SECTION 4
Magnecraft Solution Guide 105A
Magnecraft Solution Guide 105AMagnecraft Solution Guide 105A
Since acquiring this line of miniature
SSRs from Grayhill, this product has
continuously evolved both functionally
and visually. The 70S2 Series relays are
designed for medium-power loads. The
design incorporates a triac output for AC
loads and MOSFETs for DC loads. The
70S2 Series relays use optical isolation
to protect the control from transients. The
70S2 compact package is available in
a combination of screw, fast-on or PCB
terminals. Its compact size makes it ideal
for designs where space is limited. The
70S2 Series relays have excellent
thermal performance.
Small Packages
Ideal for Tight Designs..
Eight Different Packages
Wide Choice of Design
Options.
Optically Isolated
Input Isolated from Output.
Zero Cross Switching
Reduced Current Surges for
Most Loads.
Internal Snubber
Excellent Transient Protection.
70S2 S
70S2 N
70S2 V (3 Amp)
70S2 V (5 Amp)
2.3
(57.7)
0.6
(14.8)
1.7
(43.2)
1.1
(27.8)
1
(25.4)
1.8
(44.9)
INPUT
+
+
INPUT OUTPUT AC INPUT
POWER SUPPLY
WIRING DIAGRAM
SSR
-
+
-
LOAD
1.4
(35.9)
2.3
(57.5)
A'
A
SECTION A - A'
1
(24.3)
- Switch up to 5 Amps
- Integrated Thermal
Management
- PCB Mount
- Switch up to 25
Amps
- Screw Terminals
- Panel Mount
- Switch up to 12 Amps
- Blade Terminals
- Panel Mount
Advantages of the 70S2 Series
4/28
Magnecraft Solution Guide 105A
Magnecraft Solution Guide 105AMagnecraft Solution Guide 105A
70S2 H
70S2 F
70S2 K
70S2 L
We’re very pleased at the breadth of products
and solutions we are able to offer engineers and
designers. And this is just the beginning.
We will continue to develop high value products -
with innovative features not offered anywhere else
in the industry.
70S2 M
- Switch up to 10 Amps
- Solder Terminals
- PCB/Panel Mount
- Switch up to 6 Amps
- Solder Terminals
- PCB/Panel Mount
- Switch up to 4 Amps
- Socket Compatible
- Switch up to 2.5 Amps
- Solder Terminals
- PCB Mount
- Switch up to 4 Amps
- Solder Terminals
- PCB Mount
www.magnecraft.com 847-441-2540
SECTION 4
4/29
SECTION 4
Magnecraft Solution Guide 105A
Magnecraft Solution Guide 105A
General Specifications (@ 25° C)
UL Recognized
File No. E258297
70S2-04-B
SPST-NO
Triac
3 / 5
24….140 AC
Zero Cross
300
75 / 50
60 / 300
6 / 10
1.6 AC
400 AC
3….32 DC
1 DC
1….19
3 DC
8.3
8.3
4000 AC
4000 AC
UR, CSA
-40…+125
-40…+100
0.5
25 (0.9)
70S2 Series Solid State Relays/3, 5 Amp, V Style
On
Off
Terminals to Chassis
Input to Output
Standard version
Storage
Operation
Output Characteristics
Number and type of Contacts
Switching Device
Current Rating
Switching voltage
Switching Type
Maximum Rate of Rise Off State Voltage (dv/dt)
Min. Load current to maintain on
Non-Repetitive Surge Current (1 cycle)
Max. Off state leakage current (rms)
Typical On State Voltage Drop (rms)
Minimum Peak Blocking Voltage
Input Characteristics
Voltage Range
Must Release Voltage
Typical Input Current @ 5VDC or 240VAC
Max. Reverse Control Voltage
Performance Characteristics
Operating time (response time)
Dielectric strength
Environment
Product certifications
Ambient air temperature
around the device
Miscellaneous Characteristics
Thermal Resistance (Junction to Case)
Weight
70S2-04-D
SPST-NO
Triac
3 / 5
8….50 AC
Zero Cross
300
75 / 50
60 / 300
3 / 10
1.6 AC
200 AC
