EMC and Power Quality
The FN 9280 power entry module combines
an IEC inlet, a mains filter and a dual fuse
holder with a 2-pole rocker switch in an ultra
compact housing.
Choosing FN 9280/90 product line brings you
the rapid availability of a standard filter asso-
ciated with the necessary safety acceptances
and a high attenuation performance. For
higher attenuation performance the FN 9290
family with a dual stage filter and identical
panel cut-out can be used.
Standard IEC connector filters are a practi-
cal solution to pass EMI system approval in
a short time. A wide selection of amperage
ratings, mounting possibilities and also filters
for medical applications are designed to offer
you the best solution.
Features and benefits
I Good conducted attenuation performance,
based on chokes with high saturation resi-
stance and excellent thermal behavior
I Deep-drawn iron-sheet housing for best
possible shielding against magnetic fields
I Rear/front flange mounting or snap-in
versions
I Dual fuse holder
I 2-pole rocker switch
I Faston or spring cage terminals for more
flexible assembly
I Medical version (B Type) according IEC /
EN60601-1
I Spare fuse holder
Typical applications
I Portable electrical and electronic
equipment
I Consumer goods
I EDP and office equipment
I Single-phase power supplies, switch-mode
power supplies
I Test and measurement equipment
I Medical electrical devices (MD) and
In-Vitro
-Diagnostics (IVD) equipment
IEC Inlet Filters
FN 9280 & FN 9290 Series
Ultra Compact and Versatile Filtered
Power Entry Module
I Single stage filter FN 9280
I Dual stage filter FN 9290
I Ultra compact design
I Rated currents up to 10A
I Dual fuse holder
I 2-pole rocker switch
I Good attenuation performance
I Faston or spring cage terminals
Technical specifications
Maximum continuous operating voltage: 250 VAC, 50/60 Hz
Operating frequency: 50 to 400 Hz
Rated currents: 1 to 10A* @ 40°C
High potential test voltage: P –> PE 2000 VAC for 2 sec (standard types)
P –> PE 2500 VAC for 2 sec (B types)
P –> N 760 VAC for 2 sec
Leakage current: Standard: <500uA at 250 VAC/50 Hz
Medical: <5uA at 250 VAC/50 Hz
Protection category: IP40 according to IEC 60529 (front side)
Terminals: IP20 spring cage safe against finger touch
Spring cage wire range: 0.2 –1.5 mm2 / 24 –16 AWG single or flexible wire
Temperature range (operation and storage): 25°C to +85°C (25/85/21)
Design corresponding to: UL 1283, CSA 22.2 No. 8 1986, EN60939, EN60950,
EN60601-1, UL544, EN60320
Flammability corresponding to: UL 94V-2 or better
MTBF @ 40°C/230V (Mil-HB-217F): > 1,000,000 hours
Fuse holder: 2 fuses (Ø5 x 20mm) max. 250V
Rocker switch: 2-pole, dark not illuminated, Marking I - 0
Electrical specifications: Inrush current 82A
6,000 on-off operations according to UL 1054
10,000 on-off operations according to ENEC
Mechanical life: 50,000 cycles
