Data Sheet August 12, 2010 EQD075 Series (Eighth-Brick)DC-DC Converter Power Modules 18- 60Vdc Input; 3.3 to 5.0Vdc Output; 75W RoHS Compliant Features Applications Distributed power architectures Wireless Networks Optical and Access Network Equipment Enterprise Networks Options Positive logic, Remote On/Off Auto restart after fault protection shutdown Pin length Compliant to RoHS EU Directive 2002/95/EC (-Z versions) Compliant to RoHS EU Directive 2002/95/EC with lead solder exemption (non-Z versions) High efficiency - 92% at 5.0Vo, full load, 24Vin Industry standard Eighth brick footprint and pin out 57.9 mm x 22.8 mm x 8.5 mm (2.28 in. x 0.90 in. x 0.335 in.) 3:1 Input voltage range: 18 - 60 Vdc Input under/overvoltage protection Output overcurrent/voltage protection Over-temperature protection Tightly regulated output Remote sense No reverse current during output shutdown Negative logic, Remote On/Off Output voltage programmable from 3.0 Vdc to 5.5Vdc Input-to-output isolation (Basic Insulation: 1500V) Wide operating temperature range (-40C to 85C) Meets conducted emissions requirements of FCC/EN55022 Class A without external filter Within FCC and VDE Class A Radiated Limits UL* 60950-1Recognized, CSA C22.2 No. 60950-103 Certified, and VDE 0805:2001-12 (EN60950-1) Licensed Meets the voltage and current requirements for ETSI 300-132-2 and complies with and licensed for Basic insulation rating per EN60950-1 ISO** 9001 and ISO 14001 certified manufacturing facilities Description The EQD075 series DC-DC converters are a new generation of open-frame DC/DC power modules designed to support a 3:1 input voltage range, that allows operation in both 24V or 48V nominal input voltage systems, thus eliminating the need for separate power modules for each input voltage range. These single output DC-DC converters operate over an input voltage range of 18 to 60 Vdc. The series is also designed to provide a wide output voltage set/trim range of 3.0 to 5.5Vdc, with output current up to 20A at 3.3Vdc or 15A at 5.0Vdc in an industry standard eighth brick package. The output is isolated from the input, allowing versatile polarity configurations and grounding connections. Built in filtering for both input and output minimizes the need for external filtering. * UL is a registered trademark of Underwriters Laboratories, Inc. CSA is a registered trademark of Canadian Standards Association. VDE is a trademark of Verband Deutscher Elektrotechniker e.V. ** ISO is a registered trademark of the International Organization of Standards Document No: DS05-031 ver. 1.31 PDF name: EQD075A.pdf Data Sheet August 12, 2010 EQD075 Series Single Output: Eighth Brick Power Modules: 18-60Vdc Input; 3.3 to 5.0Vdc Output; 75W Absolute Maximum Ratings Stresses in excess of the absolute maximum ratings can cause permanent damage to the device. These are absolute stress ratings only, functional operation of the device is not implied at these or any other conditions in excess of those given in the operations sections of the data sheet. Exposure to absolute maximum ratings for extended periods can adversely affect the device reliability. Parameter Device Symbol Min Max Unit Input Voltage Continuous A VIN -0.3 60 Vdc VIN, trans -0.3 75 Vdc A TA -40 85 C A Tstg -55 125 C 1500 Vdc Transient (100 ms) Operating Ambient Temperature (see Thermal Considerations section) Storage Temperature I/O Isolation (100% factory Hi-Pot tested) Input - Output A Electrical Specifications Unless otherwise indicated, specifications apply over all operating input voltage, resistive load, and temperature conditions. Parameter Device Symbol Min Typ Max Unit A VIN 18 24/48 60 Vdc A IIN,max 6 Adc A IIN, Stby 25 mA A IIN, NL 110 mA Inrush Transient A It 2 1 As Input Reflected Ripple Current, peak-to-peak (5Hz to 20MHz, 12H source impedance; o Ta 25 C, Cin = 33F) A 30 mAp-p Input Ripple Rejection (100 - 120Hz) A Operating Input Voltage Maximum Input Current (VIN=0 to VIN, max , Vo = Vo,set, IO=IO, max ) Input Stand-by Current Module on / off disabled (VIN = VIN, nom, Vo = 0 V) Input No Load Current Module on / off enabled (VIN = VIN, nom, Io = 0 A) 50 2 dB CAUTION: This power module is not internally fused. An input line fuse must always be used. This power module can be used in a wide variety of applications, ranging from simple standalone operation to being part of a complex power architecture. To preserve maximum flexibility, internal fusing is not included, however, to achieve maximum safety and system protection, always use an input line fuse. The safety agencies require a very fast acting surface mount fuse with a maximum rating of 6.3 A (see Safety Considerations section). Based on the information provided in this data sheet on inrush energy and maximum dc input current, the same type of fuse with a lower rating can be used. Refer to the fuse manufacturer's data sheet for further information. LINEAGE POWER 2 Data Sheet August 12, 2010 EQD075 Series Single Output: Eighth Brick Power Modules: 18-60Vdc Input; 3.3 to 5.0Vdc Output; 75W Electrical Specifications (continued) Parameter Output Voltage Set-point Device Symbol Min A VO, set -1.6 A VO -3 Typ Max Unit +1.6 % VO, set +3 % VO (VIN = VIN, min=24/48, IO =IO, max, TA =25C) Output Voltage - (Over all line, load, and Temp Conditions Until end of life) Output Regulation Line (VIN = VIN, min to VIN, max) A 0.05 0.2 % VO, nom Load (IO = IO, min to IO, max) A 0.05 0.2 % VO, nom Temperature (Tref =TA, min to TA, max) A 0.25 1 % VO, nom RMS (5Hz to 20MHz bandwidth) A 5 20 mVrms Peak-to-Peak (5Hz to 20MHz bandwidth) A 50 80 mVpk-pk CO 0 5000 F Output Ripple and Noise on nominal output (VIN =VIN, nom and IO = IO, min to IO, max, Cout = 1F ceramic // 10F Tantalum capacitor) 3.3 to 5.0V output External Capacitance ESR 10 m A Output Current @ Vo = 3.3V A Io 0 20 A dc @ Vo = 5V A Io 0 15 A dc Output Current Limit Inception (Hiccup Mode) (Vo = 95% Vo, set ) A IO, lim 105 115 150 % Io, max Output Short-Circuit Current A IO, s/c 150 % Io, max @ Vo = 3.3V, IO = 20A A 87 % @ Vo = 5V, IO = 15A A 92 % @ Vo = 3.3V, IO = 20A A 88 % @ Vo = 5V, IO = 15A A 90 A fsw o VO 250 mV @ 25 C Efficiency VIN= 24V, TA=25C, IO= IO, max A VIN= 48V, TA=25C, IO= IO, max A Switching Frequency LINEAGE POWER 160 % KHz 3 Data Sheet August 12, 2010 EQD075 Series Single Output: Eighth Brick Power Modules: 18-60Vdc Input; 3.3 to 5.0Vdc Output; 75W Electrical Specifications (continued) Parameter Device Symbol Min A Vpk ts Vpk ts Typ Max Unit 2 4 %Vo 80 150 s 2 4 %Vo 80 150 s Dynamic Load Response (dIo/dt= 1A / 10s; VIN = VIN, nom; TA=25C) Load Change from Io= 50% to 75% of Io,max Peak Deviation Settling Time (Vo<10% peak deviation) Load Change from Io= 50% to 25% of Io,max Peak Deviation Settling Time (Vo<10% peak deviation) A Isolation Specifications Parameter Min Typ Max Unit Isolation Capacitance 1000 pF Isolation Resistance 10 M Typ Max General Specifications Parameter Min Calculated MTBF (VIN = 24V, IO=80%IO, max, TA=40C) Weight LINEAGE POWER 1,677,152 25.3 (0.89) Unit Hours g (oz.) 4 Data Sheet August 12, 2010 EQD075 Series Single Output: Eighth Brick Power Modules: 18-60Vdc Input; 3.3 to 5.0Vdc Output; 75W Feature Specifications Unless otherwise indicated, specifications apply over all operating input voltage, resistive load, and temperature conditions. See Feature Descriptions for additional information. Parameter Device Symbol Min Typ Max Unit Input low Voltage = 0.0 V A VIL -0.7 1.2 V Input low Current = 1 mA A IIL 1.0 mA Input High Voltage = 5.0 V A VIH 5 V Input High Current = 0 mA A IIH 50 A Case 1: On/Off input is set to Logic High and then input power is applied (delay from instant at which VIN = VIN, min until Vo =10% of Vo,nom) A Tdelay 15 20 msec Case 2: Input power is applied for at least one second and then the On/Off input is set to logic high (delay from instant at which Von/Off = 0.9V until Vo=10% of Vo, set) A Tdelay 5 10 msec Output voltage Rise time (time for Vo to rise from 10% of Vo, nom to 90% of Vo, nom) Vo, nom set to 3.3V A Trise 10 15 msec Output voltage Rise time (time for Vo to rise from 10% of Vo, nom to 90% of Vo, nom) Vo, nom set to 5.0V A Trise 15 20 msec 1 % VO, set 17 18 V On/Off Signal interface (VIN=VIN, min to VIN, max ; Open collector or equivalent, Signal referenced to VIN (-) terminal Logic Low (Module OFF) Logic High (Module ON) Turn-On Delay and Rise Times o (IO=80 % IO, max , TA = 25 C) Output voltage overshoot - Startup o IO= 80% of IO, max; TA = 25 C Input Undervoltage Lockout A VUVLO Turn-on Threshold Turn-off Threshold 14 Hysteresis Input Over voltage Lockout 15.5 V 1.5 A VOVLO Turn-on Threshold 60 62 Turn-off Threshold 64 Hysteresis 2 V 65 V 10 % VO,nom 3.0 5.5 Vdc 5.7 6.5 Vdc Output Voltage Set point Adjustment Output remote sense voltage range A VSENSE (Max voltage drop is 0.5 V) Output voltage adjustment range (TRIM) A Over voltage protection A VOV, set Over Temperature Protection A Tref LINEAGE POWER 130 C 5 Data Sheet August 12, 2010 EQD075 Series Single Output: Eighth Brick Power Modules: 18-60Vdc Input; 3.3 to 5.0Vdc Output; 75W Characteristic Curves O 4 Io = 10A 3 Io = 0.05A 2 1 0 65 INPUT VOLTAGE, VIN (V) Figure 1. Typical Input characteristics at room temperature (Vo = 3.3V). OUTPUT VOLTAGE 95 Vin = 18V EFFICIENCY, (%) 90 85 Vin = 60V 80 Vin = 48V 75 Vin = 24V 70 0 5 10 15 20 OUTPUT CURRENT, IO (A) Figure 3. Typical Output Ripple and Noise at Vo = 3.3V and Io = 20A. LINEAGE POWER TIME, t (0.2 ms/div) Figure 5. Transient Response to a Dynamic Load Change from 50% to 75% to 50% of full load (3.3V@20A) at Vin = 48V. OUTPUT VOLTAGE VO (V) (50mV/div) OUTPUT VOLTAGE Figure 2. Typical Converter Efficiency versus Output Current at room temperature (Vo = 3.3V). TIME, t (1 s/div) TIME, t (2 ms/div) Figure 4. Typical Start-Up Characteristics from Remote ON/OFF (Vo = 3.3V, Io = 20A, Vin = 48V). VO (V) (200 mV/div) 55 IO (A) (5A/div) 45 VO (V) (200 mV/div) 35 IO (A) (5A/div) 25 OUTPUT CURRENT 15 OUTPUT CURRENT INPUT CURRENT, IIN (A) Io = 20A 5 VO (V) (1V/div) 6 ON/OFF VOLTAGE VOn/off (V) (2V/div) OUTPUT VOLTAGE The following figures provide typical characteristics for EQD075A at TA = 25 C TIME, t (0.2 ms/div) Figure 6. Transient Response to a Dynamic Load Change from 50% to 75% to 50% of full load (3.3V@20A) at Vin = 24V. 6 Data Sheet August 12, 2010 EQD075 Series Single Output: Eighth Brick Power Modules: 18-60Vdc Input; 3.3 to 5.0Vdc Output; 75W Characteristic Curves (continued) OUTPUT VOLTAGE 5 Io = 15A 4 Io = 7.5A 3 Io = 0A 0 55 65 INPUT VOLTAGE, VIN (V) Figure7. Typical Input characteristics at room temperature (Vo = 5V). 95 Vin = 18V Vin = 60V 85 Vin = 48V 80 70 0 5 10 15 OUTPUT CURRENT, IO (A) VO (V) (50mV/div) OUTPUT VOLTAGE Figure 8. Typical Converter Efficiency versus Output Current at room temperature (Vo = 5V). TIME, t (1 s/div) Figure 9. Typical Output Ripple and Noise at Vo = 5V and Io = 15A. TIME, t (0.2ms/div) Figure 11. Transient Response to a Dynamic Load Change from 50% to 75% to 50% of full load (5V@15A) at Vin =48V. VO (V) (100 mV/div) Vin = 24V 75 IO (A) (5A/div) EFFICIENCY, (%) 90 OUTPUT VOLTAGE TIME, t (5 ms/div) Figure 10. Typical Start-Up Characteristics from Remote ON/OFF (Vo = 5V, Io = 15A, Vin = 48V) VO (V) (100 mV/div) 45 OUTPUT VOLTAGE 35 IO (A) (5A/div) 25 OUTPUT CURRENT 15 VOn/off (V) (5V/div) 1 ON/OFF VOLTAGE 2 OUTPUT CURRENT INPUT CURRENT, IIN (A) 6 VO (V) (2V/div) The following figures provide typical characteristics for EQD075A at TA = 25O C TIME, t (0.2ms/div) Figure 12. Transient Response to a Dynamic Load Change from 50% to 75% to 50% of full load (5V@15A) at Vin =24V. 7 Data Sheet August 12, 2010 EQD075 Series Single Output: Eighth Brick Power Modules: 18-60Vdc Input; 3.3 to 5.0Vdc Output; 75W Characteristic Curves (continued) The following figures provide typical characteristics for EQD075A at TA = 25O C 25 2.0 m/s (400 lfm) 10 NC 0.5 m/s (100 lfm) 1.0 m/s (200 lfm) 5 2.0 m/s (400 lfm) 20 15 OUTPUT CURRENT (A) OUTPUT CURRENT (A) 20 15 NC 0.5 m/s (100 lfm) 10 1.0 m/s (200 lfm) 5 0 0 20 30 40 50 60 70 80 90 O 20 30 40 50 60 70 80 90 O TEMPERATURE ( C) TEMPERATURE ( C) Figure 13. Thermal Derating Curves for the EQD075 module at 24Vin and Vo=5V. Figure 16. Thermal Derating Curves for the EQD075 module at 48Vin and Vo=3.3V. 20 OUTPUT CURRENT (A) 2.0 m/s (400 lfm) 15 10 NC 1.0 m/s (200 lfm) 0.5 m/s (100 lfm) 5 0 20 30 40 50 60 70 80 90 O TEMPERATURE ( C) Figure 14. Thermal Derating Curves for the EQD075 module at 48Vin and Vo=5V. OUTPUT CURRENT (A) 25 2.0 m/s (400 lfm) 20 15 NC 0.5 m/s (100 lfm) 10 1.0 m/s (200 lfm) 5 0 20 30 40 50 60 70 80 90 O TEMPERATURE ( C) Figure 15. Thermal Derating Curves for the EQD075 module at 24Vin and Vo=3.3V. LINEAGE POWER 8 Data Sheet August 12, 2010 EQD075 Series Single Output: Eighth Brick Power Modules: 18-60Vdc Input; 3.3 to 5.0Vdc Output; 75W Test Configurations Design Considerations Input Filtering CURRENT PROBE TO OSCILLOSCOPE The power module should be connected to a low acimpedance source. Highly inductive source impedance can affect the stability of the power module. For the test configuration in Figure 17, a 220F electrolytic capacitor (ESR<0.1 at 100 kHz), mounted close to the power module helps ensure the stability of the unit. Consult your sales representative for further applications guidelines. LTEST V IN(+) 12H BATTERY CIN C S 220F Electrolytic 33 F Ceramic E.S.R.<0.1 @ 20C 100kHz COM Safety Considerations NOTE: Measure input reflected ripple current with a simulated source inductance (L TEST ) of 12H. Capacitor C S offsets possible battery impedance. Measure current as shown above. Figure 17. Input Reflected Ripple Current Test Setup. COPPER STRIP VO (+) RESISTIVE LOAD 1uF . 10uF SCOPE COM GROUND PLANE NOTE: All voltage measurements to be taken at the module terminals, as shown above. If sockets are used then Kelvin connections are required at the module terminals to avoid measurement errors due to socket contact resistance. Figure 18. Output Ripple and Noise Test Setup. Rdistribution Rcontact Rcontact VIN(+) RLOAD VO VIN Rdistribution Rcontact Rcontact COM Rdistribution VO Rdistribution COM NOTE: All voltage measurements to be taken at the module terminals, as shown above. If sockets are used then Kelvin connections are required at the module terminals to avoid measurement errors due to socket contact resistance. For safety-agency approval of the system in which the power module is used, the power module must be installed in compliance with the spacing and separation requirements of the end-use safety agency standard, i.e., UL60950-1, CSA C22.2 No. 60950-103, EN60950-1 and VDE 0805:2001-12. These converters have been evaluated to the spacing requirements for Basic insulation, per the above safety standards; and 1500 Vdc is applied from Vin to Vout to 100% of outgoing production. For end products connected to -48V dc nominal DC MAINS (i.e. central office dc battery plant), no further fault testing is required. For all input voltages, other than DC MAINS, where the input voltage is less than 60V dc, if the input meets all of the requirements for SELV, then: The output may be considered SELV. Output voltages will remain within