Signalling and alarms Product overview CROUSE-HINDS Eaton brings you the comprehensive MEDC and FHF signalling, alarm and notification range for hazardous and harsh environments SERIES Part of our wider solution for harsh and hazardous environments PA / GA Signalling and alarms Designed, engineered and manufactured according to individual project specifications and industry regulations. The SonixTM system uses the latest in digital technology and can be integrated with a wide range of Eaton products to ensure the integrity of your assets in even the most demanding of environments. Our MEDC and FHF product lines offer a wide range of products specifically designed for harsh environments where there is a risk of explosion for both onshore and offshore applications. This range of products including manual activation, visual and audible alarms, and loudspeakers, can be connected to IMCOS or SonixTM delivering the best combination of performance and safety. CCTV Cutting edge technology from our market leading brands of HernisTM and Oxalis. With the widest range of camera stations and system solutions from a single manufacturer, we have the products and experience to meet today's demanding surveillance and security needs. With products available that are explosion protected or weatherproof, analogue or IP, fixed, dome or PTZ, our experience and proven reliability can meet your specification requirements. 2 IMCOS One of only a few systems in the world to have seven different type approvals. IMCOS provides the solutions you need both Onshore and Offshore. The following applications demonstrate the ability to provide a single solution. With IMCOS and our latest developments in technology, we are able to provide a single network which provides reduced cable architecture. Our LAN systems are able to share a highway of information and resources, interlinking video, voice and data with our VoIP telephones, IPTV streaming, CCTV, PA/GA and Intercom systems through one fibre or copper backbone. EATON signalling and alarms product overview Mining control and communications Our FHF-BT business has over 100 years of experience in mining applications. Today the team delivers intrinsically safe turnkey automation and communications solutions on a global basis. Our solutions based offering includes shaft signalling and communications, loudspeaker and conveyer belt control, data transmission, radio systems and various automation systems. Telecommunications Whether a traditional analogue, digital, VoIP or Hybrid telephone system is what you require, we can provide the solution you need with our IMCOS PABX system. Together with a wide range of telephones we can provide standard, weatherproof, explosion protected and IP phones. Proven solutions for harsh and hazardous environments Eaton has brought together the most recognised names in oil and gas, such as MEDC and FHF, to be able to provide you with a comprehensive product offering of specialist, high quality equipment designed to make harsh and hazardous locations a safer, more efficient working environment. Eaton offer a specialised team of highly qualified staff to ensure all aspects of engineering, design and configuration within your project are fulfilled - from initial stages of concept through to commissioning. The MEDC signalling and alarm range has been relied upon by the oil & gas industry to deliver high quality, innovative products for many years. With an extensive range of worldwide certifications including ATEX and IECEx, Eaton has the capability to deliver industry leading solutions designed to meet customer and project specifications. Additionally, Eaton can provide a world class range of FHF telephone equipment designed for harsh and hazardous environments. Decades of experience in the fields of industrial communication and signalling, together with our specialist expertise, ensure that customers are provided with the most reliable and up to date technology available. How to use this overview This overview contains concise information on Eaton's range of MEDC and FHF signalling and alarm products for use in potentially explosive atmospheres, harsh industrial and marine environments. To use this guide, refer to the product group of interest, read through the brief information and select the specific product for your application. For more detailed information and ordering codes visit our website www.crouse-hinds.com/hac where a detailed datasheet can be downloaded. Or alternatively contact one of our sales offices for a full catalogue, all details can be found on the back page. Contents Hazardous area guide. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 Hazardous area manual alarm call points. . . . . . . . . . . . . 6 Hazardous area beacons. . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 Industrial beacons. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20 Hazardous area sounders. . . . . . . . . . . . . . . . . . . . . . . . . . . 26 Industrial sounders . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32 Hazardous area loudspeakers. . . . . . . . . . . . . . . . . . . . . . . 40 Industrial loudspeakers. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 44 Hazardous area status lights and combination units. . . . 48 To see the complete Hazardous Area Communication range, please visit www.crouse-hinds.com/hac Industrial status lights and combination units . . . . . . . . . 54 Hazardous area telephones and accessories . . . . . . . . . . 58 Industrial telephones and accessories. . . . . . . . . . . . . . . . 64 Hazardous area control and distribution. . . . . . . . . . . . . . 70 Hazardous area US products. . . . . . . . . . . . . . . . . . . . . . . . 76 EATON signalling and alarms product overview 3 Hazardous area guide This information is intended as a guide only and further expert guidance should be sought before placing into service, maintaining or repairing any item of equipment in a potentially explosive atmosphere. Definition Potentially explosive atmospheres exist where there is a risk of explosion due to mixtures of gas/air, vapour/air, dust/air or other flammable combinations. Where electrical equipment has to be used in these areas, it must be so designed and constructed such that it does not create sources of ignition capable of igniting these mixtures. Area classification Process plants are divided into Zones (European and IEC method) or Divisions (North American method) according to the likelihood of a potentially explosive atmosphere being present. Note: North American legislation now allows Zones to be used to classify areas, where this practice is used it follows the IEC Zone method. European & IEC Classification Definition of zone or division North American Classification Zone 0 (gases) Zone 20 (dusts) Zone 1 (gases) Zone 21 (dusts) Zone 2 (gases) Zone 22 (dusts) An area in which an explosive mixture is continuously present or present for long periods Class I Division 1 (gases) Class II Division 1 (dusts) Class I Division 1 (gases) Class II Division 1 (dusts) Class I Division 2 (gases) Class II Division 2 (dusts) Class III Division 1 (fibres) Class III Division 2 (fibres) An area in which an explosive mixture is likely to occur in normal operation An area in which an explosive mixture is not likely to occur in normal operation and if it occurs it will exist only for a short time Gas groups, dusts and fibres Temperature There are two main gas groups and one dust group, Group I - Mining only and Group II - Surface Industries. To guard against hot surfaces igniting gases, all electrical equipment intended for use in Potentially Explosive Atmospheres is classified according to the maximum surface temperature it will reach in service (normally based on a surrounding ambient temperature of 40C (102F). These categories are used in European and IEC. groupings. Group I is concerned only with underground mining where methane and coal dust are present. Group II gases occurring in surface industries, are sub-grouped according to their volatility. This enables electrical equipment to be designed to less onerous tolerances if it is to be used with the least volatile gases. Temperature Classification European/I.E.C. North American Maximum Surface Temperature T1 T2 T1 T2 T2A T2B T2C T2D T3 T3A T3B T3C T4 T4A T5 T6 450 C 300 C 280 C 260 C 230 C 215 C 200 C 180 C 165 C 160 C 135 C 120 C 100 C 85 C Group III explosive dusts occurring in surface industries and are sub grouped according to their volatility. Typical gas/material European/I.E.C. Gas Group North American Gas Group Methane Acetylene Hydrogen Ethylene Propane Metal dust Coal dust Grain dust I IIC IIC IIB IIA - A B C D E F G T3 T4 T5 T6 The equipment coding will be as the current practice plus an additional code as follows: ATEX Ex II 2 GD i.e. After 1st July 2003, the ATEX directive came into force and is a mandatory requirement for all equipment intended for use in Potentially Explosive Atmospheres within the E.U. All relevant MEDC equipment is covered by the date it comes into force and many are already certified. It should be noted also that MECHANICAL equipment is covered by the ATEX directive so for the first time items such as gearboxes will have to carry ATEX certification. Ex - Explosionproof in accordance with ATEX. II - Group II surface industries 2 - Category 2 equipment (suitable for use in Zone 1) note: Category 1 is suitable for Zone 0. Category 3 is suitable for Zone 2. G - suitable for atmospheres containing gas D - suitable for atmospheres containing dust Equipment will be CE marked when certified to ATEX. General Recommendations Classification of Hazardous Areas Inspection and Maintenance of Electrical Equipment Requirements for Flameproof Enclosures Requirements for Intrinsically Safe Equipment Requirements for Increased Safety Equipment Requirements for Purged and Pressurised Equipment Requirements for Non-Sparking Equipment 4 International Europe U.S.A. IEC60079-14 IEC60079-10 IEC60079-17 IEC60079-14 IEC60079-14 IEC60079-14 IEC60079-14 IEC60079-14 EN60079-14 EN60079-10 EN60079-17 EN60079-14 EN60079-14 EN60079-14 EN60079-14 EN60079-14 N.E.C. Chapter 5 N.E.C. Chapter 5 N.E.C. Chapter 5 N.E.C. Chapter 5 N.E.C. Chapter 5 N.E.C. Chapter 5 EATON signalling and alarms product overview - Selection, installation and maintenance of electrical equipment intended for use in potentially explosive atmospheres International and national standards are published giving details of requirements for the safe use of electrical equipment in potentially explosive atmospheres as follows: Types of electrical equipment suitable for use in potentially explosive gas, vapour and mist atmospheres Different techniques are used to prevent electrical equipment from igniting explosive atmospheres. There are restrictions on where these different types of equipment can be used as follows: Flameproof Enclosure - An enclosure used to house electrical equipment, which when subjected to an internal explosion will not ignite a surrounding explosive atmosphere. Intrinsic Safety - A technique whereby electrical energy is limited such that any sparks or heat generated by electrical equipment is sufficiently low as to not ignite an explosive atmosphere. Increased Safety - This equipment is so designed as to eliminate sparks and hot surfaces capable of igniting an explosive atmosphere. Typical EPL Area of use Designation Standard Zones Ex da Ex db Ex dc IEC/EN 60079-1 0 1 2 Zones Ex ia 0 Ex ib 1 Ex ic 2 IEC/EN 60079-11 Ex e IEC/EN 60079-7 USA Area of use Designation Standard Class I Divisions 1 & 2 - - - UL1203 Class I Divisions 1 & 2 - - - UL913 Zones 1 - Purged and Pressurised - Electrical equipment is housed in an enclosure which is initially purged to remove any Ex pxb explosive mixture, then pressurised to prevent ingress of the surrounding atmosphere prior to energisation. Ex pyb Ex pzc IEC/EN 60079-2 Encapsulation - A method of exclusion of the explosive atmosphere by fully encapsulating the electrical Ex ma components in an approved material. Ex mb Ex mc IEC/EN 60079-18 Oil Immersion - The electrical components are immersed in oil, thus excluding the explosive atmosphere from any sparks or hot surfaces. Ex o IEC/EN 60079-6 Powder Filling - Equipment is surrounded with a fine powder, such as quartz, which does not allow the Ex q surrounding atmosphere to come into contact