Switch ratings: USA (UL) and Canada (C-UL) 10A, 125VAC; 10A, 250VAC; 1/3HP
Europe (ENEC) 10A (4A), 250VAC**
Approvals
(CQC, approval pending)
* 10A version is 8A UL approved
** Value in () relates to the inductive current charge: cos γ = 0.65
Typical electrical schematic
FN 9280 E types (B types without Cy)
FN 9290 Standard types (B types without Cy)
FN 9280 Standard types (B types without Cy)
Fuse holder
included
EMC components > FN 9280/FN 92902
Filter* Rated current Leakage current** Inductance Capacitance Resistance Output Weight
@ 40°C @ 250V ~/50Hz L1 L2 Cx Cy R connections
[A] [uA] [mH] [nF] [kOhm] [g]
FN 9280 Series
Filter selection table
FN 9280-1-.. 1 311 10.9 0 220 2.2 1000 -06 -100 101
FN 9280-2-.. 2 311 4.4 0 220 2.2 1000 -06 -100 102
FN 9280-4-.. 4 311 1.7 0 220 2.2 1000 -06 -100 105
FN 9280-6-.. 6 311 0.78 0 220 2.2 1000 -06 -100 104
FN 9280-10-.. 10 311 0.32 0 220 2.2 1000 -06 -100 106
FN 9280B-1-.. 1 2 10.9 0 220 0 1000 -06 -100 101
FN 9280B-2-.. 2 2 4.4 0 220 0 1000 -06 -100 102
FN 9280B-4-.. 4 2 1.7 0 220 0 1000 -06 -100 105
FN 9280B-6-.. 6 2 0.78 0 220 0 1000 -06 -100 104
FN 9280B-10-.. 10 2 0.32 0 220 0 1000 -06 -100 106
FN 9289-1-.. 1 311 10.9 0 220 2.2 1000 -06 -100 101
FN 9289-2-.. 2 311 4.4 0 220 2.2 1000 -06 -100 102
FN 9289-4-.. 4 311 1.7 0 220 2.2 1000 -06 -100 105
FN 9289-6-.. 6 311 0.78 0 220 2.2 1000 -06 -100 104
FN 9289-10-.. 10 311 0.32 0 220 2.2 1000 -06 -100 106
FN 9289B-1-.. 1 2 10.9 0 220 0 1000 -06 -100 101
FN 9289B-2-.. 2 2 4.4 0 220 0 1000 -06 -100 102
FN 9289B-4-.. 4 2 1.7 0 220 0 1000 -06 -100 105
FN 9289B-6-.. 6 2 0.78 0 220 0 1000 -06 -100 104
FN 9289B-10-.. 10 2 0.32 0 220 0 1000 -06 -100 106
FN 9280E-1-.. 1 311 10.9 0.4 220 2.2 1000 -06 -100 135
FN 9280E-2-.. 2 311 4.4 0.4 220 2.2 1000 -06 -100 136
FN 9280E-4-.. 4 311 1.66 0.4 220 2.2 1000 -06 -100 137
FN 9280E-6-.. 6 311 0.78 0.4 220 2.2 1000 -06 -100 138
FN 9280E-10-.. 10 311 0.32 0.4 220 2.2 1000 -06 -100 139
FN 9280BE-1-.. 1 2 10.9 0.4 220 0 1000 -06 -100 135
FN 9280BE-2-.. 2 2 4.4 0.4 220 0 1000 -06 -100 136
FN 9280BE-4-.. 4 2 1.66 0.4 220 0 1000 -06 -100 137
FN 9280BE-6-.. 6 2 0.78 0.4 220 0 1000 -06 -100 138
FN 9280BE-10-.. 10 2 0.32 0.4 220 0 1000 -06 -100 139
FN 9289E-1-.. 1 311 10.9 0.4 220 2.2 1000 -06 -100 135
FN 9289E-2-.. 2 311 4.4 0.4 220 2.2 1000 -06 -100 136
FN 9289E-4-.. 4 311 1.66 0.4 220 2.2 1000 -06 -100 137
FN 9289E-6-.. 6 311 0.78 0.4 220 2.2 1000 -06 -100 138
FN 9289E-10-.. 10 311 0.32 0.4 220 2.2 1000 -06 -100 139
FN 9289BE-1-.. 1 2 10.9 0.4 220 0 1000 -06 -100 135
FN 9289BE-2-.. 2 2 4.4 0.4 220 0 1000 -06 -100 136
FN 9289BE-4-.. 4 2 1.66 0.4 220 0 1000 -06 -100 137
FN 9289BE-6-.. 6 2 0.78 0.4 220 0 1000 -06 -100 138
FN 9289BE-10-.. 10 2 0.32 0.4 220 0 1000 -06 -100 139
* To compile a complete part number, please replace the -.. with the required output connection style (e.g. FN 9289-1-06, FN 9282-4-100
