DC/DC Railway Converter TEP 200WIRCMF Series, 200 Watt * Chassis mount with screw terminal block * Including EMI filter to meet EN 55032, class A * Ultra wide 4:1 input voltage ranges 9-36, 18-75, 43-160 VDC * EN 50155 approval for railway applications * * * * * * Very high efficiency up to 91% No minimum load UL 62368-1 IEC 62368-1 Soft start Under voltage lock-out circuit Adjustable output voltage +10 / -20% Sense line The TEP 200WIRCMF Series is a family of isolated high performance DC/DC converter modules with ultra-wide 4:1 input voltage ranges. They come in chassis mount version with screw terminal block and with integrated EMI input filter to meet EN 55032 class A. A very high efficiency allows full power operation at 25C with only 100 LFM air flow cooling and operation at 60C with only 40% power derating. The very wide input voltage range and reverse input voltage protection make these converters interesting solution for battery operated systems. Typical applications are in telecom/datacom, industry control and railway systems for onboard power distribution. Models Order Code Input Voltage Range Output Voltage nom. Output Current max. Efficiency typ. 12 VDC 15'000 mA 89 % 15 VDC 12'000 mA 90 % 24 VDC 7'500 mA 90 % TEP 200-2416WIRCMF 28 VDC 6'500 mA 90 % TEP 200-2418WIRCMF 48 VDC 3'700 mA 89 % TEP 200-4812WIRCMF 12 VDC 18'000 mA 90 % 15 VDC 14'000 mA 91 % 24 VDC 9'000 mA 90 % TEP 200-4816WIRCMF 28 VDC 7'500 mA 91 % TEP 200-4818WIRCMF 48 VDC 4'500 mA 90 % TEP 200-7212WIRCMF 12 VDC 20'000 mA 89 % 15 VDC 16'000 mA 90 % 24 VDC 10'000 mA 89 % TEP 200-7216WIRCMF 28 VDC 8'500 mA 90 % TEP 200-7218WIRCMF 48 VDC 5'000 mA 89 % TEP 200-2412WIRCMF TEP 200-2413WIRCMF TEP 200-2415WIRCMF TEP 200-4813WIRCMF TEP 200-4815WIRCMF TEP 200-7213WIRCMF TEP 200-7215WIRCMF www.tracopower.com 9 - 36 VDC (24 VDC nom.) 18 - 75 VDC (48 VDC nom.) 43 - 160 VDC (110 VDC nom.) March 17, 2021 Page 1 / 5 TEP 200WIRCMF Series, 200 Watt Options TEP-MK1 - Optional DIN-Rail Mounting Kit: www.tracopower.com/products/tep-mk1.pdf - Optional model with 3.3 VDC / 50'000 mA Output and 9 - 36 VDC Input - Optional model with 5 VDC / 36'000 mA Output and 9 - 36 VDC Input - Optional model with 3.3 VDC / 50'000 mA Output and 18 - 75 VDC Input - Optional model with 5 VDC / 40'000 mA Output and 18 - 75 VDC Input on demand - Optional model with 53 VDC / 3'800 mA Output and 33 - 75 VDC Input (backorder with MOQ non stocking item) - Optional model with 3.3 VDC / 57'000 mA Output and 43 - 160 VDC Input - Optional model with 5 VDC / 44'000 mA Output and 43 - 160 VDC Input - 2:1 Input models - Chassis mount models without filter: www.tracopower.com/products/tep200wircm.pdf - Negative (passive = Off) Remote On/Off function Input Specifications Input Current - At no load 24 Vin models: 48 Vin models: 110 Vin models: 24 Vin models: 48 Vin models: 110 Vin models: 24 Vin models: 48 Vin models: 110 Vin models: 24 Vin models: 48 Vin models: 110 Vin models: Surge Voltage Under Voltage Lockout Recommended Input Fuse Input Filter 35 mA typ. 20 mA typ. 10 mA typ. 50 VDC max. (1 s max.) 100 VDC max. (1 s max.) 185 VDC max. (1 s max.) 7.3 VDC min. / 7.7 VDC typ. / 8.1 VDC max. 15.5 VDC min. / 16 VDC typ. / 16.3 VDC max. 33 VDC min. / 34.5 VDC typ. / 36 VDC max. 32'000 mA (fast acting) 20'000 mA (fast acting) 10'000 mA (fast acting) (The need of an external fuse has to be assessed in the final application.) Internal Pi-Type Output Specifications Output Voltage Adjustment Voltage Set Accuracy Regulation Ripple and Noise (20 MHz Bandwidth) - Input Variation (Vmin - Vmax) - Load Variation (0 - 100%) -20% to +10% (By external trim resistor) See application note: www.tracopower.com/overview/tep200wircmf Output power must not exceed rated power! 