with any sparks or hot surfaces. IEC/EN 60079-5 Zones Class I Non-sparking - Sparking contacts are sealed against ingress of the surrounding atmosphere, hot surfaces are eliminated. Zones Optical Radiation - Protection of equipment and transmission systems using optical radiation Equipment for combustible dust 1 1 2 Zones 0 1 2 - - - Zones Class I Divisions 1 & 2 1 - Zones - - - - - - 1 2 Ex n IEC/EN 60079-15 Zones 1 Op pr 1 Op sh 2 Op is IEC/EN 60079-28 Typical EPL Area of use Designation Standard Enclosure - Equipment dust ignition protection by enclosure Zones Ex ta 20 Ex tb 21 Ex tc 22 IEC/EN 60079-31 Intrinsic Safety Zones 20 Ex ia 21 Ex ib 22 Ex ic IEC/EN 60079-11 Encapsulation Pressurised Div 1 Div 1 Div 2 NFPA496 Div 1 Div 1 Div 2 USA Area of use Designation Standard Class II Division 1 & 2 UL1263 Class II Division 1 & 2 UL913 Zones 20 Ex ma 21 Ex mb 22 Ex mc IEC/EN 66079-18 Ex Pxb Ex Pyb Ex Pzc IEC/EN 60079-2 Zones 21 21 22 Class II (PX) Div 1 (PY) Div 1 (PZ) Div 2 Eaton advise that all Explosion-proof electrical equipment is maintained, by suitably trained personnel, in accordance with the Manufacturers' recommendations. Any spare parts used should be purchased from the original Manufacturer and repairs should be carried out by the Manufacturer or under their supervision, in order that the item remains in conformance with the certification documents. EATON signalling and alarms product overview 5 Hazardous area manual alarm call points SM87PB SM87BG Page 7 BG PH1 Page 7 BG2 Page 8 PB Page 7 BG3 Page 8 Page 8 Ex-Fire Alarm Switch Page 9 Page 9 Eaton provide a range of manual alarm call points specifically designed for the purpose of raising an alarm in the case of an emergency in a hazardous area. The call points can be made from a selection of materials depending on project specification. This includes glass reinforced polyester (GRP), a light weight and corrosion free material, allowing easy installation and low maintenance cost. Stainless steel is also available which is a heavy duty, long wearing material with an increased life span. All of Eaton's call points have a minimum IP rating of IP66, with the majority also including IP67, and can be certified to one of our worldwide accreditations, including ATEX and IECEx. There are also options for the inclusion of LED status indicators and addressable location (or address) within the unit and many can be painted a variety of colours to the customer's specification. 6 EATON signalling and alarms product overview Hazardous area manual alarm call points SM87PB Ex d & Ex ia Push button call points Certification Area classification ATEX/IEC classification UL/NEC classification Approvals Certified temperature Ingress protection Material Entries Weight Switches Options ATEX, IECEx, cULus, ULC, CSA, TR CU, CQST, INMETRO, CCOE Zone 0, 1, 2, 20, 21, 22, weatherproof Ex II 2 GD, Ex d IIC T5/T6 Gb Ex tb IIIC T100C/T85C Db Ex II 1 GD, Ex ia IIC T4 Ga Class 1, Div. 1, Groups C, D (CSA Ex ia also includes groups A & B ) SIL2, Russian fire approval, ABS -55C to +70C* IP66, IP67 & IP68, NEMA 4X & 6 Stainless steel or alloy Up to 4 x M20, M25, 1/2" NPT or 3/4" NPT Stainless: 3.8kg. Alloy: 2.5kg 2 pole c/o (Up to 4 pole c/o available) Switch action, labels, LED, EOL and series resistors, diodes, 3 or 4 pole switches, colour SM87BG Ex d & Ex ia Break glass call points Certification Area classification ATEX/IEC classification UL/NEC classification Approvals Certified temperature Ingress protection Material Entries Weight Switches Options ATEX, IECEx, CSA, TR CU, CQST, INMETRO, CCOE Zone 0, 1, 2, 20, 21, 22, weatherproof Ex II 2 GD, Ex d IIC T5/T6 Gb Ex tb IIIC T100C/T85C Db Ex II 1 GD, Ex ia IIC T4 Ga Class 1, Div. 1, Groups C, D (CSA Ex ia also includes groups A, B) Russian fire approval -55C to +70C* IP66, 67, NEMA 4X & 6 Stainless steel or alloy Up to 4 x M20, M25, 1/2" NPT or 3/4" NPT Stainless: 3.8kg. Alloy: 2.5kg 2 pole c/o (Up to 4 pole c/o available) Switch action, labels, LED, EOL and series resistors, diodes, 3 or 4 pole switches, colour PH1 Ex d Pull handle call point Certified temperature Ingress protection Material Entries Weight Switches Options ATEX, IECEx, cULus Zone 1, 2, 21, 22 & weatherproof Ex II 2 GD, Ex d IIC T6 Gb, Ex tb IIIC T85C Db Class I, Div. 1, Groups B, C, D Class I, Div. 2, Groups A, B, C, D -55C to +70C* IP66, 67, NEMA 4X & 6 Corrosion free GRP (UL Class I, Div. 1 Inner Cover: 316 stainless steel) Up to 2 x M20, M25, 1/2" NPT or 3/4" NPT UL Class I, Div 2/ATEX/IECEx/UW: 2.6Kg UL Class I, Div. 1: 3.8Kg 1 or 2 pole c/o EOL and series resistors, diodes, labels, body colour mm 2 200mm 2 Certification Area classification ATEX/IEC classification UL/NEC classification mm *Model dependent EATON signalling and alarms product overview 7 Hazardous area manual alarm call points PB Ex de & Ex ia Push button call points Certification Area classification ATEX/IEC classification UL/NEC classification Approvals Certified temperature Ingress protection Material Entries Weight Switches Options ATEX, IECEx, cULus, CSA, TR CU, CQST, INMETRO, CCOE Zone 0, 1, 2, 20, 21, 22, weatherproof Ex II 2 GD,Ex de(mb) IIC T4/T6*Ex tb IIIC T120C Db Ex II 1 GD, Ex ia IIC T4 GaEx ia IIIC T135C Da Class I, Div. 2, Groups A, B, C, D Class II, Div. 2, Groups F, G SIL2, Russian fire approval, ABS -50C to +70C* IP66, 67, NEMA 4X & 6 Corrosion free GRP Up to 4 x M16, M20 or 1/2" NPT 1.2kg* 1 or 2 pole c/o Labels, LED, EOL and series resistors, diodes, Earth continuity, switch action, number of terminals, colour 120mm 2 126mm 2 BG Ex de & Ex ia Break glass call points UL/NEC classification Approvals Certified temperature Ingress protection Material Entries Weight Switches Options ATEX, IECEx, cULus, TR CU, CQST, INMETRO, CCOE Zone 0, 1, 2, 20, 21, 22, weatherproof Ex II 2 G, Ex de (mb) IIC T4/T6* Ex II 1 GD, Ex ia IIC T4 Ga, Ex ia IIIC T135C Da Class I, Div. 2, Groups A, B, C, D SIL2, Russian fire approval, CCCF -50C to +70C * IP66, 67, NEMA 4X & 6 Corrosion free GRP Up to 4 x M16, M20 or 1/2" NPT 1.2kg* 1 or 2 pole c/o Labels, switches, LED, Lift flap, EOL and series resistors, diodes, Earth continuity, plastic element, break glass hammer, colour 120mm 2 126mm 2 Certification Area classification ATEX/IEC classification BG2 Ex de & Ex ia Break glass call points Certified temperature Ingress protection Material Entries Weight Switches Options ATEX Zone 0, 1, 2, 20, 21, 22, weatherproof Ex II 2 G, Ex de (mb) IIC T4/T6* Ex II 1 GD, Ex ia IIC T4 Ga , Ex ia IIIC T135C Da -40C to +70C* IP66 & IP67 Corrosion free GRP 2 x M20 1.2kg* 1 pole c/o EOL and series resistors, diodes, lift flap 120mm 2 126mm 2 Certification Area classification ATEX/IEC classification *Model dependent 8 EATON signalling and alarms product overview Hazardous area manual alarm call points BG3 Ex ia Break glass call points Certification Area classification ATEX/IEC classification Certified temperature Ingress protection Material Entries Weight Switches Options ATEX Zone 0, 1, 2, 20, 21, 22, weatherproof Ex II 1 G, EEx ia IIC T4 -55C to +55C IP66 & IP67 Corrosion free GRP 2 x M20 0.5kg 1 or 2 pole c/o Labels, EOL and series resistors, diodes, polycarbonate or stainless steel lift flap, LED, double switch, plastic element, colour Ex Fire alarm Switch LD Ex-Fire Alarm Switch Ex de Break glass & push button call point Certification Area classification ATEX/IEC classification Approvals Certified temperature Ingress protection Material Entries Weight Switches Options ATEX Zone 1, 2, 21, 22 Ex II 2 GD, Ex de mb IIC T5/T6 Gb Ex tb IIIC T100 C Db EN54-11, VDS -55C to +70C* IP66 Corrosion free GRP 1 x M16 & 1 x blank plug M16 1.8kg 2 pole c/o Resistors, colour 155mm 163mm 139mm *Model dependent EATON signalling and alarms product overview 9 Hazardous area beacons LD15 dSLB20-LED Page 12 XB11 Page 12 XB9 Page 14 XB15 Page 14 Page 16 Page 18 FL4 & FB4 Page 13 Page 14 Page 16 Page 15 Page 19 Page 15 Page 17 Page 19 Page 13 dSLB 20 XB16 FL12 & FB12 SM87HXB Page 13 XB10 XB8 FB11 & FL11 Page 18 ActiveLine GH5 BDK22 XB12 Page 16 SM87LED Page 12 BZ2/BD22 XB4 SM87 LU1/LU3 Expertline LED Page 15 TH12 Page 17 Page 17 FB15 Page 19 Eaton's range of beacons, including flashing, steady-state indicators and rotating units, provide solutions for potentially explosive and harsh environmental conditions. These may be used to warn of potential hazards or indicate the status of plant items, gas and oil leaks and evacuation alerts. The signals can be operated as stand-alone units or be incorporated into a wider system, such as a fire panel. Many units can also be customised with a choice of lens colours and can be painted to customer specification. Eaton offer a range of LED beacons, which have the added benefit of low energy consumption, an increased lifespan and an option of flash patterns. 10 EATON signalling and alarms product overview XB15 - 5J, 10J & 15J Eaton, pioneers in the latest technology, are pleased to announce the evolution of the XB15 beacon range In an emergency situation in a potentially explosive environment, it is paramount to have an effective warning system that you can depend on. Since its launch 10 years ago, the XB15 has proven to be the product of choice in the fire, flame, gas and telecom integration markets whenever strength, reliability and ease of installation are required. With a glass reinforced polyester body and borosilicate glass lens, the XB15 leads the way in signalling devices where the effects of adverse harsh environmental conditions and extreme temperatures of -55C to +70C demand the highest quality and performance possible. The effective candlepower of the 15J unit has been measured at 382cd, ensuring that our product will be effective no matter what the application. EATON signalling and alarms product overview 11 Hazardous area beacons LD15 Ex d LED beacon 240mm 5 150mm 3 Pipe mount 36 1 A/F Direct mount 20 1 90 1 118mm 2 118mm 2 90 1 240mm 240mm 5 5 dSLB20-LED 239mm 5 Approvals Certified temperature Ingress protection Material Entries Weight Voltage Light source LED life Options 118mm 2 210 2 UL/NEC classification ATEX, IECEx, cULus, ULC, TR CU, CQST, INMETRO Zone 1, 2, 21, 22, weatherproof Ex II 2GD, Ex db IIC T5/T6 Gb Ex tb IIIC T100C/T85C Db Class I, Div. 2, Groups A*, B*, C, D Class II, Div. 2, Groups F, G Class I, Zone 1, AEx d IIC* & IIB, Ex d IIB SIL1 (1oo1) & SIL2 (1oo2) -55C to +70C IP66 & IP67, NEMA 4X & 6 Corrosion free GRP Up to 3* x M20, M25, 1/2" NPT or 3/4" NPT Direct: 3.5Kg. Pipe: 3.1Kg 12-48Vdc, 110-254Vac LED 54,000 hours Lens colour, lens guard, mounting, tag & duty label, relay initiate, telephone initiate, body colour 239mm 239mm 5 5 Certification Area classification ATEX/IEC classification Ex de LED beacon 150mm 3 20 1 O110mm 90 1 20 1 90 1 130mm 90 1 90 1 36 1 A/F 36 1 A/F 150mm 3 210 2 ATEX, IECEx, TR CU, INMETRO Zone 1, 2, 21, 22, weatherproof Ex II 2GD, Ex d e IIC T6 Gb, Ex tb IIIC T80C Db ICAO -55C to +55C IP66 & IP67 Aluminium 1x M20 and 1x blank plug M20 2kg 24-48Vdc, 85-265Vac LED LED colour 210 2 Certification Area classification ATEX/IEC classification Approvals Certified temperature Ingress protection Material Entries Weight Voltage Light source Options Expertline LED Ex em LED light Certification Area classification ATEX/IEC classification UL/NEC classification Approvals Certified temperature Ingress protection Material Entries Weight Voltage Light source Options ATEX, IECEx, cULus, TR CU, INMETRO Zone 1, 2, 21, 22, weatherproof Ex II 2G, Ex e mb [ib] IIC T4 Gb Ex II 2D, Ex mb t IIIC IP66 T130C Db Class I, Div. 2, Groups A, B, C, D, T4 Class I, Zone 2, Groups IIA, IIB, IIC, T4 ICAO -40C to +65C* IP66, NEMA 4X Polycarbonate 2 x M20 & 1 x blank plug M20 2.5kg 24Vdc, 120-230Vac LED LED colour, ICAO obstruction light version 299mm 185mm *Model dependent 12 EATON signalling and alarms product overview Hazardous area beacons SM87LED Ex d LED beacon Certification Area classification ATEX/IEC classification Approvals Certified temperature Operating temperature Ingress protection Material Entries Weight Voltage Light source Options ATEX, IECEx, TR CU, INMETRO, CCOE Zone 1, 2, 21, 22, weatherproof Ex II 2GD, Ex d IIC T6 Gb, Ex tb IIIC T70C Db SIL2, Russian fire approval -55C to +55C -20C to +55C IP66 & IP67 Stainless steel or alloy Up to 4 x M20 or M25 Alloy: 2kg. Stainless steel: 3.8kg 24-48Vdc LED LED colour, lens guard, tag/duty label, telephone initiate, relay