Eaton brings you the comprehensive
MEDC and FHF signalling, alarm and
notification range for hazardous and
harsh environments
CROUSE-HINDS
SERIES
Signalling and alarms
Product overview
Part of our wider solution for harsh and hazardous environments
PA / GA
Designed, engineered and
manufactured according to individual
project specifications and industry
regulations. The SonixTM system uses
the latest in digital technology and
can be integrated with a wide range of
Eaton products to ensure the
integrity of your assets in even the most
demanding of environments.
CCTV
Cutting edge technology from our
market leading brands of HernisTM and
Oxalis.
With the widest range of camera
stations and system solutions from a
single manufacturer, we have the
products and experience to meet
todays demanding surveillance and
security needs.
With products available that are
explosion protected or weatherproof,
analogue or IP, fixed, dome or PTZ, our
experience and proven reliability can
meet your specification requirements.
Signalling and alarms
Our MEDC and FHF product lines offer
a wide range of products specifically
designed for harsh environments where
there is a risk of explosion for both
onshore and offshore applications. This
range of products including manual
activation, visual and audible alarms,
and loudspeakers, can be connected to
IMCOS or SonixTM delivering the best
combination of performance and safety.
IMCOS
One of only a few systems in the world
to have seven different type approvals.
IMCOS provides the solutions you
need both Onshore and Offshore. The
following applications demonstrate the
ability to provide a single solution.
With IMCOS and our latest
developments in technology, we are
able to provide a single network which
provides reduced cable architecture.
Our LAN systems are able to share a
highway of information and resources,
interlinking video, voice and data with
our VoIP telephones, IPTV streaming,
CCTV, PA/GA and Intercom systems
through one fibre or copper backbone.
Mining control and
communications
Our FHF-BT business has over 100 years
of experience in mining applications.
Today the team delivers intrinsically safe
turnkey automation and
communications solutions on a global
basis. Our solutions based offering
includes shaft signalling and
communications, loudspeaker and
conveyer belt control, data
transmission, radio systems and various
automation systems.
Telecommunications
Whether a traditional analogue,
digital, VoIP or Hybrid telephone
system is what you require, we can
provide the solution you need with our
IMCOS PABX system. Together with a
wide range of telephones we can
provide standard, weatherproof,
explosion protected and IP phones.
2EATON signalling and alarms product overview
Eaton has brought together the most
recognised names in oil and gas, such as
MEDC and FHF, to be able to provide you
with a comprehensive product offering
of specialist, high quality equipment
designed to make harsh and hazardous
locations a safer, more efficient working
environment. Eaton offer a specialised
team of highly qualified staff to ensure
all aspects of engineering, design and
configuration within your project are
fulfilled - from initial stages of concept
through to commissioning.
The MEDC signalling and alarm range has been
relied upon by the oil & gas industry to deliver
high quality, innovative products for many
years. With an extensive range of worldwide
certifications including ATEX and IECEx, Eaton
has the capability to deliver industry leading
solutions designed to meet customer and project
specifications.
Additionally, Eaton can provide a world class
range of FHF telephone equipment designed
for harsh and hazardous environments.
Decades of experience in the fields of industrial
communication and signalling, together with our
specialist expertise, ensure that customers are
provided with the most reliable and up to date
technology available.
Proven solutions for harsh and hazardous environments
This overview contains concise
information on Eatons range of MEDC
and FHF signalling and alarm products for
use in potentially explosive atmospheres,
harsh industrial and marine environments.
To use this guide, refer to the product
group of interest, read through the brief
information and select the specific
product for your application.
For more detailed information and
ordering codes visit our website
www.crouse-hinds.com/ hac where a
detailed datasheet can be downloaded.
Or alternatively contact one of our sales
offices for a full catalogue, all details can
be found on the back page.
Hazardous area guide .............................. 4
Hazardous area manual alarm call points ............. 6
Hazardous area beacons ............................ 10
Industrial beacons ................................. 20
Hazardous area sounders ........................... 26
Industrial sounders ................................ 32
Hazardous area loudspeakers ....................... 40
Industrial loudspeakers ............................. 44
Hazardous area status lights and combination units .... 48
Industrial status lights and combination units ......... 54
Hazardous area telephones and accessories .......... 58
Industrial telephones and accessories ................ 64
Hazardous area control and distribution .............. 70
Hazardous area US products ........................ 76
How to use this overview
Contents
To see the complete
Hazardous Area
Communication range,
please visit
www.crouse-hinds.com/hac
3EATON signalling and alarms product overview
European & IEC Classification Definition of zone or division North American Classification
Zone 0 (gases)
Zone 20 (dusts)
An area in which an explosive mixture is continuously present or present
for long periods
Class I Division 1 (gases)
Class II Division 1 (dusts)
Zone 1 (gases)
Zone 21 (dusts)
An area in which an explosive mixture is likely to occur in normal operation Class I Division 1 (gases)
Class II Division 1 (dusts)
Zone 2 (gases)
Zone 22 (dusts)
An area in which an explosive mixture is not likely to occur in normal operation
and if it occurs it will exist only for a short time
Class I Division 2 (gases)
Class II Division 2 (dusts)
Class III Division 1 (fibres)
Class III Division 2 (fibres)
Gas groups, dusts and fibres
There are two main gas groups and one dust group,
Group I – Mining only and Group II – Surface Industries.
These categories are used in European and IEC. groupings.
Group I is concerned only with underground mining where methane
and coal dust are present.
Group II gases occurring in surface industries, are sub-grouped
according to their volatility. This enables electrical equipment to be
designed to less onerous tolerances if it is to be used with the least
volatile gases.
Group III explosive dusts occurring in surface industries and are sub
grouped according to their volatility.
Temperature
To guard against hot surfaces igniting gases, all electrical equipment
intended for use in Potentially Explosive Atmospheres is classified
according to the maximum surface temperature it will reach in
service (normally based on a surrounding ambient temperature of 40°C
(102°F).
ATEX
After 1st July 2003, the ATEX directive came into force and is a
mandatory requirement for all equipment intended for use in
Potentially Explosive Atmospheres within the E.U. All relevant MEDC
equipment is covered by the date it comes into force and many are
already certified. It should be noted also that MECHANICAL
equipment is covered by the ATEX directive so for the first time items
such as gearboxes will have to carry ATEX certification.
The equipment coding will be as the current practice plus an additional code
as follows:
Ex II 2 GD i.e.
Ex – Explosionproof in accordance with ATEX.
II – Group II surface industries
2 – Category 2 equipment (suitable for use in Zone 1)
note: Category 1 is suitable for Zone 0.
Category 3 is suitable for Zone 2.
G – suitable for atmospheres containing gas
D – suitable for atmospheres containing dust
Equipment will be CE marked when certified to ATEX.
Typical gas/material European/I.E.C.
Gas Group North American
Gas Group
Methane I -
Acetylene IIC A
Hydrogen IIC B
Ethylene IIB C
Propane IIA D
Metal dust - E
Coal dust - F
Grain dust - G
Temperature Classification Maximum Surface
TemperatureEuropean/I.E.C. North American
T1 T1 450° C
T2 T2
T2A
T2B
T2C
T2D
300° C
280° C
260° C
230° C
215° C
T3 T3
T3A
T3B
T3C
200° C
180° C
165° C
160° C
T4 T4
T4A
135° C
120° C
T5 T5 100° C
T6 T6 85° C
Hazardous area guide
International Europe U.S.A.
General Recommendations IEC60079-14 EN60079-14 N.E.C. Chapter 5
Classification of Hazardous Areas IEC60079-10 EN60079-10 N.E.C. Chapter 5
Inspection and Maintenance of Electrical Equipment IEC60079-17 EN60079-17 -
Requirements for Flameproof Enclosures IEC60079-14 EN60079-14 N.E.C. Chapter 5
Requirements for Intrinsically Safe Equipment IEC60079-14 EN60079-14 N.E.C. Chapter 5
Requirements for Increased Safety Equipment IEC60079-14 EN60079-14 N.E.C. Chapter 5
Requirements for Purged and Pressurised Equipment IEC60079-14 EN60079-14 N.E.C. Chapter 5
Requirements for Non-Sparking Equipment IEC60079-14 EN60079-14 -
Selection, installation and maintenance
of electrical equipment intended for use
in potentially explosive atmospheres
International and national standards are
published giving details of requirements
for the safe use of electrical equipment in
potentially explosive atmospheres as
follows:
Definition
Potentially explosive atmospheres exist where there is a risk of explosion due to mixtures of gas/air, vapour/air, dust/air or other
flammable combinations. Where electrical equipment has to be used in these areas, it must be so designed and constructed such that it does
not create sources of ignition capable of igniting these mixtures.
Area classification
Process plants are divided into Zones (European and IEC method) or Divisions (North American method) according to the likelihood of a poten-
tially explosive atmosphere being present. Note: North American legislation now allows Zones to be used to classify areas, where this practice
is used it follows the IEC Zone method.
This information is intended as a guide only and further expert guidance should be sought before placing into service,
maintaining or repairing any item of equipment in a potentially explosive atmosphere.
4EATON signalling and alarms product overview
Types of electrical equipment suitable for use in potentially explosive gas, vapour
and mist atmospheres Typical EPL
Area of use
Designation
Standard
USA
Area of use
Designation
Standard
Different techniques are used to prevent electrical equipment from igniting explosive atmospheres. There are
restrictions on where these different types of equipment can be used as follows:
Flameproof Enclosure – An enclosure used to house electrical equipment, which when subjected to an internal
explosion will not ignite a surrounding explosive atmosphere. Ex da
Ex db
Ex dc
IEC/EN 60079-1
Zones
0
1
2
Class I
Divisions 1 & 2
UL1203
Intrinsic Safety – A technique whereby electrical energy is limited such that any sparks or heat generated by
electrical equipment is sufficiently low as to not ignite an explosive atmosphere.
Ex ia
Ex ib
Ex ic
IEC/EN 60079-11
Zones
0
1
2
Class I
Divisions 1 & 2
UL913
Increased Safety – This equipment is so designed as to eliminate sparks and hot surfaces capable of igniting
an explosive atmosphere. Ex e
IEC/EN 60079-7
Zones
1
Purged and Pressurised – Electrical equipment is housed in an enclosure which is initially purged to remove any
explosive mixture, then pressurised to prevent ingress of the surrounding atmosphere prior to energisation. Ex pxb
Ex pyb
Ex pzc
IEC/EN 60079-2
Zones
1
1
2
Class I
Div 1
Div 1
Div 2
NFPA496
Encapsulation – A method of exclusion of the explosive atmosphere by fully encapsulating the electrical
components in an approved material. Ex ma
Ex mb
Ex mc
IEC/EN 60079-18
Zones
0
1
2
Oil Immersion – The electrical components are immersed in oil, thus excluding the explosive atmosphere from
any sparks or hot surfaces.
Ex o
IEC/EN 60079-6
Zones
1
Class I
Divisions 1 & 2
Powder Filling – Equipment is surrounded with a fine powder, such as quartz, which does not allow the
surrounding atmosphere to come into contact with any sparks or hot surfaces. Ex q
IEC/EN 60079-5
Zones
1
Non-sparking – Sparking contacts are sealed against ingress of the surrounding atmosphere, hot surfaces are
eliminated. Ex n
IEC/EN 60079-15
Zones
2
Optical Radiation - Protection of equipment and transmission systems using optical radiation
Op pr
Op sh
Op is
IEC/EN 60079-28
Zones
1
1
2
Div 1
Div 1
Div 2
Equipment for combustible dust Typical EPL
Area of use
Designation
Standard
USA
Area of use
Designation
Standard
Enclosure - Equipment dust ignition protection by enclosure
Ex ta
Ex tb
Ex tc
IEC/EN 60079-31
Zones
20
21
22
Class II
Division 1 & 2
UL1263
Intrinsic Safety
Ex ia
Ex ib
Ex ic
IEC/EN 60079-11
Zones
20
21
22
Class II
Division 1 & 2
UL913
Encapsulation
Ex ma
Ex mb
Ex mc
IEC/EN 66079-18
Zones
20
21
22
Pressurised
Ex Pxb
Ex Pyb
Ex Pzc
IEC/EN 60079-2
Zones
21
21
22
Class II
(PX) Div 1
(PY) Div 1
(PZ) Div 2
Eaton advise that all Explosion-proof electrical equipment is maintained, by suitably trained personnel, in accordance with the
Manufacturers’ recommendations.
Any spare parts used should be purchased from the original Manufacturer and repairs should be carried out by the Manufacturer or
under their supervision, in order that the item remains in conformance with the certification documents.
5EATON signalling and alarms product overview
Eaton provide a range of manual alarm call points specifically
designed for the purpose of raising an alarm in the case of an
emergency in a hazardous area.
The call points can be made from a selection of materials depending
on project specification. This includes glass reinforced polyester (GRP),
a light weight and corrosion free material, allowing easy installation
and low maintenance cost. Stainless steel is also available which is a
heavy duty, long wearing material with an increased life span.
All of Eatons call points have a minimum IP rating of IP66, with the
majority also including IP67, and can be certified to one of our
worldwide accreditations, including ATEX and IECEx. There are also
options for the inclusion of LED status indicators and addressable
location (or address) within the unit and many can be painted a
variety of colours to the customer’s specification.
Hazardous area manual alarm call points
SM87PB SM87BG PH1 PB
BG BG2 BG3 Ex-Fire Alarm Switch
Page 7 Page 7 Page 7 Page 8
Page 8 Page 8 Page 9 Page 9
6EATON signalling and alarms product overview
SM87PB
Ex d & Ex ia Push button call points
Certification ATEX, IECEx, cULus, ULC, CSA, TR CU, CQST,
INMETRO, CCOE
Area classification Zone 0, 1, 2, 20, 21, 22, weatherproof
ATEX/IEC classification Ex II 2 GD, Ex d IIC T5/T6 Gb
Ex tb IIIC T100°C/T85°C Db
Ex II 1 GD, Ex ia IIC T4 Ga
UL/NEC classification Class 1, Div. 1, Groups C, D
(CSA Ex ia also includes groups A & B )
Approvals SIL2, Russian fire approval, ABS
Certified temperature -55°C to +70°C*
Ingress protection IP66, IP67 & IP68, NEMA 4X & 6
Material Stainless steel or alloy
Entries Up to 4 x M20, M25, ½” NPT or ¾” NPT
Weight Stainless: 3.8kg. Alloy: 2.5kg
Switches 2 pole c/o (Up to 4 pole c/o available)
Options Switch action, labels, LED, EOL and series
resistors, diodes, 3 or 4 pole switches, colour
SM87BG
Ex d & Ex ia Break glass call points
Certification ATEX, IECEx, CSA, TR CU, CQST, INMETRO, CCOE
Area classification Zone 0, 1, 2, 20, 21, 22, weatherproof
ATEX/IEC classification Ex II 2 GD, Ex d IIC T5/T6 Gb
Ex tb IIIC T100°C/T85°C Db
Ex II 1 GD, Ex ia IIC T4 Ga
UL/NEC classification Class 1, Div. 1, Groups C, D
(CSA Ex ia also includes groups A, B)
Approvals Russian fire approval
Certified temperature -55°C to +70°C*
Ingress protection IP66, 67, NEMA 4X & 6
Material Stainless steel or alloy
Entries Up to 4 x M20, M25, ½” NPT or ¾” NPT
Weight Stainless: 3.8kg. Alloy: 2.5kg
Switches 2 pole c/o (Up to 4 pole c/o available)
Options Switch action, labels, LED, EOL and series
resistors, diodes, 3 or 4 pole switches, colour
*Model dependent
PH1
Ex d Pull handle call point
Certification ATEX, IECEx, cULus
Area classification Zone 1, 2, 21, 22 & weatherproof
ATEX/IEC classification Ex II 2 GD, Ex d IIC T6 Gb, Ex tb IIIC T85°C Db
UL/NEC classification Class I, Div. 1, Groups B, C, D
Class I, Div. 2, Groups A, B, C, D
Certified temperature -55°C to +70°C*
Ingress protection IP66, 67, NEMA 4X & 6
Material Corrosion free GRP (UL Class I, Div. 1
Inner Cover: 316 stainless steel)
Entries Up to 2 x M20, M25, ½” NPT or ¾” NPT
Weight UL Class I, Div 2/ATEX/IECEx/UW: 2.6Kg
UL Class I, Div. 1: 3.8Kg
Switches 1 or 2 pole c/o
Options EOL and series resistors, diodes, labels, body
colour
mm ±2
200mm ±2
mm ±
Hazardous area manual alarm call points
7EATON signalling and alarms product overview
PB
Ex de & Ex ia Push button call points
Certification ATEX, IECEx, cULus, CSA, TR CU, CQST, INMETRO,
CCOE
Area classification Zone 0, 1, 2, 20, 21, 22, weatherproof
ATEX/IEC classification Ex II 2 GD,Ex de(mb) IIC T4/T6*Ex tb IIIC T120°C Db
Ex II 1 GD, Ex ia IIC T4 GaEx ia IIIC T135°C Da
UL/NEC classification Class I, Div. 2, Groups A, B, C, D
Class II, Div. 2, Groups F, G
Approvals SIL2, Russian fire approval, ABS
Certified temperature -50°C to +70°C*
Ingress protection IP66, 67, NEMA 4X & 6
Material Corrosion free GRP
Entries Up to 4 x M16, M20 or ½” NPT
Weight 1.2kg*
Switches 1 or 2 pole c/o
Options Labels, LED, EOL and series resistors, diodes, Earth
continuity, switch action, number of terminals,
colour
Hazardous area manual alarm call points
BG2
Ex de & Ex ia Break glass call points
Certification ATEX
Area classification Zone 0, 1, 2, 20, 21, 22, weatherproof
ATEX/IEC classification Ex II 2 G, Ex de (mb) IIC T4/T6*
Ex II 1 GD, Ex ia IIC T4 Ga , Ex ia IIIC T135°C Da
Certified temperature -40°C to +70°C*
Ingress protection IP66 & IP67
Material Corrosion free GRP
Entries 2 x M20
Weight 1.2kg*
Switches 1 pole c/o
Options EOL and series resistors, diodes, lift flap
*Model dependent
120mm ± 2
126mm ± 2
BG
Ex de & Ex ia Break glass call points
Certification ATEX, IECEx, cULus, TR CU, CQST, INMETRO, CCOE
Area classification Zone 0, 1, 2, 20, 21, 22, weatherproof
ATEX/IEC classification Ex II 2 G, Ex de (mb) IIC T4/T6*
Ex II 1 GD, Ex ia IIC T4 Ga, Ex ia IIIC T135°C Da
UL/NEC classification Class I, Div. 2, Groups A, B, C, D
Approvals SIL2, Russian fire approval, CCCF
Certified temperature -50°C to +70°C *
Ingress protection IP66, 67, NEMA 4X & 6
Material Corrosion free GRP
Entries Up to 4 x M16, M20 or ½” NPT
Weight 1.2kg*
Switches 1 or 2 pole c/o
Options Labels, switches, LED, Lift flap, EOL and series
resistors, diodes, Earth continuity, plastic element,
break glass hammer, colour
120mm ±2
126mm ±2
120mm ±2
126mm ±2
8EATON signalling and alarms product overview
BG3
Ex ia Break glass call points
Certification ATEX
Area classification Zone 0, 1, 2, 20, 21, 22, weatherproof
ATEX/IEC classification Ex II 1 G, EEx ia IIC T4
Certified temperature -55°C to +55°C
Ingress protection IP66 & IP67
Material Corrosion free GRP
Entries 2 x M20
Weight 0.5kg
Switches 1 or 2 pole c/o
Options Labels, EOL and series resistors, diodes,
polycarbonate or stainless steel lift flap, LED,
double switch, plastic element, colour
Hazardous area manual alarm call points
Ex-Fire Alarm Switch
Ex de Break glass & push button call point
Certification ATEX
Area classification Zone 1, 2, 21, 22
ATEX/IEC classification Ex II 2 GD, Ex de mb IIC T5/T6 Gb
Ex tb IIIC T100 °C Db
Approvals EN54-11, VDS
Certified temperature -55°C to +70°C*
Ingress protection IP66
Material Corrosion free GRP
Entries 1 x M16 & 1 x blank plug M16
Weight 1.8kg
Switches 2 pole c/o
Options Resistors, colour
155mm
163mm 139mm
Ex Fire alarm Switch LD
*Model dependent
9EATON signalling and alarms product overview
Eatons range of beacons, including flashing, steady-state indicators and rotating
units, provide solutions for potentially explosive and harsh environmental
conditions. These may be used to warn of potential hazards or indicate the status of
plant items, gas and oil leaks and evacuation alerts.