** Maximum leakage current under normal conditions according to IEC 60939-1 Ed. 3 at 250V AC.
EMC components > FN 9280/FN 92903
Filter* Rated current Leakage current** Inductance Capacitance Resistance Output Weight
@ 40°C @ 250V ~/50Hz L1 L2 Cx Cy1 Cy2 R connections
[A] [uA] [mH] [nF] [kOhm] [g]
FN 9290 Series
Filter selection table
FN 9290-1-.. 1 311 10.9 10.9 220 1.5 0.47 1000 -06 -100 147
FN 9290-2-.. 2 311 4.4 4.4 220 1.5 0.47 1000 -06 -100 148
FN 9290-4-.. 4 311 1.7 1.7 220 1.5 0.47 1000 -06 -100 148
FN 9290-6-.. 6 311 0.78 0.78 220 1.5 0.47 1000 -06 -100 153
FN 9290-10-.. 10 311 0.32 0.32 220 1.5 0.47 1000 -06 -100 154
FN 9290B-1-.. 1 2 10.9 10.9 220 0 0 1000 -06 -100 147
FN 9290B-2-.. 2 2 4.4 4.4 220 0 0 1000 -06 -100 148
FN 9290B-4-.. 4 2 1.7 1.7 220 0 0 1000 -06 -100 148
FN 9290B-6-.. 6 2 0.78 0.78 220 0 0 1000 -06 -100 153
FN 9290B-10-.. 10 2 0.32 0.32 220 0 0 1000 -06 -100 154
FN 9299-1-.. 1 311 10.9 10.9 220 1.5 0.47 1000 -06 -100 147
FN 9299-2-.. 2 311 4.4 4.4 220 1.5 0.47 1000 -06 -100 148
FN 9299-4-.. 4 311 1.7 1.7 220 1.5 0.47 1000 -06 -100 148
FN 9299-6-.. 6 311 0.78 0.78 220 1.5 0.47 1000 -06 -100 153
FN 9299-10-.. 10 311 0.32 0.32 220 1.5 0.47 1000 -06 -100 154
FN 9299B-1-.. 1 2 10.9 10.9 220 0 0 1000 -06 -100 147
FN 9299B-2-.. 2 2 4.4 4.4 220 0 0 1000 -06 -100 148
FN 9299B-4-.. 4 2 1.7 1.7 220 0 0 1000 -06 -100 148
FN 9299B-6-.. 6 2 0.78 0.78 220 0 0 1000 -06 -100 153
FN 9299B-10-.. 10 2 0.32 0.32 220 0 0 1000 -06 -100 154
Product selector:
FN 92vww-xx-yy-zz
Blank: Snap in range 1.0 to 2.5 mm
Optional: 30: Snap in range >2.5 to 3.5 mm
06: Fast-On 6.3 x 0.8 mm (spade/soldering)
100: Spring cage
1 to 10: Rated current [A]
Blank: Standard version
B: Medical version (without Y2-capacitor)
Optional: E: Earth line choke
BE: Medical version (without YZ-capacitor) with earth line choke
0: Flange version vertical/horizontal/front/rear mounting set
9: Snap-in version, snapper on horizontal side (top / bottom)
Optional: 1: Rear Flange mounting (top / bottom)
2: Front Flange mounting (top / bottom)
3: Rear Flange mounting (left / right)
4: Front Flange mounting (left / right)
8: Snap-in version, snapper on vertical side (left / right)
8: Single stage filter
9: Dual stage filter
All FN 9280/FN 9290 are equipped with a dual fuse holder with a spare fuse holder.
Note: All FN 9280/FN 9280B/FN 9289/FN 9289B/FN 9290/FN 9290B/FN 9299/FN 9299B are stock types from our distribution partners.
Order Examples:
FN 9280B-6-100: Medical version of single stage, dual fuse EMC/EMI filter, flange set for vertical/horizontal/front/rear mounting, 6A, spring cage
t erminals, from stock available.
