40
5.7” (145mm) DC Bypass Blower 1200 WATT, 240 VOLT
Part Number
Standard Flow High Flow Ultra Flow
Blower Data Unit of
117416 M*119152 M*119154 M*
Measure
117415 E*119151 E*119153 E* 119155 E*
Stages 3 1 2 1
Vacuum, Max. (Sealed Vacuum) in. H2O 135 50 91 33
mBar 335 124 226 82
Pressure, Max. (Sealed Pressure) in. H
2
O 144 54 97 39
mBar 357 134 241 97
Flow Rate, Max. (Open Flow) CFM 82 190 156 307
L/sec 39 90 74 145
Inlet/Outlet Diameter inches 1.25 1.75 1.75 2.75/2.50
(Dimension “D” above) mm 31.75 44.45 44.45 69.85/63.50
Length (Dimension “I” above) inches 2.12 .47 1.53 .70
mm 53.85 11.94 38.86 17.78
Length (Dimension “L” above) inches 6.87 5.11 6.35 5.47
mm 174.50 128.77 161.29 138.94
Typical Performance Points
Air Flow Pressure
0 CFM in. H2O 144.3 54.0 97.0 39.2
20 CFM in. H2O 129.1 53.9 92.5 38.0
40 CFM in. H2O 102.9 51.1 85.8 37.5
60 CFM in. H2O 60.8 47.0 75.9 35.3
80 CFM in. H2O 10.8 43.2 62.3 33.5
100 CFM in. H2O 37.0 40.5 31.4
120 CFM in. H2O 29.4 32.1 28.0
140 CFM in. H2O 22.3 15.0 25.4
160 CFM in. H2O 14.2 21.5
180 CFM in. H2O18.5
200 CFM in. H2O16.1
220 CFM in. H2O13.1
240 CFM in. H2O10.0
260 CFM in. H2O7.4
280 CFM in. H2O4.3
300 CFM in. H2O1.0
NOTES:
Nominal input voltage: 240 Volts AC RMS +/- 10%, 50/60Hz
Input current: 5 amps AC RMS maximum
Temperature: Working Air: 0°C to 50°C, Ambient Air: 0°C to 50°C, Storage Air: -40°C to 85°C
Dielectric Testing: 1500 volts AC RMS 60Hz applied for one second between input pins and ground, 3mA leakage max.
Maximum Approximate Weight: 6 lbs.
*These part numbers are available through AMETEK Rotron distributors.
41
5.7” (145mm) DC Bypass Blower 1200 WATT, 240 VOLT
Speed Control: E (Electrical): Pulse Width Modulation or Analog input voltage (User Supplied), 0 to 10 Volts DC Nominal, 10mA Maximum, 3 to 15 volts DC
Maximum. Access to sensitivity adjustment for 0-10 VDC speed control. (Ref. pin connection)
M (Mechanical): A potentiometer is available for speed control of the blower. The potentiometer can be preset for a specific speed. Access to speed adjustment.
Regulatory Agency Certification: T.U.V. Rheinland Bauart Certification* is qualified per EN60950 under License No. 9571008; Underwriters Laboratories, Inc. is
qualified per UL507 under File E 94403; Canadian Standards Association is qualified per C22.2#113 under File LR 43448.
Miscellaneous: Intake & exhaust tubes, all cooling ducts and vents must not be obstructed. Intake and exhaust must be free of grease, oil, or foreign particles.
Amp housing #350809-1 (to be supplied by customer), mates with post header assembly.
IEC 801 testing has been completed, and specific data can be provided upon request.
Mating harness available upon request. Refer to (page 84) for specific part numbers.
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The
performance data on this page depicts typical performance under controlled laboratory conditions, data is corrected to 0.075 lb./ft3 air density (29.92” Hg @ 70° F.).
Actual performance will vary depending on the operating environment and application. AMETEK Rotron products are not designed for use with volatile, hazardous or
corrosive gases. Blower housings are not sealed, slight air/gas leakage will occur. AMETEK Rotron products are not designed for and should not be used in medical
life support applications. AMETEK reserves the right to revise its products without notification. The above characteristics represent standard products. For product