The signals can be operated as stand-alone units or be incorporated into a wider
system, such as a fire panel. Many units can also be customised with a choice of lens
colours and can be painted to customer specification.
Eaton offer a range of LED beacons, which have the added benefit of low
energy consumption, an increased lifespan and an option of flash patterns.
LD15 dSLB20-LED Expertline LED SM87LED ActiveLine GH5 SM87HXB
XB11 XB9 BZ2/BD22 BDK22 XB10 dSLB 20
XB15 XB4 XB12 XB8 XB16 TH12
SM87 LU1/LU3 FL4 & FB4 FB11 & FL11 FL12 & FB12 FB15
Page 12 Page 12 Page 12 Page 13 Page 13 Page 13
Page 14 Page 14 Page 14 Page 15 Page 15 Page 15
Page 16 Page 16 Page 16 Page 17 Page 17 Page 17
Page 18 Page 18 Page 19 Page 19 Page 19
Hazardous area beacons
10 EATON signalling and alarms product overview
Eaton, pioneers in the latest
technology, are pleased to
announce the evolution of the
XB15 beacon range
XB15 – 5J, 10J & 15J
In an emergency situation in a potentially explosive environment,
it is paramount to have an effective warning system that you can
depend on. Since its launch 10 years ago, the XB15 has proven to
be the product of choice in the fire, flame, gas and telecom
integration markets whenever strength, reliability and ease of
installation are required.
With a glass reinforced polyester body and borosilicate glass lens,
the XB15 leads the way in signalling devices where the effects of
adverse harsh environmental conditions and extreme
temperatures of -55°C to +70°C demand the highest quality and
performance possible. The effective candlepower of the 15J unit
has been measured at 382cd, ensuring that our product will be
effective no matter what the application.
11EATON signalling and alarms product overview
Expertline LED
Ex em LED light
Certification ATEX, IECEx, cULus, TR CU, INMETRO
Area classification Zone 1, 2, 21, 22, weatherproof
ATEX/IEC classification Ex II 2G, Ex e mb [ib] IIC T4 Gb
Ex II 2D, Ex mb t IIIC IP66 T130°C Db
UL/NEC classification Class I, Div. 2, Groups A, B, C, D, T4
Class I, Zone 2, Groups IIA, IIB, IIC, T4
Approvals ICAO
Certified temperature -40°C to +65°C*
Ingress protection IP66, NEMA 4X
Material Polycarbonate
Entries 2 x M20 & 1 x blank plug M20
Weight 2.5kg
Voltage 24Vdc, 120-230Vac
Light source LED
Options LED colour, ICAO obstruction light version
185mm
299mm
Hazardous area beacons
LD15
Ex d LED beacon
Certification ATEX, IECEx, cULus, ULC, TR CU, CQST, INMETRO
Area classification Zone 1, 2, 21, 22, weatherproof
ATEX/IEC classification Ex II 2GD, Ex db IIC T5/T6 Gb
Ex tb IIIC T100°C/T85°C Db
UL/NEC classification Class I, Div. 2, Groups A*, B*, C, D
Class II, Div. 2, Groups F, G
Class I, Zone 1, AEx d IIC* & IIB, Ex d IIB
Approvals SIL1 (1oo1) & SIL2 (1oo2)
Certified temperature -55°C to +70°C
Ingress protection IP66 & IP67, NEMA 4X & 6
Material Corrosion free GRP
Entries Up to 3* x M20, M25, ½” NPT or ¾” NPT
Weight Direct: 3.5Kg. Pipe: 3.1Kg
Voltage 12-48Vdc, 110-254Vac
Light source LED
LED life 54,000 hours
Options Lens colour, lens guard, mounting, tag & duty
label, relay initiate, telephone initiate, body colour
210
2
90
1
90
1
20
1
239mm ±5
150mm
3
118mm
2
240mm
±
5
36 1 A/F
dSLB20-LED
Ex de LED beacon
Certification ATEX, IECEx, TR CU, INMETRO
Area classification Zone 1, 2, 21, 22, weatherproof
ATEX/IEC classification Ex II 2GD, Ex d e IIC T6 Gb, Ex tb IIIC T80°C Db
Approvals ICAO
Certified temperature -55°C to +55°C
Ingress protection IP66 & IP67
Material Aluminium
Entries 1x M20 and 1x blank plug M20
Weight 2kg
Voltage 24-48Vdc, 85-265Vac
Light source LED
Options LED colour
130mm
Ø110mm
210
2
90
1
90
1
20
1
239mm ±5
150mm
3
118mm
2
240mm
±
5
36 1 A/F
210
2
90
1
90
1
20
1
239mm ±5
150mm
3
118mm
2
240mm
±
5
36 1 A/F
Direct mount Pipe mount
*Model dependent
12 EATON signalling and alarms product overview
SM87LED
Ex d LED beacon
Certification ATEX, IECEx, TR CU, INMETRO, CCOE
Area classification Zone 1, 2, 21, 22, weatherproof
ATEX/IEC classification Ex II 2GD, Ex d IIC T6 Gb, Ex tb IIIC T70°C Db
Approvals SIL2, Russian fire approval
Certified temperature -55°C to +55°C
Operating temperature -20°C to +55°C
Ingress protection IP66 & IP67
Material Stainless steel or alloy
Entries Up to4 x M20 or M25
Weight Alloy: 2kg. Stainless steel: 3.8kg
Voltage 24-48Vdc
Light source LED
Options LED colour, lens guard, tag/duty label, telephone
initiate, relay initiate, EOL resistor, body colour
ActiveLine GH5
Ex nR Multicolour LED beacon
Certification ATEX
Area classification Zone 2, 22, weatherproof
ATEX/IEC classification Ex II 3G, Ex nR IIC T6 Gc
Ex II 3D, Ex tc IIIC T85°C Dc
Certified temperature -20°C to +50°C
Ingress protection IP66
Material Polycarbonate
Entries 1 x M20 & 2 x blank plug M20
Weight 1.4kg
Voltage 24Vdc, 230Vac
Light source Multicolour LED
Options Flash function, LED colour
185mm
295mm
SM87HXB
5 joule Ex d xenon beacon
Certification ATEX, IECEx, cULus, CSA, TR CU, CQST, INMETRO,
CCOE
Area classification Zone 1, 2, 21, 22, weatherproof
ATEX/IEC classification Ex II 2GD, Ex d IIC T5/T6 Gb
Ex tb IIIC T95°C/T80°C/T65°C Db
UL/NEC classification Class I, Div. 1, Groups C, D
Class I, Zone 1, Aex d IIB, Exd IIB
Approvals SIL2, Russian fire approval
Certified temperature -55°C to +70°C
Ingress protection IP66 & IP67, NEMA 4X & 6
Material Stainless steel or alloy
Entries Up to 4 x M20, M25, ½” NPT or ¾” NPT
Weight Alloy: 2.0kg. Stainless steel: 3.8kg
Voltage 24-48Vdc, 110-254Vac
Light source Xenon
Options Lens colour, lens guard, tag/duty label, telephone
initiate, relay initiate, EOL resistor, body colour
Hazardous area beacons
13EATON signalling and alarms product overview
Hazardous area beacons
XB9
5 joule Ex d xenon beacon
Certification ATEX, IECEx, TR CU, CQST
Area classification Zone 1, 2, weatherproof
ATEX/IEC classification Ex II 2G, Ex d IIC T5/T6 Gb
Approvals Russian fire approval
Certified temperature -55°C to +55°C
Ingress protection IP66 & IP67
Material Corrosion free GRP
Entries 1 x M20, PG13.5, 3m cable tail
Weight 1.6kg
Voltage 12-60Vdc, 110-254Vac
Light source Xenon
Options Flash rate, lens colour, tag/duty label, body colour
Ø81mm ±2
248mm
82mm
BZ2/BD22
15 joule Ex nR xenon beacon
Certification ATEX
Area classification Zone 2, 22, weatherproof
ATEX/IEC classification Ex II 3G, Ex nR IIC T5/T4 Gc
Ex II 3D, Ex tc IIIC T85°C Dc
Certified temperature -20°C to +50°C*
Ingress protection IP66
Material Polycarbonate
Entries 1 x M20 & 1 x blank plug
Weight 1.4kg
Voltage 12-24Vdc, 120-230Vac
Light source Xenon
Options Lens colour
185mm
299mm
XB11
5 joule Ex d xenon beacon
Certification ATEX, IECEx, cULus, TR CU, CQST, INMETRO, CCOE
Area classification Zone 1, 2, 21, 22, weatherproof
ATEX/IEC classification Ex II 2GD, Ex d IIB T4/T5/T6 Gb
Ex tb IIIC T110°C/T85°C/T70°C Db
UL/NEC classification Class I, Div. 2, Groups C, D
Class I, Zone 1, AEx d IIB, Ex d IIB
Approvals Russian fire approval, CSFM
Certified temperature -55°C to +70°C
Ingress protection IP66 & IP67, NEMA 4X & 6
Material Corrosion free GRP
Entries 2 x M20 or ½” NPT
Weight 2.5kg
Voltage 24-48Vdc, 110-240Vac
Light source Xenon
Options Flash rate, lens colour, lens guard, mounting, earth
continuity, tag/duty label, telephone initiate, body
colour
*Model dependent
14
EATON signalling and alarms product overview
XB10
10 & 15 joule Ex d(e) xenon beacons
Certification ATEX, IECEx, TR CU, INMETRO, CCOE
Area classification Zone 1, 2, weatherproof
ATEX/IEC classification Ex II 2G, Ex d IIB T4 Gb, Ex II 2G, Ex de IIB T4 Gb
Approvals Russian fire approval
Certified temperature 10 joule: -55°C to +65°C*
15 joule: -55°C to +50°C*
Ingress protection IP66 & IP67
Material Corrosion free GRP
Entries Ex d: Up to 2 x M20, PG13.5
Ex de: 3 x M20
Weight Ex d: 2.8kg. Ex de: 3.6kg
Voltage 24-48Vdc, 110-254Vac
Light source Xenon
Options Tube energy, lens colour, tag/duty label, telephone
initiate, earth continuity, cable tail, body colour
299mm±4
Ø122mm±2
357mm±5
dSLB 20
5 & 15 joule Ex de xenon beacons
Certification ATEX, IECEx, TR CU, INMETRO
Area classification Zone 1, 2, 21, 22, weatherproof
ATEX/IEC classification Ex II 2GD, Ex d e IIC T5/T6 Gb
Ex tb IIIC T80°C/T95°C Db
Certified temperature -55°C to +55°C
Ingress protection IP66 & IP67
Material Aluminium
Entries 1x M20 & 1 x blank plug M20
Weight 2kg
Voltage 12-80Vdc, 115-230Vac
Light source Xenon
Options Tube energy, lens colour
Hazardous area beacons
BDK22
5 joule Ex td xenon beacon
Certification ATEX
Area classification Zone 22, weatherproof
ATEX/IEC classification Ex II 3D, Ex tc IIIB T85°C Dc
Certified temperature -20°C to +50°C
Ingress protection IP54
Material Aluminium
Entries 1x M20
Weight 0.7kg
Voltage 24vdc, 230Vac
Light source Xenon
Options Lens colour
105
130mm
135mm
*Model dependent
Ø110mm
15EATON signalling and alarms product overview
XB4
21 joule Ex d(e) xenon beacon
Certification ATEX, IECEx, cULus, TR CU, CCOE
Area classification Zone 1, 2, 21, 22, weatherproof
ATEX/IEC classification Ex II 2GD, Ex d IIC T4/T5/T6 Gb
Ex tb IIIC T135°C/T100°C/T85°C Db
Ex II 2GD, Ex de IIC Ex tD A21 T4/T5
UL/NEC classification Class I, Div. 1, Groups C, D
Class I, Zone 1, Groups IIB & IIA
Approvals Russian fire approval
Certified temperature -55°C to +70°C
Ingress protection IP66 & IP67, NEMA 4X & 6
Material Stainless steel or alloy
Entries Up to 4* x M20, M25, ½” NPT or ¾” NPT
Weight Alloy: 6.6kg -7.6kg. Stainless steel: 15kg - 16kg
Voltage 24-110Vdc, 110-254Vac
Light source Xenon
Options Flash rate, telephone initiate, relay initiate, lens
guard, lens colour, tag/duty label, body colour
XB12
21 joule Ex d xenon beacon
Certification ATEX, IECEx, cULus, TR CU, CQST, INMETRO, CCOE
Area classification Zone 1, 2, weatherproof
ATEX/IEC classification Ex II 2G, Ex d IIB T4/T5/T6 Gb
UL/NEC classification Class I, Div. 2, Groups C, D
Class I, Zone 1, AEx d IIB, Ex d IIB
Approvals Russian fire approval, CSFM, UL Marine
Certified temperature -55°C to +70°C
Ingress protection IP66 & IP67, NEMA 4X & 6
Material Corrosion free GRP
Entries 2 x M20 or ½” NPT
Weight 7.0kg
Voltage 24Vdc, 110-240Vac
Light source Xenon
Options Body & lens colour, lens guard, tag & duty labels,
telephone initiation, flash rate, mounting method,
earth continuity
Hazardous area beacons
*Model dependent
XB15
5, 10 & 15 joule Ex d xenon beacons
Certification ATEX, IECEx, cULus, ULC, TR CU, CQST, INMETRO,
CCOE
Area classification Zone 1, 2, 21, 22, weatherproof
ATEX/IEC classification Ex II 2GD, Ex db IIC T4/T5/T6 Gb
Ex tb IIIC T135°C/T100°C/T85°C Db
UL/NEC classification Class I, Div. 2, Groups A*, B*, C, D
Class II, Div. 2, Groups F, G
Class I, Zone 1 AEx d IIC* & IIB, Ex d IIB
Approvals SIL1, EN54-23, Russian fire approval, CCCF, CSFM
Certified temperature -55°C to +70°C
Ingress protection IP66 & IP67, NEMA 4X & 6
Material Corrosion free GRP
Entries Up to 3* x M20, M25, ½” NPT or ¾” NPT
Weight 2.6kg - 3.0kg
Voltage 24-48Vdc, 110-254Vac
Light source Xenon
Options Tube energy, flash rate, lens colour, lens guard,
mounting, tag & duty label, relay initiate,
telephone initiate, body colour
210
2
90
1
90
1
20
1
239mm ±5
150mm
3
118mm
2
240mm
±
5
36 1 A/F
Direct mount Direct mount
16 EATON signalling and alarms product overview
XB8
0.5 joule Ex ia xenon beacon
Certification ATEX, IECEx, TR CU, CCOE
Area classification Zone 0, 1, 2, weatherproof
ATEX/IEC classification Ex II 1G, Ex ia IIC/IIB T4 Ga
Approvals ABS
Certified temperature -55°C to +60°C
Ingress protection IP66 & IP67
Material Body: corrosion free GRP. Lens: polycarbonate
Entries Up to 3 x M20 via knockouts
Weight 1.4kg
Voltage 12-24Vdc
Light source Xenon
Options Lens colour, tag & duty label, body colour
XB16
10 joule UL xenon beacon
Certification cULus
Area classification Hazardous locations, ordinary locations
UL/NEC classification Class I, Div. 2, Groups A, B, C, D
Class II, Div. 2, Groups F, G
Approvals UL1971, CSFM
Certified temperature -55°C to +70°C
Ingress protection IP66 & IP67, NEMA 4X & 6
Material Corrosion free GRP
Entries 1 x ¾” NPT
Weight 1.0kg
Voltage 24-48Vdc, 110-254Vac
Light source Xenon
Options Flash rate, lens colour, lens guard, tag & duty
label, relay initiate, body colour
TH12
Ex d rotating beacon
Certification ATEX, IECEx, TR CU, INMETRO
Area classification Zone 1, 2, weatherproof
ATEX/IEC classification Ex II 2G, Ex d IIB T3/T4 Gb
Certified temperature -55°C to +70°C
Ingress protection IP66 & IP67
Material Corrosion free GRP
Entries 2 x M20
Weight 7.6kg
Voltage 12-24Vdc, 110-240Vac
Light source Rotating tungsten halogen
Options Rotation speed, lens colour, lens guard, mounting,
tag & duty label, earth continuity, body colour
Hazardous area beacons
17EATON signalling and alarms product overview
Hazardous area beacons
FL4 & FB4
Ex d(e) Steady beacons
Certification ATEX, IECEx, cULus, TR CU
Area classification Zone 1, 2, 21, 22, weatherproof
ATEX/IEC classification FB4: Ex II 2GD, Ex d IIC T3/T4/T5 Gb
Ex tb IIIC T185°C/T135°C/T100°C Db
FB4: Ex II 2GD, Ex de IIC Ex tD A21 T3/T4/T5
FL4: Ex II 2GD, Ex d IIC T4/T5/T6 Gb
Ex tb IIIC T135°C/T100°C/T85°C Db
FL4: Ex II 2GD, Ex de IIC Ex tD A21 T4/T5/T6
UL/NEC classification Class I, Div. 1, Groups C, D
Class I, Zone 1, Groups IIB & IIA
Certified temperature -55°C to +70°C
Operating temperature FL4: -20°C to +70°C
FB4: -55°C to +70°C
Ingress protection IP66 & IP67, NEMA 4X & 6
Material Stainless steel or alloy
Entries Up to 4* x M20, M25, ½” NPT or ¾” NPT
Weight Alloy: 6.5kg - 8.9kg
Stainless steel: 14.9kg - 17.3kg
Voltage 24-48Vdc, 110-254Vac
Light source Filament, fluorescent
Options Lamp wattage, lens colour, lens guard, tag & duty
labels, relay initiate, body colour
SM87LU1/LU3
Ex d Steady beacons
Certification ATEX, IECEx, cULus, CSA, TR CU, CQST, INMETRO
Area classification Zone 1, 2, 21, 22, weatherproof
ATEX/IEC classification SM87LU1:Ex II 2GD, Ex d IIC T6 Gb,
Ex tb IIIC T85°C Db
SM87LU3:Ex II 2GD, Ex d IIC T3/T4/T5/T6 Gb
Ex tb IIIC T155°C/T130°C/T100°C/
T85°C Db
UL/NEC classification Class I, Div. 1, Groups C, D
Class I, Zone 1, Aex d IIB, Exd IIB
Approvals Russian fire approval
Certified temperature SM87LU1: -55°C to +55°C
SM87LU3: -55°C to +70°C
Operating temperature SM87LU1: -20°C to +55°C
SM87LU3: -55°C to +70°C
Ingress protection IP66 & IP67, NEMA 4X & 6
Material Stainless steel or alloy
Entries SM87LU1: Up to 3 x M20, M25, ½” NPT or ¾”
NPT
SM87LU3: Up to 4 x M20, M25, ½” NPT or ¾”
NPT
Weight Alloy: 2.5kg. Stainless steel: 3.8kg
Voltage 24-48Vdc, 110-254Vac
Light source Filament, fluorescent
Options Lens colour, lens guard, tag/duty label, body colour
*Model dependent
18 EATON signalling and alarms product overview
FB11 & FL11
Ex d Steady beacons
Certification ATEX, IECEx, cULus, TR CU, INMETRO
Area classification Zone 1, 2, 21*, 22*, weatherproof
ATEX/IEC classification Ex II 2GD, Ex d IIB T4/T5/T6 Gb
Ex tb IIIC T110°C/T85°C/T70°C Db
UL/NEC classification Class I, Div. 2, Groups C, D
Class I, Zone 1, AEx d IIB, Ex d IIB
Approvals Russian fire approval
Certified temperature -55°C to +70°C
Operating temperature FB11: -55°C to +70°C
FL11: -20°C to +70°C
Ingress protection IP66 & IP67, NEMA 4X & 6
Material Corrosion free GRP
Entries 2 x M20 or ½” NPT
Weight 2.8kg
Voltage 24-48Vdc, 110-254Vac
Light source Filament, fluorescent
Options Lamp wattage, lens colour, lens guard, mounting,
earth continuity, tag & duty labels, body colour
FL12 & FB12
Ex d Steady beacons
Certification ATEX, IECEx, cULus, TR CU, INMETRO
Area classification Zone 1, 2, weatherproof
ATEX/IEC classification FB11: Ex II 2G, Ex d IIB T3/T4/T5 Gb
FL11: Ex II 2G, Ex d IIB T4/T5/T6 Gb
UL/NEC classification Class I, Div. 2, Groups C, D
Class I, Zone 1, AEx d IIB, Ex d IIB
Approvals Russian fire approval
Certified temperature FB12: -55°C to +55°C
FL12: -20°C to +70°C
Ingress protection IP66 & IP67, NEMA 4X & 6
Material Corrosion free GRP
Entries 2 x M20 or ½” NPT
Weight 7.2kg - 7.6kg
Voltage 24-48Vdc, 110-254Vac
Light source Filament, fluorescent
Options Lamp wattage, lens colour, lens guard, mounting,
earth continuity, tag & duty labels, body colour
Hazardous area beacons
FB15
Ex d Steady beacon
Certification ATEX, IECEx, cULus, TR CU, INMETRO
Area classification Zone 1, 2, 21, 22, weatherproof
ATEX/IEC classification Ex II 2GD, Ex db IIC T3/T4 Gb
Ex tb IIIC T200°C/T135°C Db
UL/NEC classification Class I, Div. 2, Groups A*, B*, C, D
Class I, Zone 1 AEx d IIC* & IIB, Ex d IIB
Approvals Russian fire approval, CSFM
Certified temperature -55°C to +70°C
Ingress protection IP66 & IP67, NEMA 4X & 6
Material Corrosion free GRP
Entries Up to 3* x M20, M25, ½” NPT or ¾” NPT
Weight Pipe: 2.6Kg. Direct: 3.0Kg
Voltage 24-48Vdc, 110-254Vac
Light source Filament
Options Lamp wattage, lens colour, lens guard, mounting,
tag & duty label, lens colour
Direct mount Pipe mount
*Model dependent
210
2
90
1
90
1
20
1
239mm ±5
150mm
3
118mm
2
240mm
±
5
36 1 A/F
19EATON signalling and alarms product overview
Industrial beacons
BLK-LED BLK-Super-LED BLG-LED BLE-LED ActiveLine GH1
ActiveLine GH2 Alpha 1/2/3 & 4 Profiflash XB13 BLG 10
BLE 15 BLK BLS SLD1/SLD2 Profilux
Page 21 Page 21 Page 21 Page 22 Page 22
Page 22 Page 23 Page 23 Page 23 Page 24
Page 24 Page 24 Page 25 Page 25 Page 25
Eaton’s range of weatherproof flashing beacons and status lights, including single colour
or multi coloured options, can be either flashing, steady-state indicators or rotating units,
providing solutions for harsh safe area environmental conditions.