FN 9298-6-06-30: Dual stage, dual fuse EMC/EMI filter, snap-in version, snappers for snap-in panel thickness range >2.5 to 3.5 mm, snapper on
vertical side, 6A, fast-on terminals, non-stock order type
* To compile a complete part number, please replace the -.. with the required output connection style (e.g. FN 9289-1-06, FN 9282-4-100
** Maximum leakage current under normal conditions according to IEC 60939-1 Ed. 3 at 250V AC.
EMC components > FN 9280/FN 92904
FN 9280BE Series | Typical filter attenuation | Per CISPR 17; A = 50Ω/50Ω sym; B = 50Ω/50Ω asym
1A types 2A types 10A types4 – 6A types
A
B
FN 9280B Series | Typical filter attenuation | Per CISPR 17; A = 50Ω/50Ω sym; B = 50Ω/50Ω asym
1A types 2A types 10A types
4 – 6A types
A
B
FN 9280E Series | Typical filter attenuation | Per CISPR 17; A = 50Ω/50Ω sym; B = 50Ω/50Ω asym
1A types 2A types 10A types
4 – 6A types
6A
B
FN 9280 Series | Typical filter attenuation | Per CISPR 17; A = 50Ω/50Ω sym; B = 50Ω/50Ω asym
1A types 2A types 10A types
4 – 6A types
A
B
EMC components > FN 9280/FN 92905
FN 9290B Series | Typical filter attenuation | Per CISPR 17; A = 50Ω/50Ω sym; B = 50Ω/50Ω asym
FN 9290 Series | Typical filter attenuation | Per CISPR 17; A = 50Ω/50Ω sym; B = 50Ω/50Ω asym
1A types
1A types
2A types
2A types
10A types
10A types
4 – 6A types
4 – 6A types
A
B
B
A
EMC components > FN 9280/FN 92906
Mechanical Data:
FN 9280-x-06 / FN 9280B-x-06: FN 9280-X-100 / FN 9280B-X-100: Dimensions (mm)
FN 9283 / FN 9284 FN 9281 / FN 9282
assembly instructions
see on last page
FN 9289-x-06 / FN 9289B-x-06: FN 9289-x-100 / FN 9289B-x-100: Dimensions (mm)
Panel cutout: Panel cutout:
EMC components > FN 9280/FN 92907
FN 9299-x-06 / FN 9299B-x-06 / FN 9289E-x-06 / FN 9889BE-x-06: FN 9299-x-100 / FN 9299B-x-100 / FN 9289E-x-100 / FN 9289BE-x-100:
FN 9293 / FN 9294 FN 9291 / FN 9292
FN 9290-x-06 / FN 9290B-x-06 / FN 9280E-x-06 / FN 9280BE-x-06: FN 9290-x-100 / FN 9290B-x-100 / FN 9280E-x-100 / FN 9280BE-x-100:
Dimensions (mm)
assembly instructions
see on last page
Panel cutout: Panel cutout:
Dimensions (mm)
EMC components > FN 9280/FN 92908
Assembly Instructions:
Terminal -100
clamping range, solid wire / flex wire 0,20 mm² –1,5 mm², AWG24 – AWG16
operating force of slider max. 40N
recommended stripped length 8mm
Your local partner: To find your local partner within Schaffner’s global network, please go to www.schaffner.com
Recommended screw:
Panhead tapping screw d x l 3,9 x 9,5 mm
Recommended screw:
Countersunk screw M3X14 DIN963A
or M3
or M3
Removal of the combined switch / fuse holder unit
An additional fuse mark on the switch indicates
the fuses holders behind the switch. The red
frame shows the outline of the removable unit.
With a simple tool like a Swiss Army knife or a
screwdriver No 1 or smaller the unit (1) can be
removed from the filter. On the topside (2) behind
the switch there are two fuse holders for each
live connection. On the bottom side (3) is a clip to
carry an additional spare fuse.
REAR MOUNTING FRONT MOUNTING
Fuses are not in the scope of delivery.
