• North America Tel: 800.366.2266 • Europe Tel: +353.21.244.6400
• India Tel: +91.80.4155721 • China Tel: +86.21.2407.1588
Visit www.macomtech.com for additional data sheets and prod uct information.
M/A-COM Technology Solutions Inc. and its affiliates reserve the right to make
changes to the product(s) or information contained herein without notice.
1
Two-Way Power Dividers,
1 - 100 MHz and 40 - 400 MHz
Rev. V3
MTH-50 / MTV-50
ADVANCED: Data Sheets contain information regarding a product M/A-COM Technology Solutions
is considering for development. Performance is based on target specifications, simulated results,
and/or prototype measurements. Commitment to develop is not guaranteed.
PRELIMINARY: Data Sheets contain information regarding a product M/A-COM Technology
Solutions has under development. Performance is based on engineering tests. Specifications are
typical. Mechanical outline has been fixed. Engineering samples and/or test data may be available.
Commitment to produce in volume is not guaranteed.
Features
• Ideal for High Density Packaging
• High Isolation: 30 dB Min.
• VSWR: 1.3:1 Max.
• Impedance: 50 Ohms Nominal
• Maximum Power Rating or Input Power: 1 Watt
Max.
• Internal Load Dissipation: 0.05 Watts Max.
• MIL-STD-883 Screening Available
Description
A Power Divider is ideally a lossless reciprocal
device which can also perform vector summation of
two or more signals and thus is sometimes called a
power combiner or summer.
TO-5-1
Pin Configuration
Pin No. Function Pin No. Function
A Out C Out
B In
MTH-50 Electrical Specifications1: TA = -55°C to +85°C
Parameter Test Conditions Frequency Units Min Typ Max
Frequency — 1 - 100 MHz — — —
Insertion Loss Less Coupling 1 - 100 MHz dB — — 0.5
Isolation — 1 - 100 MHz dB 30 — —
Amplitude Balance — 1 - 100 MHz dB — — 0.1
Phase Balance — 1 - 100 MHz ° — — 1.0
VSWR — 1 - 100 MHz Ratio — — 1.3:1
MTV-50 Electrical Specifications1: TA = -55°C to +85°C
Parameter Test Conditions Frequency Units Min Typ Max
Frequency — 40 - 400 MHz MHz — — —
Insertion Loss Less Coupling 40 - 400 MHz dB — — 0.6
Isolation — 40 - 400 MHz dB 30 — —
Amplitude Balance — 40 - 400 MHz dB — — 0.2
Phase Balance — 40 - 400 MHz ° — — 2.0
VSWR — 40 - 400 MHz Ratio — — 1.3:1
1. All specification apply with 50 ohm source and load impedance.