These may be used to warn of potential hazards or indicate the status of plant items,
gas and oil leaks and evacuation alerts in safe areas. The signals can be operated as
stand-alone units or be incorporated into a wider system, such as a fire panel. Many units
can also be customised with a choice of sources or lens colours.
We now offers a comprehensive range of LED beacons, which have the added benefit of
low energy consumption, an increased lifespan and an option of flash patterns.
20 EATON signalling and alarms product overview
Industrial beacons
BLK-Super-LED
Weatherproof LED beacon
Area classification Weatherproof
Operating temperature -55°C to +75°C
Ingress protection IP65
Material Aluminium
Entries Up to 2 x M20
Weight 1.4kg
Voltage 24Vdc, 230Vac
Light source LED
Options Flash function, lens colour
BLG-LED
Weatherproof LED beacon
Area classification Weatherproof
Operating temperature -40°C to +50°C
Ingress protection IP67
Material Body: rubber
Lens: polycarbonate
Entries Cable diameter 6-8mm
Weight 0.45kg
Voltage 12-24Vdc, 115-230Vac
Light source LED
Options Flash function, LED colour
160mm
Ø120mm
Ø150mm
BLK-LED
Weatherproof LED beacon
Area classification Weatherproof
Operating temperature -30°C to +50°C
Ingress protection IP65
Material Aluminium
Entries Up to 2 x M20
Weight 0.7kg
Voltage 12-24Vdc, 230Vac
Light source LED
Options Flash function, lens colour
104
M20 x 1.5
130mm
107mm
104
M20 x 1.5
130mm
107mm
21EATON signalling and alarms product overview
Industrial beacons
BLE-LED
Weatherproof LED beacon
Area classification Weatherproof
Operating temperature -40°C to +65°C
Ingress protection IP66
Material Polycarbonate
Entries 1 x cable gland M20 & 2 x blank plugs M20
Weight 1.3kg
Voltage 24Vdc, 85-265Vac
Light source LED
Options Flash function, lens colour
Ø97mm
314mm
ActiveLine GH1
Multicolour weatherproof LED beacon
Area classification Weatherproof
Operating temperature -25°C to +60°C
Ingress protection IP54
Material Enclosure & footbracket: thermoplastic
Stand: aluminium
Lens: polycarbonate
Entries Male thread bush M16
Weight 0.3kg
Voltage 24Vdc, 230Vac
Light source Multicolour LED
Options With/without sounder, flash functions, LED colour
300mm
Ø70mm
ActiveLine GH2
Multicolour weatherproof LED beacon
Area classification Weatherproof
Operating temperature -25°C to +60°C
Ingress protection IP54
Material Enclosure: thermoplastic
Lens: polycarbonate
Entries 1 x M16
Weight 0.3kg
Voltage 24Vdc, 230Vac
Light source Multicolour LED
Options Flash function, LED colour
29
55
Ø
68,5
75
204
69
40,5
204mm
100mm
22 EATON signalling and alarms product overview
Alpha 1, Alpha 2, Alpha 3 & Alpha 4
LED Obstruction light
Area classification Weatherproof
Approvals ICAO annex 14 (low intensity)
Operating temperature -20°C to +50°C
Ingress protection IP65
Material Body: rubber
Lens: polycarbonate
Entries Cable diameter 6-8-mm (Alpha 2-4 prewired)
Weight 0.5kg - 4.5kg*
Voltage 24Vdc, 115-230Vac
Light source LED
Options Mounting
221mm
135mm
142mm
Industrial beacons
Profiflash
5 joule weatherproof beacon
Area classification Weatherproof
Operating temperature -20°C to +40°C
Ingress protection IP54
Material Housing: ABS
Lens: polycarbonate
Entries Male thread bush M16
Weight 0.36kg
Voltage 24Vdc, 230Vac
Light source Xenon
Options Lens colour, housing colour, mounting options
227mm
109mm
XB13
10 joule weatherproof xenon beacon
Area classification Weatherproof
Operating temperature -40°C to +70°C
Ingress protection IP66 & IP67
Material Body: corrosion free GRP
Lens: polycarbonate
Entries Up to 3 x M20 via knockouts
Weight 1.1kg
Voltage 12-48Vdc, 115-230Vac
Light source Xenon
Options Body & lens colour, tag & duty labels, lens guard,
telephone & relay initiate, single & dual flash
mode
366,5mm
135mm
142mm
Alpha 2 / Alpha 3 and Alpha 4 shown Alpha 2 and Alpha 3 shown
*Model dependent
23EATON signalling and alarms product overview
Industrial beacons
BLE 15
15 joule weatherproof beacon
Area classification Weatherproof
Operating temperature -40°C to +50°C
Ingress protection IP66
Material Polycarbonate
Entries 1 x cable gland M20 & 2 x blank plugs M20
Weight 1.0kg
Voltage 24vdc, 230Vac
Light source Xenon
Options Lens colour
BLG 10
10 joule weatherproof beacon
Area classification Weatherproof
Operating temperature -20°C to +50°C
Ingress protection IP67
Material Body: rubber
Lens: polycarbonate
Entries Cable diameter 6-8mm
Weight 0.45kg
Voltage 10-100Vdc, 20-230Vac
Light source Xenon
Options Lens colour
BLK
5 & 15 joule weatherproof beacons
Area classification Weatherproof
Operating temperature -50°C to +50°C*
Ingress protection IP65
Material Aluminium
Entries Up to 2 x M20
Weight 0.7kg
Voltage 12-48Vdc, 24-230Vac
Light source Xenon
Options Tube energy, temperature range, lens colour
160mm
Ø120mm
Ø150mm
Ø97mm
314mm
104
M20 x 1.5
130mm
107mm
*Model dependent
24 EATON signalling and alarms product overview
SLD1/SLD2
Weatherproof rotating halogen beacons
Area classification Weatherproof
Approvals German Federal Office for Motor Traffic
Operating temperature -20°C to +50°C
Ingress protection IP54
Material Plastic socket with die cast metal bottom (for SLD
1 and 3) and full-surface PVC sealing
Entries Cable diameter 8-12mm
Weight 1.0kg - 2.3kg*
Voltage SLD1: 12-24Vdc, 110-230Vac
SLD2: 12-24Vdc
Light source Halogen bulb 55/70W
Options Lens colour
215mm
120mm
160mm
130mm
Industrial beacons
BLS
5 & 15 joule weatherproof beacons
Area classification Weatherproof
Operating temperature -30°C to +50°C
Ingress protection IP54
Material ABS
Entries 1x self-sealing grommet M16
Weight 0.7kg
Voltage 12-24Vdc, 24-230Vac
Light source Xenon
Options Tube energy, lens colour
86mm
204mm
Profilux
Weatherproof steady beacon
Area classification Weatherproof
Operating temperature -20°C to +40°C
Ingress protection IP54
Material ABS
Entries Male thread bush M16
Weight 0.36kg
Voltage 24vdc, 230Vac
Light source Filament 15W
Options Housing colour, lens colour, mounting
250mm
135mm
227mm
109mm
*Model dependent
25EATON signalling and alarms product overview
The MEDC and FHF range of sounders are suitable for a wide variety
of applications and feature a selection of tone settings and traditional
bells.
Sounders are used to warn of potentially dangerous situations or to
relay instructions. In addition the alarms may operate as stand-alone
units or be incorporated into a hazard warning system. A wide
variety of sound output levels and other options are also available.
The sounders output in dB is measured to European standards at 1
metre.
Hazardous area sounders
DB1P DB3B dEV 20 DB5
DB7 DB6 dGW21/dRGW21 dGH 21 / dRGH 21
Page 28 Page 28 Page 29 Page 29
Page 29 Page 30 Page 30 Page 30
mHG 11 mHP11 mHP12
Page 31 Page 31 Page 31
26 EATON signalling and alarms product overview
The MEDC DB3B, the latest addition to the sounder range boasts
improved functionality and performance; including a higher output than
the DB3, with SPL reaching 122dB @ 1m (+/-3dB). This significantly
improves sound coverage in high noise environments, and ensures that
our product will be effective in almost any application.
The DB3B is ATEX, IECEx, INMETRO, cULus, TR CU, CQST, CCOE, CCCF
and SIL 1 certified, and can be purchased as part of a beacon/sounder
combination unit (please contact Eaton for details). In addition, it is
available as either a flameproof enclosure (Ex d), or increased safety
unit (Ex de), as well as protection against Gas or Gas & Dust
atmospheres, allowing for greater flexibility to suit most specifications.
Hazardous area sounder
Maximum output of 122dB @1m
Certified –55°C to +70°C
ATEX, IECEx, cULus, TR CU, CQST, CCOE, CCCF, SIL 1 & INMETRO certified
Improved current consumption (329mA at nominal 24Vdc low inrush)
Increased room in terminal chamber
Drivers tested for over 1500 hours at full power
Ex d/ Ex de units available
Gas/ Gas & Dust units available
Increased room in terminal chamber
Improved control options
28 user selectable tones
27EATON signalling and alarms product overview
Hazardous area sounders
DB3B
Ex d(e) Sounder
Certification ATEX, IECEx, cULus, TR CU, CQST, INMETRO, CCOE
Area classification Zone 1, 2, 21, 22*, weatherproof
ATEX/IEC classification Ex II 2G, Ex d IIC T4/T5/T6 Gb
Ex II 2GD, Ex d IIC T4/T5/T6 Gb
Ex tb IIIC T135°C/T100°C/T85°C Db
Ex II 2G, Ex de IIC T4/T5/T6 Gb
Ex II 2GD, Ex de IIC T4/T5/T6 Gb
Ex tb IIIC T135°C/T100°C/T85°C Db
UL/NEC classification Class I, Div. 2, Groups A, B, C, D
Class II, Div. 2, Groups F, G
Approvals SIL1, Russian fire approval, CCCF, CSFM
Certified temperature -55°C to +70°C
Ingress protection IP66 & IP67, NEMA 4X & 6
Material Body: corrosion free GRP
Flare: thermoplastic
Entries Up to 2 x M20 or ½” NPT
Weight Ex d: 4.6kg (based on long flare unit)
Ex de: 5.4kg (based on long flare unit)
Voltage 12-48Vdc, 110-254Vac
Sound output Max: 122dB, 1m (±3dB)*
Tones 28
Stages 3 (5 voltage free)
Options Tag & duty labels, swivel bracket, EOL resistor,
Earth continuity, tone activation method, voltage
free activation, flare type, custom tones, flare
colour
200mm ±2
280mm ±3
143mm ±2
*Model dependent
DB1P
Ex d Sounder
Certification ATEX, IECEx, cULus, TR CU, CCOE
Area classification Zone 1, 2, weatherproof
ATEX/IEC classification Ex II 2G, Ex d IIB T5/T6
NEC classification Class I, Div. 1, Groups C, D
Approvals SIL1, Russian fire approval
Certified temperature -25°C to +70°C
Ingress protection IP66, NEMA 4X
Material Stainless steel or alloy
Entries Up to 3 x M20, M25, ½” NPT or ¾” NPT
Weight 3.5kg - 12.7kg*
Voltage 12-48Vdc, 110-240Vac
Sound output Max: 110dB, 1m (±3dB)*
Tones 27
Stages 2*
Options Output level, entries, tag & duty labels, telephone
or relay initiate, remote tone select, EOL resistor,
colour
28 EATON signalling and alarms product overview
DB5
Ex ia Sounder
Certification ATEX, ATEX mining, IECEx, IECEx mining, FM, CSA,
CCOE
Area classification Zone 1, 2
ATEX/IEC classification Ex II 1G, Ex ia IIC T4 Ga
Ex I M1, Ex ia I Ma
UL/NEC classification Class I, Div. 2, Groups A, B, C, D
Certified temperature -20°C to +55°C
Ingress protection IP66
Material ABS
Entries Up to 2 x M20 via knockouts
Weight 0.3kg
Voltage 12-24Vdc
Sound output Max: 100dB, 1m (±3dB)
Tones 26
Options Tag label, colour
dEV 20
Ex de sounder
Certification ATEX, IECEx, INMETRO
Area classification Zone 1, 2, 21, 22, weatherproof
ATEX/IEC classification Ex II 2G, Ex de IIB + H2 T6 Gb
Ex II 2D, Ex tb IIIC T85°C Db
Certified temperature -50°C to +60°C
Ingress protection IP66
Material Aluminium
Entries 1 x M20
Weight 2.8kg
Voltage 24Vdc, 85-265Vac
Sound output Max: 115dB, 1m (±3dB)
Tones 32
Stages 2
Ø144mm
345mm
Hazardous area sounders
DB7
Ex ia Sounder
Certification ATEX, TR CU, CCOE
Area classification Zone 0, 1, 2, weatherproof
ATEX/IEC classification Ex II 1G, Eex ia IIB/IIC T4*
Approvals Russian fire approval
Certified temperature -55°C to +70°C
Ingress protection IP66 & IP67
Material Corrosion free GRP
Entries Up to 3 x M20 via knockouts
Weight 1.0kg
Voltage 12-24Vdc*
Sound output Max: 106dB, 1m (±3dB)*
Tones 27
Stages 2
Options Tag & duty labels, colour
*Model dependent
29EATON signalling and alarms product overview
Hazardous area sounders
dGH 21 / dRGH 21
Ex de Hooter
Certification ATEX, UL, TR CU
Area classification Zone 1, 2
ATEX/IEC classification Ex II 2 G, Ex de IIC T5/T6*
UL/NEC classification Class I, Div. 2, Groups A, B, C, D
Certified temperature -20°C to +75°C*
Ingress protection IP66, NEMA 4X
Material Corrosion free GRP
Entries 2 x M20
Weight 5.5kg
Voltage 12-24Vdc, 110-240Vac
Sound output Max: 105dB, 1m (±3dB)
Options Call relay, body colour
217mm
273mm
DB6
Ex d Bell
Certification ATEX, IECEx
Area classification Zone 1, 2
ATEX/IEC classification Ex II 2G, Ex d IIB T5 Gb
Certified temperature -20°C to +55°C
Ingress protection IP65
Material Cast iron
Entries 2 x M20 & 1 x blank plug M20
Weight 11.0kg
Voltage 24Vdc, 240Vac
Sound output Max: 106dB, 1m (±3dB)*
Options Tag label, colour
426mm
195mm
dGW21/dRGW21
Ex de Bell
Certification ATEX, UL, TR CU
Area classification Zone 1, 2
ATEX/IEC classification Ex II 2 G, EEx de IIC T6
UL/NEC classification Class I, Div. 2, Groups A, B, C, D
Certified temperature -20°C to +40°C
Ingress protection IP66, NEMA 4X
Material Corrosion free GRP
Entries 1 x M20 & 1 x blank plug
Weight 5.5kg
Voltage 12-24Vdc, 110 - 240Vac
Sound output Max: 105dB, 1m (±3dB)
Options Telephone relay, body colour
200mm
210mm
270mm
110mm
*Model dependent
30 EATON signalling and alarms product overview
mHP11
Ex em Hooter
Certification ATEX, IECEx, INMETRO
Area classification Zone 1, 2
ATEX/IEC classification II 2 G, Ex emb II T4/T5*
Operating temperature -20°C to +70°C*
Ingress protection IP54
Material Polycarbonate
Entries 1 x M20
Weight 1.0kg
Voltage 24Vdc, 115Vac, 230Vac
Sound output Max: 108dB, 1m (±3dB)
141
134mm
346mm
mHP12
Ex em Hooter
Certification ATEX, IECEx
Area classification Zone 1, 2
ATEX/IEC classification II 2 G, Ex emb II T4/T5*
Operating temperature -20°C to +70°C*
Ingress protection IP54
Material Polycarbonate
Entries 1 x M20
Weight 1.0kg
Voltage 24Vdc, 230Vac
Sound output Max: 108dB, 1m (±3dB)
133mm
152mm
Hazardous area sounders
mHG 11
Ex em Hooter
Certification ATEX, IECEx, INMETRO
Area classification Zone 1, 2, 21, 22
ATEX/IEC classification II 2 G, Ex emb II T4/T5*
II 2 D, Ex tD A21 IP66 T90°C
Operating temperature -55°C to +70°C (T4)
Ingress protection IP66
Material Aluminium
Entries 1 x M20
Weight 2.0kg
Voltage 24Vdc, 115Vac, 230Vac
Sound output Max: 108dB, 1m (±3dB)
141
146
331
132mm
331mm
*Model dependent
31EATON signalling and alarms product overview
Industrial sounders
Eaton offer a range of industrial sounders specifically designed for harsh
environmental conditions. Designed to function in extreme
temperatures, and with ingress protection ratings of up to IP66, these
sounders have been engineered to consistently work in the harshest of
environmental conditions.