SELV limits even with internally-generated non-SELV voltages. Single component failure and fault tests were performed in the power converters. One pole of the input and one pole of the output are to be grounded, or both circuits are to be kept floating, to maintain the output voltage to ground voltage within ELV or SELV limits. The power module has ELV (extra-low voltage) outputs when all inputs are ELV. All flammable materials used in the manufacturing of these modules are rated 94V-0, or tested to the UL60950 A.2 for reduced thickness. The input to these units is to be provided with a maximum 6.3 A very fast-acting surface mount fuse in the unearthed lead. Figure 19. Output Voltage and Efficiency Test Setup. VO. IO Efficiency = VIN. IIN x 100 % 9 Data Sheet August 12, 2010 EQD075 Series Single Output: Eighth Brick Power Modules: 18-60Vdc Input; 3.3 to 5.0Vdc Output; 75W Feature Descriptions Remote On/Off The EQD075 series power modules have primary referenced remote On/Off. The remote on/off is open collector compatible with the signal common referenced to the negative input. The standard remote on/off negative logic is such that a unit operates (ON) when the remote on/off signal is low or short circuit to minus VIN. A module will be OFF when the remote on/off pin is open circuit or when the remote on/off signal is high. The optional positive logic remote on/off is such that a unit operates (ON) when the remote on/off signal is high or open-circuit. A unit will be OFF when the remote on/off signal is low or short-circuited to minus VIN. VO ON/OFF Von/off Over Voltage Protection The output over voltage protection scheme of the modules has an independent over voltage loop to prevent single point of failure. This protection feature latches in the event of over voltage across the output. Cycling the on/off pin or input voltage resets the latching protection feature. If the auto-restart option (4) is ordered, the module will automatically restart upon an internally programmed time elapsing. Remote sense VIN(+) Ion/off circuit shuts down and latches off the module when the maximum device reference temperature is exceeded. The module can be restarted by cycling the dc input power for at least one second or by toggling the remote on/off signal for at least one second. If the auto-restart option (4) is ordered, the module will automatically restart upon cool-down to a safe temperature. COM VIN(-) Figure 20. Circuit configuration for using Remote On/Off Implementation. Overcurrent Protection To provide protection in a fault (output overload) condition, the unit is equipped with internal current-limiting circuitry and can endure current limiting continuously. At the point of current-limit inception, the unit enters a hiccup mode. If the unit is not configured with auto-restart, then it will latch off following the over current condition. The module can be restarted by cycling the dc input power for at least one second or by toggling the remote on/off signal for at least one second. If the unit is configured with the auto-restart option (4), it will remain in the hiccup mode as long as the overcurrent condition exists; it operates normally, once the output current is brought back into its specified range. Input Undervoltage Lockout The EQD075 series power modules have a Remote Sense feature to minimize the effects of distribution losses by regulating the voltage at the Remote Sense pin (See Figure 21). The voltage between the Sense pin and Vo pin must not exceed 0.5V. The opened sense line resistor value should be selected in range of 30 ohm - 100 ohm that eases use of external parallel load share controller. The amount of power delivered by the module is defined as the output voltage multiplied by the output current (Vo x Io). When