initiate, EOL resistor, body colour ActiveLine GH5 Ex nR Multicolour LED beacon Certification Area classification ATEX/IEC classification Certified temperature Ingress protection Material Entries Weight Voltage Light source Options ATEX Zone 2, 22, weatherproof Ex II 3G, Ex nR IIC T6 Gc Ex II 3D, Ex tc IIIC T85C Dc -20C to +50C IP66 Polycarbonate 1 x M20 & 2 x blank plug M20 1.4kg 24Vdc, 230Vac Multicolour LED Flash function, LED colour 295mm 185mm SM87HXB 5 joule Ex d xenon beacon Certification Area classification ATEX/IEC classification UL/NEC classification Approvals Certified temperature Ingress protection Material Entries Weight Voltage Light source Options ATEX, IECEx, cULus, CSA, TR CU, CQST, INMETRO, CCOE Zone 1, 2, 21, 22, weatherproof Ex II 2GD, Ex d IIC T5/T6 Gb Ex tb IIIC T95C/T80C/T65C Db Class I, Div. 1, Groups C, D Class I, Zone 1, Aex d IIB, Exd IIB SIL2, Russian fire approval -55C to +70C IP66 & IP67, NEMA 4X & 6 Stainless steel or alloy Up to 4 x M20, M25, 1/2" NPT or 3/4" NPT Alloy: 2.0kg. Stainless steel: 3.8kg 24-48Vdc, 110-254Vac Xenon Lens colour, lens guard, tag/duty label, telephone initiate, relay initiate, EOL resistor, body colour EATON signalling and alarms product overview 13 Hazardous area beacons XB11 5 joule Ex d xenon beacon Certification Area classification ATEX/IEC classification UL/NEC classification Approvals Certified temperature Ingress protection Material Entries Weight Voltage Light source Options ATEX, IECEx, cULus, TR CU, CQST, INMETRO, CCOE Zone 1, 2, 21, 22, weatherproof Ex II 2GD, Ex d IIB T4/T5/T6 Gb Ex tb IIIC T110C/T85C/T70C Db Class I, Div. 2, Groups C, D Class I, Zone 1, AEx d IIB, Ex d IIB Russian fire approval, CSFM -55C to +70C IP66 & IP67, NEMA 4X & 6 Corrosion free GRP 2 x M20 or 1/2" NPT 2.5kg 24-48Vdc, 110-240Vac Xenon Flash rate, lens colour, lens guard, mounting, earth continuity, tag/duty label, telephone initiate, body colour XB9 5 joule Ex d xenon beacon Certification Area classification ATEX/IEC classification Approvals Certified temperature Ingress protection Material Entries Weight Voltage Light source Options ATEX, IECEx, TR CU, CQST Zone 1, 2, weatherproof Ex II 2G, Ex d IIC T5/T6 Gb Russian fire approval -55C to +55C IP66 & IP67 Corrosion free GRP 1 x M20, PG13.5, 3m cable tail 1.6kg 12-60Vdc, 110-254Vac Xenon Flash rate, lens colour, tag/duty label, body colour O81mm 2 248mm 82mm BZ2/BD22 15 joule Ex nR xenon beacon Certification Area classification ATEX/IEC classification Certified temperature Ingress protection Material Entries Weight Voltage Light source Options ATEX Zone 2, 22, weatherproof Ex II 3G, Ex nR IIC T5/T4 Gc Ex II 3D, Ex tc IIIC T85C Dc -20C to +50C* IP66 Polycarbonate 1 x M20 & 1 x blank plug 1.4kg 12-24Vdc, 120-230Vac Xenon Lens colour 299mm 185mm *Model dependent 14 EATON signalling and alarms product overview Hazardous area beacons BDK22 5 joule Ex td xenon beacon Certification Area classification ATEX/IEC classification Certified temperature Ingress protection Material Entries Weight Voltage Light source Options ATEX Zone 22, weatherproof Ex II 3D, Ex tc IIIB T85C Dc -20C to +50C IP54 Aluminium 1x M20 0.7kg 24vdc, 230Vac Xenon Lens colour 135mm 130mm XB10 10 & 15 joule Ex d(e) xenon beacons Certification Area classification ATEX/IEC classification Approvals Certified temperature Ingress protection Material Entries Weight Voltage Light source Options ATEX, IECEx, TR CU, INMETRO, CCOE Zone 1, 2, weatherproof Ex II 2G, Ex d IIB T4 Gb, Ex II 2G, Ex de IIB T4 Gb Russian fire approval 10 joule: -55C to +65C* 15 joule: -55C to +50C* IP66 & IP67 Corrosion free GRP Ex d: Up to 2 x M20, PG13.5 Ex de: 3 x M20 Ex d: 2.8kg. Ex de: 3.6kg 24-48Vdc, 110-254Vac Xenon Tube energy, lens colour, tag/duty label, telephone initiate, earth continuity, cable tail, body colour O122mm2 357mm5 299mm4 dSLB 20 5 & 15 joule Ex de xenon beacons Certification Area classification ATEX/IEC classification Certified temperature Ingress protection Material Entries Weight Voltage Light source Options ATEX, IECEx, TR CU, INMETRO Zone 1, 2, 21, 22, weatherproof Ex II 2GD, Ex d e IIC T5/T6 Gb Ex tb IIIC T80C/T95C Db -55C to +55C IP66 & IP67 Aluminium 1x M20 & 1 x blank plug M20 2kg 12-80Vdc, 115-230Vac Xenon Tube energy, lens colour O110mm 130mm *Model dependent EATON signalling and alarms product overview 15 Hazardous area beacons XB15 5, 10 & 15 joule Ex d xenon beacons 240mm 5 150mm 3 XB4 21 joule Ex d(e) xenon beacon Certification Area classification ATEX/IEC classification UL/NEC classification Approvals Certified temperature Ingress protection Material Entries Weight Voltage Light source Options ATEX, IECEx, cULus, TR CU, CCOE Zone 1, 2, 21, 22, weatherproof Ex II 2GD, Ex d IIC T4/T5/T6 Gb Ex tb IIIC T135C/T100C/T85C Db Ex II 2GD, Ex de IIC Ex tD A21 T4/T5 Class I, Div. 1, Groups C, D Class I, Zone 1, Groups IIB & IIA Russian fire approval -55C to +70C IP66 & IP67, NEMA 4X & 6 Stainless steel or alloy Up to 4* x M20, M25, 1/2" NPT or 3/4" NPT Alloy: 6.6kg -7.6kg. Stainless steel: 15kg - 16kg 24-110Vdc, 110-254Vac Xenon Flash rate, telephone initiate, relay initiate, lens guard, lens colour, tag/duty label, body colour XB12 21 joule Ex d xenon beacon Certification Area classification ATEX/IEC classification UL/NEC classification Approvals Certified temperature Ingress protection Material Entries Weight Voltage Light source Options ATEX, IECEx, cULus, TR CU, CQST, INMETRO, CCOE Zone 1, 2, weatherproof Ex II 2G, Ex d IIB T4/T5/T6 Gb Class I, Div. 2, Groups C, D Class I, Zone 1, AEx d IIB, Ex d IIB Russian fire approval, CSFM, UL Marine -55C to +70C IP66 & IP67, NEMA 4X & 6 Corrosion free GRP 2 x M20 or 1/2" NPT 7.0kg 24Vdc, 110-240Vac Xenon Body & lens colour, lens guard, tag & duty labels, telephone initiation, flash rate, mounting method, earth continuity *Model dependent 16 EATON signalling and alarms product overview Direct mount 36 1 A/F 20 1 Direct mount 90 1 Approvals Certified temperature Ingress protection Material Entries Weight Voltage Light source Options 90 1 UL/NEC classification 118mm 2 239mm 5 Area classification ATEX/IEC classification ATEX, IECEx, cULus, ULC, TR CU, CQST, INMETRO, CCOE Zone 1, 2, 21, 22, weatherproof Ex II 2GD, Ex db IIC T4/T5/T6 Gb Ex tb IIIC T135C/T100C/T85C Db Class I, Div. 2, Groups A*, B*, C, D Class II, Div. 2, Groups F, G Class I, Zone 1 AEx d IIC* & IIB, Ex d IIB SIL1, EN54-23, Russian fire approval, CCCF, CSFM -55C to +70C IP66 & IP67, NEMA 4X & 6 Corrosion free GRP Up to 3* x M20, M25, 1/2" NPT or 3/4" NPT 2.6kg - 3.0kg 24-48Vdc, 110-254Vac Xenon Tube energy, flash rate, lens colour, lens guard, mounting, tag & duty label, relay initiate, telephone initiate, body colour 210 2 Certification Hazardous area beacons XB8 0.5 joule Ex ia xenon beacon Certification Area classification ATEX/IEC classification Approvals Certified temperature Ingress protection Material Entries Weight Voltage Light source Options ATEX, IECEx, TR CU, CCOE Zone 0, 1, 2, weatherproof Ex II 1G, Ex ia IIC/IIB T4 Ga ABS -55C to +60C IP66 & IP67 Body: corrosion free GRP. Lens: polycarbonate Up to 3 x M20 via knockouts 1.4kg 12-24Vdc Xenon Lens colour, tag & duty label, body colour XB16 10 joule UL xenon beacon Certification Area classification UL/NEC classification Approvals Certified temperature Ingress protection Material Entries Weight Voltage Light source Options cULus Hazardous locations, ordinary locations Class I, Div. 2, Groups A, B, C, D Class II, Div. 2, Groups F, G UL1971, CSFM -55C to +70C IP66 & IP67, NEMA 4X & 6 Corrosion free GRP 1 x 3/4" NPT 1.0kg 24-48Vdc, 110-254Vac Xenon Flash rate, lens colour, lens guard, tag & duty label, relay initiate, body colour TH12 Ex d rotating beacon Certification Area classification ATEX/IEC classification Certified temperature Ingress protection Material Entries Weight Voltage Light source Options ATEX, IECEx, TR CU, INMETRO Zone 1, 2, weatherproof Ex II 2G, Ex d IIB T3/T4 Gb -55C to +70C IP66 & IP67 Corrosion free GRP 2 x M20 7.6kg 12-24Vdc, 110-240Vac Rotating tungsten halogen Rotation speed, lens colour, lens guard, mounting, tag & duty label, earth continuity, body colour EATON signalling and alarms product overview 17 Hazardous area beacons SM87LU1/LU3 Ex d Steady beacons Certification Area classification ATEX/IEC classification UL/NEC classification Approvals Certified temperature Operating temperature Ingress protection Material Entries Weight Voltage Light source Options ATEX, IECEx, cULus, CSA, TR CU, CQST, INMETRO Zone 1, 2, 21, 22, weatherproof SM87LU1:Ex II 2GD, Ex d IIC T6 Gb, Ex tb IIIC T85C Db SM87LU3:Ex II 2GD, Ex d IIC T3/T4/T5/T6 Gb Ex tb IIIC T155C/T130C/T100C/ T85C Db Class I, Div. 1, Groups C, D Class I, Zone 1, Aex d IIB, Exd IIB Russian fire approval SM87LU1: -55C to +55C SM87LU3: -55C to +70C SM87LU1: -20C to +55C SM87LU3: -55C to +70C IP66 & IP67, NEMA 4X & 6 Stainless steel or alloy SM87LU1: Up to 3 x M20, M25, 1/2" NPT or 3/4" NPT SM87LU3: Up to 4 x M20, M25, 1/2" NPT or 3/4" NPT Alloy: 2.5kg. Stainless steel: 3.8kg 24-48Vdc, 110-254Vac Filament, fluorescent Lens colour, lens guard, tag/duty label, body colour FL4 & FB4 Ex d(e) Steady beacons Certification Area classification ATEX/IEC classification UL/NEC classification Certified temperature Operating temperature Ingress protection Material Entries Weight Voltage Light source Options ATEX, IECEx, cULus, TR CU Zone 1, 2, 21, 22, weatherproof FB4: Ex II 2GD, Ex d IIC T3/T4/T5 Gb Ex tb IIIC T185C/T135C/T100C Db FB4: Ex II 2GD, Ex de IIC Ex tD A21 T3/T4/T5 FL4: Ex II 2GD, Ex d IIC T4/T5/T6 Gb Ex tb IIIC T135C/T100C/T85C Db FL4: Ex II 2GD, Ex de IIC Ex tD A21 T4/T5/T6 Class I, Div. 1, Groups C, D Class I, Zone 1, Groups IIB & IIA -55C to +70C FL4: -20C to +70C FB4: -55C to +70C IP66 & IP67, NEMA 4X & 6 Stainless steel or alloy Up to 4* x M20, M25, 1/2" NPT or 3/4" NPT Alloy: 6.5kg - 8.9kg Stainless steel: 14.9kg - 17.3kg 24-48Vdc, 110-254Vac Filament, fluorescent Lamp wattage, lens colour, lens guard, tag & duty labels, relay initiate, body colour *Model dependent 18 EATON signalling and alarms product overview Hazardous area beacons FB11 & FL11 Ex d Steady beacons Certification Area classification ATEX/IEC classification UL/NEC classification Approvals Certified temperature Operating temperature Ingress protection Material Entries Weight Voltage Light source Options ATEX, IECEx, cULus, TR CU, INMETRO Zone 1, 2, 21*, 22*, weatherproof Ex II 2GD, Ex d IIB T4/T5/T6 Gb Ex tb IIIC T110C/T85C/T70C Db Class I, Div. 2, Groups C, D Class I, Zone 1, AEx d IIB, Ex d IIB Russian fire approval -55C to +70C FB11: -55C to +70C FL11: -20C to +70C IP66 & IP67, NEMA 4X & 6 Corrosion free GRP 2 x M20 or 1/2" NPT 2.8kg 24-48Vdc, 110-254Vac Filament, fluorescent Lamp wattage, lens colour, lens guard, mounting, earth continuity, tag & duty labels, body colour FL12 & FB12 Ex d Steady beacons Certification Area classification ATEX/IEC classification UL/NEC classification Approvals Certified temperature Ingress protection Material Entries Weight Voltage Light source Options ATEX, IECEx, cULus, TR CU, INMETRO Zone 1, 2, weatherproof FB11: Ex II 2G, Ex d IIB T3/T4/T5 Gb FL11: Ex II 2G, Ex d IIB T4/T5/T6 Gb Class I, Div. 2, Groups C, D Class I, Zone 1, AEx d IIB, Ex d IIB Russian fire approval FB12: -55C to +55C FL12: -20C to +70C IP66 & IP67, NEMA 4X & 6 Corrosion free GRP 2 x M20 or 1/2" NPT 7.2kg - 7.6kg 24-48Vdc, 110-254Vac Filament, fluorescent Lamp wattage, lens colour, lens guard, mounting, earth continuity, tag & duty labels, body colour FB15 Ex d Steady beacon 240mm 5 150mm 3 Pipe mount 90 1 36 1 A/F 20 1 Direct mount *Model dependent 90 1 Approvals Certified temperature Ingress protection Material Entries Weight Voltage Light source Options 118mm 2 239mm 5 UL/NEC classification ATEX, IECEx, cULus, TR CU, INMETRO Zone 1, 2, 21, 22, weatherproof Ex II 2GD, Ex db IIC T3/T4 Gb Ex tb IIIC T200C/T135C Db Class I, Div. 2, Groups A*, B*, C, D Class I, Zone 1 AEx d IIC* & IIB, Ex d IIB Russian fire approval, CSFM -55C to +70C IP66 & IP67, NEMA 4X & 6 Corrosion free GRP Up to 3* x M20, M25, 1/2" NPT or 3/4" NPT Pipe: 2.6Kg. Direct: 3.0Kg 24-48Vdc, 110-254Vac Filament Lamp wattage, lens colour, lens guard, mounting, tag & duty label, lens colour 210 2 Certification Area classification ATEX/IEC classification EATON signalling and alarms product overview 19 Industrial beacons BLK-LED BLK-Super-LED Page 21 ActiveLine GH2 Page 21 Alpha 1/2/3 & 4 Page 22 BLE 15 BLG-LED Page 21 Profiflash Page 23 BLK Page 24 BLE-LED Page 22 XB13 Page 23 BLS Page 24 ActiveLine GH1 BLG 10 Page 23 SLD1/SLD2 Page 25 Page 22 Page 24 Profilux Page 25 Page 25 Eaton's range of weatherproof flashing beacons and status lights, including single colour or multi coloured options, can be either flashing, steady-state indicators or rotating units, providing solutions for harsh safe area environmental conditions. These may be used to warn of potential hazards or indicate the status of plant items, gas and oil leaks and evacuation alerts in safe areas. The signals can be operated as stand-alone units or be incorporated into a wider system, such as a fire panel. Many units can also be customised with a choice of sources or lens colours. We now offers a comprehensive range of LED beacons, which have the added benefit of low energy consumption, an increased lifespan and an option of flash patterns. 