ScopeMeter® 190 Series II
Technical Data
190 Series II – a new generation of ScopeMeter
The 190 Series II include these capabilities:
Up to four independent floating isolated inputs, up to 1000 V
High-speed sampling: Up to 2.5 GS/sec on 2 channels simultaneously
Deep memory: 10,000 points per trace waveform capture (scope mode)
CAT III 1000 V/CAT IV 600 V safety rated for industrial environments
Up to seven hours of battery operation using BP291
Isolated USB host port for direct data storage to a USB memory device;
USB device port for easy PC communication
Easy access battery door for quick battery swaps in the field
Compact and only 2.2 kg (4.8 lb)
Security slot: lock down oscilloscope with Kensington® lock while
unattended
IP 51 rating, dust- and drip-proof
Connect-and-View triggering for intelligent, automatic triggering on
fast, slow and even complex signals
Frequency Spectrum using FFT-analysis
Automatic capture and REPLAY of 100 screens
ScopeRecord Roll mode gives 30,000 points per input channel for low
frequency signal analysis
TrendPlot paperless recorder mode with deep memory for long-term
automatic measurements
5,000 count DMM included in the 2-channel models
C
E
R
T
I
F
I
E
D
T
O
M
E
E
T
I
S
O
9
0
0
1
Q
U
A
L
I
T
Y
M
A
N
A
G
E
M
E
N
T
S
Y
S
T
E
M
ScopeMeter 190 Series II – the first
high-performance scopes built for
harsh industrial environments
Introducing the first high-performance portable oscil-
loscopes with 2 or 4 independently insulated input
channels, an IP51 dust- and dripwater proof rating and a
CAT III 1000 V/CAT IV 600 V safety rating. Choose from
200 MHz, 100 MHz or 60 MHz bandwidth models. Now
plant maintenance engineers can take a 2- or 4-channel
scope into the harsh world of industrial electronics.
2 Fluke Corporation ScopeMeter 190 Series II2 Fluke Corporation ScopeMeter 190 Series II
Oscilloscope Modes
190-062 190-102 190-202 190-104 190-204
Vertical deflection
Number of channels 2224 4
Bandwidth 60 MHz 100 MHz 200 MHz 100 MHz 200 MHz
Rise time 5.8 ns 3.5 ns 1.7 ns 3.5 ns 1.7 ns
Number of scope inputs 2 input channels plus external trigger 4 input channels
Channel architecture All inputs fully insulated from each other and from ground
Inputs may be activated in any combination
Input coupling AC or DC, with ground level indicator
Input sensitivity 2 mV/div to 100 V/div, plus variable attenuation
Bandwidth limiter User selectable: 20 kHz, 20 MHz or full bandwidth
Normal/invert/variable On each input channel, switched separately
Input voltage CAT III 1000 V/CAT IV 600 V rated, see General Specifications for further details
Vertical resolution 8 bit
Accuracy ± (2.1 % of reading + 0.04 x range/div) @ 5 mV/div to 100 V/div
Input impedance 1 MΩ ± 1 % // 14 pF ± 2 pF
Horizontal
Maximum real-time sample rate
(sampled simultaneously)
625 MS/s for each
channel
1.25 GS/s for each
channel
2.5 GS/s (2ch) 1.25 GS/s for each
channel
2.5 GS/s (2ch)
1.25 GS/s (4ch)
Record length Up to 10,000 samples per channel
Time base range 10 ns/div
to 4 s/div
5 ns/div
to 4 s/div
2 ns/div
to 4 s/div
5 ns/div
to 4 s/div
2 ns/div
to 4 s/div
Time base in a 1-2-4-sequence
Slower time/division settings using ScopeRecord Roll mode (see ‘Recorder mode’)
Maximum record length 10,000 samples per channel in scope mode;
30,000 points per channel in ScopeRecord Roll mode (see ‘Recorder mode’)
Timing accuracy ± (0.01 % of reading + 1 pixel)
Glitch capture 8 ns peak detect on each channel
(using real time sampling and data compression, at any timebase setting)
Display and acquisition
Display 153 mm (6 in) full-color LCD with LED backlight
Display modes Any combination of channels; average on/off; replay
Visible screen width 12 divisions horizontally in scope mode
Digital persistence modes off/short/medium/long/infinite and envelope mode
Waveform mathematics One mathematical operation on any 2 input channels: add/subtract/multiply; X-Y-mode
Frequency Spectrum using FFT analysis
Acquisition modes Normal, Averaged, Auto, Single Shot, ScopeRecord™ roll, glitch capture,
waveform compare with automatic “Pass/Fail testing”; Replay