1% max. 0.1% max. 0.1% max. 3.3 Vout models: 75 mVp-p max. (w/ 1 F X7R // 25 F poscap) 5 Vout models: 75 mVp-p max. (w/ 1 F X7R // 25 F poscap) 12 Vout models: 100 mVp-p max. (w/ 1 F X7R // 25 F poscap) 15 Vout models: 100 mVp-p max. (w/ 1 F X7R // 25 F poscap) 24 Vout models: 200 mVp-p max. (w/ 4.7 F X7R) 28 Vout models: 200 mVp-p max. (w/ 4.7 F X7R) 48 Vout models: 300 mVp-p max. (w/ 2.2 F X7R) All specifications valid at nominal voltage, full load and +25C after warm-up time unless otherwise stated. www.tracopower.com March 17, 2021 Page 2 / 5 TEP 200WIRCMF Series, 200 Watt Capacitive Load - 24 Vin input - 48 Vin input - 110 Vin input Minimum Load Temperature Coefficient Start-up Time Short Circuit Protection Output Current Limitation Overvoltage Protection Transient Response 3.3 Vout models: 5 Vout models: 12 Vout models: 15 Vout models: 24 Vout models: 28 Vout models: 48 Vout models: 3.3 Vout models: 5 Vout models: 12 Vout models: 15 Vout models: 24 Vout models: 28 Vout models: 48 Vout models: 3.3 Vout models: 5 Vout models: 12 Vout models: 15 Vout models: 24 Vout models: 28 Vout models: 48 Vout models: - Response Time 151'000 F max. 72'000 F max. 12'500 F max. 8'000 F max. 3'100 F max. 2'300 F max. 770 F max. 151'000 F max. 80'000 F max. 15'000 F max. 9'300 F max. 3'700 F max. 2'600 F max. 930 F max. 172'000 F max. 88'000 F max. 16'600 F max. 10'600 F max. 4'100 F max. 3'000 F max. 1'000 F max. Not required 0.02 %/K max. 75 ms typ. Continuous, Automatic recovery 120 - 150% of Iout max. 115 - 130% of Vout nom. 200 s typ. / 250 s max. (25% Load Step) Safety Specifications Safety Standards EN 60950-1 EN 62368-1 IEC 60950-1 IEC 62368-1 UL 60950-1 UL 62368-1 EN 50155 - IT / Multimedia Equipment - Railway Applications - Certification Documents www.tracopower.com/overview/tep200wircmf Pollution Degree Over Voltage Category PD 2 OVC II EMC Specifications EMI Emissions EN 55011 class A (internal filter) EN 55032 class A (internal filter) EN 55011 class A (internal filter) EN 55032 class A (internal filter) - Conducted Emissions - Radiated Emissions All specifications valid at nominal voltage, full load and +25C after warm-up time unless otherwise stated. www.tracopower.com March 17, 2021 Page 3 / 5 TEP 200WIRCMF Series, 200 Watt EMS Immunity - Electrostatic Discharge Air: Contact: - RF Electromagnetic Field - EFT (Burst) / Surge Ext. input component: - Conducted RF Disturbances - PF Magnetic Field Continuous: 1 s: EN 50155 (Railway Applications) EN 50121-3-2 (EMC for Rolling Stock) EN 61000-4-2, 8 kV, perf. criteria A EN 61000-4-2, 6 kV, perf. criteria A EN 61000-4-3, 20 V/m, perf. criteria A EN 61000-4-4, 2 kV, perf. criteria A EN 61000-4-5, 2 kV, perf. criteria A 24 & 48 Vin models: 2 x KY 220 F 110 Vin models: 2 x KXJ 150 F EN 61000-4-6, 10 Vrms, perf. criteria A EN 61000-4-8, 100 A/m, perf. criteria A EN 61000-4-8, 1000 A/m, perf. criteria A General Specifications Relative Humidity Temperature Ranges Power Derating Over Temperature Protection Switch Off 