3….32 DC
1 DC
1….19
3 DC
8.3
8.3
4000 AC
4000 AC
UR, CSA
-40…+125
-40…+100
0.5
25 (0.9)
Units
A
V
V/us
mA
A
mA
V
V
V
V
mA
V
ms
ms
V
V
°C
°C
°C/W
g (oz)
70S2-05-D
SPST-NO
Triac
3
8….50 AC
Zero Cross
300
75
60
3
1.6 AC
200 AC
6….32 DC
1 DC
1….6
3 DC
8.3
8.3
4000 AC
4000 AC
UR, CSA
-40…+125
-40…+100
0.5
25 (0.9)
Integrated Thermal
Management
Output Terminals
Input
Terminals
Printed Circuit
Board Mounting
(UL 508)
4/30
Magnecraft Solution Guide 105A
SECTION 4
Magnecraft Solution Guide 105A
NEW
NEW
NEW
NEW
NEW
70S2 V (3 Amp) 70S2 V (5 Amp)
www.magnecraft.com 847-441-2540
70S2-05-B
SPST-NO
Triac
3
24….140 AC
Zero Cross
300
75
60
6
1.6 AC
400 AC
6….32 DC
1 DC
1….6
3 DC
8.3
8.3
4000 AC
4000 AC
UR, CSA
-40…+125
-40…+100
0.5
25 (0.9)
70S2-04-C
SPST-NO
Triac
3 / 5
24….280 AC
Zero Cross
300
75 / 50
60 / 300
6 / 10
1.6 AC
600 AC
3….32 DC
1 DC
1….19
3 DC
8.3
8.3
4000 AC
4000 AC
UR, CSA
-40…+125
-40…+100
0.5
25 (0.9)
70S2-05-C
SPST-NO
Triac
3
24….280 AC
Zero Cross
300
75
60
6
1.6 AC
600 AC
6….32 DC
1 DC
1….6
3 DC
8.3
8.3
4000 AC
4000 AC
UR, CSA
-40…+125
-40…+100
0.5
25 (0.9)
70S2-01-A
SPST-NO
MOSFET
3
3….60 DC
DC Switching
N/A
100
5 (1 SEC)
10 µ A
1.2 DC
105 DC
3….15 DC
1 DC
5….40
3 DC
75 µs
500 µs
4000 AC
4000 AC
UR, CSA
-40…+125
-40…+100
0.5
25 (0.9)
70S2-02-A
SPST-NO
MOSFET
3
3….60 DC
DC Switching
N/A
100
6 (1 SEC)
10 µ A
1.2 DC
105 DC
9….30 DC
1 DC
5….17
3 DC
75 µs
500 µs
4000 AC
4000 AC
UR, CSA
-40…+125
-40…+100
0.5
25 (0.9)
4/31
SECTION 4
Magnecraft Solution Guide 105A
Magnecraft Solution Guide 105A
IN OUT
0.4
(10.2)
1.7
(43.2)
1
(26.4)
0.9
(22.9)
1.1
(27.9)
0.2
(5.7)
0.3
(7.6)
0.4
(10.2)
0.1
(2.5)
0.4
(10.2)
0.04 DIA.
(1)
UL Recognized
File No. E258297
70S2 Series Solid State Relays/3, 5 Amp, V Style continued
Integrated Thermal
Management
Output Terminals
Input
Terminals
Printed Circuit
Board Mounting
4/32
Magnecraft Solution Guide 105A
SECTION 4
Magnecraft Solution Guide 105A
NEW
NEW
NEW
NEW
NEW
70S2 V (3 Amp) 70S2 V (5 Amp)
Standard Part Numbers
Part Number Builder
Maximum Continuous Current vs. Ambient Temperature
BOLD-FACED PART NUMBERS ARE NORMALLY STOCKED
www.magnecraft.com 847-441-2540
Input Voltage
Range Output Voltage
Range Contact
Configuration Switching Type Rated Current
Load (Amps)
Series
70S2
Package Style
V = V STYLE
N = N STYLE
S = S STYLE
F = F STYLE
M = M STYLE
H = H STYLE
L = L STYLE
K = K STYLE
Input Voltage
01 = 3 to 15 VDC, DC/DC RELAYS
02 = 9 to 30 VDC, DC/DC RELAYS
03 = 3 to 30 VDC, 25 A S PACK
04 = 3 to 30 VDC (OR 32 VDC), DC/AC RELAYS
05 = 6 to 30 VDC (OR 32 VDC), DC/AC RELAYS
Output Voltage
A = 3 to 60 VDC
B = 24 to 140 VAC
C = 24 to 280 VAC
D = 8 to 50 VAC
Output Current
02 = 2.5 AMPS
03 = 3 AMPS
04 = 4 AMPS
05 = 5 AMPS
06 = 6 AMPS
10 = 10 AMPS
12 = 12 AMPS
25 = 25 AMPS
DC Operated
70S2-04-D-03-V
70S2-05-D-03-V
70S2-04-D-05-V
70S2-04-B-03-V
70S2-05-B-03-V
70S2-04-B-05-V
70S2-04-C-03-V
70S2-05-C-03-V
70S2-04-C-05-V
70S2-01-A-03-V
70S2-02-A-03-V
3….32 VDC
6….32 VDC
3….32 VDC
3….32 VDC
6….32 VDC
3….32 VDC
3….32 VDC
6….32 VDC
3….32 VDC
3….15 VDC
9….30 VDC
8….50 VAC
8….50 VAC
8….50 VAC
24….140 VAC
24….140 VAC
24….140 VAC
24….280 VAC
24….280 VAC
24….280 VAC
3….60 VDC
3….60 VDC
SPST-NO
SPST-NO
SPST-NO
SPST-NO
SPST-NO
SPST-NO
SPST-NO
SPST-NO
SPST-NO
SPST-NO
SPST-NO
Zero Cross
Zero Cross
Zero Cross
Zero Cross
Zero Cross
Zero Cross