Trigger and delay
Source Input A, B or External (via meter input) Input A, B, C or D
Modes Automatic Connect-and-View, free run, single shot, edge, delay, dual slope,
video, video line, selectable pulsewidth (channel A only), N-cycle
Connect-and-ViewAdvanced automatic triggering that recognizes signal patterns, automatically sets up and continuously
adjusts triggering, time base and amplitude
Automatically displays stable waveforms of complex and dynamic signals like
motor drive and control signals
Can be switched off if preferred
Video triggering (on ch.A) NTSC, PAL, PAL+, SECAM; Includes field 1, field 2 and line select
High-res, non-interlaced video Non-interlaced video with line-select, for line frequencies in the range 14 kHz up to 65 kHz
Pulse width triggering
(on channel A)
Pulse width qualified by time
Allows for triggering <t, >t, =t, ≠ t, where t is selectable in minimum steps of 0.01 div or 50 ns
Time delay 1 full screen of pre-trigger view or up to 100 screens
(=1,200 divisions) of post-trigger delay
Dual slope triggering Triggers on both rising and falling edges alike
N-cycle triggering Triggers on N-th occurrence of a trigger event; N to be set in the range 2 to 99
ScopeMeter 190 Series II Fluke Corporation 3
Automatic capture of 100 screens
When in oscilloscope mode, the instrument ALWAYS memorizes the last 100 screens—no specific user setup required. When an anomaly is
seen, the REPLAY button can be pressed to review the full sequence of screen events over and over. Instrument can be set up for triggering on
glitches or intermittent anomalies and will operate in “baby-sit” mode capturing 100 specified events
Replay Manual or continuous replay. Displays the captured 100 screens as a “live” animation, or under manual
control. Each screen has date and time-stamp
Replay storage Two sets of 100 screens each can be saved internally for later recall and analysis
Direct storage of additional sets on external flash memory drive through USB host port
FFT – frequency spectrum analysis
Shows frequency content of oscilloscope waveform using Fast Fourier Transform
Window Automatic, Hamming, Hanning or None
Automatic window Digitally re-samples acquired waveform to get optimum frequency resolution in FFT resultant
Vertical scale Linear / Logarithmic (in volts or amps)
Frequency axis Frequency range automatically set as a function of timebase range of oscilloscope
Waveform compare and pass/fail testing
Waveform Compare Provides storage and display of a reference waveform for visual comparison with newly acquired
waveforms. Reference is derived from an acquired waveform and can be modified in the ScopeMeter
Pass/Fail Testing In waveform compare mode, the ScopeMeter can be set up to store only matching (“Pass”) or only
non-matching (“Fail”) acquired waveforms in the replay memory bank for further analysis
Automatic scope measurements
Vdc, Vac rms, Vac+dc, Vpeak max, Vpeak min, Vpeak to peak, Aac, Adc, Aac+dc, frequency (in Hz), risetime (using cursors), falltime (using
cursors), phase (between any 2 inputs), pulsewidth (pos./neg.), dutycycle (pos./neg.), temperature °C, temperature °F (not for Japan), dBV, dBm
into 50 Ω and 600 Ω
Advanced power and motor drive
functions
V/Hz ratio (190-x02 only), Power Factor (PF), Watts, VA, VA reactive, VPWMac and VPWM (ac+dc) for
measurement on pulsewidth modulated motordrives and frequency inverters
Advanced functions mA*s (current-over-time, between cursors);
V*s (voltage over time, between cursors);
W*s (energy, between cursors)
Cursor measurements
Source On any input waveform or on mathematical resultant waveform (excl. X-Y-mode)
Dual horizontal lines Voltage at cursor 1 and at cursor 2, voltage between cursors
Dual vertical lines Time between cursors, 1/T between cursors (in Hz), voltage between markers, risetime with markers,
falltime with markers; Vrms between cursors, Watts between cursors
Single vertical line Min-Max and Average voltage at cursor position; frequency and rms-value of individual frequency
component in the FFT Resultant