Push the knob above the
terminal to insert the wire.
10/2012 EN
Headquarters, global innovation
and development center
Schaffner Group
Nordstrasse 11
4542 Luterbach
Switzerland
T +41 32 681 66 26
F +41 32 681 66 30
info@schaffner.com
www.schaffner.com
Sales and application centers
China
Schaffner EMC Ltd. Shanghai
T20-3, No 565 Chuangye Road
Pudong New Area
Shanghai 201201
T +86 21 3813 9500
F +86 21 3813 9501 / 02
cschina@schaffner.com
www.schaffner.com
Finland
Schaffner Oy
Sauvonrinne 19 H
08500 Lohja
T +358 19 35 72 71
F +358 19 32 66 10
finlandsales@schaffner.com
France
Schaffner EMC S.A.S.
112, Quai de Bezons
95103 Argenteuil
T +33 1 34 34 30 60
F +33 1 39 47 02 28
francesales@schaffner.com
Germany
Schaffner Deutschland GmbH
Schoemperlenstrasse 12B
76185 Karlsruhe
T +49 721 56910
F +49 721 569110
germanysales@schaffner.com
Italy
Schaffner EMC S.r.l.
Via Galileo Galilei, 47
20092 Cinisello Balsamo (MI)
T +39 02 66 04 30 45/47
F +39 02 61 23 943
italysales@schaffner.com
Japan
Schaffner EMC K.K.
Mitsui-Seimei Sangenjaya Bldg. 7F
1-32-12, Kamiuma, Setagaya-ku
Tokyo 154-0011
T +81 3 5712 3650
F +81 3 5712 3651
japansales@schaffner.com
www.schaffner.jp
Singapore
Schaffner EMC Pte Ltd.
Blk 3015A Ubi Road 1
05-09 Kampong Ubi Industrial Estate
T +65 6377 3283
F +65 6377 3281
singaporesales@schaffner.com
Spain
Schaffner EMC España
Calle Caléndula 93
Miniparc III, Edificio E
El Soto de la Moraleja
Alcobendas
28109 Madrid
T +34 618 176 133
spainsales@schaffner.com
Sweden
Schaffner EMC AB
Turebergstorg 1, 6
19147 Sollentuna
T +46 8 5792 1121 / 22
F +46 8 92 96 90
swedensales@schaffner.com
Switzerland
Schaffner EMV AG
Nordstrasse 11
4542 Luterbach
T +41 32 681 66 26
F +41 32 681 66 41
sales@schaffner.ch
Taiwan
Schaffner EMV Ltd.
6th Floor, No 413
Rui Guang Road
Neihu District
Taipei City 114
T +886 2 87525050
F +886 2 87518086
taiwansales@schaffner.com
Thailand
Schaffner EMC Co. Ltd.
Northern Region Industrial Estate
67 Moo 4 Tambon Ban Klang
Amphur Muang P.O. Box 14
Lamphun 51000
T +66 53 58 11 04
F +66 53 58 10 19
thailandsales@schaffner.com
UK
Schaffner Ltd.
5 Ashville Way
Molly Millars Lane
Wokingham
Berkshire RG41 2PL
T +44 118 9770070
F +44 118 9792969
uksales@schaffner.com
www.schaffner.uk.com
USA
Schaffner EMC Inc.
52 Mayfield Avenue
Edison, New Jersey 08837
T +1 732 225 9533
F +1 732 225 4789
usasales@schaffner.com
www.schaffner.com/us
To find your local partner within
Schaffner‘s global network, please go to
www.schaffner.com
© 2012 Schaffner Group
Specifications are subject to change
within notice. The latest version of the
data sheets can be obtained from the
website. All trademarks recognized.
Schaffner is an ISO-registered company.
Its products are designed and
manufactured under the strict quality
and environnmental requirements of
the ISO 9001 and ISO 14001 standards.
This document has been carefully
checked. However, Schaffner does not
assume any liability for errors or
inaccuracies.