1
PME295
• EMI suppressor, class Y1, metallized paper capacitor
• Safety capacitor, ceramic replacement
• 470 – 4700 pF, 440/480 VAC, +115 °C, test voltage 4000 VAC 60 s
TYPICAL APPLICATIONS CONSTRUCTION
TECHNICAL DATA
Safety capacitor for bridging of double or
reinforced insulation applications requiring
voltage test up to 4000 VAC 60 seconds.
PME295 can be left in place during this
test.
Multi-layer metallized paper. Encapsulated
and impregnated in self-extinguishing
material meeting the requirements of UL
94V-0.
ENVIRONMENTAL TEST DATA
Vibration IEC 60068-2-6 3 directions at 2 hour each No visible damage
Test Fc 10 – 500 Hz at 0.75 mm or 98 m/s2 No open or short circuit
Bump IEC 60068-2-29 4000 bumps at 390 m/s2 No visible damage
Test Eb No open or short circuit
Solderability IEC 60068-2-20 Solder globule method Wetting time < 1 s
Test Ta
Active flammability EN 132400
Passive flammability IEC 60384-14 (1993)
EN 132400
Humidity IEC 60068-2-3 +40°C and 90 – 95% R.H. 56 days
Test Ca
• Self-extinguishing encapsulation. The
material is recognized according to
UL 94 V-0.
• Excellent self-healing properties.
Ensures long life even when subjected to
frequent overvoltages.
• High dU/dt capability.
• Good resistance to ionisation due to
impregnated dielectric.
• The capacitors meet the most stringent
IEC humidity class, 56 days.
• The impregnated paper ensures
excellent stability giving outstanding
reliability properties, especially in
applications having continuous
operation.
Suppression versus frequency. Typical values.
1 MHz
70
60
50
40
30
20
10
0
f
dB
5 3010 100
3 200
Attenuation
470 pF
1500 pF
4700 pF
440 VAC 50/60 Hz (ENEC)
480 VAC 50/60 Hz (UL, CSA)
470 – 4700 pF
± 20%
–40 to +115 °C
40/115/56/B
ENEC, UL, CSA
≤ 1.3 % at 1 kHz
≥ 12000 MΩ
Measured at 500 VDC after 60 s, +23°C
Tabulated self-resonance frequencies f0 refer to 5 mm
lead length.
Recommended voltage: ≤ 1500 VDC
The 100% screening factory test is carried out at 4000
VAC, 50 Hz, 2 s. The voltage level is selected to meet
the requirements in applicable equipment standards.
All electrical characteristics are checked after the test.
Rated voltage
Capacitance range
Capacitance tolerance
Temperature range
Climatic category IEC
Approvals
Dissipation factor tanδ
Insulation resistance
Resonance frequency
In DC applications
Test voltage between
terminals
l = standard : 30 +5/-0 mm
option : short leads, tolerance +0/-1 mm
(standard 6 mm, code R06)
Other lead lengths on request