DB12 DB15 AW 1 - 6 UWE PH1
HP & HPO HPW 11 & HPW 12 HGK HGW11 EKS/EKSP
AX05 AX08 EV 21 voice
Page 33 Page 33 Page 33 Page 34 Page 34
Page 34 Page 35 Page 35 Page 35 Page 36
Page 38 Page 38 Page 38
KS F0, FI, FII, FIII EV 21/EV 24 EV 11 AX03
Page 36 Page 36 Page 37 Page 37 Page 37
32 EATON signalling and alarms product overview
Industrial sounders
DB12
Weatherproof sounder
Area classification Weatherproof
Operating temperature -55°C to +70°C
Ingress protection IP66 & IP67
Material Corrosion free GRP
Entries Up to 3 x M20 via knockouts
Weight 1.2kg
Voltage 12-24Vdc, 115-230Vac
Sound output Max: 110dB, 1m (±3dB)
Tones 27
Stages 2*
Options Tag & duty labels, body colour
DB15
Weatherproof sounder
Area classification Weatherproof
Operating temperature -55°C to +70°C
Ingress protection IP66 & IP67
Material Corrosion free GRP
Entries 2 x M20 & 1 x blank plug M20
Weight 2.6kg
Voltage 12-48Vdc, 110-254Vac
Sound output Max: 117dB, 1m (±3dB)
Tones 27
Stages Up to 2
Options Tag & duty labels, Earth continuity, EOL resistors,
blank plug, colour
AW 1-6 signalling bell
Weatherproof bell
Area classification Weatherproof
Operating temperature -20°C to +60°C
Ingress protection IP55
Material Body: aluminium. Dome: steel
Entries 1 x M20
Weight 1.45kg - 2.95kg*
Voltage 6-220Vdc, 12-240Vac*
Sound output Max: 110dB, 1m (±3dB)*
Options Dome size, strike rate
250mm
130mm
110mm
120mm
130mm
196mm
*Model dependent
33EATON signalling and alarms product overview
Industrial sounders
PH1
Industrial pneumatic horn
Area classification Industrial
Operating temperature -25°C to +40°C
Material Impact-resistant plastic
Weight 0.34kg
Voltage 24Vdc, 230Vac*
Sound output Max: 135dB, 1m (±3dB)
Tones 400Hz operated with compressed air
UWE signalling bell
Bell
Area classification Industrial
Operating temperature -10°C to +55°C
Ingress protection IP40
Material Body: plastic. Dome: steel
Entries 1 x M20
Weight 1.2kg
Voltage 18-30Vdc, 200-250Vac*
Sound output Max: 96dB, 1m (±3dB)
Ø155mm
85mm
HP & HPO
Weatherproof hooter
Area classification Weatherproof
Operating temperature -20°C to +60°C
Ingress protection IP43
Material Impact resistant thermoplastic (ABS)
Entries Cable diameter 5-8mm
Weight 0.185kg
Voltage 6-220Vdc, 6-230Vac*
Sound output Max: 92dB, 1m (±3dB)
Options Trumpet
34 EATON signalling and alarms product overview
100mm
375mm
Ø125mm
60mm
80mm
64mm
80mm
152mm
80mm
67mm 72mm
58mm
*Model dependent
HPW 11 & HPW 12
Weatherproof hooter
Area classification Weatherproof
Operating temperature -20°C to +60°C
Ingress protection IP55
Material Impact resistant thermoplastic (ABS)
Entries 1 x M20 self sealing grommet
Weight 1.1kg
Voltage 6-230Vdc, 6-240Vac*
Sound output Max: 108dB, 1m (±3dB)
Options Trumpet
HGK
Weatherproof hooter
Area classification Weatherproof
Operating temperature -20°C to +60°C
Ingress protection IP65
Material Aluminium with ABS cover
Entries 1 x M20
Weight 1.75kg
Voltage 24Vdc, 230Vac*
Sound output Max: 108dB, 1m (±3dB)
156mm
221mm
134mm
118mm
Industrial sounders
*Model dependent
35EATON signalling and alarms product overview
134mm
128mm
346mm
141mm
HGW11
Weatherproof hooter
Area classification Weatherproof
Operating temperature -20°C to +60°C
Ingress protection IP56
Material Aluminium
Entries 1 x M20
Weight 2.7kg
Voltage 6-220Vdc, 6-240Vac*
Sound output Max: 108dB, 1m (±3dB)
HGW11 hooter
140
M20 x 1,5
128
133mm
345mm
Industrial sounders
KS
Weatherproof motor siren
Area classification Weatherproof
Operating temperature -20°C to +50°C
Ingress protection IP44
Material Thermoplastic
Entries 1 x M16
Weight 0.45kg
Voltage 24Vdc, 230Vac*
Sound output Max: 100dB, 1m (±3dB)
F0 FI FII FIII
Weatherproof motor siren
Area classification Weatherproof
Operating temperature 0°C (-40°C with protection cover) to +65°C
Ingress protection IP22 (IP44 with protection cover)
Material Aluminium
Entries F0,FI & FII: M16.
FIIa & FIIIb: M20
Weight 1.6kg - 22.0kg*
Voltage 24-230Vdc, 24-400Vac*
Sound output Max: 123dB, 1m (±3dB)*
Options Protection cover
EKS/EKSP
Weatherproof sounder
Area classification Weatherproof
Operating temperature -20°C to +70°C
Ingress protection IP30
Material Thermoplastic
Weight 0.05kg
Voltage 24-48Vdc, 24-230Vac*
Sound output Max: 90dB, 1m (±3dB)
Options Tone
EKS / EKSP sounder
43mm
100mm
86mm
147mm
KS Siren LD
Ø
312
~ 235
Ø 5
Ø
90
120°
120°
Ø
106mm
Ø
110mm
169mm
F0 Siren
F0 shown
*Model dependent
36 EATON signalling and alarms product overview
Industrial sounders
EV 21/EV 24
Weatherproof sounder
Area classification Weatherproof
Operating temperature EV 21: -25°C to +60°C
EV 24: -50°C to +60°C
Ingress protection IP54
Material Aluminium
Entries 1 x M20
Weight 1.7kg
Voltage 12-24Vdc, 12-230Vac*
Sound output Max: 105dB, 1m (±3dB)
Tones 21
Stages 3
*Model dependent
116
70
100
M20x1.5
130mm
107mm
EV 11
Weatherproof sounder
Area classification Weatherproof
Operating temperature -25°C to +50°C
Ingress protection IP55
Material Aluminium
Entries 2 x M20 & 2 x blank plugs M20
Weight 4.0kg
Voltage 24Vdc, 24-230Vac*
Sound output Max: 118dB, 1m (±3dB)
Tones 7 tone, chime and voice
Options Desktop microphone, pre-amplifier
210
168
141
207
183
EV11
340mm
84mm
AX03
Weatherproof sounder
Area classification Weatherproof
Operating temperature -25°C to +70°C
Ingress protection IP66
Material Plastic
Entries Up to 2 x M20 via knockouts
Weight AC: 0.4kg. DC: 0.3kg
Voltage 9-60Vdc, 115-230Vac*
Sound output Max: 105dB, 1m (±3dB)
Tones 32
Stages 2
119mm
136mm
136mm
37EATON signalling and alarms product overview
Industrial sounders
AX08
Weatherproof sounder
Area classification Weatherproof
Operating temperature -25°C to +70°C
Ingress protection IP66
Material Plastic
Entries Up to 2 x M20 via knockouts
Weight AC 2.5kg, DC 1.6kg
Voltage 24Vdc, 115-230Vac*
Sound output Max: 120dB, 1m (±3dB)
Tones 42
Stages 3
AX05
Weatherproof sounder
Area classification Weatherproof
Operating temperature -25°C to +70°C
Ingress protection IP66
Material Plastic
Entries Up to 2 x M20 via knockouts
Weight AC 0.7kg, DC 0.5kg
Voltage 9-60Vdc, 115-230Vac*
Sound output Max: 112dB, 1m (±3dB)
Tones 32
Stages 2
165mm
132mm
136mm
168mm
168mm
55mm
*Model dependent
EV 21 voice
Weatherproof sounder
Area classification Weatherproof
Operating temperature -25°C to +60°C
Ingress protection IP54
Material Aluminium
Entries 1 x M20
Weight 1.4kg
Voltage 24Vdc, 85-265Vac
Sound output Max: 105dB, 1m (±3dB)
Capacity 4GB storage
Options 2nd entry
116
70
100
M20x1.5
130mm
107mm
38 EATON signalling and alarms product overview
Introducing the EV 21 Voice sounder
The EV 21 V Voice Sounder is a compact electronic signalling device designed for both industrial and commercial
applications for either internal or external use.
Applications include production line and process control announcements or warnings, timed voice announcements and
many others.
The EV 21 V can provide up to eight different speech announcements that can be proceeded by an alert tone to attract the
attention of the message recipient.
An internal 4 GB micro SD memory card provides the non-volatile memory for the storage of both alert tones and messages
accordingly. Message and alert tones are stored as WAV files and can be assigned different volume levels.
The programming and configuration of the EV21 V is achieved using an easy to use PC based application for ease of
programming and configuration even when installed using a via laptop via a USB interface.
Capacity: Up to eight message announcements proceeded by alert
tones
Memory: 4GB Micro SD Memory Card
Maximum Sound Pressure Level: 105dBA
Power supply: 85-265 Vac or 24 Vdc
Operating temperature: -25°C to +60°C
Ingress protection: IP54
39EATON signalling and alarms product overview
Hazardous area loudspeakers
Eatons range of explosion protected, heavy duty, industrial and
commercial speakers are designed to meet the requirements for public
address, voice alarm and evacuation procedures. This range of
loudspeakers, specifically designed for potentially explosive gas and dust
atmospheres, is suitable for use in the harsh environmental conditions
found offshore and onshore in the oil, gas and petrochemical industries.
The units can be operated as part of 100 or 70 volt line systems, and
include a wide range of sound output levels, which are all measured in
dB at 1 watt / 1 metre.
Eaton ensures the production of rugged, hard wearing products by using
corrosion free materials such as GRP (glass reinforced polyester) and
stainless steel.
DB10 DB16
Page 42 Page 42 Page 43
Page 43 Page 43
DB4B DB20C DB20
40 EATON signalling and alarms product overview
The DB4B, a new high power,
explosion proof loudspeaker
launched by Eaton, offers a specific
SPL figure of up to 124dB (for
sensitivity of 25W @ 1m). The 8W
and 15W units generate sufficient
SPL (120dB and 122dB @1M
respectively) to satisfy most
specifications, allowing end users to
install units with lower power
consumption, therefore reducing the
amount of application and support
equipment required.
With a range of certifications, including ATEX,
IECEx, cULus, TR CU, CQST, INMETRO, CCOE,
SIL 2 and DNV the DB4B is manufactured
from a GRP Ex enclosure and rugged
thermoplastic flare. The units are also
certified for from -55°C up to +70°C*,
ensuring that our products are suitable for
safe use in the harshest working
environments.
The DB4B has an extended frequency
response, ensuring that critical voice
messages and general alarm tones are highly
intelligible. This allows the human voice to be
heard and clearly understood, as
demonstrated on the below frequency
response chart. In addition, the new unit
provides a clearer sound for sibilant
consonants, allowing for much crisper and
intelligible speech.
MEDC DB4B – 124dB loudspeaker
ATEX/IECEx/cULus/TR CU/CQST/
INMETRO/CCOE/SIL 2 and DNV
certified
Certified –55°C to +70°C*
Gas/Gas & Dust units available
Ex d/Ex de units available
Extended frequency response
*Model dependent
41EATON signalling and alarms product overview
DB20C
Ex de Loudspeaker
Certification ATEX,IECEx,TR CU
Area classification Zone 1, 2, 21, 22, weatherproof
ATEX/IEC classification Ex II 2GD
Ex de IIC T4/T5, Ex tD A21 T100°C/T115°C/T130°C
Approvals DNV
Operating temperature -50°C to +70°C
Ingress protection IP66 & IP67
Material Body: corrosion free GRP
Flare: U.V. stable ABS
Entries 2 x M20 & 1 x blank plug M20
Weight 1.5kg
Output Sensitivity (1W, 1m): 100dB (±3dB)
Max at full power (4W, 1m): 106dB (±3dB)
Transformer 100V
Wattage & transformer
tappings
4W: 4.0, 2.0, 1.0, 0.75, 0.38, 0.2*
Low impedance 8Ω*
Options Tag & duty labels, Earth continuity, loop in/out
terminals
DB4B
Ex d(e) Loudspeaker
Certification ATEX, IECEx, cULus, TR CU, CQST, INMETRO, CCOE
Area classification Zone 1, 2, 21, 22*, weatherproof
ATEX/IEC classification Ex II 2G, Ex d IIC T4/T5/T6 Gb
Ex II 2GD, Ex d IIC T4/T5/T6 Gb
Ex tb IIIC T135°C/T100°C/T85°C Db
Ex II 2G, Ex de IIC T4/T5/T6 Gb
Ex II 2GD, Ex de IIC T4/T5/T6 Gb
Ex tb IIIC T135°C/T100°C/T85°C Db
UL/NEC classification Class I, Div. 2, Groups A, B, C, D
Class II, Div. 2, Groups F, G
Approvals SIL2, Russian fire approval, DNV, CSFM
Operating temperature -55°C to +70°C*
Ingress protection IP66 & IP67, NEMA 4X & 6
Material Body: corrosion free GRP. Flare: thermoplastic
Entries Up to 2 x M20 or ½” NPT
Weight Ex d: 5.0kg (based on long flare unit)
Ex de: 5.8kg (based on long flare unit)
Sound output Sensitivity (1W, 1m): 110dB* (±3dB)
Max at full power (25W, 1m): 124dB* (±3dB)
Transformer 100V, 70V, 25V
Wattage & transformer
tappings
25W: 25.0, 12.5, 6.0, 4.0, 2.0, 1.0*
15W: 15.0, 7.5, 5.0, 4.0, 2.0, 0.8*
8W: 8.0, 4.0, 2.0, 1.5, 0.7, 0.4*
Low impedance 8Ω*
Options Tag & duty labels, swivel bracket, DC blocking
capacitor, flare length, flare colour
Ø200mm
280mm
208mm
FOR SHORT FLARE
Ø143mm
Ø200mm
CUTOUT
Ø175mm
134mm
Hazardous area loudspeakers
*Model dependent
42 EATON signalling and alarms product overview
DB20
Ex de Loudspeaker
Certification ATEX, IECEx, TR CU, CCOE
Area classification Zone 1, 2, 21, 22*, weatherproof
ATEX/IEC classification Ex II 2G, Ex de IIB T3/T4, Ex II 2GD
Ex de IIC T4/T5, Ex tD A21 T130°C/T115°C/T100°C
Approvals Russian fire approval
Operating temperature -50°C to +70°C
Ingress protection IP66 & IP67
Material Body: corrosion free GRP. Flare: U.V. stable ABS
Entries 2 x M20 & 1 x blank plug M20
Weight 1.5kg
Sound output
Sensitivity (1W, 1m): 100dB* (±3dB)
Max at full power (8W, 1m): 112dB* (±3dB)
Transformer 100V
Wattage & transformer
tappings
8W: 8.0, 4.0, 2.0, 1.5, 0.7, 0.4*
4W: 4.0, 2.0, 1.0, 0.75, 0.38, 0.2*
Low impedance 8Ω*
Options Tag & duty labels, Earth continuity, loop in/out
terminals, colour
ALL DIMENSIONS ARE IN mm
137mm
Ø124mm
103 ±3
DB10
Ex de Loudspeaker
Certification ATEX, IECEx, TR CU, CQST, INMETRO, CCOE
Area classification Zone 1, 2, 21, 22*, weatherproof
ATEX/IEC classification Ex II 2G, Ex de IIB + H2 T4/T5/T6 Gb
Ex II 2G, Ex de IIC T4/T5/T6 Gb
Approvals Russian fire approval, DNV
Operating temperature -50°C to +65°C*
Ingress protection IP66 & IP67
Material Corrosion free GRP
Entries Up to 2 x M20
Weight Short flare: 3.1kg. Long flare: 3.5kg
Sound output Sensitivity (1W, 1m): 105dB* (±3dB)
Max at full power (15W, 1m): 115dB* (±3dB)
Transformer 100V
Wattage & transformer
tappings
8W: 8.0, 4.0, 2.0, 1.0, 0.5, 0.25*
15W: 15.0, 7.5, 3.75, 2.5, 1.25, 0.75*
Low impendance 8Ω*
Options Tag & duty labels, Earth continuity, colour
Ø130mm
157mm
Ø163mm
245mm
Ø126mm
20/15W version
8W version
DB16
Ex de Loudspeaker
Certification ATEX, IECEx, cULus, TR CU, CCOE
Area classification Zone 1, 2, 21, 22*, weatherproof
ATEX/IEC classification Ex II 2G, Ex de IIB T3 Gb
Ex de IIC T3 Gb, Ex tb IIIC T110°C Db
UL/NEC classification Class I, Div. 2, Groups A, B, C, D*
Approvals Russian fire approval, DNV
Certified temperature -50°C to +65°C*
Ingress protection IP66 & IP67
Material Corrosion free GRP
Entries Up to 2 x M20, M25, ½” NPT or ¾” NPT*
Weight 5.5kg
Output Sensitivity (1W, 1m): 110dB* (±3dB)
Max at full power (30W, 1m): 122dB* (±3dB)
Transformer 100V
Wattage & transformer
tappings
25W: 25.0 ,12.5, 6.0, 4.0, 2.0, 1.0*
30W: 30.0, 25.0, 12.0, 6.0, 4.0, 2.0*
Low impedance 8Ω*
Options Tag & duty labels, Earth continuity, Earth stud,
colour
354.5mm
Ø262mm
Hazardous area loudspeakers
*Model dependent
43EATON signalling and alarms product overview
Eatons range of safe area loudspeakers are manufactured from
materials including steel, aluminium and plastic. They also include a
variety of mounting options, suitable for multiple applications.