Zero Cross
Zero Cross
Zero Cross
Zero Cross
Zero Cross
3
3
5
3
3
5
3
3
5
3
3
4/33
SECTION 4
Magnecraft Solution Guide 105A
Magnecraft Solution Guide 105A
General Specifications (@ 25° C)
Maximum Continuous Current vs. Ambient Temperature
14
12
10
8
6
4
2
STYLE M, 10A
STYLE M, 6A
STYLE F, 4A
25
20
15
10
5
STYLE S, 25A
STYLE N & S, 12A
STYLE N & S, 6A
UL Recognized
File No. E258297
70S2-04-C
SPST-NO
Triac
6 / 12
24….280 AC
Zero Cross
300
75 / 100
60 / 150
6
1.6 AC
600 AC
3….30 DC
1 DC
7….16
3 DC
8.3
8.3
3000 AC
3000 AC
UR, CSA
-40…+125
-40…+100
4
47 (1.7)
1.0
70S2 Series Solid State Relays/N and S Style
On
Off
Terminals to Chassis
Input to Output
Standard version
Storage
Operation
Output Characteristics
Number and type of Contacts
Switching Device
Current Rating
Switching voltage
Switching Type
Maximum Rate of Rise Off State Voltage (dv/dt)
Min. Load current to maintain on
Non-Repetitive Surge Current (1 cycle)
Max. Off state leakage current (rms)
Typical On State Voltage Drop (rms)
Minimum Peak Blocking Voltage
Input Characteristics
Voltage Range
Must Release Voltage
Typical Input Current @ 5VDC or 240VAC
Max. Reverse Control Voltage
Performance Characteristics
Operating time (response time)
Dielectric strength
Environment
Product certifications
Ambient air temperature
around the device
Miscellaneous Characteristics
Thermal Resistance (Junction to Case)
Weight
Mounting Screw Torque
70S2-04-B
SPST-NO
Triac
6 / 12
24….140 AC
Zero Cross
300
75 / 100
60 / 150
6
1.6 AC
400 AC
3….30 DC
1 DC
7….16
3 DC
8.3
8.3
3000 AC
3000 AC
UR, CSA
-40…+125
-40…+100
4
47 (1.7)
1.0
Units
A
V
V/us
mA
A
mA
V
V
V
V
mA
V
ms
ms
V
V
°C
°C
°C/W
g (oz)
Nm
70S2-05-B
SPST-NO
Triac
6 / 12
24….140 AC
Zero Cross
300
75 / 100
60 / 150
6
1.6 AC
400 AC
6….30 DC
1 DC
6….10
3 DC
8.3
8.3
3000 AC
3000 AC
UR, CSA
-40…+125
-40…+100
4
47 (1.7)
1.0
Output Terminals
Input
Terminals
Panel
Mounting
(UL 508)
4/34
Magnecraft Solution Guide 105A
SECTION 4
Magnecraft Solution Guide 105A
70S2 S70S2 N
www.magnecraft.com 847-441-2540
70S2-05-C
SPST-NO
Triac
6 / 12
24….280 AC
Zero Cross
300
75 / 100
60 / 150
6
1.6 AC
600 AC
6….30 DC
1 DC
6….10
3 DC
8.3
8.3
3000 AC
3000 AC
UR, CSA
-40…+125
-40…+100
4
47 (1.7)
1.0
70S2-03-B
SPST-NO
Triac
25
24….140 AC
Zero Cross
300
100
300
6
1.7 AC
400 AC
3….30 DC
1 DC
7….16
3 DC
8.3
8.3
3000 AC
3000 AC
UR, CSA
-40…+125
-40…+100
4
47 (1.7)
1.0
70S2-03-C
SPST-NO
Triac
25
24….280 AC
Zero Cross
300
100
300
6
1.7 AC
600 AC
3….30 DC
1 DC
6….10
3 DC
8.3
8.3
3000 AC
3000 AC
UR, CSA
-40…+125
-40…+100
4
47 (1.7)
1.0
70S2-01-A
SPST-NO
MOSFET
5
3….60 DC
DC Switching
N/A
100
7 (1 SEC)
10 µ A
1.85 DC
105 DC
3….15 DC
1 DC
5….40
3 DC
75 µs
750 µs
2500 AC
2500 AC
UR, CSA
-40…+125
-40…+100
4
47 (1.7)
1.0
70S2-02-A
SPST-NO
MOSFET
5
3….60 DC
DC Switching
N/A
100
7 (1 SEC)
10 µ A
1.85 DC
105 DC
9….30 DC
1 DC
5….17
3 DC
75 µs
750 µs
2500 AC
2500 AC
UR, CSA
-40…+125
-40…+100
4
35 (1.2)
1.0
4/35
SECTION 4
Magnecraft Solution Guide 105A
Magnecraft Solution Guide 105A
0.9
(22.9)
1
(10.2)
0.8
(19.1)
1.9
1.2
2.2
0.9
(22.9)
(15.3)
0.2
(26.2)
0.6
(4.5)
(31.2) (47.5)
(55.9)
0.4
240 VA C
+
3-30
VDC6 A
OUTPUT
INPUT
240 VA C3-30
VDC
+6 A
-
0.032 (0.8)
TERMINALS
0.02 (0.5)
TERMINALS
NOTE: MEASURE TERMINAL HEIGHT BY ZEROING
HEIGHT INDICATOR IN CENTER OF POTTING
SURFACE THEN CHECK TERMINAL HEIGHT.