95% max. (non condensing) -40C to +75C +105C max. -40C to +105C - Operating Temperature - Case Temperature - Storage Temperature - High Temperature - Protection Mode - Measurement Point Cooling System Sense Function Remote Control - Voltage Controlled Remote - Off Idle Input Current - Remote Pin Input Current Altitude During Operation Switching Frequency Insulation System Working Voltage (rated) Isolation Test Voltage - Input to Output, 60 s - Input to Case, 60 s - Output to Case, 60 s Isolation Resistance Isolation Capacitance Reliability Environment - Input to Output, 500 VDC - Input to Output, 100 kHz, 1 V - Calculated MTBF - Vibration - Mechanical Shock - Thermal Shock Housing Material See application note: www.tracopower.com/overview/tep200wircmf 115C typ. (Automatic recovery at 105C typ.) Base-Plate Natural convection (20 LFM) 10% max. of Vout nom. (Sense line to be connected to the output either at the module or at the load under regard of polarity.) On: 3.0 to 12 VDC or open circuit Off: 0 to 1.2 VDC or short circuit Refers to 'Remote' and '-Vin' Pin 3 mA typ. -0.5 to 1.0 mA 2'000 m max. (for reinforced insulation) 5'000 m max. (for functional insulation)) 225 - 275 kHz (PWM) 250 kHz typ. (PWM) Reinforced Insulation (110 Vin models only) Functional Insulation (other models) 145 VAC (3.3 and 5 Vout models) 185 VAC (48 and 53 Vout models) 172 VAC (other output models) 3'000 VAC (110 Vin models) 3'000 VDC (other models) 1'500 VAC (110 Vin models) 1'600 VDC (other models) 1'500 VAC (110 Vin models) 1'600 VDC (other models) 1'000 M min. 2'500 pF max. 300'000 h (MIL-HDBK-217F, ground benign) MIL-STD-810F EN 61373 MIL-STD-810F EN 61373 MIL-STD-810F EN 50155 Alu base-plate w. plastic case (110 Vin models) Alu base-plate w. metal case (other models) All specifications valid at nominal voltage, full load and +25C after warm-up time unless otherwise stated. www.tracopower.com March 17, 2021 Page 4 / 5 TEP 200WIRCMF Series, 200 Watt Base Material Non-conductive FR4 (UL94 V-0 rated) (24 Vin & 48 Vin models only) Silicone (UL 94 V-0 rated) Screw Terminal 287 g Potting Material Connection Type Weight Thermal Impedance Environmental Compliance - REACH Declaration 6.1 K/W www.tracopower.com/info/reach-declaration.pdf REACH SVHC list compliant REACH Annex XVII compliant www.tracopower.com/info/rohs-declaration.pdf - RoHS Declaration Exemptions: 7a, 7c-I www.tracopower.com/info/en45545-declaration.pdf - Flammability (EN 45545-2) Supporting Documents Overview Link (for additional Documents) www.tracopower.com/overview/tep200wircmf 10.0 (0.39) 3.0 (0.12) Outline Dimensions 85.0 (3.35) Pinout 19.3 (0.76) 57.9 (2.28) Pin Function 1 -Vin (GND) 2 NC 3 Remote 4 +Vin (Vcc) 5 -Vout 6 -Sense 7 Trim 8 +Sense 9 +Vout 85.0 (3.35) 33.8 (1.33) screw 1 78.0 (3.071) 61.0 (2.40) 54.0 (2.126) 50.8 (2.00) screw 2 NC: No Connection The screw 1 locked torque: MAX 11.2kgf-cm/1.14N-m screw 3 The screw 2 locked torque: MAX 5.2kgf-cm/0.51N-m O4 .30 40.6 (1.60) 32.5 (1.28) 20.0 (0.787) 3x0 .5 ) 18.0 (0.71) 38.8 (1.53) The screw 3 locked torque: MAX 16.8kgf-cm/1.64N-m Dimensions in mm (inch) Tolerances 0.5 (0.02) Pin pich tolerances 0.25 (0.01) Mounting hole pich tolerances 0.25 (0.01) 30.5 (1.20) 2-M (O0 .17 78.0 (3.071) (c) Copyright 2021 Traco Electronic AG Specifications can be changed without notice. www.tracopower.com Rev. March 17, 2021 Page 5 / 5