Industrial loudspeakers
IMCOS 5242 IMCOS 5253 IMCOS 6801
IMCOS 6811 IMCOS 6899 DB14
Page 45 Page 45 Page 45
Page 46 Page 46 Page 46
44 EATON signalling and alarms product overview
IMCOS 5253
Weatherproof loudspeaker
Area classification Weatherproof
Approvals ABS, BV, DNV, GL, LR, RINA, Chinese classification
societies
Operating temperature -25°C to +90°C
Ingress protection IP56
Material Polycarbonate
Entries 2 x PG13
Weight 0.8kg*
Sound output Sensitivity (1W, 1m): 88dB (±3dB)
Transformer 100V
Wattage & transformer
tappings
10W: 10.0, 5.0, 3.5, 2.5, 1.5, 0.8
Low impedance 8Ω
206mm
104mm
Industrial loudspeakers
IMCOS 5242
Industrial loudspeaker
Area classification Industrial
Approvals ABS, BV, DNV, GL, LR, RINA, Chinese classification
societies
Operating temperature -25°C to +90°C
Ingress protection IP22
Material Aluminium
Entries Prewired cable
Weight 1.5kg
Sound output Sensitivity (1W, 1m): 97dB (±3dB)
Transformer 100V
Wattage & transformer
tappings
6W: 6.0, 3.0, 2.0, 1.5, 0.8, 0.5
157mm
175mm
IMCOS 6801
Industrial loudspeaker
Area classification Industrial
Approvals ABS, BV, DNV, GL, LR, RINA, Chinese classification
societies
Operating temperature -25°C to +70°C
Ingress protection IP22
Material Alumnium/steel*
Entries 2 x M20
Weight 1.0kg
Sound output Sensitivity (1W, 1m): 92dB (±3dB)
Transformer 100V
Wattage & transformer
tappings
6W: 6.0, 3.0, 2.0, 1.5, 0.8, 0.5
Low impedance 8Ω
Ø174 mm
*Model dependent
45EATON signalling and alarms product overview
IMCOS 6811
Weatherproof loudspeaker
Area classification Weatherproof
Approvals ABS, BV, DNV, GL, LR, RINA, Chinese classification
societies
Operating temperature -50°C to +90°C
Ingress protection IP66
Material Plastic
Entries 2 x PG16
Weight 1.3kg
Sound output Max at full power (30W, 1m): 119dB (±3dB)
Transformer 100V
Wattage & transformer
tappings
30W: 30.0, 15.0, 10.0, 5.0, 2.5, 1.5
Low impedance 8Ω
197mm
116mm
IMCOS 6899
Weatherproof loudspeaker
Area classification Weatherproof
Approvals ABS, BV, DNV, GL, LR, RINA, Chinese classification
societies
Operating temperature -25°C to +90°C
Ingress protection IP55
Material ABS
Entries Prewired cable
Weight 0.35kg
Sound output Max at full power (1.5W, 1m): 92dB (±3dB)
Transformer 100V
Wattage & transformer
tappings
1.5W
102mm
69mm
34mm
57mm
Industrial loudspeakers
DB14
Weatherproof loudspeaker
Area classification Weatherproof
Operating temperature -55°C to +70°C*
Ingress protection IP66 & IP67
Material Corrosion free GRP
Entries 2 x M20
Weight 2.6kg
Output Sensitivity (1W, 1m): 107dB (±3dB)
Max at full power (15W, 1m): 117dB (±3dB)
Transformer 100V
Wattage & transformer
tappings
15W: 15.0, 7.5, 5.0, 4.0, 2.0, 0.8*
Low impedance 8Ω*
Options Tag & duty labels, colour
102mm
69mm
34mm
57mm
*Model dependent
46 EATON signalling and alarms product overview
Hazardous Area
Communications
MEDC Oxalis IMCOSTM HERNISTM SonixTM Yuhua FHF
Hazardous Area Communications is a comprehensive product
offering for potentially explosive atmospheres, bringing together a
range of specialist systems and solutions for the fire & gas, telecoms
and CCTV markets.
Our solution names of MEDC, Oxalis, IMCOSTM, HERNISTM, SonixTM,
Yuhua and FHF offer a specialised team of highly qualified staff to
ensure all aspects of engineering, design and configuration with
your project are fulfilled - from initial stages of concept through to
commissioning.
With experience dating back over 100 years, we work together with
one idea in mind; to make working environments a safer, more
reliable place to operate.
47EATON signalling and alarms product overview
Eatons range of audible and visual combination units are designed for the purpose of alerting
audio and visual awareness to an emergency situation. The combination units are built for use
in harsh environmental conditions found offshore and onshore in the oil, gas and petrochemical
industries. As well as the products found in this section, combination units can be built to order
from various sounders and beacons found in this catalogue. Please contact Eaton for details.
Eaton also offer a range of Status Lights designed for potentially explosive atmospheres and
harsh environmental conditions. Status lights are commonly found in oil, gas, petrochemical and
other hazardous areas where multi-coloured lamp combinations are used to identify the safety
status of specific zones. Customers can choose from a range of materials, including stainless steel
and GRP and a selection of light sources including LED.
CU1 DB3B/XB15 DB3B/XB11 DB3B/SM87HXB DB1/SM87HXB
SM87SL XB11SL SL5 SL15 XB12SL
Page 49 Page 49 Page 50 Page 50 Page 51
Page 51 Page 52 Page 52 Page 53 Page 53
Hazardous area status lights and combination units
48 EATON signalling and alarms product overview
DB3B/XB15
Ex d sounder / 5, 10 & 15 joule beacon combination units
Certification ATEX, IECEx, cULus, TR CU, CQST, INMETRO, CCOE
Area classification Zone 1, 2, 21, 22, weatherproof
ATEX/IEC classification Ex II 2GD, Ex d IIC T4/T5/T6 Gb
Ex tb IIIC T135°C/T100°C/T85°C Db*
UL/NEC classification Class I, Div. 2, Groups A, B, C, D
Class II, Div. 2, Groups F, G
Approvals Russian fire approval
Certified temperature -55°C to +70°C
Ingress protection IP66 & IP67, NEMA 4X & 6
Materials Body: corrosion free GRP. Flare: thermoplastic
Entries Up to 2 x M20, M25, ½” NPT or ¾” NPT customer
entries. Note: Customer entries are in the beacon
Voltage 24-48Vdc, 110-254Vac
Sound output Max: 122dB*, 1m (±3dB)
Tones 28
Stages 3
Light source Xenon
Options Tube energy, body, lens & flare colour, lens guard,
flash rate, earth continuity, relay & tel. initiate,
flare type, labels
220mm
490mm
Hazardous area status lights and combination units
CU1
Ex de sounder / 5 & 10 joule beacon combination units
Certification ATEX, IECEx, TR CU, INMETRO, CCOE
Area classification Zone 1, 2, weatherproof
ATEX/IEC classification Ex II 2G, Ex de IIB T4 Gb
Approvals Russian fire approval, ABS
Certified temperature -50°C to +70°C*
Ingress protection IP66 & IP67
Material Corrosion free GRP
Entries Up to 2 x M20, M25, ½” NPT or ¾” NPT
Weight 6.5kg
Voltage 24-48Vdc, 110-254Vac
Sound output Max: 116dB*, 1m (±3dB)
Tones 27
Stages 2*
Light source Xenon
Options Tube energy, flash rate, lens colour, labels,
telephone initiate, relay initiate, independent
operation, Earth continuity, special tones, EOL
resistor, body colour
320mm
Ø124mm 206.5mm
*Model dependent
49EATON signalling and alarms product overview
DB3B/SM87HXB
Ex d sounder / 5 joule beacon combination unit
Certification ATEX, IECEx, cULus, TR CU, CQST, INMETRO, CCOE
Area classification Zone 1, 2, 21, 22, weatherproof
ATEX/IEC classification Ex II 2GD, Ex d IIC T4/T5/T6 Gb
Ex tb IIIC T135°C/T100°C/T85°C Db*
UL/NEC classification Class I, Div. 1, Groups C, D
Approvals SIL1, Russian fire approval
Certified temperature -55°C to +70°C
Ingress protection IP66 & IP67, NEMA 4X & 6
Materials Beacon body: stainless steel or alloy
Sounder body: corrosion free GRP
Flare: thermoplastic
Entries Up to 3 x M20 or ½” NPT customer entries
Note: Customer entries are in the beacon
Voltage 24-48Vdc, 110-254Vac
Sound output Max: 122dB*, 1m (±3dB)
Tones 28
Stages 3
Light source Xenon
Options Body, lens & flare colour, lens guard, flash rate,
earth continuity, tel. initiate, flare type, labels
220mm
420mm
Hazardous area status lights and combination units
DB3B/XB11
Ex d sounder / 5 joule beacon combination unit
Certification ATEX, IECEx, cULus, TR CU, CQST, INMETRO, CCOE
Area certification Zone 1, 2, 21, 22, weatherproof
ATEX/IEC classification Ex II 2GD, Ex d IIB T4/T5/T6 Gb
Ex tb IIIC T135°C/T100°C/T85°C Db*
UL/NEC classification Class I, Div. 2, Groups C, D
Approvals Russian fire approval
Certified temperature -55°C to +70°C
Ingress protection IP66 & IP67, NEMA 4X & 6
Materials Body: corrosion free GRP. Flare: thermoplastic
Entries 1 x M20 or ½” NPT customer entry
Note: Customer entries are in the beacon
Voltage 24-48Vdc, 110-240Vac
Sound output Max: 122dB*, 1m (±3dB)
Tones 28
Stages 3
Light source Xenon
Options Body, lens & flare colour, lens guard, flash rate,
earth continuity, tel. initiate, flare type, labels
220mm
490mm
*Model dependent
50 EATON Signalling and alarms Product overview
Hazardous area status lights and combination units
DB1P/SM87HXB
Ex d sounder / 5 joule beacon combination unit
Certification ATEX, IECEx, cULus, TR CU, CCOE
Area classification Zone 1, 2, weatherproof
ATEX/IEC classification Ex II 2G, Ex d IIB T5/T6
UL/NEC classification Class I, Div. 1, Groups C, D
Approvals SIL1
Certified temperature -25°C to +70°C
Ingress protection IP66, NEMA 4X
Materials Stainless steel or alloy
Entries Up to 3 x M20 or ½” NPT customer entries
Note: Customer entries are in the beacon
Voltage 24-48Vdc, 110-240Vac
Sound output Max: 110dB*, 1m (±3dB)
Tones 27
Stages 2
Light source Xenon
Options Body & lens colour, lens guard, flash rate, earth
continuity, tel initiate, number of sounder stages,
labels
228mm
351mm
*Model dependent
SM87SL
5 joule Ex d xenon and LED status light
Certification ATEX, IECEx, cULus*, CSA*, TR CU, CQST*,
INMETRO
Area classification Zone 1, 2, 21, 22, weatherproof
ATEX/IEC classification Xenon: Ex II 2GD, Ex d IIC T5/T6 Gb
Ex tb IIIC T95°C/T80°C/T65°C Db
Fluorescent: Ex II 2GD, Ex d IIC T6 Gb
Ex tb IIIC T85°C Db
Filament: Ex II 2GD, Ex d IIC T3/T4/T5/T6 Gb
Ex tb IIIC T155°C/T130°C/100°C/
T85°C Db
LED: Ex II 2GD, Ex d IIC T6 Gb
Ex tb IIIC T70°C Db
UL/NEC classification Class I, Div. 1, Groups C, D
Class I, Zone 1, Aex d IIB, Exd IIB
Approvals Russian fire approval
Certified temperature -55°C to +70°C*
Ingress protection IP66 & IP67, NEMA 4X & 6
Material Stainless steel or alloy
Entries Up to 3 x M20, M25, ½” NPT or ¾” NPT
Weight See datasheet
Voltage 24-48Vdc, 110-254Vac*
Light source Xenon, filament, fluorescent, LED
Number of ways Up to 5
Options Lens colour, LED colour, lens guard, tag/duty label,
telephone initiate, relay initiate, EOL resistor, body
colour
3 way shown 3 way shown
(A) 175 ±3
(S) 168
3
170mm
375mm
51EATON Signalling and alarms Product overview
Hazardous area status lights and combination units
XB11SL
5 joule Ex d status light
Certification ATEX, IECEx, cULus, TR CU, CQST, INMETRO
Area classification Zone 1, 2, 21, 22, weatherproof
ATEX/IEC classification Ex II 2GD, Ex d IIB T4/T5/T6 Gb
Ex tb IIIC T110°C/T85°C/T70°C Db
UL/NEC classification Class I, Div. 2, Groups C, D
Class I, Zone 1, AEx d IIB, Ex d IIB
Approvals Russian fire approval, CSFM
Certified temperature -55°C to +70°C
Operating temperature -55°C to +70°C
Ingress protection IP66 & IP67
Material Corrosion free GRP
Entries 1 x M20 or ½” NPT
Weight See datasheet*
Voltage 24-48Vdc, 110-240Vac
Light source Xenon, filament, fluorescent
Number of ways Up to 5
Options Flash rate, lamp wattage, lens colour, lens guard,
earth continuity, tag/duty label, telephone initiate,
body colour
2 way shown 2 way shown
*Model dependent
Fluorescent operating temperature = -20°C
SL5
Ex e xenon, filament and LED status light
Certification ATEX, IECEx, CQST
Area classification Zone 1, 2, weatherproof
ATEX/IEC classification Xenon: Ex II 2G, Ex e mb IIC T4 Gb
Filament: Ex II 2G, Ex e IIC T3 Gb
LED: Ex II 2G, Ex e mb IIC T4 Gb
Certified temperature Xenon: -40°C to +55°C
Filament: -40°C to +55°C
LED: -40°C to +45°C
Ingress protection IP66 & IP67
Material Corrosion free GRP
Entries Up to 2 x M16, M20 or 1 x M25, M32
Weight 1.2kg per way
Voltage 12-48Vdc*
Light source Xenon, filament, LED
Number of ways Up to 5
Options Light source, tag & duty labels, body colour
4 way shown 3 way shown
52 EATON signalling and alarms product overview
Hazardous area status lights and combination units
SL15
5, 10 & 15 joule Ex d xenon and LED status light
Certification ATEX, IECEx, cULus
Area classification Zone 1, 2, 21, 22, weatherproof
ATEX/IEC classification Xenon: Ex II 2GD, Ex db IIC T4/T5/T6 Gb
Ex tb IIIC T135°C/T100°C/T85°C Db
Filament: Ex II 2GD, Ex db IIC T3/T4 Gb
Ex tb IIIC T200°C/T135°C Db
LED: Ex II 2GD, Ex db IIC T5/T6 Gb
Ex tb IIIC T100°C/T85°C Db
UL/NEC classification Class II, Div. 2, Groups F, G
Certified temperature -55°C to +70°C
Ingress protection IP66 & IP67, NEMA 4X & 6
Material Corrosion free GRP
Entries Up to 2 x M20, M25, ½” NPT or ¾” NPT
Weight See datasheet
Voltage 24-48Vdc, 110-254Vac*
Light source Xenon, filament, LED
Number of ways Up to 4
Options Flash rate (xenon & LED), light source, tube energy
(xenon), lens guard, tag & duty label, body colour
208mm
197mm
197mm
250mm
*Model dependent
XB12SL
21 joule xenon and steady Ex d status light
Certification ATEX, IECEx, cULus, TR CU, INMETRO
Area classification Zone 1, 2, weatherproof
ATEX/IEC classification Xenon: Ex II 2G, Ex d IIB T4/T5/T6 Gb
Filament: Ex II 2G, Ex d IIB T3/T4/T5 Gb
Fluorescent: Ex II 2G, Ex d IIB T4/T5/T6 Gb
Rotating: Ex II 2G, Ex d IIB T3/T4 Gb
UL/NEC classification Class I, Div. 2, Groups C, D
Class I, Zone 1, AEx d IIB, Ex d IIB
Approvals Russian fire approval, CSFM
Certified temperature Xenon: -55°C to +70°C
Filament: -55°C to +55°C
Fluorescent: -20°C to +70°C
Ingress protection IP66 & IP67, NEMA 4X & 6
Material Corrosion free GRP
Entries 1 x M20 or ½” NPT
Weight See datasheet
Voltage 24Vdc, 110-240Vac
Light source Xenon, filament, fluorescent, rotating tungsten
halogen
Number of ways Up to 5
Options Flash rate, lamp wattage, lens colour, lens guard,
earth continuity, tag/duty label, telephone initiate,
body colour
53EATON signalling and alarms product overview
DB12/XB13 DB15/XB13 AXL04 AXL05 AXL08
HPL HPLB SAM SL 4 SL 7
Page 55 Page 55 Page 55 Page 56 Page 56
Page 56 Page 57 Page 57 Page 57
Industrial status lights and combination units
54 EATON Signalling and alarms Product overview
DB12/XB13
Weatherproof sounder / 10 joule beacon combination unit
Area classification Weatherproof
Operating temperature -40°C to +70°C
Ingress protection IP66 & IP67
Materials Body: corrosion free GRP. Lens: polycarbonate
Entries Up to 2 x M20 customer entries
Note: Customer entries are in the beacon
Voltage 12-24Vdc, 115-230Vac
Sound output Max: 110dB, 1m (±3dB)
Tones 27
Stages 2*
Light source Xenon
Options Body & lens colour, lens guard, telephone & relay
initiate, single & dual flash mode, tag & duty
labels
200mm
300mm
AXL04
Weatherproof sounder / 2 joule beacon combination unit
Area classification Weatherproof
Operating temperature -25°C to +70°C
Ingress protection IP66
Materials Impact resistant ABS
Weight 0.5kg
Voltage 9-60Vdc, 115-230Vac
Sound output Max: 105dB, 1m (±3dB)
Tones 32
Stages 2
Light source Xenon
Options Lens colour
136mm
119mm
137mm
DB15/XB13
Weatherproof sounder / 10 joule beacon combination unit
Area classification Weatherproof
Operating temperature -40°C to +70°C
Ingress protection IP66 & IP67
Materials Body: corrosion free GRP. Lens: polycarbonate
Entries Up to 2 x M20 customer entries
Note: Customer entries are in the beacon
Voltage 12-48Vdc, 115-230Vac
Sound output Max: 117dB, 1m (±3dB)
Tones 27
Stages 2*
Light source Xenon
Options Body & lens colour, lens guard, telephone & relay
initiate, single & dual flash mode, tag & duty
labels
420mm
220mm
Industrial status lights and combination units
*Model dependent
55EATON Signalling and alarms Product overview
AXL08
Weatherproof sounder / 2 & 3.6 joule beacon combination units
Area classification Weatherproof
Operating temperature -25°C to +70°C
Ingress protection IP66
Materials Impact resistant ABS
Weight 1.8kg - 2.8kg*
Voltage 18-30Vdc, 230Vac
Sound output Max: 120dB, 1m (±3dB)
Tones 42
Stages 3
Light source Xenon
Options Lens colour
168mm
155mm
212mm
HPL/HPLB
Weatherproof mini hooter with warning light
Area classification Weatherproof
Operating temperature -20°C to +50°C
Ingress protection IP43
Material Impact resistant ABS
Weight 0.185Kg
Voltage 12-24Vdc, 230Vac
Sound output Max: 92dB, 1m (±3dB)
Light source HPL: 7W Filament. HPLB: 1 joule xenon
Options Light source, lens colour
64mm
80mm
209mm
Industrial status lights and combination units
AXL05
Weatherproof sounder / 2.5 joule beacon combination unit
Area classification Weatherproof
Operating temperature -25°C to +70°C
Ingress protection IP66
Materials Impact resistant ABS
Weight 0.8kg
Voltage 9-60Vdc, 115-230Vac
Sound output Max: 112dB, 1m (±3dB)
Tones 32
Stages 2
Light source Xenon
Options Lens colour
132mm
165mm
173mm
*Model dependent
56 EATON signalling and alarms product overview
Industrial status lights and combination units
*Model dependent
SAM
Weatherproof traffic light
Area classification Weatherproof
Operating temperature -20°C to +60°C
Ingress protection IP54
Material UV Resistant plastic
Entries Via the bracket
Weight 2.0kg - 4.7kg*
Voltage 24Vdc, 230Vac
Light source Filament, LED
Number of ways Up to 3
Options Light source, Lens colours, number of ways
675
265
530
147
25,8624 mm
265
14,8670 mm
85
78,7654 mm
26,2476 mm
19,6779 mm
37,7681 mm
147
15,3316 mm
85
21,6644 mm
185
21,5525 mm
25,8624 mm
265
26,3461 mm
265
77,0000 mm
26,1331 mm
51,5218 mm
790mm
265mm
935mm
135mm 290mm
SAM weatherproof
Trac Light LD
SL 7
Weatherproof stack light
Area classification Weatherproof
Operating temperature -30°C to +60°C
Ingress protection IP66
Material Polycarbonate
Entries Various depending on base
Weight Various depending on configuration
Voltage 18-250*Vdc, 110-250*Vac
Light source LED
Number of ways Up to 5
Options Lens colour, flashing or continuous, mounting
base, light source, sounder, SmartWire-DT
SL 4
Weatherproof stack light
Area classification Weatherproof
Operating temperature -30°C to +60°C
Ingress protection IP66
Material Polycarbonate
Entries Various depending on base
Weight Various depending on configuration
Voltage 18-250*Vdc, 110-250*Vac
Light source LED
Number of ways Up to 5
Options Lens colour, flashing or continuous, mounting
base, light source, sounder, SmartWire-DT
Ø72
340
Ø72
373
57EATON signalling and alarms product overview
Eaton offers a range of analogue and VOIP telephones from
Funke+Huster Fernsig (FHF).