.250 TERMINAL - .315 MINIMUM
.187 TERMINAL - .245 MINIMUM
OUTPUT
INPUT
0.2
(4.4)
1.2 MAX
(31.2)
1.9
(47.5)
2.2
(55.9)
0.4
(10.2)
1 MAX
(26.2)
0.9 MAX
(22.9)
0.5
(12.7)
0.9
(22.9)
0.187
(4.75)
0.25
(6.5)
70S2 N
70S2 S
70S2 Series Solid State Relays/N and S Style continued
Output Terminals
Input
Terminals
Panel
Mounting
4/36
Magnecraft Solution Guide 105A
SECTION 4
Magnecraft Solution Guide 105A
70S2 S70S2 N
Standard Part Numbers
Part Number Builder
BOLD-FACED PART NUMBERS ARE NORMALLY STOCKED
www.magnecraft.com 847-441-2540
Input Voltage
Range Output Voltage
Range Contact
Configuration Switching Type Rated Current
Load (Amps)
Series
70S2
Package Style
V = V STYLE
N = N STYLE
S = S STYLE
F = F STYLE
M = M STYLE
H = H STYLE
L = L STYLE
K = K STYLE
Input Voltage
01 = 3 to 15 VDC, DC/DC RELAYS
02 = 9 to 30 VDC, DC/DC RELAYS
03 = 3 to 30 VDC, 25 A S PACK
04 = 3 to 30 VDC (OR 32 VDC), DC/AC RELAYS
05 = 6 to 30 VDC (OR 32 VDC), DC/AC RELAYS
Output Voltage
A = 3 to 60 VDC
B = 24 to 140 VAC
C = 24 to 280 VAC
D = 8 to 50 VAC
Output Current
02 = 2.5 AMPS
03 = 3 AMPS
04 = 4 AMPS
05 = 5 AMPS
06 = 6 AMPS
10 = 10 AMPS
12 = 12 AMPS
25 = 25 AMPS
DC Operated
70S2-04-B-06-N
70S2-05-B-06-N
70S2-04-B-12-N
70S2-05-B-12-N
70S2-04-C-06-N
70S2-05-C-06-N
70S2-04-C-12-N
70S2-05-C-12-N
70S2-01-A-05-N
70S2-04-B-06-S
70S2-05-B-06-S
70S2-04-B-12-S
70S2-05-B-12-S
70S2-03-B-25-S
70S2-04-C-06-S
70S2-05-C-06-S
70S2-04-C-12-S
70S2-05-C-12-S
70S2-03-C-25-S
70S2-01-A-05-S
70S2-02-A-05-S
3….30 VDC
6….30 VDC
3….30 VDC
6….30 VDC
3….30 VDC
6….30 VDC
3….30 VDC
6….30 VDC
3….15 VDC
3….30 VDC
6….30 VDC
3….30 VDC
6….30 VDC
3….30 VDC
3….30 VDC
6….30 VDC
3….30 VDC
6….30 VDC
3….30 VDC
3….15 VDC
9….30 VDC
24….140 VAC
24….140 VAC
24….140 VAC
24….140 VAC
24….280 VAC
24….280 VAC
24….280 VAC
24….280 VAC
3….60 VDC
24….140 VAC
24….140 VAC
24….140 VAC
24….140 VAC
24….140 VAC
24….280 VAC
24….280 VAC
24….280 VAC
24….280 VAC
24….280 VAC
3….60 VDC
3….60 VDC
SPST-NO
SPST-NO
SPST-NO
SPST-NO
SPST-NO
SPST-NO
SPST-NO
SPST-NO
SPST-NO
SPST-NO
SPST-NO
SPST-NO
SPST-NO
SPST-NO
SPST-NO
SPST-NO
SPST-NO
SPST-NO
SPST-NO
SPST-NO
SPST-NO
Zero Cross
Zero Cross
Zero Cross
Zero Cross
Zero Cross
Zero Cross
Zero Cross
Zero Cross
DC Switching
Zero Cross
Zero Cross
Zero Cross
Zero Cross
Zero Cross
Zero Cross
Zero Cross
Zero Cross
Zero Cross
Zero Cross
DC Switching
DC Switching
6
6
12
12
6
6
12
12
5
6
6
12
12
25
6
6
12
12
25
5
5
4/37
SECTION 4
Magnecraft Solution Guide 105A
Magnecraft Solution Guide 105A
General Specifications (@ 25° C)
Maximum Continuous Current vs. Ambient Temperature
4
5
6
7
3
2
1
4
3
2
1
Style F, 3 Amp Style F, 4 Amp
UL Recognized
File No. E258297
70S2 Series Solid State Relays/F and M Style
On
Off
Terminals to Chassis
Input to Output
Standard version
Storage
Operation
Output Characteristics
Number and type of Contacts
Switching Device
Current Rating
Switching voltage
Switching Type
Maximum Rate of Rise Off State Voltage (dv/dt)
Min. Load current to maintain on
Non-Repetitive Surge Current (1 cycle)
Max. Off state leakage current (rms)
Typical On State Voltage Drop (rms)
Minimum Peak Blocking Voltage
Input Characteristics
Voltage Range
Must Release Voltage
Typical Input Current @ 5VDC or 240VAC
Max. Reverse Control Voltage
Performance Characteristics
