temperature: -10 to +40ç, Humidity: 85% max.
Use within 6 months of delivery.
Receptacles for which the storage period has elapsed must be tested for solderability to the PC board mounting surface.
3. Operating environment and storage conditions
L#;A'"AE" 'CbVm#
%+'%)%ineZ
&CbVm#
%('ineZ
L#;A'"G"HBI"&
2-6-3,Nakagawa Chuoh,Tsuzuki-Ku,Yokohama-Shi 224-8540,JAPAN
TEL: +81-45-620-3526 Fax: +81-45-591-3726
http://www.hirose.com
http://www.hirose-connectors.com
®
The characteristics and the specifications contained herein are for reference purpose. Please refer to the latest customer drawings prior to use.
The contents of this catalog are current as of date of 11/2014. Contents are subject to change without notice for the purpose of improvements.
Mouser Electronics
Authorized Distributor
Click to View Pricing, Inventory, Delivery & Lifecycle Information:
Hirose Electric:
W.FL-2LP-04N1-A-(400) W.FL-2LP-04N1-A-(180) W.FL-2LP-04N1-A-(800) W.FL-2LP-04N1-A-(240) W.FL-2LP-
04N1-A-(220) W.FL-2LP-04N1-A-(260) W.FL-2LP-04N1-A-(600) W.FL-2LP-04N1-A-(110) W.FL-2LP-04N1-A-(150)
W.FL-2LP-04N1-A-(130) W.FL-2LP-04N1-A-(170) W.FL-2LP-04N1-A-(160) W.FL-2LP-04N1-A-(120) W.FL-2LP-04N1-
A-(290) W.FL-2LP-04N1-A-(900) W.FL-2LP-04N1-A-(190) W.FL-2LP-04N1-A-(200) W.FL-2LP-04N1-A-(230) W.FL-
2LP-04N1-A-(270) W.FL-2LP-04N1-A-(280) W.FL-2LP-04N1-A-(140) W.FL-2LP-04N1-A-(300) W.FL-2LP-04N1-A-
(700) W.FL-2LP-04N1-A-(60) W.FL-2LP-04N2-A-(90) W.FL-2LP-04N2-A-(70) W.FL-2LP-04N2-A-(40) W.FL-2LP-
04N1-A-(80) W.FL-2LP-04N1-A-(40) W.FL-2LP-04N1-A-(50) W.FL-2LP-04N2-A-(35) W.FL-2LP-04N2-A-(50) W.FL2-
R-SMT-1(10) W.FL-2LP-04N2-A-(60) W.FL-2LP-04N2-A-(80) W.FL-2LP-04N1-A-(250) W.FL-2LP-04N1-A-(70) W.FL-
2LP-04N1-A-(90) W.FL-2LP-04N2-A-(300) W.FL-2LP-04N2-A-(130) W.FL-2LP-04N2-A-(700) W.FL-2LP-04N2-A-(150)
W.FL-2LP-04N2-A-(110) W.FL-2LP-04N2-A-(190) W.FL-2LP-04N2-A-(170) W.FL-2LP-04N1-A-(35) W.FL-2LP-04N2-
A-(1000) W.FL-2LP-04N2-A-(180) W.FL-2LP-04N2-A-(600) W.FL-2LP-04N2-A-(400) W.FL-2LP-04N2-A-(800) W.FL-
2LP-04N2-A-(140) W.FL-2LP-04N2-A-(120) W.FL-2LP-04N2-A-(160) W.FL-2LP-04N2-A-(500) W.FL-2LP-04N2-A-
(200) W.FL-2LP-04N2-A-(900) W.FL-2LP-04N1-A-(100) W.FL-2LP-04N1-A-(1000) W.FL-2LP-04N1-A-(500) W.FL-
2LP-04N2-A-(100) W.FL2-2LP-04N2-A-(300) W.FL2-2LP-04N1-A-(400) W.FL2-2LP-04N1-A-(200) W.FL2-2LP-04N2-
A-(150) W.FL2-2LP-04N1-A-(50) W.FL2-2LP-04N2-A-(200) W.FL2-2LP-04N1-A-(150) W.FL2-2LP-04N1-A-(300)
W.FL2-2LP-04N2-A-(400) W.FL2-2LP-04N1-A-(500) W.FL2-R-SMT-1(60) W.FL2-R-SMT-1(40) W.FL2-R-SMT-1(80)