using Remote Sense, the output voltage of the module can increase, which, if the same output is maintained, increases the power output from the module. Make sure that the maximum output power of the module remains at or below the maximum rated power. When the Remote Sense feature is not being used, connect the Remote Sense pins to the output pins of the module. SENSE(+) SENSE(-) SUPPLY II CONTACT RESISTANCE VI(+) VO(+) VI(-) VO(-) IO LOAD CONTACT AND DISTRIBUTION LOSSES Figure 21. Effective Circuit Configuration for remote sense operation. At input voltages below the input under voltage lockout limit, the module operation is disabled. The module will begin to operate at an input voltage above the under voltage lockout turn-on threshold. Overtemperature Protection These modules feature an overtemperature protection circuit to safeguard against thermal damage. The LINEAGE POWER 10 Data Sheet August 12, 2010 EQD075 Series Single Output: Eighth Brick Power Modules: 18-60Vdc Input; 3.3 to 5.0Vdc Output; 75W shutdown an internal feature implemented in the module ensures there will be no reverse current. Feature Descriptions (continued) Output Voltage Programming Thermal Considerations The output voltage is adjustable between 3.0 to 5.5V (A version). A resistor placed between the Trim pin and Sense (+) increases the output voltage and a resistor placed between the Trim pin and Sense (-) decreases the output voltage. Figure 22 shows the circuit configuration using an external resistor. The trim resistor should be positioned close to the module. If the trim pin is not used then the pin shall be left open. If no trim resistor is connected, for the A version, the output voltage will be 5V. The following equations determine the required external resistor value to obtain a percentage output voltage change of %. To decrease output voltage set point: Power modules operate in a variety of thermal environments; however, sufficient cooling should be provided to help ensure reliable operation. Considerations include ambient temperature, airflow, module power dissipation, and the need for increased reliability. A reduction in the operating temperature of the module will result in an increase in reliability. The thermal data is based on physical measurements taken in a wind tunnel. The test set-up is shown in Figure 23. 25.4_ (1.0) Wind Tunnel PWBs 510 Rtrim down 10.2 K % Power Module Where, % Vo , nom Vdesired 100 Vo , nom 76.2_ (3.0) x Vdesired = Desired output voltage set point (V). To increase the output voltage set point 5.1*Vo , nom * 100 % 510 Rtrim up 10.2 K 1.225 * % % Although the output voltage can be increased by both the remote sense and by the trim, the maximum increase for the output voltage is not the sum of both. The maximum absolute increase in output voltage, due to simultaneous remote sense and trim increases, shall not exceed the larger of the specified individual remote sense or trim maximum limits shown in the Features Specifications table. VIN(+) VO(+) SENSE (+) Rtrim-up ON/OFF 6.55_ (0.258) Probe Location for measuring airflow and ambient temperature Air flow Figure 23. Thermal Test Set up. The thermal reference point, Tref, used in the specifications is shown in Figure 24. For reliable operation, this temperature should not exceed 125OC. Please refer to the Application Note "Thermal Characterization Process For Open-Frame BoardMounted Power Modules" for a detailed discussion of thermal aspects including maximum device temperatures. LOAD TRIM Rtrim-down VIN(-) SENSE (-) VO(-) Tref Figure 22. Circuit Configuration to program output voltage using an external resistor. Figure 24. Tref Temperature Measurement Location. Pre-Bias Immunity The modules are able to start into a pre-biased output with a monotonic rise of the output