40
5.7” (145mm) DC Bypass Blower 1200 WATT, 240 VOLT
Part Number
Standard Flow High Flow Ultra Flow
Blower Data Unit of
117416 M*119152 M*119154 M*
Measure
117415 E*119151 E*119153 E* 119155 E*
Stages 3 1 2 1
Vacuum, Max. (Sealed Vacuum) in. H2O 135 50 91 33
mBar 335 124 226 82
Pressure, Max. (Sealed Pressure) in. H
2
O 144 54 97 39
mBar 357 134 241 97
Flow Rate, Max. (Open Flow) CFM 82 190 156 307
L/sec 39 90 74 145
Inlet/Outlet Diameter inches 1.25 1.75 1.75 2.75/2.50
(Dimension “D” above) mm 31.75 44.45 44.45 69.85/63.50
Length (Dimension “I” above) inches 2.12 .47 1.53 .70
mm 53.85 11.94 38.86 17.78
Length (Dimension “L” above) inches 6.87 5.11 6.35 5.47
mm 174.50 128.77 161.29 138.94
Typical Performance Points
Air Flow Pressure
0 CFM in. H2O 144.3 54.0 97.0 39.2
20 CFM in. H2O 129.1 53.9 92.5 38.0
40 CFM in. H2O 102.9 51.1 85.8 37.5
60 CFM in. H2O 60.8 47.0 75.9 35.3
80 CFM in. H2O 10.8 43.2 62.3 33.5
100 CFM in. H2O 37.0 40.5 31.4
120 CFM in. H2O 29.4 32.1 28.0
140 CFM in. H2O 22.3 15.0 25.4
160 CFM in. H2O 14.2 21.5
180 CFM in. H2O18.5
200 CFM in. H2O16.1
220 CFM in. H2O13.1
240 CFM in. H2O10.0
260 CFM in. H2O7.4
280 CFM in. H2O4.3
300 CFM in. H2O1.0
NOTES:
• Nominal input voltage: 240 Volts AC RMS +/- 10%, 50/60Hz
• Input current: 5 amps AC RMS maximum
• Temperature: Working Air: 0°C to 50°C, Ambient Air: 0°C to 50°C, Storage Air: -40°C to 85°C
• Dielectric Testing: 1500 volts AC RMS 60Hz applied for one second between input pins and ground, 3mA leakage max.
• Maximum Approximate Weight: 6 lbs.
*These part numbers are available through AMETEK Rotron distributors.