Mar. 2002
φ3.5 ± 0.2 2.2 ± 0.2DEPTH
φ85 ± 0.2
+ 0
– 0.3
26 ± 0.5
φ120MAX
(φ127)
M3✕0.5 2.5DEPTH
0.4MIN 0.4MIN
(6.8)
φ134 ± 0.4
22.5° ± 0.5°
16-φ4.5+0.2
0
φ147 ± 0.4
φ85 ± 0.2
(4 )
A
A
A
kA
A2s
A/µs
V
V
A
A
kW
kW
W
W
°C
°C
kN
g
MITSUBISHI GATE COMMUTATED TURN-OFF THYRISTORS
FGC3500AX-120DS
HIGH POWER INVERTER USE
PRESS PACK TYPE
FGC3500AX-120DS OUTLINE DRAWING Dimensions in mm
3500
1800
1200
25
2.6 × 106
1000
10
21
1000
3500
10
120
200
630
–20 ~ +125
–20 ~ +150
32 ~ 48
1500
Repetitive controllable on-state current
RMS on-state current
Average on-state current
Surge on-state current
Current-squared, time integration
Critical rate of rise of on-state current
Peak forward gate voltage
Peak reverse gate voltage
Peak forward gate current
Peak reverse gate current
Peak forward gate power dissipation
Peak reverse gate power dissipation
Average forward gate power dissipation
Average reverse gate power dissipation
Junction temperature
Storage temperature
Mounting force required
Weight
APPLICATION
Inverters, DC choppers, Induction heaters, DC to DC converters.
Symbol Parameter Conditions Ratings Unit
ITQRM
IT(RMS)
IT(AV)
ITSM
I2t
diT/dt
VFGM
VRGM
IFGM
IRGM
PFGM
PRGM
PFG(AV)
PRG(AV)
Tj
Tstg—
—
VDM = 6000V, VD = 3600V, VRG = 20V
diGQ/dt = 6000A/µs, Tj = 25/125°C
CC = 6µF, LC = 0.3µH (see Fig. 1, 3)
Applied for all conduction angles
f = 60Hz, sinewave θ = 180°, Tf = 70°C
One half cycle at 60Hz, Tj = 125°C
VD = 3600V, IT = 3500A, IGM= 200A, Tj= 25/125°C
diG/dt = 100A/µs (see Fig. 1, 2)
(Recommended value 40kN)
Typical value
21
21
6000
6000
3600
VRRM
VRSM
VDRM
VDSM
VLTDS
UnitSymbol Parameter V
V
V
V
V
Voltage class
Repetitive peak reverse voltage
Non-repetitive peak reverse voltage
Repetitive peak off-state voltage
Non-repetitive peak off-state voltage
Long term DC stability voltage
MAXIMUM RATINGS
PRELIMINARY
Notice: This is not a final specification.
Some parametric limits are subject to change.
●Asymmetrical GCT
●ITQRM
Repetitive controllable on-state current
.......... 3500A
●IT(AV) Average on-state current.................... 1200A
●VDRM
Repetitive peak off-state voltage
.................. 6000V
●VRRM
Repetitive peak reverse voltage
....................... 21V
Conditions
—
—
VGK = –2V
VGK = –2V
VGK = –2V, λ = 100 Fit