ZOOM Ranges from full record overview to zoom in up to sample level, at any record length
4 Fluke Corporation ScopeMeter 190 Series II
190-062 190-102 190-202 190-104 190-204
Meter inputs Via 4 mm banana inputs, fully isolated from
scope inputs and scope ground
Via BNC scope inputs
Number of readings One at a time Up to 4 simultaneously
Maximum resolution 5,000 counts 999 counts
Input impedance 1 MΩ ± 1 % // 14 pF ± 2 pF
Advanced meter functions Auto/manual ranging, relative measurements (Zero reference), TrendPlot recording
The specified accuracy is valid over the temperature range 18 °C to 28 °C
Add 10 % of specified accuracy for each degree C below 18 °C or above 28 °C
Voltage
Vdc accuracy ± (0.5 % + 5 counts) ± (1.5 % + 5 counts)
Vac true rms accuracy
15 Hz to 60 Hz: ± (1 % + 10 counts) ± (1.5 % + 10 counts)
60 Hz to 1 kHz: ± (2.5 % + 15 counts)
60 Hz to 20 kHz: ± (2.5 % + 15 counts)
Vac+dc true rms accuracy
15 Hz to 60 Hz: ± (1 % + 10 counts) ± (1.5 % + 10 counts)
60 Hz to 1 kHz: ± (2.5 % + 15 counts)
60 Hz to 20 kHz: ± (2.5 % + 15 counts)
Voltmeter ranges 500 mV, 5 V, 50 V, 500 V, 1,000 V
Resistance
Ranges 500 Ω, 5 kΩ, 50 kΩ, 500 kΩ, 5 MΩ, 30 MΩ
Accuracy ± (0.6 % + 5 counts)
Other meter functions
Continuity Beeper on < 50 Ω (± 30 Ω)
Diode test Up to 2.8 V
Current (A) Adc, Aac, Aac+dc using an optional current clamp or shunt
Scaling factors: 0.1 mV/A, 1 mV/A to 100 V/A and 400 mV/A
Temperature With optional accessories. Scale factors 1 °C/mV or 1 °F/mV
Meter Modes
ScopeMeter 190 Series II Fluke Corporation 5
190-062 190-102 190-202 190-104 190-204
ScopeRecord Roll Mode
Dual or multiple input waveform storage mode, using deep memory
Source and display Input A, Input B, Dual
All channels sampled simultaneously
Any combination of inputs,
up to 4 channels
All channels sampled simultaneously
Bandwidth 20 MHz or 20 kHz, user selectable
Memory depth 30,000 data points, each holding min/max pair of information
Min/max values Min/max values are created at samples that are measured at high sample rate
ensuring capture and display of glitches
Recording modes Single sweep, continuous roll,
Start-on-Trigger (through external),
Stop-on-Trigger (through external)
Single sweep, continuous roll,
Start-on-Trigger (through any channel),
Stop-on-Trigger (through any channel)
Stop-on-trigger ScopeRecord mode can be stopped by an individual trigger event, or by an interruption of a repetitive
trigger signal, through any input channel (through External on 190-XX2 Series)
Horizontal scale Time from start, time of day
Zoom Ranges from full record overview to zoom in up to sample level, at any record length
Memory Two multiple input ScopeRecord waveforms can be saved internally for later recall and analysis
Direct storage on external flash memory drive through USB host port
ScopeRecord Roll mode sample rate and recording timespan
Time base range 5 ms/div ~ 2 min/div
Recorded timespan 6 sec ~ 48 hr
Time/division in ‘view all’ mode 0.5 s/div ~ 4 h/div
Glitch capture 8 ns
Sample rate 125 MS/s
Resolution 200 μsec ~ 4.8 sec
Trendplot Recording
Multiple channel electronic paperless recorder
Graphically plots, displays and stores results of up to four automatic scope measurements or a DMM-reading over time
Source and display Any combination of scope measurements, made on any of the input channels, or DMM reading
(2-channel instruments)
Memory depth 18,000 points (sets) per measurement
Each recorded sample point contains a minimum, a maximum and an average value,
plus a date- and timestamp
Ranges Normal view: 5 s/div to 30 min/div
In view-all mode: 5 min/div to 48 hr/div (overview of total record)
Recorded time span Up to 22 days, with a resolution of 102 seconds
Recording mode Continuous recording, starting at 5 s/div with automatic record compression
Measurement speed 3 automatic measurements per second or more
Horizontal scale Time from start, time of day
Zoom Up to 64x zoom-out for full record overview, up to 10x zoom-in for maximum detail
Memory Two multiple input TrendPlot records can be saved internally for later recall and analysis