Operating time (response time)
Dielectric strength
Environment
Product certifications
Ambient air temperature
around the device
Miscellaneous Characteristics
Thermal Resistance (Junction to Case)
Weight
Mounting Screw Torque
70S2-04-B
SPST-NO
Triac
4 | 6 | 10
24….140 AC
Zero Cross
300
75 | 100
60 | 110
6
1.6 AC
400 AC
3….30 DC
1 DC
7….16
3 DC
8.3
8.3
3000 AC
3000 AC
UR, CSA
-40…+125
-40…+100
4
35 (1.2)
1.0
Units
A
V
V/us
mA
A
mA
V
V
V
V
mA
V
ms
ms
V
V
°C
°C
°C/W
g (oz)
Nm
70S2-05-B
SPST-NO
Triac
4 | 6 | 10
24….140 AC
Zero Cross
300
75 | 100
60 | 110
6
1.6 AC
400 AC
6….30 DC
1 DC
6….10
3 DC
8.3
8.3
3000 AC
3000 AC
UR, CSA
-40…+125
-40…+100
4
35 (1.2)
1.0
Output Terminals
Input
Terminals
Panel
Mounting
(UL 508)
4/38
Magnecraft Solution Guide 105A
SECTION 4
Magnecraft Solution Guide 105A
70S2 M
70S2 F
www.magnecraft.com 847-441-2540
70S2-04-C
SPST-NO
Triac
4 | 6 | 10
24….280 AC
Zero Cross
300
75 | 100
60 | 110
6
1.6 AC
600 AC
3….30 DC
1 DC
7….16
3 DC
8.3
8.3
3000 AC
3000 AC
UR, CSA
-40…+125
-40…+100
4
35 (1.2)
1.0
70S2-05-C
SPST-NO
Triac
4 | 6 | 10
24….280 AC
Zero Cross
300
75 | 100
60 | 110
6
1.6 AC
600 AC
6….30 DC
1 DC
6….10
3 DC
8.3
8.3
3000 AC
3000 AC
UR, CSA
-40…+125
-40…+100
4
35 (1.2)
1.0
70S2-01-A
SPST-NO
MOSFET
3
3….60 DC
DC Switching
N/A
100
N/A
10 µ A
1.2 DC
105 DC
3….15 DC
1 DC
5….40
3 DC
75 µs
500 µs
2500 AC
2500 AC
UR, CSA
-40…+125
-40…+100
4
35 (1.2)
1.0
70S2-02-A
SPST-NO
MOSFET
3
3….60 DC
DC Switching
N/A
100
N/A
10 µ A
1.2 DC
105 DC
9….30 DC
1 DC
5….17
3 DC
75 µs
500 µs
2500 AC
2500 AC
UR, CSA
-40…+125
-40…+100
4
35 (1.2)
1.0
4/39
SECTION 4
Magnecraft Solution Guide 105A
Magnecraft Solution Guide 105A
0.2
(5.1)
1.2
(31.2)
0.4
(10.2)
0.3
(7.6)
0.6
(15.2)
0.5
(11.4)
0.3
(7.6)
0.2
(4.7)
POTTING MIGRATION ON LEADS
NOT TO EXCEED 0.025"
1
(26.2)
0.8
(20.7)
1.2
(31.7)
0.03 (0.76)
4 PLACES
0.2
(4.4)
1.2 MAX
(31.2)
1.9
(47.5)
2.2
(55.9)
1
(26.2)
0.9 MAX
(22.9)
0.4
(10.2)
0.6
(15.2)
0.2
(5.1)
0.3
(7.6)
0.5
(11.4)
0.3
(7.6)
0.3
(6.4)
INPUT
OUTPUT
0.03 (0.76)
4 PLACES
70S2 M
70S2 F
70S2 Series Solid State Relays/F and M Style continued
Output Terminals
Input
Terminals
Panel
Mounting
4/40
Magnecraft Solution Guide 105A
SECTION 4
Magnecraft Solution Guide 105A
Standard Part Numbers
Part Number Builder
70S2 M
70S2 F
70S2-04-B-04-F
70S2-05-B-04-F
70S2-04-C-04-F
70S2-05-C-04-F
70S2-01-A-03-F
70S2-02-A-03-F
70S2-04-B-06-M
70S2-05-B-06-M
70S2-04-B-10-M
70S2-05-B-10-M
70S2-04-C-06-M
70S2-05-C-06-M
70S2-04-C-10-M
70S2-05-C-10-M
3….30 VDC
6….30 VDC
3….30 VDC
6….30 VDC
3….15 VDC
9….30 VDC
3….30 VDC
6….30 VDC
3….30 VDC
6….30 VDC
3….30 VDC
6….30 VDC
3….30 VDC
6….30 VDC
24….140 VAC
24….140 VAC
24….280 VAC
24….280 VAC
3….60 VDC
3….60 VDC
24….140 VAC
24….140 VAC
24….140 VAC
24….140 VAC
24….280 VAC
24….280 VAC
24….280 VAC
24….280 VAC
SPST-NO
SPST-NO
SPST-NO
SPST-NO
SPST-NO
SPST-NO
SPST-NO
SPST-NO
SPST-NO
SPST-NO
SPST-NO
SPST-NO
SPST-NO
SPST-NO
Zero Cross
Zero Cross
Zero Cross
Zero Cross
DC Switching
DC Switching
Zero Cross
Zero Cross
Zero Cross
Zero Cross
Zero Cross
Zero Cross
Zero Cross
Zero Cross
4
4
4
4
3
3
6
6
10
10
6
6
10
10
BOLD-FACED PART NUMBERS ARE NORMALLY STOCKED
www.magnecraft.com 847-441-2540
Input Voltage
Range Output Voltage
Range Contact
Configuration Switching Type Rated Current
Load (Amps)
Series
70S2