Eaton provides a wide range of Hazardous Area and Industrial
Telephones tested in harsh environments such as chemical plants,
off-shore platforms and remote gas generating stations.
The hazardous area phones are offered with global ATEX, IECEx,
INMETRO, UL and TR CU approvals.
Explosion proof telephones and accessories
ExResistTel ExResistTel MB ExResistTel IP2 FernTel 3 Zone 2
FernTel IP Z2 Ex-Howl-Call
telephone
ResistTel
accessories
TWIN-EExII
Secondary telephone
bell
Telephone call relay
mTAR
Page 60 Page 60 Page 60 Page 61
Page 61 Page 61 Page 62 Page 62
Page 62 Page 62
58 EATON signalling and alarms product overview
Proven technology from Eaton ensures the FHF
ExResistTel IP2 is the ideal unit for all kinds of adverse
weather conditions at a wide variety of diverse facilities.
The housing is made of impact and shock resistant
fiberglass-reinforced polyester. Its robust design is perfect
to meet the latest requirements demanded of VoIP
telephones for use in hazardous areas.
The ExResistTel IP2 allows efficient operation by
providing especially convenient features and benefits
such as an illuminated heated display, a V4A keypad
suitable for use with industrial gloves, and handsfree
communication. It also supports all features of the H.323
SIP(SIP over UDP), TSIP(SIP over TCP) and SIPS(SIP over
TLS). A headset, available as accessory equipment, can
be easily connected to the telephone.
FHF ExResistTel IP2
ATEX and IECEx certified
Ringing volume of 95dB(A)
IP66 protection
Operating temperature -40°C to +60°C
Illuminated, heated LCD display
Intelligent, user friendly menu structure
Handsfree communication
Standard H.323, SIP, TSIP, SIPS protocols
Power supply: Power over Ethernet or external supply
Simply connected to a single 10/100 BASE T Ethernet LAN, RJ45
59EATON signalling and alarms product overview
ExResistTel MB
Explosion proof robust telephone
Certification ATEX, IECEx,
ATEX/IEC classification Ex II 2G, Ex e mb [ib] IIC T6/T5 Gb
Ex II 2D, Ex tb [ib] IIIC T80°C/T100°C Db
Certified temperature -25°C to +60°C (T5)
-25°C to +40°C (T6)
Ingress protection IP66
Material Corrosion-free GRP
Weight 5.5kg
Options Accessories, headset, earpiece, ExTWIN sounder/
beacon, secondary ex sounder, certification
ExResistTel IP2
Explosion proof IP telephone
Certification ATEX, IECEx, INMETRO, TR CU
ATEX/IEC classification II 2G Ex e ib [ib] mb IIC T4 Gb, III 2D Ex ib [ib] tb
IIIC T 135 °C Db
Certified temperature -40°C to +60°C
Ingress protection IP66
Material Corrosion-free GRP
Weight 5kg approx
Protocol H.323, SIP, TSIP, SIPS
Power supply Power over Ethernet
Options Certification, headset
ExResistTel
Explosion proof robust telephone
Certification ATEX, IECEx,INMETRO, TR CU, UL
ATEX/IEC classification Ex II 2G, Ex e mb [ib] IIC T6/T5 Gb
Ex II 2D, Ex tb [ib] IIIC T80°C/T100°C Db
Certified temperature -25°C to +60°C T5
-25°C to +40°C T6
Ingress protection IP66
Material Corrosion-free GRP
Weight 5.5kg
Options Body colour,certification, keypad & display, acces-
sories; headset, earpiece, TWIN sounder/beacon,
secondary sounder
Explosion proof telephones and accessories
254mm
227mm
227mm
264
mm
254mm
227mm
60 EATON signalling and alarms product overview
Explosion proof telephones and accessories
FernTel 3 Zone 2
Explosion proof wall and desk telephone
Certification ATEX, IECEx, INMETRO
ATEX/IEC classification Ex II 3G, Ex nA ic IIC T5 Gc
Ex II 3D, Ex tc ic IIIC T80°C Dc
Certified temperature -20°C to +55°C
Display: -10°C to +55°C
Ingress protection IP65
Material Polycarbonate
Entries Up to 2 x M20
Weight 2.3Kg
Options Body colour, spiral/armed cord, with/without
display and without keypad, stabilizer bracket
Explosion proof telephones and accessories
FernTel IP Z2
Explosion proof wall and desk IP telephone
Certification ATEX, IECEx,INMETRO, UL
ATEX/IEC classification Ex II 3G, Ex nA ic IIC T5 Gc
Ex II 3D, Ex tc ic IIIC T80°C Dc
Certified temperature -20°C to +55°C
Ingress protection IP65
Material Polycarbonate
Weight 2.34kg approx
Protocol H.323, SIP, TSIP, SIPS
Power supply Power over Ethernet
Options Body colour,certification, spiral cord/armoured
cord, stabiliser bracket
191mm
293
mm
Ex-howl-call telephone
Sound powered telephone for use in Zone 1
Certification ATEX
ATEX/IEC classification Ex II 1G, Ex ia IIC T6 Ga
Ex I M1, Ex ia I Ma
Certified temperature -20°C to +40°C
Ingress protection IP54
Material Plastic
Weight approx. 1,3 Kg
Options Accessories; snap-in plug, coupling socket, wall
socket, prick pincers, flat-band cable
370mm
70mm 128mm
191mm
293
mm
61EATON signalling and alarms product overview
Explosion proof telephones and accessories
TWIN-EExII
Ex em sounder / 0.9 joule beacon combination unit
Certification ATEX
Area classification Zone 1, 2
ATEX/IEC classification Ex II 2G, Ex e mb [ib] T6/T5/T4 Gb
Certified temperature -20°C to +60°C*
Ingress protection IP66
Material Housing: Aluminium die cast, polycarbonate
Entries 2 x M20
Weight 1.5kg
Voltage 230Vac
Sound output Max: 90dB, 1m (±3dB)
Tones 8
Light source Xenon
Options Lens colour
150mm
130mm
Ex-ResistTel accessories
Certification ATEX, TR CU
ATEX/IEC classification II 2 G EEx em[ib] IIC T5/T6
Certified temperature -25°C to +60°C*
Ingress protection Secondary receiver set: IP54
Headset: IP20
Material GRP
Weight Headset approx. 1 kg
Ex ResistTel with Headset
Ex ResistTel with second receiver
Explosion proof secondary telephone bell
For use as a secondary ringer
Certification ATEX, TR CU, INMETRO
ATEX/IEC classification II 2G Ex e ib mb IIC T6
Certified temperature -20°C to +40°C
Ingress protection IP66
Material Aluminium
Weight 0.5kg approx
Options Certification
117
150mm
130mm
137mm
*Model dependent
62 EATON signalling and alarms product overview
Explosion proof telephone call relay mTAR
Connects signalling devices with telephones
Certification ATEX, IECEx, INMETRO
ATEX/IEC classification Ex II 2G, Ex e ib mb IIC T4 Gb
Ex II 2D, Ex tb IIIC T135°C Db
Certified temperature -40°C to +70°C
Ingress protection IP66
Material GRP
Weight 0.5kg approx
Voltage 230VAC 5A (max. 100W)
Options Call break bridging
190mm
114mm
75mm
210mm
Explosion proof telephones and accessories
63EATON signalling and alarms product overview
Industrial telephones and accessories
ResistTel ResistTel MB ResistTel IP FernTel
FernTel IP VoIP InduTel InduTel FernTel W & W ZB
IntellyCom station TAR 21 Call relay AWS signalling Protection housing
Page 65 Page 65 Page 65 Page 66
Page 66 Page 66 Page 66 Page 67
Page 67 Page 67 Page 67 Page 68
Protection hoods WP Twin LED Secondary telephone
bell
Page 68 Page 68 Page 68
64 EATON signalling and alarms product overview
Industrial telephones and accessories
ResistTel
Weatherproof robust telephone
Certification Weatherproof
Operating temperature -25°C to +60°C T5
Ingress protection IP66
Material Corrosion-free GRP
Weight 5.5kg
Options Body colour,keypad & display, accessories;
headset, earpiece, loudspeaker set, TWIN sound-
er/beacon, protection hood, secondary sounder
ResistTel MB
Weatherproof robust telephone
Certification Weatherproof
Operating temperature -25°C to +60°C
Ingress protection IP66
Material Corrosion-free GRP
Weight 5.5kg
Options Accessories
ResistTel IP
Weatherproof IP telephone
Certification Weatherproof
Operating temperature -40°C to +70°C
Ingress protection IP66
Material Corrosion-free GRP
Weight 5kg
Protocol H.323, SIP, TSIP, SIPS
Power supply Power over Ethernet
Options Body colour, spiral cord/armoured cord, stabiliser
bracket, relay, 2nd Lan
227mm
254mm
195
201
195
220
11
16
133
227mm
254mm
Ø 8,5
Ø 8,5
M6x1
M6x1
195
220
201
195
11
~ 263
16
~ 133
Ø 8,5
Ø 8,5
M6
M6
227mm
254mm
65EATON signalling and alarms product overview
Industrial telephones and accessories
FernTel
Weatherproof wall and desk telephone
Certification Weatherproof
Operating temperature -20°C to +55°C
Display: -10°C to +55°C
Ingress protection IP65
Material Polycarbonate
Entries Up to2 x M20 and2 x M25
Weight 2.3Kg
Options Body colour, spiral cord/armoured cord, stabiliser
bracket
FernTel IP
Weatherproof wall and desk IP telephone
Certification Weatherproof
Operating temperature -20°C to +60°C
Ingress protection IP65
Material Polycarbonate
Weight 2.34kg approx
Protocol H.323, SIP, TSIP, SIPS
Power supply Power over Ethernet
Options Body colour, spiral cord/armoured cord, stabiliser
bracket
VoIP InduTel wall telephone
IP telephone with protection door
Area classification Weatherproof
Operating temperature -40°C to +55°C
Ingress protection IP66
Material Polycarbonate
Weight 2.3kg approx
Protocol SIP
Power supply Power over Ethernet
Options Housing colour
458mm
210mm
293mm
191mm
191mm
293mm
Analogue InduTel wall telephone
Weatherproof telephone with protection door
Certification Weatherproof
Operating temp -25°C to +55°C
Ingress protection IP66
Material Polycarbonate
Weight 2.3kg approx
Options Keypad, transparent door, optical call indicator
458mm
210
mm
66 EATON signalling and alarms product overview
IntellyCom Station
Intercom station
Area classification Weatherproof
Operating temp -40°C to +60°C
Ingress protection IP66
Material Stainless steel
Weight 1.5kg approx
Options With/without housing, one/three dialling keys 205mm
60mm
110mm
Industrial telephones and accessories
FernTel W and FernTel W ZB
Built in telephone
Area classification Weatherproof
Operating temp -25°C to +60°C
Ingress protection IP65
Material Polycarbonate
Options Illuminated keypad, steel armoured handset cord,
sprial cord, without/without keypad
100mm
285mm
100mm
285mm
TAR 21 call relay
Connects signalling devices with telephones
Area classification Weatherproof
Operating temp -20°C to +60°C
Ingress protection IP55
Material Aluminium
Weight 0.75kg
Options With call break bridging
130mm
117mm
TAR21 LD
AWS signalling bell
Weatherproof bell with telephone relay
Area classification Weatherproof
Operating temperature -20°C to +60°C
Ingress protection IP55
Material Housing: aluminium. Dome: steel
Entries 2 x M20
Weight 1.8kg - 3.3kg*
Voltage 230Vac
Sound output Max: 110dB, 1m (±3dB)*
Options Dome size
80
~ 266
Ø
150
366mm
118mm
Ø250mm
AWS Bell
67EATON signalling and alarms product overview
*Model dependent
Industrial telephones and accessories
Protection housing
Area classification Weatherproof
Operating temp From -50°C to + 70°C*
Material Plastic, GRP, sheet steel, V4A
Weight Depends on material
dB attenuation 16 & 26*
Options Material, colours
Protection hoods
Area classification Weatherproof
Material GRP, DIN 5510, Class S4, Perforated plate metal,
plastic, sheet steel* and stainless steel*
Weight Depends on material
Noise insilation 25dB
Options Material, colours, console
360
460
6,50
Rückseite mit Lochbild
400mm
200
500mm
535
600
420
510
262
Protection hood and housing GRP
240mm
808mm
985mm
WP Twin LED
LED (Telephone) sounder / beacon combination unit
Area classification Weatherproof
Operating temperature -40°C to +65°C*
Ingress protection IP66
Material Seawater resistant aluminium body
Entries 2 x M20
Weight 1.8kg
Voltage 24Vdc, 115-230Vac
Sound output Max: 102dB, 1m (±3dB)
Tones 8
Light source LED
Options Lens colour (clear, red, yellow green, blue)
148mm
144mm
150mm
130mm
Secondary telephone bell
For use as a secondary ringer
Operating temperature -20°C to +40°C
Ingress protection IP66
Material Aluminium
Weight 0.5kg approx
117
150mm
130mm
137mm
68 EATON signalling and alarms product overview
Introducing the WP Twin LED
Eaton is pleased to announce the launch of the new TWIN LED audio visual signalling device using high
intensity LED technology. The unit is designed to be used as a stand alone sounder beacon combination
unit or in conjunction with a telephone.
Designed to provide both audio and visual signalling and warning in high noise environments, the TWIN LED permits
clear audio and visually signalling in industrial environments.
The TWIN LED offers both improved audio performance with a higher ring volume up to 102 db(A) and greater
brightness and visibility by using high power LED technology instead of Xenon flash tubes.
The TWIN LED has an ingress protection of IP66 and is designed to withstand the harsh environments onshore,
offshore and marine.
As the mounting dimensions are unchanged from previous model, it means it is reverse compatible and can be simply
used to replace and upgrade current installations.
High intensity LED technology
Long life LED technology
High output volume 102dB(A)
Available with 5 different lens colours
Power supply options 24 VDC, or 230 VAC (103 -253 VAC)
Ingress protection IP66
Operating temperature -40°C to +65°C
69EATON signalling and alarms product overview
Eaton offers standard and bespoke control and distribution units for
harsh and hazardous areas.
The control units are designed with convenient operation, safety and
reliability in mind. As a leading manufacturer of hazardous area and
explosion proof equipment, Eaton can provide hazardous and safe area
control units in a range of dimensions to suit your required specification.
