DC/DC CONVERTERS 36-100 W High Efficiency DC/DC Converters 1
2 YEAR WARRANTY
EXQ125 Series
Single output
•Ultra-high efficiency topology, 91% at 3.3 V,
88% typical at 1.8 V
•Industry standard footprint
•Wide baseplate temperature, -40 °C to +100 °C
•90% to 110% output trim
•No minimum load
•Overvoltage protection
•Remote ON/OFF
•Available RoHS compliant
The EXQ125 is a new ultra high efficiency, open-frame, isolated converter series in
an industry standard quarter-brick footprint that provides up to 100 Watts of output
power. The EXQ125 delivers very high output current at low voltages, and excellent
useable power density for today’s high end applications. The seven models in the
series feature an input voltage range of 33 Vdc to 75 Vdc and are available in output
voltages of 12 V, 5 V, 3.3 V, 2.5 V, 1.8 V, 1.5 V and 1.2 V. The output voltage on each
model is adjustable from 90% to 110% of the nominal value. The EXQ125 series
also has a remote ON/OFF capability. Overcurrent and overvoltage protection
features are included as standard. With full international safety approval including
EN60950 (TÜV Rheinland) and UL/cUL1950, the EXQ125 reduces compliance costs
and time to market.
All specifications are typical at nominal input, full load at 25 °C unless otherwise stated
EMC CHARACTERISTICS
Conducted emissions EN55022 (See Note 2) Level A
EN55022 (See Note 2) Level B
Radiated emissions EN55022 Level B
Immunity:
ESD air EN61000-4-2 8 kV (NP), 15 kV (NP)
ESD contact EN61000-4-2 6 kV (NP), 8 kV (NP)
Radiated field enclosure EN61000-4-3 10 V/m (NP)
Conducted (DC power) EN61000-4-6 10 V (NP)
Conducted (signal) EN61000-4-6 10 V (NP)
Input transients ETS 300 132-2, ETR 283
GENERAL SPECIFICATIONS
Efficiency See table
Operational Input/output 1500 Vdc
Input/baseplate 1500 Vdc
Switching frequency Fixed 400 kHz typ.
Approvals and EN60950 (TÜV Rheinland)
standards (See Note 4) UL/cUL1950
Material flammability UL94V-0
Weight 45 g (1.6 oz)
MTBF Telcordia SR-332 2,284,281 hours
@ 25 °C, 100% load
ground benign
ENVIRONMENTAL SPECIFICATIONS
Thermal performance Operating baseplate -40 °C to +100 °C
temperature
Non-operating -40 °C to +125 °C
OUTPUT SPECIFICATIONS
Voltage adjustability 90% to 110%
Set point accuracy ±1.5% max.
Line regulation Low line to high line ±0.1% max.
Load regulation Full load to min. load 0.2% max.
Minimum load 0 A
Overshoot At turn-on and turn-off None
Undershoot 1.2 V, 1.5 V (Z), 1.8 V (Z), None
2.5 V (Z) and 3.3 V (Z) models
Ripple and noise 5 Hz to 20 MHz 60 mV pk-pk
20 mV rms
Transient response 2% typ. deviation
(See Note 1) 100 µs recovery to
within 1% of setpoint
INPUT SPECIFICATIONS
Input voltage range 48 Vin nominal 33-75 Vdc
Input current No load 85 mA
Remote OFF 20 mA
Input current (max.) 3.5 A max. @ Io max.
(See Note 3) and Vin = 33-75 Vdc
Input reflected ripple (See Note 5) 300 mA (pk-pk) typ.
Active high remote ON/OFF
Logic compatibility Open collector ref to -input
ON Open circuit or >4.0 Vdc
OFF <1.2 Vdc
Undervoltage lockout Power up 32.5 V (typ)
Power down 30.5 V (typ)
Start-up time Power up 6 ms (typ)
(See Note 6) Remote ON/OFF 2 ms (typ)
SPECIFICATIONS
File Name: exq125s.pdf Rev (02): 17 Nov 2005
TÜV