Direct storage on external flash memory drive through USB host port
Cursor measurements – all recorder modes
Source Any waveform trace in any waveform display mode (Scope, ScopeRecord or TrendPlot)
Dual vertical lines Cursors may be used to identify Min, Max or Average value of any datapoint in a record, with time
between cursors, time from start or absolute time
Recorder Modes
6 Fluke Corporation ScopeMeter 190 Series II
190-062 190-102 190-202 190-104 190-204
Input voltage range
Rated maximum floating voltage CAT III 1000V/CAT IV 600V
(maximum voltage between any contact and earth-ground voltage level)
Maximum probe voltage CAT III 1000V/CAT IV 600V
(maximum voltage between standard 10:1 probe tip and reference lead)
Maximum BNC input voltage CAT IV 300 V
(maximum voltage on BNC input directly)
Maximum voltage on meter input CAT III 1000V/CAT IV 600V
(safety designed banana input connectors)
Memory save and recall
Memory locations (internal) 15 waveform memories plus 2 recording memories
15 waveform memory locations Stores Scope-trace waveform data (2 or 4 traces each) plus screen-copy plus corresponding setup
Two recording memories Each may contain:
a 100 Screen Replay sequence, or
a ScopeRecord Roll-mode recording (2 or 4 traces), or
a TrendPlot recording of up to 4 measurements
External data storage On PC, using FlukeView Software, or
Direct storage on external flash memory drive (maximum 2 GB) through USB host port
Screencopies On PC, using FlukeView Software, or
Internally (in instrument) which can be copied on to external flash memory drive as .BMP-file, through
USB host port
Volatility Measurement data is initially stored in RAM, which is maintained by the main battery with a 30 seconds
back-up when battery is exchanged
When storing data, this is written in non-volatile flash-ROM
Real-time clock Provides date and time stamp information for ScopeRecord, for 100 Screen Replay sequences and for
TrendPlot recordings
Case
Design Rugged, shock-proof with integrated protective holster. Handstrap and hangstrap included as standard
Kensington lock supported to lock down instrument when left unattended
Drip and dust proof IP 51 according to IEC529
Shock and vibration Shock 30 g, vibration (sinusoidal) 3 g according to MIL-PRF-28800F Class 2
Display size 127 mm x 88 mm (153 mm/6.0 in diagonal) LCD
Resolution 320 x 240 pixels
Contrast and brightness User adjustable, temperature compensated
Brightness 200 cd/m2 typ. using power adapter, 90 cd/m2 typical using battery power
Mechanical data
Size 265 mm x 190 mm x 70 mm (10.4 in x 7.5 in x 2.8 in)
Weight (including battery) 2.1 kg (4.6 lb) 2.2 kg (4.8 lb)
Power
Line power Mains adapter/battery charger BC190 included, version depending of country
Battery power Re-chargeable double capacity Li-Ion battery (included). Battery swappable through easily accessible
battery door at the rear of the instrument
Battery type (incl.) and capacity
[+opt. battery]
BP290; 2400 mAh
[BP291 (4800 mAh) optional]
BP291; 4800 mAh
Battery charge indicator Battery has built-in status indicator for use with external charger, next to battery status indicator on
instrument screen
Battery operating time
(with backlight low)
Up to four hours using BP290 (included),
Up to eight hours using BP291 (optional)
Up to seven hours using BP291 (included)
Battery charging time 2½ hours using BP290; 5 hours using BP291 Five hours BP291
Battery power saving functions Auto ‘power down’ with adjustable power down time; Auto ‘Display off’ with adjustable power down
time; On-screen battery power indicator
Safety
Compliance EN61010-1-2001, Pollution Degree 2;
CAN/CSA C22.2, No. 61010-1-04, with approval;
UL61010B;
ANSI/ISA-82.02.01
General Specifications
ScopeMeter 190 Series II Fluke Corporation 7
190-062 190-102 190-202 190-104 190-204
Environmental
Operating temperature 0 °C ~ +40 °C; +40 °C ~ +50 °C excl. battery
Storage temperature -20 °C ~ +60 °C
Humidity +10 °C ~ +30 °C: 95 % RH non-condensing;
+30 °C ~ +40 °C: 75 % RH non-condensing;
+40 °C ~ +50 °C: 45 % RH non-condensing.