Package Style
V = V STYLE
N = N STYLE
S = S STYLE
F = F STYLE
M = M STYLE
H = H STYLE
L = L STYLE
K = K STYLE
Input Voltage
01 = 3 to 15 VDC, DC/DC RELAYS
02 = 9 to 30 VDC, DC/DC RELAYS
03 = 3 to 30 VDC, 25 A S PACK
04 = 3 to 30 VDC (OR 32 VDC), DC/AC RELAYS
05 = 6 to 30 VDC (OR 32 VDC), DC/AC RELAYS
Output Voltage
A = 3 to 60 VDC
B = 24 to 140 VAC
C = 24 to 280 VAC
D = 8 to 50 VAC
Output Current
02 = 2.5 AMPS
03 = 3 AMPS
04 = 4 AMPS
05 = 5 AMPS
06 = 6 AMPS
10 = 10 AMPS
12 = 12 AMPS
25 = 25 AMPS
DC Operated
4/41
SECTION 4
Magnecraft Solution Guide 105A
Magnecraft Solution Guide 105A
General Specifications (@ 25° C)
Maximum Continuous Current vs. Ambient Temperature
7
8
6
5
4
3
2
1
STYLE L, 6A
STYLE H, 2.5A
25
20
15
10
5
STYLE S, 25A
STYLE N & S, 12A
STYLE N & S, 6A
UL Recognized
File No. E258297
70S2 Series Solid State Relays/H and L Style
On
Off
Terminals to Chassis
Input to Output
Standard version
Storage
Operation
Output Characteristics
Number and type of Contacts
Switching Device
Current Rating
Switching voltage
Switching Type
Maximum Rate of Rise Off State Voltage (dv/dt)
Min. Load current to maintain on
Non-Repetitive Surge Current (1 cycle)
Max. Off state leakage current (rms)
Typical On State Voltage Drop (rms)
Minimum Peak Blocking Voltage
Input Characteristics
Voltage Range
Must Release Voltage
Typical Input Current @ 5VDC or 240VAC
Max. Reverse Control Voltage
Performance Characteristics
Operating time (response time)
Dielectric strength
Environment
Product certifications
Ambient air temperature
around the device
Miscellaneous Characteristics
Thermal Resistance (Junction to Case)
Weight
Mounting Screw Torque
70S2-04-D
SPST-NO
Triac
2.5
8….50 AC
Zero Cross
300
75
60
3
1.6 AC
200 AC
3….30 DC
1 DC
1….17
3 DC
8.3
8.3
2500 AC
2500 AC
UR, CSA
-40…+125
-40…+100
3.5
22 (0.8)
1.0
Units
A
V
V/us
mA
A
mA
V
V
V
V
mA
V
ms
ms
V
V
°C
°C
°C/W
g (oz)
Nm
70S2-05-D
SPST-NO
Triac
2.5
8….50 AC
Zero Cross
300
75
60
3
1.6 AC
200 AC
6….30 DC
1 DC
1….6
3 DC
8.3
8.3
2500 AC
2500 AC
UR, CSA
-40…+125
-40…+100
3.5
22 (0.8)
1.0
Input Terminals
Output
Terminals
Panel
Mounting
(UL 508)
4/42
Magnecraft Solution Guide 105A
SECTION 4
Magnecraft Solution Guide 105A
70S2 L
70S2 H
www.magnecraft.com 847-441-2540
70S2-04-B
SPST-NO
Triac
2.5 | 6
24….140 AC
Zero Cross
300
75
60
6
1.6 AC
400 AC
3….30 DC
1 DC
1….17
3 DC
8.3
8.3
2500 AC
2500 AC
UR, CSA
-40…+125
-40…+100
3.5
22 (0.8)
1.0
70S2-05-B
SPST-NO
Triac
2.5 | 6
24….140 AC
Zero Cross
300
75
60
6
1.6 AC
400 AC
6….30 DC
1 DC
1….6
3 DC
8.3
8.3
2500 AC
2500 AC
UR, CSA
-40…+125
-40…+100
3.5
22 (0.8)
1.0
70S2-04-C
SPST-NO
Triac
2.5 | 6
24….280 AC
Zero Cross
300
75
60
6
1.6 AC
600 AC
3….30 DC
1 DC
1….17
3 DC
8.3
8.3
2500 AC
2500 AC
UR, CSA
-40…+125
-40…+100
3.5
22 (0.8)
1.0
70S2-05-C
SPST-NO
Triac
2.5 | 6
24….280 AC
Zero Cross
300
75
60
6
1.6 AC
400 AC
6….30 DC
1 DC
1….6
3 DC
8.3
8.3
2500 AC
2500 AC
UR, CSA
-40…+125
-40…+100
3.5
22 (0.8)
1.0
4/43
SECTION 4
Magnecraft Solution Guide 105A
Magnecraft Solution Guide 105A
1
(26.2)
0.2
(5.1)
1.2
0.3
(7.6)
0.5
(13.5)
0.6
(15.2)
0.5
(11.4)
0.4
(10.2)
0.3
(7.6)
0.03
(0.76)
0.2 (4.7) MIN
(31.2)
(+)
OUTPUT
INPUT
0.2
(4.4)
1.2 MAX
(31.2)
1.9
(47.5)
2.2
(55.9)
1
(26.2)
0.4
(10.2)
0.6
(15.2)
0.2
(5.1)
0.3
(7.6)
0.5
(11.4)
0.3
(7.6)
0.5 MAX
(13.5)