20 EATON signalling and alarms product overview Industrial beacons BLK-LED Weatherproof LED beacon Area classification Operating temperature Ingress protection Material Entries Weight Voltage Light source Options Weatherproof -30C to +50C IP65 Aluminium Up to 2 x M20 0.7kg 12-24Vdc, 230Vac LED Flash function, lens colour 107mm 0x M2 130mm BLK-Super-LED Weatherproof LED beacon Area classification Operating temperature Ingress protection Material Entries Weight Voltage Light source Options Weatherproof -55C to +75C IP65 Aluminium Up to 2 x M20 1.4kg 24Vdc, 230Vac LED Flash function, lens colour 107mm 0x M2 130mm BLG-LED Weatherproof LED beacon Area classification Operating temperature Ingress protection Material Entries Weight Voltage Light source Options Weatherproof -40C to +50C IP67 Body: rubber Lens: polycarbonate Cable diameter 6-8mm 0.45kg 12-24Vdc, 115-230Vac LED Flash function, LED colour 160mm O150mm O120mm EATON signalling and alarms product overview 21 Industrial beacons BLE-LED Weatherproof LED beacon Area classification Operating temperature Ingress protection Material Entries Weight Voltage Light source Options Weatherproof -40C to +65C IP66 Polycarbonate 1 x cable gland M20 & 2 x blank plugs M20 1.3kg 24Vdc, 85-265Vac LED Flash function, lens colour O97mm 314mm ActiveLine GH1 Multicolour weatherproof LED beacon Area classification Operating temperature Ingress protection Material Entries Weight Voltage Light source Options Weatherproof -25C to +60C IP54 Enclosure & footbracket: thermoplastic Stand: aluminium Lens: polycarbonate Male thread bush M16 0.3kg 24Vdc, 230Vac Multicolour LED With/without sounder, flash functions, LED colour 300mm O70mm ActiveLine GH2 75 204mm 29 40,5 Entries Weight Voltage Light source Options Weatherproof -25C to +60C IP54 Enclosure: thermoplastic Lens: polycarbonate 1 x M16 0.3kg 24Vdc, 230Vac Multicolour LED Flash function, LED colour 69 Area classification Operating temperature Ingress protection Material 204 Multicolour weatherproof LED beacon O 68,5 55 22 EATON signalling and alarms product overview 100mm Industrial beacons Alpha 1, Alpha 2, Alpha 3 & Alpha 4 LED Obstruction light Area classification Approvals Operating temperature Ingress protection Material Entries Weight Voltage Light source Options Weatherproof ICAO annex 14 (low intensity) -20C to +50C IP65 Body: rubber Lens: polycarbonate Cable diameter 6-8-mm (Alpha 2-4 prewired) 0.5kg - 4.5kg* 24Vdc, 115-230Vac LED Mounting Alpha 2 / Alpha 3 and Alpha 4 shown 366,5mm 221mm 135mm 135mm 142mm 142mm Alpha 2 and Alpha 3 shown Profiflash 5 joule weatherproof beacon Area classification Operating temperature Ingress protection Material Entries Weight Voltage Light source Options Weatherproof -20C to +40C IP54 Housing: ABS Lens: polycarbonate Male thread bush M16 0.36kg 24Vdc, 230Vac Xenon Lens colour, housing colour, mounting options 227mm 109mm XB13 10 joule weatherproof xenon beacon Area classification Operating temperature Ingress protection Material Entries Weight Voltage Light source Options Weatherproof -40C to +70C IP66 & IP67 Body: corrosion free GRP Lens: polycarbonate Up to 3 x M20 via knockouts 1.1kg 12-48Vdc, 115-230Vac Xenon Body & lens colour, tag & duty labels, lens guard, telephone & relay initiate, single & dual flash mode *Model dependent EATON signalling and alarms product overview 23 Industrial beacons BLG 10 10 joule weatherproof beacon Area classification Operating temperature Ingress protection Material Entries Weight Voltage Light source Options Weatherproof -20C to +50C IP67 Body: rubber Lens: polycarbonate Cable diameter 6-8mm 0.45kg 10-100Vdc, 20-230Vac Xenon Lens colour 160mm O150mm O120mm BLE 15 15 joule weatherproof beacon Area classification Operating temperature Ingress protection Material Entries Weight Voltage Light source Options Weatherproof -40C to +50C IP66 Polycarbonate 1 x cable gland M20 & 2 x blank plugs M20 1.0kg 24vdc, 230Vac Xenon Lens colour O97mm 314mm BLK 5 & 15 joule weatherproof beacons Area classification Operating temperature Ingress protection Material Entries Weight Voltage Light source Options Weatherproof -50C to +50C* IP65 Aluminium Up to 2 x M20 0.7kg 12-48Vdc, 24-230Vac Xenon Tube energy, temperature range, lens colour 107mm 0x M2 130mm *Model dependent 24 EATON signalling and alarms product overview 1.5 Industrial beacons BLS 5 & 15 joule weatherproof beacons Area classification Operating temperature Ingress protection Material Entries Weight Voltage Light source Options Weatherproof -30C to +50C IP54 ABS 1x self-sealing grommet M16 0.7kg 12-24Vdc, 24-230Vac Xenon Tube energy, lens colour 204mm 86mm SLD1/SLD2 Weatherproof rotating halogen beacons Area classification Approvals Operating temperature Ingress protection Material Entries Weight Voltage Light source Options Weatherproof German Federal Office for Motor Traffic -20C to +50C IP54 Plastic socket with die cast metal bottom (for SLD 1 and 3) and full-surface PVC sealing Cable diameter 8-12mm 1.0kg - 2.3kg* SLD1: 12-24Vdc, 110-230Vac SLD2: 12-24Vdc Halogen bulb 55/70W Lens colour 120mm 215mm 250mm 160mm 135mm 130mm Profilux Weatherproof steady beacon Area classification Operating temperature Ingress protection Material Entries Weight Voltage Light source Options Weatherproof -20C to +40C IP54 ABS Male thread bush M16 0.36kg 24vdc, 230Vac Filament 15W Housing colour, lens colour, mounting 227mm 109mm *Model dependent EATON signalling and alarms product overview 25 Hazardous area sounders DB1P DB3B Page 28 DB7 dEV 20 Page 28 DB6 Page 29 Page 29 dGW21/dRGW21 Page 30 mHP11 mHG 11 Page 31 DB5 Page 30 Page 29 dGH 21 / dRGH 21 Page 30 mHP12 Page 31 Page 31 The MEDC and FHF range of sounders are suitable for a wide variety of applications and feature a selection of tone settings and traditional bells. Sounders are used to warn of potentially dangerous situations or to relay instructions. In addition the alarms may operate as stand-alone units or be incorporated into a hazard warning system. A wide variety of sound output levels and other options are also available. The sounders output in dB is measured to European standards at 1 metre. 26 EATON signalling and alarms product overview Hazardous area sounder The MEDC DB3B, the latest addition to the sounder range boasts improved functionality and performance; including a higher output than the DB3, with SPL reaching 122dB @ 1m (+/-3dB). This significantly improves sound coverage in high noise environments, and ensures that our product will be effective in almost any application. The DB3B is ATEX, IECEx, INMETRO, cULus, TR CU, CQST, CCOE, CCCF and SIL 1 certified, and can be purchased as part of a beacon/sounder combination unit (please contact Eaton for details). In addition, it is available as either a flameproof enclosure (Ex d), or increased safety unit (Ex de), as well as protection against Gas or Gas & Dust atmospheres, allowing for greater flexibility to suit most specifications. ** Maximum output of 122dB @1m ** Certified -55C to +70C ** ATEX, IECEx, cULus, TR CU, CQST, CCOE, CCCF, SIL 1 & INMETRO certified ** Improved current consumption (329mA at nominal 24Vdc low inrush) ** Increased room in terminal chamber ** Drivers tested for over 1500 hours at full power ** Ex d/ Ex de units available ** Gas/ Gas & Dust units available ** Increased room in terminal chamber ** Improved control options ** 28 user selectable tones EATON signalling and alarms product overview 27 Hazardous area sounders DB1P Ex d Sounder Certification Area classification ATEX/IEC classification NEC classification Approvals Certified temperature Ingress protection Material Entries Weight Voltage Sound output Tones Stages Options ATEX, IECEx, cULus, TR CU, CCOE Zone 1, 2, weatherproof Ex II 2G, Ex d IIB T5/T6 Class I, Div. 1, Groups C, D SIL1, Russian fire approval -25C to +70C IP66, NEMA 4X Stainless steel or alloy Up to 3 x M20, M25, 1/2" NPT or 3/4" NPT 3.5kg - 12.7kg* 12-48Vdc, 110-240Vac Max: 110dB, 1m (3dB)* 27 2* Output level, entries, tag & duty labels, telephone or relay initiate, remote tone select, EOL resistor, colour DB3B Ex d(e) Sounder Approvals Certified temperature Ingress protection Material Entries Weight Voltage Sound output Tones Stages Options 280mm 3 *Model dependent 28 EATON signalling and alarms product overview 200mm 2 UL/NEC classification ATEX, IECEx, cULus, TR CU, CQST, INMETRO, CCOE Zone 1, 2, 21, 22*, weatherproof Ex II 2G, Ex d IIC T4/T5/T6 Gb Ex II 2GD, Ex d IIC T4/T5/T6 Gb Ex tb IIIC T135C/T100C/T85C Db Ex II 2G, Ex de IIC T4/T5/T6 Gb Ex II 2GD, Ex de IIC T4/T5/T6 Gb Ex tb IIIC T135C/T100C/T85C Db Class I, Div. 2, Groups A, B, C, D Class II, Div. 2, Groups F, G SIL1, Russian fire approval, CCCF, CSFM -55C to +70C IP66 & IP67, NEMA 4X & 6 Body: corrosion free GRP Flare: thermoplastic Up to 2 x M20 or 1/2" NPT Ex d: 4.6kg (based on long flare unit) Ex de: 5.4kg (based on long flare unit) 12-48Vdc, 110-254Vac Max: 122dB, 1m (3dB)* 28 3 (5 voltage free) Tag & duty labels, swivel bracket, EOL resistor, Earth continuity, tone activation method, voltage free activation, flare type, custom tones, flare colour 143mm 2 Certification Area classification ATEX/IEC classification Hazardous area sounders dEV 20 Ex de sounder Certification Area classification ATEX/IEC classification Certified temperature Ingress protection Material Entries Weight Voltage Sound output Tones Stages ATEX, IECEx, INMETRO Zone 1, 2, 21, 22, weatherproof Ex II 2G, Ex de IIB + H2 T6 Gb Ex II 2D, Ex tb IIIC T85C Db -50C to +60C IP66 Aluminium 1 x M20 2.8kg 24Vdc, 85-265Vac Max: 115dB, 1m (3dB) 32 2 345mm O144mm DB5 Ex ia Sounder Certification Area classification ATEX/IEC classification UL/NEC classification Certified temperature Ingress protection Material Entries Weight Voltage Sound output Tones Options ATEX, ATEX mining, IECEx, IECEx mining, FM, CSA, CCOE Zone 1, 2 Ex II 1G, Ex ia IIC T4 Ga Ex I M1, Ex ia I Ma Class I, Div. 2, Groups A, B, C, D -20C to +55C IP66 ABS Up to 2 x M20 via knockouts 0.3kg 12-24Vdc Max: 100dB, 1m (3dB) 26 Tag label, colour DB7 Ex ia Sounder Certification Area classification ATEX/IEC classification Approvals Certified temperature Ingress protection Material Entries Weight Voltage Sound output Tones Stages Options ATEX, TR CU, CCOE Zone 0, 1, 2, weatherproof Ex II 1G, Eex ia IIB/IIC T4* Russian fire approval -55C to +70C IP66 & IP67 Corrosion free GRP Up to 3 x M20 via knockouts 1.0kg 12-24Vdc* Max: 106dB, 1m (3dB)* 27 2 Tag & duty labels, colour *Model dependent EATON signalling and alarms product overview 29 Hazardous area sounders DB6 Ex d Bell Certification Area classification ATEX/IEC classification Certified temperature Ingress protection Material Entries Weight Voltage Sound output Options ATEX, IECEx Zone 1, 2 Ex II 2G, Ex d IIB T5 Gb -20C to +55C IP65 Cast iron 2 x M20 & 1 x blank plug M20 11.0kg 24Vdc, 240Vac Max: 106dB, 1m (3dB)* Tag label, colour 426mm 195mm dGW21/dRGW21 Ex de Bell Certification Area classification ATEX/IEC classification UL/NEC classification Certified temperature Ingress protection Material Entries Weight Voltage Sound output Options ATEX, UL, TR CU Zone 1, 2 Ex II 2 G, EEx de IIC T6 Class I, Div. 2, Groups A, B, C, D -20C to +40C IP66, NEMA 4X Corrosion free GRP 1 x M20 & 1 x blank plug 5.5kg 12-24Vdc, 110 - 240Vac Max: 105dB, 1m (3dB) Telephone relay, body colour 200mm 210mm 270mm 110mm dGH 21 / dRGH 21 Ex de Hooter Certification Area classification ATEX/IEC classification