Maximum operating altitude Up to 2,000 m (6666 ft) for CAT IV 600 V, CAT III 1000 V;
up to 3,000 m (10,000 ft) for CAT III 600 V, CAT II 1000 V
Maximum storage altitude 12 km (40,000 ft)
Electro-Magnetic-Compatibility (EMC) EN 61326 (2005-12) for emission and immunity
Interfaces Two USB-ports provided. Ports are fully insulated from instrument’s floating measurement circuitry
USB-host port directly connects to external flash memory drive (up to 2 GB) for storage of waveform
data, complete datasets in which data and setup information is included, instrument settings and
screen copies
A mini-USB-B is provided which allows for interconnection to PC for remote control and data transfer
under PC-control
Probe calibration output Dedicated probe-cal output with reference contact provided, fully insulated from any measurement
input channel
Warranty Three years (parts and labor) on main instrument, one year on accessories
Included accessories
Battery charger/mains adapter BC190
Li-Ion battery pack BP290 (2400 mAh) BP291 (4800 mAh)
Voltage probe sets. Each set includes
ground lead, hook clip, ground spring
and probe tip insulation sleeve.
VPS410 (one red, one blue) VPS410 (one red, one grey, one blue,
one green)
Test leads TL175 (one red, one black) with test pins (N/A)
Other Handstrap affixed to instrument; hangstrap (user selectable for left- or righthand use);
multi-language users manuals on CD-ROM; FlukeView® demo package (with restricted functionality);
USB interface cable for PC connectivity
8 Fluke Corporation ScopeMeter 190 Series II
Fluke Corporation
PO Box 9090, Everett, WA 98206 U.S.A.
Fluke Europe B.V.
PO Box 1186, 5602 BD
Eindhoven, The Netherlands
For more information call:
In the U.S.A. (800) 443-5853 or
Fax (425) 446-5116
In Europe/M-East/Africa +31 (0) 40 2675 200 or
Fax +31 (0) 40 2675 222
In Canada (800)-36-FLUKE or
Fax (905) 890-6866
From other countries +1 (425) 446-5500 or
Fax +1 (425) 446-5116
Web access: http://www.fluke.com
©2010-2011 Fluke Corporation.
Specifications subject to change without notice.
Printed in U.S.A. 4/2011 3801685B A-EN-N
Modification of this document is not permitted
without written permission from Fluke Corporation.
Fluke. Keeping your world
up and running.®
Ordering Information
Models
Fluke 190-204 Color ScopeMeter, 200 MHz, 4 channels
Fluke 190-204/S Color ScopeMeter, 200 MHz, 4 channels, with SCC-290 kit included
Fluke 190-104 Color ScopeMeter, 100 MHz, 4 channels
Fluke 190-104/S Color ScopeMeter, 100 MHz, 4 channels, with SCC-290 kit included
Fluke 190-202 Color ScopeMeter, 200 MHz, 2 channels plus DMM/Ext.input
Fluke 190-202/S Color ScopeMeter, 200 MHz, 2 channels plus DMM/Ext.input, with
SCC-290 kit included
Fluke 190-102 Color ScopeMeter, 100 MHz, 2 channels plus DMM/Ext.input
Fluke 190-102/S Color ScopeMeter, 100 MHz, 2 channels plus DMM/Ext.input, with
SCC-290 kit included
Fluke 190-062 Color ScopeMeter, 60 MHz, 2 channels plus DMM/Ext.input
Fluke 190-062/S Color ScopeMeter, 60 MHz, 2 channels plus DMM/Ext.input, with
SCC-290 kit included
Accessories
C290 Hard shell protective carrying case for 190 Series II
HH290 Hanging Hook for 190 Series II instruments
SCC290 FlukeView Software package (full version) and C290 Carrying Case kit
for 190-series II
VPS410-R Voltage Probe set, 10:1, 300 MHz, one set red
VPS410-G Voltage Probe set, 10:1, 300 MHz, one set grey
VPS410-B Voltage Probe set, 10:1, 300 MHz, one set blue
VPS410-V Voltage Probe set, 10:1, 300 MHz, one set green
VPS420-R High voltage probe set 150 MHz, 100:1, CAT III 2000V (1000V to earth)
BC190 Mains adapter/battery charger
EBC290 External battery charger for BP290 and BP291
TL175 TwistGuard™ safety designed Test Leads set (1 red, 1 black)
BP290 Li-Ion battery pack, 2400 mAh
BP291 Li-Ion battery pack, 4800 mAh
SW90W FlukeView Software for Windows (full version)
AS400 Accessory Extension Set
RS400 Probe Accessory Replacement Set
Mouser Electronics
Authorized Distributor
Click to View Pricing, Inventory, Delivery & Lifecycle Information:
Fluke:
FLUKE-190-062/AM FLUKE-190-062/AM/S FLUKE-190-102/AM FLUKE-190-102/AM/S FLUKE-190-202/AM
FLUKE-190-202/AM/S