0.2 MIN.
(4.7)
0.03 (0.76)
SQUARE PINS
70S2 Series Solid State Relays/H and L Style continued
70S2 H
70S2 L
Input Terminals
Output
Terminals
Panel
Mounting
4/44
Magnecraft Solution Guide 105A
SECTION 4
Magnecraft Solution Guide 105A
70S2 L
70S2 H
Standard Part Numbers
Part Number Builder
70S2-04-D-02-H
70S2-05-D-02-H
70S2-04-B-02-H
70S2-05-B-02-H
70S2-04-C-02-H
70S2-05-C-02-H
70S2-04-B-06-L
70S2-05-B-06-L
70S2-04-C-06-L
70S2-05-C-06-L
3….30 VDC
6….30 VDC
3….30 VDC
6….30 VDC
3….30 VDC
6….30 VDC
3….30 VDC
6….30 VDC
3….30 VDC
6….30 VDC
8….50 VAC
8….50 VAC
24….140 VAC
24….140 VAC
24….280 VAC
24….280 VAC
24….140 VAC
24….140 VAC
24….280 VAC
24….280 VAC
SPST-NO
SPST-NO
SPST-NO
SPST-NO
SPST-NO
SPST-NO
SPST-NO
SPST-NO
SPST-NO
SPST-NO
Zero Cross
Zero Cross
Zero Cross
Zero Cross
Zero Cross
Zero Cross
Zero Cross
Zero Cross
Zero Cross
Zero Cross
2.5
2.5
2.5
2.5
2.5
2.5
6
6
6
6
BOLD-FACED PART NUMBERS ARE NORMALLY STOCKED
www.magnecraft.com 847-441-2540
Input Voltage
Range Output Voltage
Range Contact
Configuration Switching Type Rated Current
Load (Amps)
Series
70S2
Package Style
V = V STYLE
N = N STYLE
S = S STYLE
F = F STYLE
M = M STYLE
H = H STYLE
L = L STYLE
K = K STYLE
Input Voltage
01 = 3 to 15 VDC, DC/DC RELAYS
02 = 9 to 30 VDC, DC/DC RELAYS
03 = 3 to 30 VDC, 25 A S PACK
04 = 3 to 30 VDC (OR 32 VDC), DC/AC RELAYS
05 = 6 to 30 VDC (OR 32 VDC), DC/AC RELAYS
Output Voltage
A = 3 to 60 VDC
B = 24 to 140 VAC
C = 24 to 280 VAC
D = 8 to 50 VAC
Output Current
02 = 2.5 AMPS
03 = 3 AMPS
04 = 4 AMPS
05 = 5 AMPS
06 = 6 AMPS
10 = 10 AMPS
12 = 12 AMPS
25 = 25 AMPS
DC Operated
4/45
SECTION 4
Magnecraft Solution Guide 105A
Magnecraft Solution Guide 105A
General Specifications (@ 25° C)
Maximum Continuous Current vs. Ambient Temperature
7
8
6
5
4
3
2
1
STYLE L, 6A
STYLE H, 2.5A
7
8
6
5
4
3
2
1
Style K, 4 Amp
UL Recognized
File No. E258297
70S2 Series Solid State Relays/K Style
On
Off
Terminals to Chassis
Input to Output
Standard version
Storage
Operation
Output Characteristics
Number and type of Contacts
Switching Device
Current Rating
Switching voltage
Switching Type
Maximum Rate of Rise Off State Voltage (dv/dt)
Min. Load current to maintain on
Non-Repetitive Surge Current (1 cycle)
Max. Off state leakage current (rms)
Typical On State Voltage Drop (rms)
Minimum Peak Blocking Voltage
Input Characteristics
Voltage Range
Must Release Voltage
Typical Input Current @ 5VDC or 240VAC
Max. Reverse Control Voltage
Performance Characteristics
Operating time (response time)
Dielectric strength
Environment
Product certifications
Ambient air temperature
around the device
Miscellaneous Characteristics
Thermal Resistance (Junction to Case)
Weight
70S2-04-B
SPST-NO
Triac
4
24….140 AC
Zero Cross
300
75
60
6
1.6
400 AC
3….30 DC
1 DC
1….17
5 DC
8.3
8.3
3000 AC
3000 AC
UR, CSA
-40…+125
-40…+100
1.5
40 (1.4)
Units
A
V
V/us
mA
A
mA
V
V
V
V
mA
V
ms
ms
V
V
°C
°C
°C/W
g (oz)
70S2-04-C
SPST-NO
Triac
4
24….280 AC
Zero Cross
300
75
60
6
1.6
600 AC
3….30 DC
1 DC
1….6
5 DC
8.3
8.3
3000 AC
3000 AC
UR, CSA
-40…+125
-40…+100
1.5
40 (1.4)
Input Terminals
Output
Terminals
Socket
Compatible
(UL 508)
4/46
Magnecraft Solution Guide 105A
SECTION 4
Magnecraft Solution Guide 105A
70S2 K
70S2 K Relay with the
70-459-1 Socket