UL/NEC classification Certified temperature Ingress protection Material Entries Weight Voltage Sound output Options ATEX, UL, TR CU Zone 1, 2 Ex II 2 G, Ex de IIC T5/T6* Class I, Div. 2, Groups A, B, C, D -20C to +75C* IP66, NEMA 4X Corrosion free GRP 2 x M20 5.5kg 12-24Vdc, 110-240Vac Max: 105dB, 1m (3dB) Call relay, body colour 217mm 273mm *Model dependent 30 EATON signalling and alarms product overview Hazardous area sounders mHG 11 Ex em Hooter 132mm 1 146 Operating temperature Ingress protection Material Entries Weight Voltage Sound output ATEX, IECEx, INMETRO Zone 1, 2, 21, 22 II 2 G, Ex emb II T4/T5* II 2 D, Ex tD A21 IP66 T90C -55C to +70C (T4) IP66 Aluminium 1 x M20 2.0kg 24Vdc, 115Vac, 230Vac Max: 108dB, 1m (3dB) 331mm 331 Certification Area classification ATEX/IEC classification mHP11 Ex em Hooter Certification Area classification ATEX/IEC classification Operating temperature Ingress protection Material Entries Weight Voltage Sound output ATEX, IECEx, INMETRO Zone 1, 2 II 2 G, Ex emb II T4/T5* -20C to +70C* IP54 Polycarbonate 1 x M20 1.0kg 24Vdc, 115Vac, 230Vac Max: 108dB, 1m (3dB) 134mm 346mm mHP12 Ex em Hooter Certification Area classification ATEX/IEC classification Operating temperature Ingress protection Material Entries Weight Voltage Sound output ATEX, IECEx Zone 1, 2 II 2 G, Ex emb II T4/T5* -20C to +70C* IP54 Polycarbonate 1 x M20 1.0kg 24Vdc, 230Vac Max: 108dB, 1m (3dB) 133mm 152mm *Model dependent EATON signalling and alarms product overview 31 Industrial sounders DB12 DB15 Page 33 HP & HPO AW 1 - 6 Page 33 HPW 11 & HPW 12 Page 34 KS Page 36 AX05 Page 33 HGK Page 35 F0, FI, FII, FIII HGW11 EV 21/EV 24 AX08 PH1 Page 34 Page 35 Page 36 Page 38 UWE EKS/EKSP Page 35 EV 11 Page 37 Page 34 Page 36 AX03 Page 37 EV 21 voice Page 38 Page 38 Eaton offer a range of industrial sounders specifically designed for harsh environmental conditions. Designed to function in extreme temperatures, and with ingress protection ratings of up to IP66, these sounders have been engineered to consistently work in the harshest of environmental conditions. 32 EATON signalling and alarms product overview Page 37 Industrial sounders DB12 Weatherproof sounder Area classification Operating temperature Ingress protection Material Entries Weight Voltage Sound output Tones Stages Options Weatherproof -55C to +70C IP66 & IP67 Corrosion free GRP Up to 3 x M20 via knockouts 1.2kg 12-24Vdc, 115-230Vac Max: 110dB, 1m (3dB) 27 2* Tag & duty labels, body colour DB15 Weatherproof sounder Area classification Operating temperature Ingress protection Material Entries Weight Voltage Sound output Tones Stages Options Weatherproof -55C to +70C IP66 & IP67 Corrosion free GRP 2 x M20 & 1 x blank plug M20 2.6kg 12-48Vdc, 110-254Vac Max: 117dB, 1m (3dB) 27 Up to 2 Tag & duty labels, Earth continuity, EOL resistors, blank plug, colour AW 1-6 signalling bell 1 Weatherproof bell Area classification Operating temperature Ingress protection Material Entries Weight Voltage Sound output Options Weatherproof -20C to +60C IP55 Body: aluminium. Dome: steel 1 x M20 1.45kg - 2.95kg* 6-220Vdc, 12-240Vac* Max: 110dB, 1m (3dB)* Dome size, strike rate 130m 120m 250mm 110mm 130mm *Model dependent EATON signalling and alarms product overview 33 Industrial sounders UWE signalling bell Bell Area classification Operating temperature Ingress protection Material Entries Weight Voltage Sound output Industrial -10C to +55C IP40 Body: plastic. Dome: steel 1 x M20 1.2kg 18-30Vdc, 200-250Vac* Max: 96dB, 1m (3dB) O155mm 85mm PH1 Industrial pneumatic horn Area classification Operating temperature Material Weight Voltage Sound output Tones Industrial -25C to +40C Impact-resistant plastic 0.34kg 24Vdc, 230Vac* Max: 135dB, 1m (3dB) 400Hz operated with compressed air 375mm 100mm O125mm 80mm 60mm HP & HPO Area classification Operating temperature Ingress protection Material Entries Weight Voltage Sound output Options Weatherproof -20C to +60C IP43 Impact resistant thermoplastic (ABS) Cable diameter 5-8mm 0.185kg 6-220Vdc, 6-230Vac* Max: 92dB, 1m (3dB) Trumpet 152mm Weatherproof hooter 67mm 72mm 80mm *Model dependent 34 EATON signalling and alarms product overview 64mm 80mm 58mm Industrial sounders HPW 11 & HPW 12 Weatherproof hooter Area classification Operating temperature Ingress protection Material Entries Weight Voltage Sound output Options Weatherproof -20C to +60C IP55 Impact resistant thermoplastic (ABS) 1 x M20 self sealing grommet 1.1kg 6-230Vdc, 6-240Vac* Max: 108dB, 1m (3dB) Trumpet 14 134mm 128mm 346mm HGK Weatherproof hooter Area classification Operating temperature Ingress protection Material Entries Weight Voltage Sound output Weatherproof -20C to +60C IP65 Aluminium with ABS cover 1 x M20 1.75kg 24Vdc, 230Vac* Max: 108dB, 1m (3dB) 156mm 11 221mm 134mm HGW11 Weatherproof hooter Weatherproof -20C to +60C IP56 Aluminium 1 x M20 2.7kg 6-220Vdc, 6-240Vac* Max: 108dB, 1m (3dB) 133mm 128 Area classification Operating temperature Ingress protection Material Entries Weight Voltage Sound output HGW11 hooter 345mm M20 x 1,5 *Model dependent EATON signalling and alarms product overview 35 EKS / EKSP sounder Industrial sounders EKS/EKSP Weatherproof sounder Area classification Operating temperature Ingress protection Material Weight Voltage Sound output Options Weatherproof -20C to +70C IP30 Thermoplastic 0.05kg 24-48Vdc, 24-230Vac* Max: 90dB, 1m (3dB) Tone 43mm KS KS Siren LD Weatherproof motor siren Area classification Operating temperature Ingress protection Material Entries Weight Voltage Sound output Weatherproof -20C to +50C IP44 Thermoplastic 1 x M16 0.45kg 24Vdc, 230Vac* Max: 100dB, 1m (3dB) 100mm 86mm 147mm F0 FI FII FIII Weatherproof motor siren Area classification Operating temperature Ingress protection Material Entries O106mm IP22 (IP44 with protection cover) Aluminium F0,FI & FII: M16. FIIa & FIIIb: M20 1.6kg - 22.0kg* 24-230Vdc, 24-400Vac* Max: 123dB, 1m (3dB)* Protection cover 169mm ~ 235 Weight Voltage Sound output Options Weatherproof 0C (-40C with protection cover) to +65C F0 Siren O110mm F0 shown *Model dependent O 312 36 EATON signalling and alarms product overview 120 O5 Industrial sounders EV 21/EV 24 Weatherproof sounder 107mm 130mm EV 11 EV11 Weatherproof sounder Area classification Operating temperature Ingress protection Material Entries Weight Voltage Sound output Tones Options Weatherproof -25C to +50C IP55 Aluminium 2 x M20 & 2 x blank plugs M20 4.0kg 24Vdc, 24-230Vac* Max: 118dB, 1m (3dB) 7 tone, chime and voice Desktop microphone, pre-amplifier 340mm 84mm AX03 Weatherproof sounder Weatherproof -25C to +70C IP66 Plastic Up to 2 x M20 via knockouts AC: 0.4kg. DC: 0.3kg 9-60Vdc, 115-230Vac* Max: 105dB, 1m (3dB) 32 2 136mm 136mm Area classification Operating temperature Ingress protection Material Entries Weight Voltage Sound output Tones Stages 119mm *Model dependent EATON signalling and alarms product overview 37 183 Ingress protection Material Entries Weight Voltage Sound output Tones Stages Weatherproof EV 21: -25C to +60C EV 24: -50C to +60C IP54 Aluminium 1 x M20 1.7kg 12-24Vdc, 12-230Vac* Max: 105dB, 1m (3dB) 21 3 207 Area classification Operating temperature Industrial sounders AX05 Weatherproof sounder Weatherproof -25C to +70C IP66 Plastic Up to 2 x M20 via knockouts AC 0.7kg, DC 0.5kg 9-60Vdc, 115-230Vac* Max: 112dB, 1m (3dB) 32 2 165mm 136mm Area classification Operating temperature Ingress protection Material Entries Weight Voltage Sound output Tones Stages 132mm AX08 Weatherproof sounder Weatherproof -25C to +70C IP66 Plastic Up to 2 x M20 via knockouts AC 2.5kg, DC 1.6kg 24Vdc, 115-230Vac* Max: 120dB, 1m (3dB) 42 3 168mm 168mm Area classification Operating temperature Ingress protection Material Entries Weight Voltage Sound output Tones Stages 55mm EV 21 voice Weatherproof sounder Area classification Operating temperature Ingress protection Material Entries Weight Voltage Sound output Capacity Options Weatherproof -25C to +60C IP54 Aluminium 1 x M20 1.4kg 24Vdc, 85-265Vac Max: 105dB, 1m (3dB) 4GB storage 2nd entry 107mm 130mm *Model dependent 38 EATON signalling and alarms product overview 1.5 0x M2 Introducing the EV 21 Voice sounder The EV 21 V Voice Sounder is a compact electronic signalling device designed for both industrial and commercial applications for either internal or external use. Applications include production line and process control announcements or warnings, timed voice announcements and many others. The EV 21 V can provide up to eight different speech announcements that can be proceeded by an alert tone to attract the attention of the message recipient. An internal 4 GB micro SD memory card provides the non-volatile memory for the storage of both alert tones and messages accordingly. Message and alert tones are stored as WAV files and can be assigned different volume levels. The programming and configuration of the EV21 V is achieved using an easy to use PC based application for ease of programming and configuration even when installed using a via laptop via a USB interface. * * * * * * Capacity: Up to eight message announcements proceeded by alert tones Memory: 4GB Micro SD Memory Card Maximum Sound Pressure Level: 105dBA Power supply: 85-265 Vac or 24 Vdc Operating temperature: -25C to +60C Ingress protection: IP54 EATON signalling and alarms product overview 39 Hazardous area loudspeakers DB4B DB20C Page 42 DB10 DB20 Page 42 Page 43 DB16 Page 43 Page 43 Eaton's range of explosion protected, heavy duty, industrial and commercial speakers are designed to meet the requirements for public address, voice alarm and evacuation procedures. This range of loudspeakers, specifically designed for potentially explosive gas and dust atmospheres, is suitable for use in the harsh environmental conditions found offshore and onshore in the oil, gas and petrochemical industries. The units can be operated as part of 100 or 70 volt line systems, and include a wide range of sound output levels, which are all measured in dB at 1 watt / 1 metre. Eaton ensures the production of rugged, hard wearing products by using corrosion free materials such as GRP (glass reinforced polyester) and stainless steel. 40 EATON signalling and alarms product overview MEDC DB4B - 124dB loudspeaker The DB4B, a new high power, explosion proof loudspeaker launched by Eaton, offers a specific SPL figure of up to 124dB (for sensitivity of 25W @ 1m). The 8W and 15W units generate sufficient SPL (120dB and 122dB @1M respectively) to satisfy most specifications, allowing end users to install units with lower power consumption, therefore reducing the amount of application and support equipment required. With a range of certifications, including ATEX, IECEx, cULus, TR CU, CQST, INMETRO, CCOE, SIL 2 and DNV the DB4B is manufactured from a GRP Ex enclosure and rugged thermoplastic flare. The units are also certified for from -55C up to +70C*, ensuring that our products are suitable for safe use in the harshest working environments. intelligible. This allows the human voice to be heard and clearly understood, as demonstrated on the below frequency response chart. In addition, the new unit provides a clearer sound for sibilant consonants, allowing for much crisper and intelligible speech. The DB4B has an extended frequency response, ensuring that critical voice messages and general alarm tones are highly ** ATEX/IECEx/cULus/TR CU/CQST/ INMETRO/CCOE/SIL 2 and DNV certified ** Certified -55C to +70C* ** Gas/Gas & Dust units available ** Ex d/Ex de units available ** Extended frequency response *Model dependent EATON signalling and alarms product overview 41 Hazardous area loudspeakers DB4B Ex d(e) Loudspeaker Certification Area classification ATEX/IEC classification UL/NEC classification Approvals Operating temperature Ingress protection Material Entries Weight Sound output Transformer Wattage & transformer tappings Low impedance Options ATEX, IECEx, cULus, TR CU, CQST, INMETRO, CCOE Zone 1, 2, 21, 22*, weatherproof Ex II 2G, Ex d IIC T4/T5/T6 Gb Ex II 2GD, Ex d IIC T4/T5/T6 Gb Ex tb IIIC T135C/T100C/T85C Db Ex II 2G, Ex de IIC T4/T5/T6 Gb Ex II 2GD, Ex de IIC T4/T5/T6 Gb Ex tb IIIC T135C/T100C/T85C Db Class I, Div. 2, Groups A, B, C, D Class II, Div. 2, Groups F, G SIL2, Russian fire approval, DNV, CSFM -55C to +70C* IP66 & IP67, NEMA 4X & 6 Body: corrosion free GRP. Flare: thermoplastic Up to 2 x M20 or 1/2" NPT Ex d: 5.0kg (based on long flare