voltage. During 11 Data Sheet August 12, 2010 EQD075 Series Single Output: Eighth Brick Power Modules: 18-60Vdc Input; 3.3 to 5.0Vdc Output; 75W Mechanical Outline Dimensions are in millimeters and [inches]. Tolerances: x.x mm 0.5 mm [x.xx in. 0.02 in.] (Unless otherwise indicated) x.xx mm 0.25 mm [x.xxx in 0.010 in.] TOP VIEW SIDE VIEW BOTTOM VIEW LINEAGE POWER 12 Data Sheet August 12, 2010 EQD075 series Single Output: Eighth Brick Power Modules: 18-60Vdc Input; 3.3 to 5.0Vdc Output; 75W Recommended Pad Layout Dimensions are in millimeters and [inches]. Tolerances: x.x mm 0.5 mm [x.xx in. 0.02 in.] (Unless otherwise indicated) x.xx mm 0.25 mm [x.xxx in 0.010 in.] LINEAGE POWER 13 Data Sheet August 12, 2010 EQD075 Series Single Output: Eighth Brick Power Modules: 18-60Vdc Input; 3.3 to 5.0Vdc Output; 75W Through-Hole Lead-Free Soldering Information The RoHS-compliant through-hole products use the SAC (Sn/Ag/Cu) Pb-free solder and RoHS-compliant components. They are designed to be processed through single or dual wave soldering machines. The pins have an RoHS-compliant finish that is compatible with both Pb and Pb-free wave soldering processes. A maximum preheat rate of 3C/s is suggested. The wave preheat process should be such that the temperature of the power module board is kept below 210C. For Pb solder, the recommended pot temperature is 260C, while the Pb-free solder pot is 270C max. Not all RoHS-compliant through-hole products can be processed with paste-through-hole Pb or Pb-free reflow process. If additional information is needed, please consult with your Lineage Power Power System representative for more details. Post solder Cleaning and Drying Considerations Post solder cleaning is usually the final circuit-board assembly process prior to electrical board testing. The result of inadequate cleaning and drying can affect both the reliability of a power module and the testability of the finished circuit-board assembly. For guidance on appropriate soldering, cleaning and drying procedures, refer to Lineage Power Board Mounted Power Modules: Soldering and Cleaning Application Note. LINEAGE POWER 14 Data Sheet August 12, 2010 EQD075 series Single Output: Eighth Brick Power Modules: 18-60Vdc Input; 3.3 to 5.0Vdc Output; 75W Ordering Information Please contact your Lineage Power Sales Representative for pricing, availability and optional features. Table 1. Device Code EQD075A1 18 - 60V Output Voltage 5/3.3V EQD075A41 18 - 60V 5/3.3V EQD075A41Z 18 - 60V 5/3.3V 15/20A EQD075A641 18 - 60V 5/3.3V 15/20A EQD075A641Z 18 - 60V 5/3.3V 15/20A EQD075A81Z 18 - 60V 5/3.3V 15/20A Product codes Input Voltage Output Current 15/20A 15/20A 90% Connector Type TH 90% TH 108994455 90% TH CC109114393 90% TH CC109126117 90% TH CC109147880 90% TH CC109129103 Efficiency Comcodes 108994463 Table 2. Device Options Option Negative remote on/off logic Auto-restart (from OTP, OVP, OCP) Pin Length: 3.68 mm 0.25 mm (0.145 in. 0.010 in.) Pin Length: 2.79 mm 0.25 mm (0.110 in. 0.010 in.) RoHS Compliant Suffix 1 4 6 8 Z Asia-Pacific Headquarters Tel: +65 6593 7211 World Wide Headquarters Lineage Power Corporation 601 Shiloh Road, Plano, TX 75074, USA +1-800-526-7819 (Outside U.S.A.: +1-972-244-9428) www.lineagepower.com e-mail: techsupport1@lineagepower.com Europe, Middle-East and Africa Headquarters Tel: +49 89 878067-280 India Headquarters Tel: +91 80 28411633 Lineage Power reserves the right to make changes to the product(s) or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. Lineage Power DC-DC products are protected under various patents. Information on these patents is available at www.lineagepower.com/patents. (c) 2009 Lineage Power Corporation, (Plano, Texas) All International Rights Reserved. Document No: DS05-031 ver. 1.31 PDF name: EQD075A.pdf