www.magnecraft.com 847-441-2540
70S2-04-D
SPST-NO
Triac
4
8….50 AC
Zero Cross
300
75
60
3
1.6
200 AC
3….30 DC
1 DC
1….17
5 DC
8.3
8.3
3000 AC
3000 AC
UR, CSA
-40…+125
-40…+100
1.5
40 (1.4)
70S2-05-B
SPST-NO
Triac
4
24….140 AC
Zero Cross
300
75
60
6
1.6
400 AC
6….30 DC
1 DC
1….6
5 DC
8.3
8.3
3000 AC
3000 AC
UR, CSA
-40…+125
-40…+100
1.5
40 (1.4)
70S2-05-C
SPST-NO
Triac
4
24….280 AC
Zero Cross
300
75
60
6
1.6
600 AC
6….30 DC
1 DC
1….17
5 DC
8.3
8.3
3000 AC
3000 AC
UR, CSA
-40…+125
-40…+100
1.5
40 (1.4)
70S2-05-D
SPST-NO
Triac
4
8….50 AC
Zero Cross
300
75
60
6
1.6
200 AC
6….30 DC
1 DC
1….6
5 DC
8.3
8.3
3000 AC
3000 AC
UR, CSA
-40…+125
-40…+100
1.5
40 (1.4)
70S2-01-A
SPST-NO
MOSFET
3
3….60 DC
DC Switching
N/A
100
7 (1 SEC)
10 µ A
1.2
105 DC
3….15
1 DC
5….40
5 DC
75 µs
500 µs
3000 AC
3000 AC
UR, CSA
-40…+125
-40…+100
1.5
40 (1.4)
70S2-02-A
SPST-NO
MOSFET
3
3….60 DC
DC Switching
N/A
100
7 (1 SEC)
10 µ A
1.2
105 DC
9….30
1 DC
5….17
5 DC
75 µs
500 µs
3000 AC
3000 AC
UR, CSA
-40…+125
-40…+100
1.5
40 (1.4)
4/47
SECTION 4
Magnecraft Solution Guide 105A
Magnecraft Solution Guide 105A
-
60VDC
3A
+
-VDC
9-30
0.187 (4.75)
4 PLACES
OUTPUT
INPUT
0.3 MIN.
(7.1)
1.3 MAX
(26.2)
0.9 MAX
(22.9)
1.2 MAX
(31.2)
0.6
(14.4)
0.2
(5.6)
0.1
(2.1)
0.2
(5.9)
0.3
(7.2)
0.3
(7.1)
0.02 (0.5)
4 PLACES
70S2 Series Solid State Relays/K Style continued
Input Terminals
Output
Terminals
Socket
Compatible
4/48
Magnecraft Solution Guide 105A
SECTION 4
Magnecraft Solution Guide 105A
70S2 K
70S2 K Relay with the
70-459-1 Socket
Standard Part Numbers
Part Number Builder
70S2-04-B-04-K
70S2-04-C-04-K
70S2-04-D-04-K
70S2-05-B-04-K
70S2-05-C-04-K
70S2-05-D-04-K
70S2-01-A-03-K
70S2-02-A-03-K
3….30 VDC
3….30 VDC
3….30 VDC
6….30 VDC
6….30 VDC
6….30 VDC
3….15 VDC
9….30 VDC
24….140 VAC
24….280 VAC
8….50 VAC
24….140 VAC
24….280 VAC
8….50 VAC
3….60 VDC
3….60 VDC
SPST-NO
SPST-NO
SPST-NO
SPST-NO
SPST-NO
SPST-NO
SPST-NO
SPST-NO
Zero Cross
Zero Cross
Zero Cross
Zero Cross
Zero Cross
Zero Cross
DC Switching
DC Switching
4
4
4
4
4
4
3
3
www.magnecraft.com 847-441-2540
Input Voltage
Range Output Voltage
Range Contact
Configuration Switching Type Rated Current
Load (Amps)
Series
70S2
Package Style
V = V STYLE
N = N STYLE
S = S STYLE
F = F STYLE
M = M STYLE
H = H STYLE
L = L STYLE
K = K STYLE
Input Voltage
01 = 3 to 15 VDC, DC/DC RELAYS
02 = 9 to 30 VDC, DC/DC RELAYS
03 = 3 to 30 VDC, 25 A S PACK
04 = 3 to 30 VDC (OR 32 VDC), DC/AC RELAYS
05 = 6 to 30 VDC (OR 32 VDC), DC/AC RELAYS
Output Voltage
A = 3 to 60 VDC
B = 24 to 140 VAC
C = 24 to 280 VAC
D = 8 to 50 VAC
Output Current
02 = 2.5 AMPS
03 = 3 AMPS
04 = 4 AMPS
05 = 5 AMPS
06 = 6 AMPS
10 = 10 AMPS
12 = 12 AMPS
25 = 25 AMPS
BOLD-FACED PART NUMBERS ARE NORMALLY STOCKED
DC Operated
4/49
Mouser Electronics
Authorized Distributor
Click to View Pricing, Inventory, Delivery & Lifecycle Information:
Schneider Electric:
70S2-04-B-12-S 70S2-04-B-04-F 70S2-04-D-03-V 70S2-01-A-03-V 70S2-01-A-05-S 70S2-02-A-05-S 70S2-01-A-
03F 70S2-04-C-06-N 70S2-03-C-25-S 70S2-04-B-03-V 70S2-04-B-06-S 70S2-04-B-06-N 70S2-04-C-03-V 70S2-
04-C-04-F 70S2-04-C-10-M 70S2-01-A-05-N 70S2-04-B-12-N 70S2-04-C-12-N 70S2-03-B-25-S 70S2-04-C-06-S
70S2-04-C-12-S 70S2-05-C-12-S 70S2-04-C-05-V 70S2-06-C-12-S 70S2-01-A-03-F