unit) Ex de: 5.8kg (based on long flare unit) Sensitivity (1W, 1m): 110dB* (3dB) Max at full power (25W, 1m): 124dB* (3dB) 100V, 70V, 25V 25W: 25.0, 12.5, 6.0, 4.0, 2.0, 1.0* 15W: 15.0, 7.5, 5.0, 4.0, 2.0, 0.8* 8W: 8.0, 4.0, 2.0, 1.5, 0.7, 0.4* 8* Tag & duty labels, swivel bracket, DC blocking capacitor, flare length, flare colour 280mm 208mm FOR SHORT FLARE O143mm O200mm DB20C Ex de Loudspeaker Certification Area classification ATEX/IEC classification Approvals Operating temperature Ingress protection Material Entries Weight Output Transformer Wattage & transformer tappings Low impedance Options ATEX, IECEx, TR CU Zone 1, 2, 21, 22, weatherproof Ex II 2GD Ex de IIC T4/T5, Ex tD A21 T100C/T115C/T130C DNV -50C to +70C IP66 & IP67 Body: corrosion free GRP Flare: U.V. stable ABS 2 x M20 & 1 x blank plug M20 1.5kg Sensitivity (1W, 1m): 100dB (3dB) Max at full power (4W, 1m): 106dB (3dB) 100V 4W: 4.0, 2.0, 1.0, 0.75, 0.38, 0.2* 134mm O200mm CUTOUT O175mm 8* Tag & duty labels, Earth continuity, loop in/out terminals *Model dependent 42 EATON signalling and alarms product overview Hazardous area loudspeakers DB20 Ex de Loudspeaker Certification Area classification ATEX/IEC classification Approvals Operating temperature Ingress protection Material Entries Weight Sound output Transformer Wattage & transformer tappings Low impedance Options DB10 ATEX, IECEx, TR CU, CCOE Zone 1, 2, 21, 22*, weatherproof Ex II 2G, Ex de IIB T3/T4, Ex II 2GD 103 3 137mm Ex de IIC T4/T5, Ex tD A21 T130C/T115C/T100C Russian fire approval -50C to +70C IP66 & IP67 Body: corrosion free GRP. Flare: U.V. stable ABS 2 x M20 & 1 x blank plug M20 1.5kg Sensitivity (1W, 1m): 100dB* (3dB) Max at full power (8W, 1m): 112dB* (3dB) 100V ALL DIMENSIONS ARE IN mm 8W: 8.0, 4.0, 2.0, 1.5, 0.7, 0.4* 4W: 4.0, 2.0, 1.0, 0.75, 0.38, 0.2* 8* Tag & duty labels, Earth continuity, loop in/out terminals, colour O124mm Ex de Loudspeaker Certification Area classification ATEX/IEC classification Approvals Operating temperature Ingress protection Material Entries Weight Sound output Transformer Wattage & transformer tappings Low impendance Options ATEX, IECEx, TR CU, CQST, INMETRO, CCOE Zone 1, 2, 21, 22*, weatherproof Ex II 2G, Ex de IIB + H2 T4/T5/T6 Gb Ex II 2G, Ex de IIC T4/T5/T6 Gb Russian fire approval, DNV -50C to +65C* IP66 & IP67 Corrosion free GRP Up to 2 x M20 Short flare: 3.1kg. Long flare: 3.5kg Sensitivity (1W, 1m): 105dB* (3dB) Max at full power (15W, 1m): 115dB* (3dB) 100V 8W: 8.0, 4.0, 2.0, 1.0, 0.5, 0.25* 15W: 15.0, 7.5, 3.75, 2.5, 1.25, 0.75* 8* Tag & duty labels, Earth continuity, colour 245mm O126mm O163mm 20/15W version O130mm 157mm 8W version DB16 Ex de Loudspeaker Certification Area classification ATEX/IEC classification UL/NEC classification Approvals Certified temperature Ingress protection Material Entries Weight Output Transformer Wattage & transformer tappings Low impedance Options ATEX, IECEx, cULus, TR CU, CCOE Zone 1, 2, 21, 22*, weatherproof Ex II 2G, Ex de IIB T3 Gb Ex de IIC T3 Gb, Ex tb IIIC T110C Db Class I, Div. 2, Groups A, B, C, D* Russian fire approval, DNV -50C to +65C* IP66 & IP67 Corrosion free GRP Up to 2 x M20, M25, 1/2" NPT or 3/4" NPT* 5.5kg Sensitivity (1W, 1m): 110dB* (3dB) Max at full power (30W, 1m): 122dB* (3dB) 100V 25W: 25.0 ,12.5, 6.0, 4.0, 2.0, 1.0* 30W: 30.0, 25.0, 12.0, 6.0, 4.0, 2.0* 8* Tag & duty labels, Earth continuity, Earth stud, colour 354.5mm O262mm *Model dependent EATON signalling and alarms product overview 43 Industrial loudspeakers IMCOS 5242 IMCOS 5253 Page 45 IMCOS 6811 IMCOS 6801 Page 45 IMCOS 6899 Page 46 Page 45 DB14 Page 46 Page 46 Eaton's range of safe area loudspeakers are manufactured from materials including steel, aluminium and plastic. They also include a variety of mounting options, suitable for multiple applications. 44 EATON signalling and alarms product overview Industrial loudspeakers IMCOS 5242 Industrial loudspeaker Area classification Approvals Operating temperature Ingress protection Material Entries Weight Sound output Transformer Wattage & transformer tappings Industrial ABS, BV, DNV, GL, LR, RINA, Chinese classification societies -25C to +90C IP22 Aluminium Prewired cable 1.5kg Sensitivity (1W, 1m): 97dB (3dB) 100V 6W: 6.0, 3.0, 2.0, 1.5, 0.8, 0.5 157mm 175mm IMCOS 5253 Weatherproof loudspeaker Area classification Approvals Operating temperature Ingress protection Material Entries Weight Sound output Transformer Wattage & transformer tappings Low impedance Weatherproof ABS, BV, DNV, GL, LR, RINA, Chinese classification societies -25C to +90C IP56 Polycarbonate 2 x PG13 0.8kg* Sensitivity (1W, 1m): 88dB (3dB) 100V 10W: 10.0, 5.0, 3.5, 2.5, 1.5, 0.8 206mm 104mm 8 IMCOS 6801 Industrial loudspeaker Area classification Approvals Operating temperature Ingress protection Material Entries Weight Sound output Transformer Wattage & transformer tappings Low impedance Industrial ABS, BV, DNV, GL, LR, RINA, Chinese classification societies -25C to +70C IP22 Alumnium/steel* 2 x M20 1.0kg Sensitivity (1W, 1m): 92dB (3dB) 100V 6W: 6.0, 3.0, 2.0, 1.5, 0.8, 0.5 O174 mm 8 *Model dependent EATON signalling and alarms product overview 45 Industrial loudspeakers IMCOS 6811 Weatherproof loudspeaker Area classification Approvals Operating temperature Ingress protection Material Entries Weight Sound output Transformer Wattage & transformer tappings Low impedance Weatherproof ABS, BV, DNV, GL, LR, RINA, Chinese classification societies -50C to +90C IP66 Plastic 2 x PG16 1.3kg Max at full power (30W, 1m): 119dB (3dB) 100V 30W: 30.0, 15.0, 10.0, 5.0, 2.5, 1.5 197mm 116mm 8 IMCOS 6899 Weatherproof loudspeaker Area classification Approvals Operating temperature Ingress protection Material Entries Weight Sound output Transformer Wattage & transformer tappings Weatherproof ABS, BV, DNV, GL, LR, RINA, Chinese classification societies -25C to +90C IP55 ABS Prewired cable 0.35kg Max at full power (1.5W, 1m): 92dB (3dB) 100V 1.5W 57mm 69mm 102mm 34mm Weatherproof loudspeaker Transformer Wattage & transformer tappings Low impedance Options Weatherproof -55C to +70C* IP66 & IP67 Corrosion free GRP 2 x M20 2.6kg Sensitivity (1W, 1m): 107dB (3dB) Max at full power (15W, 1m): 117dB (3dB) 100V 15W: 15.0, 7.5, 5.0, 4.0, 2.0, 0.8* 8* Tag & duty labels, colour *Model dependent 46 EATON signalling and alarms product overview 34mm 57mm DB14 Area classification Operating temperature Ingress protection Material Entries Weight Output 69mm 102mm Hazardous Area Communications MEDC Oxalis IMCOSTM HERNISTM SonixTM Yuhua FHF Hazardous Area Communications is a comprehensive product offering for potentially explosive atmospheres, bringing together a range of specialist systems and solutions for the fire & gas, telecoms and CCTV markets. Our solution names of MEDC, Oxalis, IMCOSTM, HERNISTM, SonixTM, Yuhua and FHF offer a specialised team of highly qualified staff to ensure all aspects of engineering, design and configuration with your project are fulfilled - from initial stages of concept through to commissioning. With experience dating back over 100 years, we work together with one idea in mind; to make working environments a safer, more reliable place to operate. EATON signalling and alarms product overview 47 Hazardous area status lights and combination units CU1 DB3B/XB15 Page 49 SM87SL DB3B/XB11 Page 49 XB11SL Page 51 DB3B/SM87HXB Page 50 SL5 Page 52 Page 50 SL15 Page 52 DB1/SM87HXB Page 51 XB12SL Page 53 Page 53 Eaton's range of audible and visual combination units are designed for the purpose of alerting audio and visual awareness to an emergency situation. The combination units are built for use in harsh environmental conditions found offshore and onshore in the oil, gas and petrochemical industries. As well as the products found in this section, combination units can be built to order from various sounders and beacons found in this catalogue. Please contact Eaton for details. Eaton also offer a range of Status Lights designed for potentially explosive atmospheres and harsh environmental conditions. Status lights are commonly found in oil, gas, petrochemical and other hazardous areas where multi-coloured lamp combinations are used to identify the safety status of specific zones. Customers can choose from a range of materials, including stainless steel and GRP and a selection of light sources including LED. 48 EATON signalling and alarms product overview Hazardous area status lights and combination units CU1 Ex de sounder / 5 & 10 joule beacon combination units Certification Area classification ATEX/IEC classification Approvals Certified temperature Ingress protection Material Entries Weight Voltage Sound output Tones Stages Light source Options ATEX, IECEx, TR CU, INMETRO, CCOE Zone 1, 2, weatherproof Ex II 2G, Ex de IIB T4 Gb Russian fire approval, ABS -50C to +70C* IP66 & IP67 Corrosion free GRP Up to 2 x M20, M25, 1/2" NPT or 3/4" NPT 6.5kg 24-48Vdc, 110-254Vac Max: 116dB*, 1m (3dB) 27 2* Xenon Tube energy, flash rate, lens colour, labels, telephone initiate, relay initiate, independent operation, Earth continuity, special tones, EOL resistor, body colour 320mm 206.5mm O124mm DB3B/XB15 Ex d sounder / 5, 10 & 15 joule beacon combination units Certification Area classification ATEX/IEC classification UL/NEC classification Approvals Certified temperature Ingress protection Materials Entries Voltage Sound output Tones Stages Light source Options ATEX, IECEx, cULus, TR CU, CQST, INMETRO, CCOE Zone 1, 2, 21, 22, weatherproof Ex II 2GD, Ex d IIC T4/T5/T6 Gb Ex tb IIIC T135C/T100C/T85C Db* Class I, Div. 2, Groups A, B, C, D Class II, Div. 2, Groups F, G Russian fire approval -55C to +70C IP66 & IP67, NEMA 4X & 6 Body: corrosion free GRP. Flare: thermoplastic Up to 2 x M20, M25, 1/2" NPT or 3/4" NPT customer entries. Note: Customer entries are in the beacon 24-48Vdc, 110-254Vac Max: 122dB*, 1m (3dB) 28 3 Xenon Tube energy, body, lens & flare colour, lens guard, flash rate, earth continuity, relay & tel. initiate, flare type, labels 220mm 490mm *Model dependent EATON signalling and alarms product overview 49 Hazardous area status lights and combination units DB3B/XB11 Ex d sounder / 5 joule beacon combination unit Certification Area certification ATEX/IEC classification UL/NEC classification Approvals Certified temperature Ingress protection Materials Entries Voltage Sound output Tones Stages Light source Options ATEX, IECEx, cULus, TR CU, CQST, INMETRO, CCOE Zone 1, 2, 21, 22, weatherproof Ex II 2GD, Ex d IIB T4/T5/T6 Gb Ex tb IIIC T135C/T100C/T85C Db* Class I, Div. 2, Groups C, D Russian fire approval -55C to +70C IP66 & IP67, NEMA 4X & 6 Body: corrosion free GRP. Flare: thermoplastic 1 x M20 or 1/2" NPT customer entry Note: Customer entries are in the beacon 24-48Vdc, 110-240Vac Max: 122dB*, 1m (3dB) 28 3 Xenon Body, lens & flare colour, lens guard, flash rate, earth continuity, tel. initiate, flare type, labels 220mm 490mm DB3B/SM87HXB Ex d sounder / 5 joule beacon combination unit Certification Area classification ATEX/IEC classification UL/NEC classification Approvals Certified temperature Ingress protection Materials Entries Voltage Sound output Tones Stages Light source Options ATEX, IECEx, cULus, TR CU, CQST, INMETRO, CCOE Zone 1, 2, 21, 22, weatherproof Ex II 2GD, Ex d IIC T4/T5/T6 Gb Ex tb IIIC T135C/T100C/T85C Db* Class I, Div. 1, Groups C, D SIL1, Russian fire approval -55C to +70C IP66 & IP67, NEMA 4X & 6 Beacon body: stainless steel or alloy Sounder body: corrosion free GRP Flare: thermoplastic Up to 3 x M20 or 1/2" NPT customer entries Note: Customer entries are in the beacon 24-48Vdc, 110-254Vac Max: 122dB*, 1m (3dB) 28 3 Xenon Body, lens & flare colour, lens guard, flash rate, earth continuity, tel. initiate, flare type, labels 220mm 420mm *Model dependent 50 EATON Signalling and alarms Product overview Hazardous area status lights and combination units DB1P/SM87HXB Ex d sounder / 5 joule beacon combination unit Certification Area classification ATEX/IEC classification UL/NEC classification Approvals Certified temperature Ingress protection Materials Entries Voltage Sound output Tones Stages Light source Options ATEX, IECEx, cULus, TR CU, CCOE Zone 1, 2, weatherproof Ex II 2G, Ex d IIB T5/T6 Class I, Div. 1, Groups C, D SIL1 -25C to +70C IP66, NEMA 4X Stainless steel or alloy Up to 3 x M20 or 1/2" NPT customer entries Note: Customer entries are in the beacon 24-48Vdc, 110-240Vac Max: 