Hazardous area control and distribution
HD1 SM87JB JB10 & JB11 GP & JL GHG 74/44
GHG 411 81 GHG 411 82 GHG 411 83 EL 101 D Surge arrestor DUS
Page 71 Page 71 Page 71 Page 72 Page 72
Page 73 Page 73 Page 73 Page 74 Page 74
70 EATON signalling and alarms product overview
SM87JB
Ex d Junction box
Certification ATEX, IECEx
Area classification Zone 1, 2, 21, 22, weatherproof
ATEX/IEC classification Ex II 2GD, Ex d IIC T4/T5/T6 Gb
Ex tb IIIC T135°C/T100°C/T85°C Db
Certified temperature -55°C to +85°C
Ingress protection IP66 & IP67
Material Stainless steel or alloy
Entries Up to 4 x M20, M25
Weight 3.1kg
Options Terminals, tag/duty label, telephone initiate, relay
initiate, resistors, diodes, body colour
JB10 & JB11
Ex e Junction boxes
Certification ATEX, IECEx, cULus, CCOE
Area classification Zone 1, 2, weatherproof
ATEX/IEC classification Ex II 2G, Ex e IIC T4/T5/T6
UL/NEC classification Class I, Div. 2, Groups A, B, C, D
Class I, Zone 1, AEx e IIC Ex e IIC
Certified temperature -50°C to +55°C
Ingress protection IP66 & IP67, NEMA 4X & 6
Material Corrosion free GRP
Entries Up to 2 x M16, M20, M25, M32, ½” NPT or ¾”
NPT per face
Weight JB10: 1.1kg. JB11: 1.8kg
Options Terminals, earth continuity, tag label, body colour
HD1
Ex d, Ex e & Ex ia Heat detectors
Certification ATEX, IECEx, cULus, TR CU, CCOE
Area classification Zone 1, 2, 21, 22, weatherproof
ATEX/IEC classification Ex II 2GD, EEx d IIB+H2 T6
Ex II 2GD, Ex d IIC Ex tD A21 T85°C
Ex II 2G, EEx em II T6 (T4 with diodes/resistors)
Ex II 1G, Ex ia IIC T6 Ga (T4 with diodes/resistors)
UL/NEC classification Class I, Div. 2, Groups A, B, C, D
Class I, Zone 2, Group IIC
Approvals SIL2, Russian fire approval, ABS
Certified temperature Ex d/Ex e/UL: -20°C to +55°C
ATEX/TR CU: -20°C to +125°C*
Ex ia: -55°C to +55°C
Ingress protection IP66 & IP67, NEMA 4X & 6
Material Ex d: marine grade alloy
Ex ia/EEx em/UL: corrosion free GRP
Entries 2 x M20
Voltage 1.1kg - 2.0kg*
Options Temperature setting ,tag & duty label, probe
guard, monitoring resistors and diode, body colour
130mm
110mm
Hazardous area control and distribution
225.5mm
110mm
130mm 165mm
Exd version
Exia / Exem version
87.5±2 (A)
77±2 (S)
67±2 (S)
76.5±2 (A)
36.5±2 (ALUMINIUM)
30±2 (STAINLESS STEEL)
122mm
*Model dependent
150mm
150mm
JB10
JB11
71EATON signalling and alarms product overview
305mm
265mm
GHG 74/44
Ex e Control stations and terminal boxes
Certification ATEX, IECEx, TR CU, cCSAus
Area classification Zone 1, 2, 21, 22, weatherproof
ATEX/IEC classification Ex II 2G, Ex e IIC T4/T5/T6 Gb / Ex e ib [ia/ib] IIC
T4/T5/T6 Gb
Ex II 2D, Ex tb IIIC T95°C/T80°C Db
UL/NEC classification Class I, Div. 2, Groups A, B, C, D
Class II, Div. 1, Groups E, F, G
Class II, Div. 2, Groups F, G
Class I, Zone 1, AEx e II, Ex e II
Certified temperature Normal: -20°C to +40°C
Optional: -55°C to +55°C
Ingress protection IP66
Material Corrosion free GRP or stainless steel
Entries Multiple entries per face*
Weight See datasheet*
Options Terminals, enclosure size
GP & JL
Ex d Range of custom build control panels
Certification ATEX, IECEx
Area classification Zone 1, 2, 21, 22, weatherproof
ATEX/IEC classification JL, GP1 & GP3: Ex II 2G, Exd IIB
GP2 & GP4: Ex II 2GD Exd IIB Gb, Ex tb IIIC Db
Certified temperature GP1 & GP3: -40°C to +55°C
GP2: -40°C to +55°C
GP4: -55°C to +60°C
JL4: -55°C to +55°C
Ingress protection GP1 & JL4: IP65
GP2, GP3 & GP4: IP66
Material Cast iron, stainless steel or alloy
Entries M16, M20, M25, M32, M40, M50, M63 or M75
Weight GP1: 149kg
GP2: 70kg
GP3: 182kg
GP4: 146kg
JL4 40kg
Options Isolators, relays, contactors, transformers, MCBs,
fuses, rotary switches, printed circuit boards,
invertors, PLCs, meters, indicators, pushbuttons,
potentiometers, RCDs (ELCBs), timers, IS
components, clients products
Hazardous area control and distribution
*Model dependent
J24 shown
72 EATON signalling and alarms product overview
GHG 411 82
Ex e Control station
Certification ATEX, IECEx, TR CU, cULus, INMETRO
Area classification Zone 1, 2, 21, 22, weatherproof
ATEX/IEC classification Ex e II T6, Ex e ib IIC T6
Ex ed IIC T6 or Ex ed ib IIC T6
UL/NEC classification Class I, Div. 2, Groups A, B, C, D
Class II, Div. 1, Groups E, F, G (Canada)
Class II, Div. 2, Groups F, G
Class I, Zone 1, AE x e IIC T6, Ex e II T6
Certified temperature Normal: -20°C to +40°C
Optional: -55°C to +55°C
Ingress protection IP66
Material Polyamide
Entries 1 x M20
Weight 0.5kg*
Options Pushbuttons, emergency stop, rotary switches
block, potentiometer, lamps, 3 position key switch,
gold contact block
85mm
155mm
Hazardous area control and distribution
GHG 411 81
Ex e Control station
Certification ATEX, IECEx, TR CU, cULus, INMETRO
Area classification Zone 1, 2, 21, 22, weatherproof
ATEX/IEC classification Ex II 2G, Ex ed ib m IIC T6
Ex II 2D, Ex tD A21 T80°C
UL/NEC classification Class I, Div. 2, Groups A, B, C, D
Class II, Div. 1, Groups E, F, G (Canada)
Class II, Div. 2, Groups F, G
Class I, Zone 1, AE x e IIC T6, Ex e II T6
Certified temperature Normal: -20°C to +40°C
Optional: -55°C to +55°C
Ingress protection IP66
Material Polyamide
Entries 1 x M20
Weight 0.5kg*
Options Pushbuttons, emergency stop, rotary switches
block, potentiometer, lamps, 3 position key switch,
gold contact block
85mm
115mm
*Model dependent
GHG 411 83
Ex e Control station
Certification ATEX, IECEx, TR CU, cULus, INMETRO
Area classification Zone 1, 2, 21, 22, weatherproof
ATEX/IEC classification Ex e II T6, Ex e ib IIC T6
Ex ed IIC T6 or Ex ed ib IIC T6
UL/NEC classification Class I, Div. 2, Groups A, B, C, D
Class II, Div. 1, Groups E, F, G (Canada)
Class II, Div. 2, Groups F, G
Class I, Zone 1, AE x e IIC T6, Ex e II T6
Certified temperature Normal: -20°C to +40°C
Optional: -55°C to +55°C
Ingress protection IP66
Material Polyamide
Entries 1 x M20
Weight 0.5kg*
Options Pushbuttons, emergency stop, rotary switches
block, potentiometer, lamps, 3 position key switch,
gold contact block
85mm
195mm
73EATON signalling and alarms product overview
EL 101 D
Cast iron pendulum switch
Area classification Weatherproof
Operating temperature -25°C to +60°C
Ingress protection IP66
Material Cast iron
Entries 1 x M20
Weight 10.5kg
Voltage 230Vac
DUS
1kV discharge surge arrester
Ingress protection IP00
Material Housing: polyester
Insulating layer: mica
Options Spark-over voltages
Industrial control and distribution
74mm
218mm
Ø156mm
44
Ø52mm
32.5mm
*Model dependent
74 EATON signalling and alarms product overview
Public Alarm & General Systems
(PAGA)
Designed to enhance modern
communication philosophies, the
SonixTM PA/GA system includes a
highly sophisticated yet simplified
architecture that removes the need for
lengthy engineering cycles, bespoke
and costly software, custom field
engineering or expensive onsite
support. We are able to offer fully
compliant communications solutions
to meet the most demanding
applications for onshore, offshore and
industrial installations.
Telephones
Gitiesse and FHF supply a full range
of automatic and sound powered
telephones suitable for any kind
of application: IP and analogue,
weatherproof proof and explosion
protected. Supplementary audio and
optical devices are also available as an
option.
Control and distribution
At MEDC we offer standard and
bespoke control and distribution units
for harsh and hazardous environments.
As a leading manufacturer of explosion
proof equipment, MEDC can provide
hazardous and safe area control units
in a range of dimensions to suit your
required specification.
Status lights & audible
and visual combination units
For use in situations where both
audible and visual awareness is
required together to alert operators
of a potential hazard. Customised
solutions from MEDC and FHF can
be designed and manufactured using
our sounders and beacons to suit the
specific needs of the customer.
Call points
Manual alarm call points are designed
for the purpose of raising an alarm
manually once verification of a fire
or emergency condition exists, by
operating the push button or break
glass the alarm signal can be raised.
Closed Circuit Television Stations
(CCTV)
HERNISTM, Oxalis and Yuhua lead
the way in developing advanced
camera-based surveillance systems
for marine and oil & gas installations
worldwide. Our solutions contribute to
increased efficiency and provide safety
for people and equipment in hazardous
areas and under extreme conditions.
Loudspeakers
The MEDC range of hazardous, heavy
duty, industrial and commercial
speakers are designed to meet the
requirements for public address,
voice alarm (evacuation) and
background music.
Audible alarms
MEDC and FHF’s range of audible
alarms are suitable for a wide array of
applications, feature a variety of tone
settings, and are designed to raise
the alarm in dangerous situations.
Traditional bells are also available.
Visual alarms
MEDC and FHF offer a range of
beacons and combination units
including flashing, steady-state
indicators and rotating units. These
may be used to warn of potential
hazards or indicate the status of plant
conditions, fire and gas alarms,
evacuation alerts and many more.
HAC products and solutions
75EATON signalling and alarms product overview
Hazardous area US products
SM87PB SM87BG PH1 PB BG
Page 78 Page 78 Page 78 Page 79 Page 79
XB11 XB15
LD15 Expertline LED SM87 HXB
Page 79 Page 80Page 80 Page 81Page 80
XB4 XB12 XB16 SM87LU1/LU3 FL4 & FB4
Page 81 Page 81 Page 82 Page 82 Page 82
FB15 DB1P DB3B DB5FB11 & FB12
Page 83 Page 83 Page 84 Page 84Page 83
Eaton offers a range of products specifically designed and
certified for use in the US and Canada.
This range of call points, signalling devices, telephones and
control panels is certified to UL and CSA standards and is
suitable for use in hazardous locations such as zone I and zone II.
76 EATON signalling and alarms product overview
DB3B/XB11
dGW21/dRGW21 DB4B DB16 DB3B/XB15
Page 84 Page 85 Page 85 Page 86
Page 86
DB3B/SM87HXB DB1/SM87HXB SM87SL XB11SL
SL15
Page 86 Page 87 Page 87 Page 87
Page 88
FernTel IP Analogue InduTel
Wall telephone
HD1
XB12SL Ex ResistTel
Page 88 Page 89
Page 89
Page 89
Page 88
JB10 & JB11 GHG 74/44 GHG 411 81 GHG 411 82
Page 90 Page 90 Page 90 Page 91
GHG 411 83
Page 91
dGH 21
Page 85
77
EATON signalling and alarms product overview
SM87PB
Hazardous location push button call point
Certification cULus, ULC, CSA
Area classification Hazardous locations, ordinary locations
UL/NEC classification Class 1, Div. 1, Groups C, D (CSA Ex ia also
includes groups A & B )
Class I, zone 1. Groups IIA, IIB
Approvals SIL2, ABS
Certified temperature -58°F to +158°F*
Ingress protection NEMA 4X & 6
Material Stainless steel or alloy
Entries Up to 4 x ½” NPT or ¾” NPT
Weight Stainless: 8.4lb. Alloy: 5.5lb
Switches 2 pole c/o (Up to 4 pole c/o available)
Options Switch action, labels, LED, EOL and series
resistors, diodes, 3 or 4 pole switches, colour
PH1
Hazardous location pull handle call point
Certification cULus
Area classification Hazardous locations, ordinary locations
UL/NEC classification Class I, Div. 1, Groups B, C, D
Class I, Div. 2, Groups A, B, C, D
Class II, Div. 2, Groups F, G
Class III
Class I, Zone 1, AEx d IIC, Ex d IIC
Certified temperature -58°F to +158°F
Ingress protection NEMA 4X & 6
Material Corrosion free GRP (UL Class I, Div. 1 Inner Cover:
316 stainless steel)
Entries Up to 2 x ½” NPT or ¾” NPT
Weight UL Class I, Div 2/ATEX/IECEx/UW: 5.8lb
UL Class I, Div. 1: 8.4lb
Switches 1 or 2 pole c/o
Options EOL and series resistors, diodes, labels, body
colour
SM87BG
Hazardous location break glass call point
Certification CSA
Area classification Hazardous locations, ordinary locations
UL/NEC classification Class 1, Div. 1. Groups A, B, C, D
Certified temperature -58°F to +158°F*
Ingress protection NEMA 4X & 6
Material Stainless steel or alloy
Entries Up to 4 x ½” NPT or ¾” NPT
Weight Stainless: 8.4lb. Alloy: 5.5lb
Switches 2 pole c/o (Up to 4 pole c/o available)
Options Switch action, labels, LED, EOL and series
resistors, diodes, 3 or 4 pole switches, colour
Hazardous area US products
4-3/4"
4-3/4"
4-3/4"
4-3/4"
7-7/8”
4-5/8”
*Model dependent
78 EATON signalling and alarms product overview
PB
Hazardous location push button call point
Certification cULus, CSA
Area classification Hazardous locations, ordinary locations
UL/NEC classification Class I, Div. 2, Groups A, B, C, D
Class II, Div. 2, Groups F, G
Class I, Zone 2
Approvals SIL2, ABS
Certified temperature -58°F to +131°F*
Ingress protection NEMA 4X & 6
Material Corrosion free GRP
Entries Up to 4 x ½” NPT
Weight 2.6lb
Switches 1 or 2 pole c/o
Options Labels, LED, EOL and series resistors, diodes, Earth
continuity, switch action, number of terminals,
colour
LD15
Hazardous location LED strobe
Certification cULus, ULC
Area classification Hazardous locations, ordinary locations
UL/NEC classification Class I, Div. 2, Groups A*, B*, C, D
Class II, Div. 2, Groups F, G
Class I, Zone 1, AEx d IIC* & IIB, Ex d IIB
Approvals SIL1 (1oo1) & SIL2 (1oo2)
Certified temperature -67°F to +158°F
Ingress protection NEMA 4X & 6
Material Corrosion free GRP
Entries Up to 3* x ½” NPT or ¾” NPT
Weight Direct: 7.7lb. Pipe: 6.8lb
Voltage 12-48Vdc, 110-254Vac
Light source LED
LED life 54,000 hours
Options Lens colour, lens guard, mounting, tag & duty
label, relay initiate, body colour
BG
Hazardous location break glass call point
Certification cULus
Area classification Hazardous locations, ordinary locations
UL/NEC classification Class I, Div. 2 Groups A, B, C, D
Class I, Zone 2
Approvals SIL2
Certified temperature -13°F to +131°F*
Ingress protection NEMA 4X & 6
Material Corrosion free GRP
Entries Up to 4 x ½” NPT
Weight 2.6lb
Switches 1 or 2 pole c/o
Options Labels, switches, LED, Lift flap, EOL and series
resistors, diodes, Earth continuity, plastic element,
break glass hammer, number of terminals, colour
Hazardous area US products
4-3/4”
4-15/16”
4-3/4”
4-15/6”
9-13/32”
150
3
9-13/32”
5-29/32”
4-41/64”
Direct mount Pipe mount
*Model dependent
79EATON signalling and alarms product overview
Expertline LED
Hazardous location LED strobe
Certification cULus
Area classification Hazardous locations, ordinary locations
UL/NEC classification Class I, Div. 2, Groups A, B, C, D, T4
Class I, Zone 2, Groups IIA, IIB, IIC, T4
Certified temperature -40°F to +140°F
Ingress protection NEMA 4X
Material Polycarbonate
Entries 1x ½” NPT, 2x blind plug ½” NPT
Weight 5.5lb
Voltage 24Vdc, 120-230Vac
Light source LED
Options LED colour
7-1/4
2-3/8
4-11/16
11-3/4
12-3/8
SM87HXB
5 joule hazardous location strobe
Certification cULus, CSA
Area classification Hazardous locations, ordinary locations
UL/NEC classification Class I, Div, 1, Groups C, D
Class I, Zone 1, Aex d IIB, Exd IIB
Approvals SIL2
Certified temperature -67°F to +158°F
Ingress protection NEMA 4X & 6
Material Stainless steel or alloy
Entries Up to 4 x ½” NPT or ¾” NPT
Weight Alloy: 4.4lb. Stainless steel: 8.4lb
Voltage 24-48Vdc, 110-254Vac
Light source Xenon
Options Lens colour, lens guard, lens guard, tag/duty label,
body colour
XB11
5 joule hazardous location strobe
Certification cULus
Area classification Hazardous locations, ordinary locations
UL/NEC classification Class I, Div. 2, Groups C, D
Class I, Zone 1, AEx d IIB, Ex d IIB
Approvals CSFM
Certified temperature -67°F to +158°F
Ingress protection NEMA 4X & 6
Material Corrosion free GRP
Entries 2 x ½” NPT
Weight 5.5lb
Voltage 24-48Vdc, 110-240Vac
Light source Xenon
Options Flash rate, lens colour, lens guard, mounting,
tag/duty label, body colour
Hazardous area US products
7-1/8”
4-3/4”
8-3-32”
7-7/8”
*Model dependent
80 EATON signalling and alarms product overview
XB15
5, 10 & 15 joule hazardous location xenon strobes
Certification cULus, ULC
Area classification Hazardous locations, ordinary locations
UL/NEC classification Class I, Div. 2, Groups A*, B*, C, D
Class II, Div. 2, Groups F, G
Class I, Zone 1 AEx d IIC* & IIB, Ex d IIB
Approvals SIL1, CSFM, UL Marine
Certified temperature -67°F to +158°F
Ingress protection NEMA 4X & 6
Material Corrosion free GRP
Entries Up to 3* x ½" NPT or ¾" NPT
Weight 5.7lb - 6.6lb
Voltage 24-48Vdc, 110-254Vac
Light source Xenon
Options Tube energy, flash rate, lens colour, lens guard,
mounting, tag & duty label, relay initiate, body
colour
XB4
21 joule hazardous location xenon strobe
Certification cULus
Area classification Hazardous locations, ordinary locations
UL/NEC classification Class I, Div. 1, Groups C, D
Class I, Zone 1, Groups IIB & IIA
Certified temperature -67°F to +158°F
Ingress protection NEMA 4X & 6
Material Stainless steel or alloy
Entries Up to 3 x ½” NPT or ¾” NPT
Weight Alloy: 14.5lb - 16.7lb
Stainless steel: 33.0lb - 35.0lb
Voltage 24Vdc, 110-240Vac
Light source Xenon
Options Flash rate, relay initiate, lens guard, lens colour,
tag/duty label, body colour
XB12
21 joule hazardous location xenon strobe
Certification cULus
Area classification Hazardous locations, ordinary locations
UL/NEC classification Class I, Div. 2, Groups C, D
Class I, Zone 1, AEx d IIB, Ex d IIB
Approvals CSFM, UL Marine
Certified temperature -67°F to +158°F
Ingress protection NEMA 4X & 6
Material Corrosion free GRP
Entries 2 x ½” NPT
Weight 15.4lb
Voltage 24Vdc, 110-240Vac
Light source Xenon
Options Body & lens colour, lens guard, tag & duty labels,
flash rate, mounting method
Hazardous area US products
11”
9-1/16”
12-3/32”
11-1/32”
9-13/32”
150
3
9-13/32”
5-29/32”
4-41/64”
Direct mount Pipe mount
*Model dependent
81EATON signalling and alarms product overview
XB16
10 joule hazardous location xenon strobe
Certification cULus
Area classification Hazardous locations, ordinary locations
UL/NEC classification Class I, Div. 2, Groups A ,B, C, D
Class II, Div. 2, Groups F, G
Approvals UL1971, CSFM
Certified temperature -67°F to +158°F
Ingress protection NEMA 4X & 6
Material Corrosion free GRP
Entries 1 x ¾” NPT
Weight 2.2lb
Voltage 24-48Vdc, 110-254Vac
Light source Xenon
Options Flash rate, lens colour, lens guard, tag & duty
