Special Features
Electrical Specs
120 Watts
AL60A
High efficiency - up to 86%
500 KHz fixed frequency
100°C baseplate operating
temperature (with no derating)
Low output ripple and noise
Excellent transient response
Safety isolated low voltage control and
monitoring
High reliability
Wide input voltage range
Parallelable with accurate current sharing
Adjustable output voltage and current limit
Regulation to zero load
Temperature monitor output
Operating temperature (baseplate):
-20°C to +85°C
Storage temperature: -40°C to +105°C
Overtemperature shutdown: 90°C typical
MTBF: > 1 million hours (50°C baseplate)
UL UL 1950 E182206 & E32002
CSA CSA22.2-234 LR53982C
CSA22.2-950
VDE IEC 950 20396-3336-1003 & 1009
EN 60950
CE CEMark (LVD)
Input
Input Range 180 to 400 VDC or 36 to 72 VDC
Efficiency 83% typical (5V @ 20A);
85% typical (12V @ 9A)
Output
Load Regulation 0.2% typical down to no load
Line Regulation 0.1% typical
Noise/Ripple 75 mV typical (output below 5V)
2% typical (output 5V and over)
Remote sense Up to 0.5V
Output Voltage
Adjust Range ±10% of nominal output
Transient Response 4% typical deviation with
250µs recovery (25-75% full load)
Current Share Accuracy 5% typical
Overvoltage Protection 125% nominal Vo
Current Limit 110% Io max
Control
Voltage Adjust 90 to 110% Vo
Enable TTL compatible (low to enable)
Clock Input
(external sync) 3.3 to 5.5Vp-p @ 1MHz ± 10%
Temperature
Monitor Output 10 mV/°K (2.73V = 0°C)
Current Monitor Output 0 to 1mA (1mA = 100% Io Rated)
Environmental
Total Power: 120 Watts
Input Voltages: 12V, 24V or 48V
No. of Outputs: Single, Dual
Safety
Astec Integrated Power
America’s (USA): 1-888-41-ASTEC Europe (UK): 44 (1384) 842-211 Asia (HK): 852-2437-9662
50
W9959_02_DCDC_001-073_73 2/8/02 3:38 PM Page 50
EUROPE
Astec House, Waterfront Business Park
Merry Hill, Dudley
West Midlands, DY5 1LX, UK
Telephone: 44 (1384) 842-211
Facsimile: 44 (1384) 843-355
AMERICAS
5810 Van Allen Way
Carlsbad, CA 92008
Telephone: 760-930-4600
Facsimile: 760-930-0698
Ordering Information
ASIA
Units 2111-2116, Level 21
Tower1, Metroplaza
223, Hing Fong Road
Fwai Fong, New Territories
Hong Kong
Telephone: 852-2437-9662
Facsimile: 852-2402-4426
Input Output Output Model Number Input Output Output Model Number
Voltage Voltage Current Voltage Voltage Current
300V 2.0V 20A AL60A-300L-020F20 48V 2.2V 30A AL60A-048L-022F30
300V 3.3V 25A AL60A-300L-033F25 48V 3.3V 25A AL60A-048L-033F25
300V 5V 20A AL60A-300L-050F20 48V 5V 10A AL60A-048L-050F10
300V 12V 9A AL60A-300L-120F09 48V 5V 20A AL60A-048L-050F20
300V 15V 8A AL60A-300L-150F08 48V 12V 6A AL60A-048L-120F06
300V 24V 3A AL60A-300L-240F03 48V 12V 9A AL60A-048L-120F09
48V 15V 8A AL60A-048L-150F08
Please contact Astec for information on other output voltages, power ranges and configurations.
Pin Assignments
Input Output Control Pins
31. +ve 22. +ve 1. +SENSE
32. –ve 23. +ve 2. TEMP MON
27. -ve 3. C MON
28. -ve 4. C SHARE
5. CLK IN
6. V ADJ
7. ENABLE
8. –SENSE
Secondary
side
controls
AL60A Astec Integrated Power
BASE PLATE*
(CONNECT TO PROTECTIVE EARTH)
2 INPUT PINS
¿1.52 (0.060)
±0.05 (0.002)
8 CONTROL PINS
¿0.64, 2.54 grid ±0.05
(¿0.025, 0.1 grid ±0.002)
6 OUTPUT PINS
¿1.52 (0.060)
±0.05 (0.002)
58.42 (2.30)
61.0 (2.40)
8
1
28
27
23
22
32
31
12.7
(0.50)
48.26 (1.900)
50.80 (2.000)
22.86 (0.900)
3.81
(0.150) typ
15.24
(0.600)
7.5 (0.30)
typ
5.1 (0.20)
typ
4.1 (0.16)
typ
Notes:
1. All dimensions in mm and (inches)
2. Baseplate must be connected to protective earth
3. General tolerance: .X ±0.5 (0.02)
.XX ±0.25 (0.010)
4. Surface Flatness: Concave 0.12mm max
Convex 0.38mm max
¿3.81 (0.150)
R3.8 (0.15)
typ
5
4
15.24
(0.600)
Load
+ SENSE
– SENSE
+ O/P
– O/P
36 to 72V
or
180 to 400V
+ I/P
– I/P
5
41
8
Output voltage adjust Enable (close to enable)
Temperature monitor output
Current monitor output
(e.g. to fan control circuit)
(e.g. to load indicator)
51
www.astec.com
W9959_02_DCDC_001-073_73 2/8/02 3:55 PM Page 51