110dB*, 1m (3dB) 27 2 Xenon Body & lens colour, lens guard, flash rate, earth continuity, tel initiate, number of sounder stages, labels 228mm 351mm SM87SL 5 joule Ex d xenon and LED status light Certification Area classification ATEX/IEC classification UL/NEC classification 3 way shown Approvals Certified temperature Ingress protection Material Entries Weight Voltage Light source Number of ways Options ATEX, IECEx, cULus*, CSA*, TR CU, CQST*, INMETRO Zone 1, 2, 21, 22, weatherproof Xenon: Ex II 2GD, Ex d IIC T5/T6 Gb Ex tb IIIC T95C/T80C/T65C Db Fluorescent: Ex II 2GD, Ex d IIC T6 Gb Ex tb IIIC T85C Db Filament: Ex II 2GD, Ex d IIC T3/T4/T5/T6 Gb Ex tb IIIC T155C/T130C/100C/ T85C Db LED: Ex II 2GD, Ex d IIC T6 Gb Ex tb IIIC T70C Db Class I, Div. 1, Groups C, D Class I, Zone 1, Aex d IIB, Exd IIB Russian fire approval -55C to +70C* IP66 & IP67, NEMA 4X & 6 Stainless steel or alloy Up to 3 x M20, M25, 1/2" NPT or 3/4" NPT See datasheet 24-48Vdc, 110-254Vac* Xenon, filament, fluorescent, LED Up to 5 Lens colour, LED colour, lens guard, tag/duty label, telephone initiate, relay initiate, EOL resistor, body colour (A) 175 3 (S) 168 3 170mm 375mm 3 way shown *Model dependent EATON Signalling and alarms Product overview 51 Hazardous area status lights and combination units XB11SL 5 joule Ex d status light Certification Area classification ATEX/IEC classification UL/NEC classification 2 way shown Approvals Certified temperature Operating temperature Ingress protection Material Entries Weight Voltage Light source Number of ways Options ATEX, IECEx, cULus, TR CU, CQST, INMETRO Zone 1, 2, 21, 22, weatherproof Ex II 2GD, Ex d IIB T4/T5/T6 Gb Ex tb IIIC T110C/T85C/T70C Db Class I, Div. 2, Groups C, D Class I, Zone 1, AEx d IIB, Ex d IIB Russian fire approval, CSFM -55C to +70C -55C to +70C IP66 & IP67 Corrosion free GRP 1 x M20 or 1/2" NPT See datasheet* 24-48Vdc, 110-240Vac Xenon, filament, fluorescent Up to 5 Flash rate, lamp wattage, lens colour, lens guard, earth continuity, tag/duty label, telephone initiate, body colour 2 way shown Fluorescent operating temperature = -20C SL5 Ex e xenon, filament and LED status light Certification Area classification ATEX/IEC classification Certified temperature 4 way shown Ingress protection Material Entries Weight Voltage Light source Number of ways Options ATEX, IECEx, CQST Zone 1, 2, weatherproof Xenon: Ex II 2G, Ex e mb IIC T4 Gb Filament: Ex II 2G, Ex e IIC T3 Gb LED: Ex II 2G, Ex e mb IIC T4 Gb Xenon: -40C to +55C Filament: -40C to +55C LED: -40C to +45C IP66 & IP67 Corrosion free GRP Up to 2 x M16, M20 or 1 x M25, M32 1.2kg per way 12-48Vdc* Xenon, filament, LED Up to 5 Light source, tag & duty labels, body colour 3 way shown *Model dependent 52 EATON signalling and alarms product overview Hazardous area status lights and combination units SL15 5, 10 & 15 joule Ex d xenon and LED status light Certification Area classification ATEX/IEC classification UL/NEC classification Certified temperature Ingress protection Material Entries Weight Voltage Light source Number of ways Options ATEX, IECEx, cULus Zone 1, 2, 21, 22, weatherproof Xenon: Ex II 2GD, Ex db IIC T4/T5/T6 Gb Ex tb IIIC T135C/T100C/T85C Db Filament: Ex II 2GD, Ex db IIC T3/T4 Gb Ex tb IIIC T200C/T135C Db LED: Ex II 2GD, Ex db IIC T5/T6 Gb Ex tb IIIC T100C/T85C Db Class II, Div. 2, Groups F, G -55C to +70C IP66 & IP67, NEMA 4X & 6 Corrosion free GRP Up to 2 x M20, M25, 1/2" NPT or 3/4" NPT See datasheet 24-48Vdc, 110-254Vac* Xenon, filament, LED Up to 4 Flash rate (xenon & LED), light source, tube energy (xenon), lens guard, tag & duty label, body colour 208mm 250m 197mm 197mm XB12SL 21 joule xenon and steady Ex d status light Certification Area classification ATEX/IEC classification UL/NEC classification Approvals Certified temperature Ingress protection Material Entries Weight Voltage Light source Number of ways Options ATEX, IECEx, cULus, TR CU, INMETRO Zone 1, 2, weatherproof Xenon: Ex II 2G, Ex d IIB T4/T5/T6 Gb Filament: Ex II 2G, Ex d IIB T3/T4/T5 Gb Fluorescent: Ex II 2G, Ex d IIB T4/T5/T6 Gb Rotating: Ex II 2G, Ex d IIB T3/T4 Gb Class I, Div. 2, Groups C, D Class I, Zone 1, AEx d IIB, Ex d IIB Russian fire approval, CSFM Xenon: -55C to +70C Filament: -55C to +55C Fluorescent: -20C to +70C IP66 & IP67, NEMA 4X & 6 Corrosion free GRP 1 x M20 or 1/2" NPT See datasheet 24Vdc, 110-240Vac Xenon, filament, fluorescent, rotating tungsten halogen Up to 5 Flash rate, lamp wattage, lens colour, lens guard, earth continuity, tag/duty label, telephone initiate, body colour *Model dependent EATON signalling and alarms product overview 53 Industrial status lights and combination units DB12/XB13 DB15/XB13 Page 55 HPL HPLB Page 55 SAM Page 56 54 AXL04 EATON Signalling and alarms Product overview AXL05 Page 55 SL 4 Page 57 AXL08 Page 56 SL 7 Page 57 Page 57 Page 56 Industrial status lights and combination units DB12/XB13 Weatherproof sounder / 10 joule beacon combination unit Area classification Operating temperature Ingress protection Materials Entries Voltage Sound output Tones Stages Light source Options Weatherproof -40C to +70C IP66 & IP67 Body: corrosion free GRP. Lens: polycarbonate Up to 2 x M20 customer entries Note: Customer entries are in the beacon 12-24Vdc, 115-230Vac Max: 110dB, 1m (3dB) 27 2* Xenon Body & lens colour, lens guard, telephone & relay initiate, single & dual flash mode, tag & duty labels 200mm 300mm DB15/XB13 Weatherproof sounder / 10 joule beacon combination unit Area classification Operating temperature Ingress protection Materials Entries 220mm 420mm Voltage Sound output Tones Stages Light source Options Weatherproof -40C to +70C IP66 & IP67 Body: corrosion free GRP. Lens: polycarbonate Up to 2 x M20 customer entries Note: Customer entries are in the beacon 12-48Vdc, 115-230Vac Max: 117dB, 1m (3dB) 27 2* Xenon Body & lens colour, lens guard, telephone & relay initiate, single & dual flash mode, tag & duty labels AXL04 Weatherproof sounder / 2 joule beacon combination unit Weatherproof -25C to +70C IP66 Impact resistant ABS 0.5kg 9-60Vdc, 115-230Vac Max: 105dB, 1m (3dB) 32 2 Xenon Lens colour 136mm 137mm Area classification Operating temperature Ingress protection Materials Weight Voltage Sound output Tones Stages Light source Options 119mm *Model dependent EATON Signalling and alarms Product overview 55 Industrial status lights and combination units AXL05 Weatherproof sounder / 2.5 joule beacon combination unit Weatherproof -25C to +70C IP66 Impact resistant ABS 0.8kg 9-60Vdc, 115-230Vac Max: 112dB, 1m (3dB) 32 2 Xenon Lens colour 165mm 173mm Area classification Operating temperature Ingress protection Materials Weight Voltage Sound output Tones Stages Light source Options AXL08 Weatherproof sounder / 2 & 3.6 joule beacon combination units Weatherproof -25C to +70C IP66 Impact resistant ABS 1.8kg - 2.8kg* 18-30Vdc, 230Vac Max: 120dB, 1m (3dB) 42 3 Xenon Lens colour 168mm 212mm Area classification Operating temperature Ingress protection Materials Weight Voltage Sound output Tones Stages Light source Options HPL/HPLB Weatherproof mini hooter with warning light Area classification Operating temperature Ingress protection Material Weight Voltage Sound output Light source Options Weatherproof -20C to +50C IP43 Impact resistant ABS 0.185Kg 12-24Vdc, 230Vac Max: 92dB, 1m (3dB) HPL: 7W Filament. HPLB: 1 joule xenon Light source, lens colour 209mm 80mm *Model dependent 56 EATON signalling and alarms product overview 64mm Industrial status lights and combination units 265 185 147 21,6644 mm 21,5525 mm 26,3461 mm 265 SAM weatherproof Traffic Light LD 25,8624 mm 85 147 265 14,8670 mm 25,8624 mm Weatherproof traffic light Area classification Operating temperature Ingress protection Material Entries Weight Voltage Light source Number of ways Options Weatherproof -20C to +60C IP54 UV Resistant plastic Via the bracket 2.0kg - 4.7kg* 24Vdc, 230Vac Filament, LED Up to 3 Light source, Lens colours, number of ways 77,0000 mm 675 51,5218 mm 265 26,1331 mm 530 SAM 85 15,3316 mm 790mm 935mm 78,7654 mm 265mm 26,2476 mm 290mm 37,7681 mm 19,6779 mm 135mm SL 4 Weatherproof stack light Weatherproof -30C to +60C IP66 Polycarbonate Various depending on base Various depending on configuration 18-250*Vdc, 110-250*Vac LED Up to 5 Lens colour, flashing or continuous, mounting base, light source, sounder, SmartWire-DT 340 Area classification Operating temperature Ingress protection Material Entries Weight Voltage Light source Number of ways Options O72 SL 7 Weatherproof stack light Weatherproof -30C to +60C IP66 Polycarbonate Various depending on base Various depending on configuration 18-250*Vdc, 110-250*Vac LED Up to 5 Lens colour, flashing or continuous, mounting base, light source, sounder, SmartWire-DT 373 Area classification Operating temperature Ingress protection Material Entries Weight Voltage Light source Number of ways Options O72 *Model dependent EATON signalling and alarms product overview 57 Explosion proof telephones and accessories ExResistTel ExResistTel MB Page 60 FernTel IP Z2 ExResistTel IP2 Page 60 Ex-Howl-Call telephone Page 61 Secondary telephone Telephone call relay bell mTAR Page 62 Page 60 ResistTel accessories Page 61 FernTel 3 Zone 2 Page 61 TWIN-EExII Page 62 Page 62 Page 62 Eaton offers a range of analogue and VOIP telephones from Funke+Huster Fernsig (FHF). Eaton provides a wide range of Hazardous Area and Industrial Telephones tested in harsh environments such as chemical plants, off-shore platforms and remote gas generating stations. The hazardous area phones are offered with global ATEX, IECEx, INMETRO, UL and TR CU approvals. 58 EATON signalling and alarms product overview FHF ExResistTel IP2 Proven technology from Eaton ensures the FHF ExResistTel IP2 is the ideal unit for all kinds of adverse weather conditions at a wide variety of diverse facilities. The housing is made of impact and shock resistant fiberglass-reinforced polyester. Its robust design is perfect to meet the latest requirements demanded of VoIP telephones for use in hazardous areas. The ExResistTel IP2 allows efficient operation by providing especially convenient features and benefits such as an illuminated heated display, a V4A keypad suitable for use with industrial gloves, and handsfree communication. It also supports all features of the H.323 SIP(SIP over UDP), TSIP(SIP over TCP) and SIPS(SIP over TLS). A headset, available as accessory equipment, can be easily connected to the telephone. ** ATEX and IECEx certified ** Ringing volume of 95dB(A) ** IP66 protection ** Operating temperature -40C to +60C ** Illuminated, heated LCD display ** Intelligent, user friendly menu structure ** Handsfree communication ** Standard H.323, SIP, TSIP, SIPS protocols ** Power supply: Power over Ethernet or external supply ** Simply connected to a single 10/100 BASE T Ethernet LAN, RJ45 EATON signalling and alarms product overview 59 Explosion proof telephones and accessories ExResistTel Explosion proof robust telephone Certification ATEX/IEC classification Certified temperature Ingress protection Material Weight Options ATEX, IECEx, INMETRO, TR CU, UL Ex II 2G, Ex e mb [ib] IIC T6/T5 Gb Ex II 2D, Ex tb [ib] IIIC T80C/T100C Db -25C to +60C T5 -25C to +40C T6 IP66 Corrosion-free GRP 5.5kg Body colour, certification, keypad & display, accessories; headset, earpiece, TWIN sounder/beacon, secondary sounder 254mm 227mm ExResistTel MB Explosion proof robust telephone Certification ATEX/IEC classification Certified temperature Ingress protection Material Weight Options ATEX, IECEx, Ex II 2G, Ex e mb [ib] IIC T6/T5 Gb Ex II 2D, Ex tb [ib] IIIC T80C/T100C Db -25C to +60C (T5) -25C to +40C (T6) IP66 Corrosion-free GRP 5.5kg Accessories, headset, earpiece, ExTWIN sounder/ beacon, secondary ex sounder, certification 227mm 264mm ExResistTel IP2 Explosion proof IP telephone Certification ATEX/IEC classification Certified temperature Ingress protection Material Weight Protocol Power supply Options ATEX, IECEx, INMETRO, TR CU II 2G Ex e ib [ib] mb IIC T4 Gb, III 2D Ex ib [ib] tb IIIC T 135 C Db -40C to +60C IP66 Corrosion-free GRP 5kg approx H.323, SIP, TSIP, SIPS Power over Ethernet Certification, headset 254mm 227mm 60 EATON signalling and alarms product overview Explosion proof telephones and accessories FernTel 3 Zone 2 Explosion proof wall and desk telephone Certification ATEX/IEC classification Certified temperature Display: Ingress protection Material Entries Weight Options ATEX, IECEx, INMETRO Ex II 3G, Ex nA ic IIC T5 Gc Ex II 3D, Ex tc ic IIIC T80C Dc -20C to +55C -10C to +55C IP65 Polycarbonate Up to 2 x M20 2.3 Kg Body colour, spiral/armed cord, with/without display and without keypad, stabilizer bracket 191mm 293mm FernTel IP Z2 Explosion proof wall and desk IP telephone Certification ATEX/IEC classification Certified temperature Ingress protection Material Weight Protocol Power supply Options ATEX, IECEx, INMETRO, UL Ex II 3G, Ex nA ic IIC T5 Gc Ex II 3D, Ex tc ic IIIC T80C Dc -20C to +55C IP65 Polycarbonate 2.34kg approx H.323, SIP, TSIP, SIPS Power over Ethernet Body colour, certification, spiral cord/armoured cord, stabiliser bracket 191mm 293mm Ex-howl-call telephone Sound powered telephone for use in Zone 1 Certification ATEX/IEC classification Certified temperature Ingress protection Material Weight Options ATEX Ex II 1G, Ex ia IIC T6 Ga Ex I M1, Ex ia I Ma -20C to +40C IP54 Plastic approx. 