label, relay initiate, body colour
SM87LU1/LU3
Hazardous location steady burning light
Certification cULus, CSA
Area classification Hazardous locations, ordinary locations
UL/NEC classification Class I, Div. 1, Groups C, D
Class I, Zone 1, Aex d IIB, Exd IIB
Certified temperature -67°F to +131°F
Operating temperature SM87LU1: -4°F to +131°F
SM87LU3: -67°F to +131°F
Ingress protection NEMA 4X & 6
Material Stainless steel or alloy
Entries SM87LU1: Up to 3 x ½” NPT or ¾” NPT
SM87LU3: Up to 4 x ½” NPT or ¾” NPT
Weight Alloy: 5.5lb. Stainless steel: 8.3lb
Voltage 24-48Vdc, 110-254Vac
Light source Filament, fluorescent
Options Lens colour, lens guard, tag/duty labels, body
colour
Hazardous area US products
FL4 & FB4
Ex d(e) steady beacons
Certification cULus
Area classification Hazardous locations, ordinary locations
UL/NEC classification Class I, Div. 1, Groups C, D
Class I, Zone 1, Groups IIB & IIA
Certified temperature FL4: -4°F to +131°F
FB4: -67°F to +131°F
Operating temperature FL4: -4°F to +131°F
FB4: -67°F to +131°F
Ingress protection NEMA 4X & 6
Material Stainless steel or alloy
Entries Up to 3 x ½” NPT or ¾” NPT
Weight Alloy: 14.3lb - 19.6lb
Stainless steel: 32.8lb - 38.1lb
Voltage 24-110Vdc, 110-254Vac
Light source Filament, fluorescent
Options Lamp wattage, lens colour, lens guard, tag & duty
labels, relay initiate, body colour
4-5/8”
8-35/64”
7-1/8”
4-3/4”
11”
9-1/16”
82 EATON signalling and alarms product overview
FB11 & FB12
Hazardous location steady burning lights
Certification cULus
Area classification Hazardous locations, ordinary locations
UL/NEC classification Class I, Div. 2, Groups C, D
Class I, Zone 1, AEx d IIB, Ex d IIB
Certified temperature -67°F to +131°F
Ingress protection NEMA 4X and 6
Material Corrosion free GRP
Entries 2 x ½” NPT
Weight FB11: 6.2lb. FB12: 16.7lb
Voltage 24-48Vdc, 110-254Vac
Light source Filament
Options Lamp wattage, lens colour, lens guard, mounting,
tag/duty label, body colour
FB15
Hazardous location steady burning light
Certification cULus
Area classification Hazardous locations, ordinary locations
UL/NEC classification Class I, Div. 2, Groups A*, B*, C, D
Class I, Zone 1 AEx d IIC* & IIB, Ex d IIB
Approvals CSFM
Certified temperature -67°F to +158°F
Ingress protection NEMA 4X and 6
Material Corrosion free GRP
Entries Up to 3* x ½” NPT or ¾” NPT
Weight Pipe: 5.7lb. Direct: 6.6lb
Voltage 24-48Vdc, 110-254Vac
Light source Filament
Options Lamp wattage, lens colour, lens guard, mounting,
tag & duty label, lens colour
DB1P
Hazardous location horn
Certification cULus
UL/NEC classification Class I, Div 1, Groups C & D
Approvals SIL1
Certified temperature -13°F to +158°F
Ingress protection NEMA 4X
Material Alloy
Entries Up to 3 x ½” NPT or ¾” NPT
Weight 7.7lb - 12.3lb*
Voltage 12-48Vdc, 110Vac
Sound output Max: 100dB, 10’ (±3dB)*
Tones 27
Stages 2*
Options Output level, entries, tag & duty labels, relay
initiate, remote tone select, EOL resistor, colour
Hazardous area US products
Direct mount Pipe mount
6-19/32”
6-11/16”
12-3/32”
11-1/32”
7-1/8”
4-3/4”
9-13/32”
150
3
9-13/32”
5-29/32”
4-41/64”
*Model dependent
83EATON signalling and alarms product overview
DB3B
Hazardous location horn
Certification cULus
UL/NEC classification Class I, Div. 2, Groups A, B, C, D
Class II, Div. 2, Groups F, G
Approvals SIL2, CSFM
Operating temperature -67°F to +158°F
Ingress protection NEMA 4X & 6
Material Body: corrosion free GRP
Flare: thermoplastic
Entries Up to 2 x ½” NPT or M20
Weight 10lb (based on long flare unit)
Voltage 12-48Vdc, 110-254Vac
Sound output Max: 112dB, 10’ (±3dB)*
Tones 28
Stages 3 (5 voltage free)
Options Tag & duty labels, swivel bracket, EOL resistor,
Earth continuity, tone activation method, voltage
free activation, flare type, custom tones, flare
colour
DB5
Hazardous location horn
Certification FM, CSA
UL/NEC classification Class I, Div, 1, Groups A, B, C, D
Operating temperature -4°F to +131°F
Ingress protection NEMA 4
Material ABS
Entries Up to 2 x M20 via knockouts
Weight 0.7lb
Voltage 12-24Vdc
Sound output Max: 90dB, 10’ (±3dB)
Tones 26
Options Tag label, body colour
Hazardous area US products
7-7/8”
11-7/64”
Ø3-21/32 ±1/8
2-1/8 ±1/8
1-57/64±1/8
*Model dependent
dGW21/dRGW21
Hazardous location bell
Certification cULus
UL/NEC classification Class I, Div. 2, Groups A, B, C, D
Operating temperature -4°F to +104°F
Ingress protection NEMA 4X
Material Corrosion free GRP
Entries 2 x ½” NPT
Weight 12lb
Voltage 24Vdc, 120Vac
Sound output Max: 105dB, 10’ (±3dB)
8-1/8
10-5/8
4-5/16
Ø7-7/8
84 EATON signalling and alarms product overview
DB4B
Hazardous location loudspeaker
Certification cULus
UL/NEC classification Class I, Div. 2, Groups A, B, C, D
Class II, Div. 2, Groups F, G
Approvals SIL2, CSFM
Operating temperature -67°F to +158°F*
Ingress protection NEMA 4X & 6
Material Body: corrosion free GRP. Flare: thermoplastic
Entries Up to 2 x ½” NPT or M20
Weight 11.0lb (based on long flare unit)
Sound output Sensitivity (1W, 10’): 100dB* (±3dB)
Max at full power (25W, 10’): 114dB* (±3dB)
Transformer 100V, 70V, 25V
Wattage & transformer
tappings
25W: 25.0, 12.5, 6.0, 4.0, 2.0, 1.0*
15W: 15.0, 7.5, 5.0, 4.0, 2.0, 0.8*
8W: 8.0, 4.0, 2.0, 1.5, 0.7, 0.4*
Low impedance 8Ω*
Options Tag & duty labels, swivel bracket, DC blocking
capacitor, flare length, flare colour
DB16
Hazardous location loudspeaker
Certification cULus
UL/NEC classification Class I, Div. 2, Groups A, B, C, D*
Certified temperature -67°F to +104°F
Ingress protection NEMA 4X & 6
Material Corrosion free GRP
Entries Up to 2 x ½” NPT or ¾” NPT
Weight 12.0lb
Sound output Sensitivity (1W, 10’): 100dB* (±3dB)
Max at full power (30W, 10’): 112dB* (±3dB)
Transformer 100V
Wattage & transformer
tappings
25W: 25.0 ,12.5, 6.0, 4.0, 2.0, 1.0*
30W: 30.0, 25.0, 12.0, 6.0, 4.0, 2.0*
Low impedance 8Ω*
Options Tag & duty labels, Earth continuity, Earth stud,
colour
Hazardous area US products
10-5/16”
13-61/64”
dGH 21
Hazardous location hooter
Certification cULus
UL/NEC classification Class I, Div. 2, Groups A, B, C, D
Certified temperature -4°F to +104°F
Ingress protection NEMA 4X
Material Corrosion free GRP
Entries 2 x ½” NPT
Weight 12lb
Voltage 24Vdc, 240Vac
Sound output Max: 105dB, 10’ (±3dB)
8 9/16“
10 3/4“
7-7/8”
11-7/64”
*Model dependent
85EATON signalling and alarms product overview
DB3B/XB11
Hazardous location horn / 5 joule strobe combination unit
Certification cULus
Area classification Hazardous locations, ordinary locations
UL/NEC classification Class I, Div. 2, Groups C, D
Certified temperature -67°F to +158°F
Ingress protection NEMA 4X & 6
Material Body: corrosion free GRP. Flare: thermoplastic
Entries 1 x ½” NPT customer entry
Note: customer entry is in the strobe
Voltage 24-48Vdc, 110-240Vac
Sound output Max: 112dB*, 10’ (±3dB)
Tones 28
Stages 3
Light source Xenon
Options Body, lens & flare colour, lens guard, flash rate,
earth continuity, tel. initiate, flare type, labels
DB3B/SM87HXB
Hazardous location horn / 5 joule strobe combination unit
Certification cULus
Area classification Hazardous locations, ordinary locations
UL/NEC classification Class I, Div. 1, Groups C, D
Approvals SIL1
Certified temperature -67°F to +158°F
Ingress protection NEMA 4X & 6
Material Strobe: stainless steel or alloy
Sounder body: corrosion free GRP
Flare: thermoplastic
Entries Up to 3 x ½” NPT customer entries
Note: Customer entries are in the strobe
Voltage 24-48Vdc, 110-254Vac
Sound output Max: 112dB*, 10’ (±3dB)
Tones 28
Stages 3
Light source Xenon
Options Body, lens & flare colour, lens guard, flash rate,
earth continuity, tel. initiate, flare type, labels
Hazardous area US products
16 1/2”
8 2/3”
16 1/2”
8 2/3”
DB3B/XB15
Hazardous location horn / 5, 10 & 15 joule strobe combination units
Certification cULus
Area classification Hazardous locations, ordinary locations
UL/NEC classification Class I, Div. 2, Groups A, B, C, D
Class II, Div. 2, Groups F, G
Approvals SIL1
Certified temperature -67°F to +158°F
Ingress protection NEMA 4X & 6
Material Body: corrosion free GRP. Flare: thermoplastic
Entries Up to 2 x ½” NPT or ¾” NPT customer entries
Note: customer entries are in the strobe
Voltage 24-48Vdc, 110-254Vac
Sound output Max: 112dB*, 10’ (±3dB)
Tones 28
Stages 3
Light source Xenon
Options Tube energy, body, lens & flare colour, lens guard,
flash rate, earth continuity, relay & tel. initiate,
flare type, labels
8-11/16”
16-9/16”
*Model dependent
86 EATON signalling and alarms product overview
SM87SL
5 joule hazardous location xenon and LED status light
Certification cULus*, CSA*
Area classification Hazardous locations, ordinary locations
UL/NEC classification Class I, Div. 1, Groups C, D
Class I, Zone 1, Aex d IIB, Exd IIB
Certified temperature Class I, Div 1: -13°F to +131°F
Class I, Zone 1: -67°F to +131°F
Ingress protection NEMA 4X and 6
Material Alloy
Entries Up to 3 x ½” NPT or ¾” NPT
Weight See datasheet
Voltage 24-48Vdc, 110-254Vac
Light source Xenon, filament, fluorescent
No. of ways Up to 5
Options Lens colour, lens guard, lens guard, tag/duty label,
body colour
XB11SL
5 joule hazardous location status light
Certification cULus
Area classification Hazardous locations, ordinary locations
UL/NEC classification Class I, Div. 2, Groups C, D
Class I, Zone 1, AEx d IIB, Ex d IIB
Certified temperature -67°F to +158°F*
Ingress protection NEMA 4X and 6
Material Corrosion free GRP
Entries 1 x ½” NPT
Weight See datasheet
Voltage 24-48Vdc, 110-240Vac
Light source Xenon, filament, fluorescent
No. of ways Up to 5
Options Body & lens colour, tag & duty labels
Hazardous area US products
6-11/16”
19-11/16”
11-1/16”
19-3/4”
11-1/2”
DB1/SM87HXB
Hazardous location horn / 5 joule strobe combination unit
Certification cULus
Area classification Hazardous locations, ordinary locations
UL/NEC classification Class I, Div, 1, Groups C, D
Approvals SIL1
Certified temperature -13°F to +158°F
Ingress protection NEMA 4X
Material Stainless steel or alloy
Entries Up to 3 x ½” NPT customer entries
Note: Customer entries are in the strobe
Voltage 24-48Vdc, 110-240Vac
Sound output Max: 100dB*, 10’ (±3dB)
Tones 27
Stages 2
Light source Xenon
Options Body & lens colour, lens guard, flash rate, earth
continuity, tel initiate, labels
8”
13 3/4”
*Model dependent
87EATON signalling and alarms product overview
XB12SL
21 joule xenon strobe and steady burning hazardous location status light
Certification cULus
Area classification Hazardous locations, ordinary locations
UL/NEC classification Class I, Div. 2, Groups C, D
Class I, Zone 1, AEx d IIB, Ex d IIB
Approvals CSFM
Certified temperature -67°F to +158°F
Ingress protection NEMA 4x & 6
Material Corrosion free GRP
Entries 1 x ½" NPT
Weight See datasheet
Voltage 24Vdc, 110-240Vac
Light source Xenon, filament, fluorescent, rotating tungsten
halogen
No. of ways Up to 5
Options Flash rate, lamp wattage, lens colour, lens guard,
tag/duty label, body colour
ExResistTel
Hazardous and ordinary location robust telephone
Certification UL
UL/NEC classification Class 1, Div 2, Groups A, B, C, D T5
Certified temperature -4°F to +104°F
Ingress protection NEMA 4X
Material Corrosion-free GRP
Weight 13lbs
Options Loudspeaker set, TWIN sounder/beacon,
protection hood, secondary sounder
Hazardous area US products
~261
10-1/4“
~133
8-15/16“
Ex ResistTel UL (small)
11-1/16”
19-3/4”
11-1/2”
SL15
5, 10 and 15 joule hazardous location xenon and LED status light
Certification cULus
Area classification Hazardous locations, ordinary locations
UL/NEC classification Class I, Div. 2, Groups A*, B*, C, D
†Class II, Div. 2, Groups F, G
Class I, Zone 1, AEx d IIC* & IIB, Ex d IIB
Approvals UL Marine
Certified temperature -67°F to +158°F
Ingress protection IP66 & IP67, NEMA 4X & 6
Material Corrosion free GRP
Entries Up to 2 x ½” NPT or ¾” NPT
Weight See datasheet
Voltage 24-48Vdc, 110-254Vac*
Light source Xenon, filament, LED
No. of ways Up to 4
Options Flash rate (xenon & LED), light source, tube energy
(xenon), lens guard, tag & duty label, body colour
† Not filament
8 3/16”
7 3/4”
9 13/16”
7 3/4”
*Model dependent
88 EATON signalling and alarms product overview
Analogue InduTel Wall telephone
Ordinary location telephone with protection door
Certification UL
UL/NEC classification IT equimpment safety
Certified temperature -40°F to +141°F
Ingress protection NEMA 3R
Material Polycarbonate
Weight 5lbs approx
Options Keypad, transparent door, optical call indicator
Options Body colour
HD1
Hazardous location heat detector
Certification cULus
Area classification Hazardous locations, ordinary locations
UL/NEC classification Class I, Div. 2, Groups A, B, C, D
Class I, Zone 2, Group IIC
Approvals SIL2, ABS
Certified temperature -4ºF to +131ºF
Ingress protection NEMA 4X & 6
Material Corrosion free GRP
Entries 2 x ½” NPT (via supplied adaptors)
Weight 2.4lb
Options Temperature setting ,tag & duty label, probe
guard, monitoring resistors and diode, body colour
4-21/64”
5-1/8” 6-1/2”
Hazardous area US products
18”
8-1/4“
FernTel IP Zone 2
Hazardous and ordinary location wall and desk IP telephone
Certification UL
ATEX/IEC classification Class 1, Division 2, Groups A, B, C, D T5
Certified temperature -4°F to +140°C
Ingress protection NEMA 4X
Material Polycarbonate
Weight 5.3lbs
Options Body colour,spiral cord/armoured cord, stabiliser
bracket
89EATON signalling and alarms product overview
GHG 74/44
Hazardous location control units and terminal boxes
Certification cCSAus
Area classification Hazardous locations, ordinary locations
UL/NEC classification Class I, Div. 2, groups A, B, C, D
Class II, Div. 1, Groups E, F, G
Class II, Div. 2, Groups F, G
Class I, Zone 1, AEx e II, Ex e II
Certified temperature Normal: -4°F to +104°F
Optional: -67°F to +131°F
Ingress protection IP66
Material Corrosion free GRP or stainless steel
Entries Multiple entries per face*
Weight See datasheet*
Options Terminals, enclosure size
Hazardous area US products
JB10 & JB11
Hazardous location junction boxes
Certification cULus
Area classification Hazardous locations, ordinary locations
UL/NEC classification Class I, Div. 2, Groups A, B, C, D
Class I, Zone 1, AEx e IIC, Ex e IIC
Certified temperature -4°F to +131°F
Ingress protection NEMA 4X & 6
Material Corrosion free GRP
Entries Up to 2 x ½” NPT or ¾” NPT per face
Weight JB10: 2.4lb. JB11: 4.0lb
Options Terminals, earth continuity, tag label, body colour
5-1/8”
4-24/64”
*Model dependent
GHG 411 81
Hazardous location control station
Certification cULus
Area classification Hazardous locations, ordinary locations
UL/NEC classification Class I, Div. 2, Groups A, B, C, D
Class II, Div. 1, Groups E, F, G (Canada)
Class II, Div. 2, Groups F, G
Class I, Zone 1, AE x e IIC T6, Ex e II T6
Certified temperature Normal: -4°F to +104°F
Optional: -67°F to +131°F
Ingress protection IP66
Material Polyamide
Entries 1 x ½” NPT
Weight 1.0lb*
Options Pushbuttons, emergency stop, rotary switches
block, potentiometer, lamps, 3 position key switch,
gold contact block
3-11/32”
4-1/2”
5-29/32”
5-29/32”
JB10
JB11
90 EATON signalling and alarms product overview
Hazardous area US products
GHG 411 82
Hazardous location control station
Certification cULus
Area classification Hazardous locations, ordinary locations
UL/NEC classification Class I, Div. 2, Groups A, B, C, D
Class II, Div. 1, Groups E, F, G (Canada)
Class II, Div. 2, Groups F, G
Class I, Zone 1, AE x e IIC T6, Ex e II T6
Certified temperature Normal: -4°F to +104°F
Optional: -67°F to +131°F
Ingress protection IP66
Material Polyamide
Entries 1 x ½” NPT
Weight 1.0lb*
Options Pushbuttons, emergency stop, rotary switches
block, potentiometer, lamps, 3 position key switch,
gold contact block
3-11/32”
6-9/64”
GHG 411 83
Hazardous location control station
Certification cULus
Area classification Hazardous locations, ordinary locations
UL/NEC classification Class I, Div. 2, Groups A, B, C, D
Class II, Div. 1, Groups E, F, G (Canada)
Class II, Div. 2, Groups F, G
Class I, Zone 1, AE x e IIC T6, Ex e II T6
Certified temperature Normal: -4°F to +104°F
Optional: -67°F to +131°F
Ingress protection IP66
Material Polyamide
Entries 1 x ½” NPT
Weight 1.0lb*
Options Pushbuttons, emergency stop, rotary switches
block, potentiometer, lamps, 3 position key switch,
gold contact block
3-11/32”
6-1/2”
*Model dependent
91EATON signalling and alarms product overview
Eaton
1000 Eaton Boulevard
Cleveland, OH 44122
United States
Eaton.com
© 2015 Eaton Corporation
All Rights Reserved
Printed in UK
Ref: OVERV0816
August 2016
Eaton’s Crouse-Hinds Business
Eaton’s Crouse-Hinds Business
1201 Wolf Street
Syracuse, NY 13208
(866) 764-5454
crouse.customerctr@cooperindustries.com
Eaton is a registered trademark.
All other trademarks are property
of their respective owners.
Eaton
The safety you rely on.
See the complete offering at http://www.medc.com
and www.fhf.de MEDC FHF
Italy Office
Via Al Ponte Polcevera 8/14
16161 Genova
Italia
T: +39 10 7416 801
F: +39 10 740 21 31
Norway Office
P.O. Box 791 Stoa
NO-4809 Arendal
Norway
T: +47 37 06 37 00
F: +47 37 06 37 06
USA Office
3413 North Sam
Houston
Parkway West
Houston, TX 77086
USA
T: +1 713 937 9772
F: +1 713 937 9773
Dubai Office
Techno Park, Jebel Ali (South)
P.O. Box 261768
Dubai,
United Arab Emirates
T: +971 4 8066100
Korea Office
7th Fl. Parkland Building
601, Eonju-ro, Gangnam-gu
Seoul
Korea
T: +82 2 6380 483
F: +82 2 3484 6778
Singapore Office
No.2 Serangoon
North Avenue 5
#06-01. Fu Yu Building
Singapore 554911
T: +65 6645 9888
Germany Office
FHF Funke + Huster Fernsig GmbH
Gewerbeallee 15-19
45478 Mülheim
a.d.Ruhr, Germany
T: +49 208 82 68 0
F: +49 208 82 68 286
Saudi Arabia Office
Middle East LLC - Dammam
K.S.A.
PLANT AT 2ND
Industrial City Dammam
111, Jubail Street
PO BOX: 70160
Al Khobar, Pin:31952.
Kingdom of Saudi Arabia
T: +966 3 812 2970
Hazardous Area Communications
Unit B
Sutton Parkway
Oddicroft Lane
Sutton in Ashfield
NG17 5FB
United Kingdom
Tel: + 44 1623 444400
Fax: + 44 1623 444531
hacmarketing@eaton.com
www.crouse-hinds.com/hac