1,3 Kg Accessories; snap-in plug, coupling socket, wall socket, prick pincers, flat-band cable 370mm 70mm EATON signalling and alarms product overview 128mm 61 Explosion proof telephones and accessories Ex-ResistTel accessories Certification ATEX/IEC classification Certified temperature Ingress protection Material Weight ATEX, TR CU II 2 G EEx em[ib] IIC T5/T6 -25C to +60C* Secondary receiver set: IP54 Headset: IP20 GRP Headset approx. 1 kg Ex ResistTel with Headset Ex ResistTel with second receiver TWIN-EExII Ex em sounder / 0.9 joule beacon combination unit Certification Area classification ATEX/IEC classification Certified temperature Ingress protection Material Entries Weight Voltage Sound output Tones Light source Options ATEX Zone 1, 2 Ex II 2G, Ex e mb [ib] T6/T5/T4 Gb -20C to +60C* IP66 Housing: Aluminium die cast, polycarbonate 2 x M20 1.5kg 230Vac Max: 90dB, 1m (3dB) 8 Xenon Lens colour 150mm 130mm Explosion proof secondary telephone bell For use as a secondary ringer Certification ATEX/IEC classification Certified temperature Ingress protection Material Weight Options ATEX, TR CU, INMETRO II 2G Ex e ib mb IIC T6 -20C to +40C IP66 Aluminium 0.5kg approx Certification 150mm 137mm 130mm *Model dependent 62 EATON signalling and alarms product overview 117 Explosion proof telephones and accessories Explosion proof telephone call relay mTAR Connects signalling devices with telephones Certification ATEX/IEC classification Certified temperature Ingress protection Material Weight Voltage Options ATEX, IECEx, INMETRO Ex II 2G, Ex e ib mb IIC T4 Gb Ex II 2D, Ex tb IIIC T135C Db -40C to +70C IP66 GRP 0.5kg approx 230VAC 5A (max. 100W) Call break bridging 190mm 114mm 75mm 210mm EATON signalling and alarms product overview 63 Industrial telephones and accessories ResistTel ResistTel MB Page 65 FernTel IP ResistTel IP Page 65 VoIP InduTel Page 66 IntellyCom station Protection hoods Page 65 InduTel Page 66 TAR 21 Call relay Page 67 FernTel WP Twin LED FernTel W & W ZB Page 66 AWS signalling Page 67 Page 67 Secondary telephone bell Page 68 64 EATON signalling and alarms product overview Page 68 Page 66 Page 68 Page 67 Protection housing Page 68 Industrial telephones and accessories ResistTel Weatherproof robust telephone Certification Operating temperature Ingress protection Material Weight Options Weatherproof -25C to +60C T5 IP66 Corrosion-free GRP 5.5kg Body colour, keypad & display, accessories; headset, earpiece, loudspeaker set, TWIN sounder/beacon, protection hood, secondary sounder 254mm 227mm ResistTel MB Weatherproof robust telephone Certification Operating temperature Ingress protection Material Weight Options Weatherproof -25C to +60C IP66 Corrosion-free GRP 5.5kg Accessories 254mm 16 11 133 227mm Weatherproof IP telephone Certification Operating temperature Ingress protection Material Weight Protocol Power supply Options Weatherproof -40C to +70C IP66 Corrosion-free GRP 5kg H.323, SIP, TSIP, SIPS Power over Ethernet Body colour, spiral cord/armoured cord, stabiliser bracket, relay, 2nd Lan ~ 263 ~ 133 ResistTel IP 254mm 16 11 227mm EATON signalling and alarms product overview 65 Industrial telephones and accessories FernTel Weatherproof wall and desk telephone Certification Operating temperature Display: Ingress protection Material Entries Weight Options Weatherproof -20C to +55C -10C to +55C IP65 Polycarbonate Up to2 x M20 and 2 x M25 2.3 Kg Body colour, spiral cord/armoured cord, stabiliser bracket 191mm 293mm FernTel IP Weatherproof wall and desk IP telephone Certification Operating temperature Ingress protection Material Weight Protocol Power supply Options Weatherproof -20C to +60C IP65 Polycarbonate 2.34kg approx H.323, SIP, TSIP, SIPS Power over Ethernet Body colour, spiral cord/armoured cord, stabiliser bracket 191mm 293mm VoIP InduTel wall telephone IP telephone with protection door Area classification Operating temperature Ingress protection Material Weight Protocol Power supply Options Weatherproof -40C to +55C IP66 Polycarbonate 2.3kg approx SIP Power over Ethernet Housing colour 210mm 458mm Analogue InduTel wall telephone Weatherproof telephone with protection door Certification Operating temp Ingress protection Material Weight Options Weatherproof -25C to +55C IP66 Polycarbonate 2.3kg approx Keypad, transparent door, optical call indicator 210mm 458mm 66 EATON signalling and alarms product overview Industrial telephones and accessories FernTel W and FernTel W ZB Built in telephone Area classification Operating temp Ingress protection Material Options Weatherproof -25C to +60C IP65 Polycarbonate Illuminated keypad, steel armoured handset cord, sprial cord, without/without keypad 100mm 100mm 285mm 285mm IntellyCom Station Intercom station Area classification Operating temp Ingress protection Material Weight Options Weatherproof -40C to +60C IP66 Stainless steel 1.5kg approx With/without housing, one/three dialling keys 110mm 205mm TAR21 LD 60mm TAR 21 call relay Connects signalling devices with telephones Area classification Operating temp Ingress protection Material Weight Options Weatherproof -20C to +60C IP55 Aluminium 0.75kg With call break bridging 117mm 130mm AWS signalling bell Weatherproof bell with telephone relay Area classification Operating temperature Ingress protection Material Entries Weight Voltage Sound output Options Weatherproof -20C to +60C IP55 Housing: aluminium. Dome: steel 2 x M20 1.8kg - 3.3kg* 230Vac Max: 110dB, 1m (3dB)* Dome size AWS Bell 118mm 50 O1 m m 50 O2 EATON signalling and alarms product overview 366mm 67 Industrial telephones and accessories Protection housing Area classification Operating temp Material Weight dB attenuation Options Weatherproof From -50C to + 70C* Plastic, GRP, sheet steel, V4A Depends on material 16 & 26* Material, colours 500mm Protection hood and housing GRP 262 535 510 400mm Area classification Material Weight Noise insilation Options 200 420 460 Protection hoods 6, Ruckseite 600 Weatherproof GRP, DIN 5510, Class S4, Perforated plate metal, plastic, sheet steel* and stainless steel* Depends on material 25dB Material, colours, console 240mm 808mm 985mm WP Twin LED LED (Telephone) sounder / beacon combination unit Area classification Operating temperature Ingress protection Material Entries Weight Voltage Sound output Tones Light source Options Weatherproof -40C to +65C* IP66 Seawater resistant aluminium body 2 x M20 1.8kg 24Vdc, 115-230Vac Max: 102dB, 1m (3dB) 8 LED Lens colour (clear, red, yellow green, blue) 150mm 144mm 130mm 148mm Secondary telephone bell For use as a secondary ringer Operating temperature Ingress protection Material Weight -20C to +40C IP66 Aluminium 0.5kg approx 150mm 137mm 130mm *Model dependent 68 EATON signalling and alarms product overview 117 Introducing the WP Twin LED Eaton is pleased to announce the launch of the new TWIN LED audio visual signalling device using high intensity LED technology. The unit is designed to be used as a stand alone sounder beacon combination unit or in conjunction with a telephone. Designed to provide both audio and visual signalling and warning in high noise environments, the TWIN LED permits clear audio and visually signalling in industrial environments. The TWIN LED offers both improved audio performance with a higher ring volume up to 102 db(A) and greater brightness and visibility by using high power LED technology instead of Xenon flash tubes. The TWIN LED has an ingress protection of IP66 and is designed to withstand the harsh environments onshore, offshore and marine. As the mounting dimensions are unchanged from previous model, it means it is reverse compatible and can be simply used to replace and upgrade current installations. * * * * * * * High intensity LED technology Long life LED technology High output volume 102dB(A) Available with 5 different lens colours Power supply options 24 VDC, or 230 VAC (103 -253 VAC) Ingress protection IP66 Operating temperature -40C to +65C EATON signalling and alarms product overview 69 Hazardous area control and distribution HD1 SM87JB Page 71 GHG 411 81 JB10 & JB11 Page 71 GHG 411 82 Page 73 GP & JL Page 71 GHG 411 83 Page 73 GHG 74/44 Page 72 EL 101 D Page 73 Page 72 Surge arrestor DUS Page 74 Eaton offers standard and bespoke control and distribution units for harsh and hazardous areas. The control units are designed with convenient operation, safety and reliability in mind. As a leading manufacturer of hazardous area and explosion proof equipment, Eaton can provide hazardous and safe area control units in a range of dimensions to suit your required specification. 70 EATON signalling and alarms product overview Page 74 Hazardous area control and distribution HD1 Ex d, Ex e & Ex ia Heat detectors Certification Area classification ATEX/IEC classification UL/NEC classification Approvals Certified temperature Ingress protection Material Entries Voltage Options ATEX, IECEx, cULus, TR CU, CCOE Zone 1, 2, 21, 22, weatherproof Ex II 2GD, EEx d IIB+H2 T6 Ex II 2GD, Ex d IIC Ex tD A21 T85C Ex II 2G, EEx em II T6 (T4 with diodes/resistors) Ex II 1G, Ex ia IIC T6 Ga (T4 with diodes/resistors) Class I, Div. 2, Groups A, B, C, D Class I, Zone 2, Group IIC SIL2, Russian fire approval, ABS Ex d/Ex e/UL: -20C to +55C ATEX/TR CU: -20C to +125C* Ex ia: -55C to +55C IP66 & IP67, NEMA 4X & 6 Ex d: marine grade alloy Ex ia/EEx em/UL: corrosion free GRP 2 x M20 1.1kg - 2.0kg* Temperature setting ,tag & duty label, probe guard, monitoring resistors and diode, body colour 225.5mm Exd version 130mm 165mm 110mm Exia / Exem version SM87JB Ex d Junction box Certification Area classification ATEX/IEC classification Certified temperature Ingress protection Material Entries Weight Options ATEX, IECEx Zone 1, 2, 21, 22, weatherproof Ex II 2GD, Ex d IIC T4/T5/T6 Gb Ex tb IIIC T135C/T100C/T85C Db -55C to +85C IP66 & IP67 Stainless steel or alloy Up to 4 x M20, M25 3.1kg Terminals, tag/duty label, telephone initiate, relay initiate, resistors, diodes, body colour 122mm 87.52 (A) 772 (S) JB10 & JB11 Ex e Junction boxes Certification Area classification ATEX/IEC classification UL/NEC classification Certified temperature Ingress protection Material Entries Weight Options ATEX, IECEx, cULus, CCOE Zone 1, 2, weatherproof Ex II 2G, Ex e IIC T4/T5/T6 Class I, Div. 2, Groups A, B, C, D Class I, Zone 1, AEx e IIC Ex e IIC -50C to +55C IP66 & IP67, NEMA 4X & 6 Corrosion free GRP Up to 2 x M16, M20, M25, M32, 1/2" NPT or 3/4" NPT per face JB10: 1.1kg. JB11: 1.8kg Terminals, earth continuity, tag label, body colour 130mm 110mm 36.52 (ALUMIN 302 (STAINLES JB10 76.52 (A) 672 (S) 150mm 150mm JB11 *Model dependent EATON signalling and alarms product overview 71 Hazardous area control and distribution GP & JL Ex d Range of custom build control panels Certification Area classification ATEX/IEC classification Certified temperature Ingress protection Material Entries Weight Options ATEX, IECEx Zone 1, 2, 21, 22, weatherproof JL, GP1 & GP3: Ex II 2G, Exd IIB GP2 & GP4: Ex II 2GD Exd IIB Gb, Ex tb IIIC Db GP1 & GP3: -40C to +55C GP2: -40C to +55C GP4: -55C to +60C JL4: -55C to +55C GP1 & JL4: IP65 GP2, GP3 & GP4: IP66 Cast iron, stainless steel or alloy M16, M20, M25, M32, M40, M50, M63 or M75 GP1: 149kg GP2: 70kg GP3: 182kg GP4: 146kg JL4 40kg Isolators, relays, contactors, transformers, MCBs, fuses, rotary switches, printed circuit boards, invertors, PLCs, meters, indicators, pushbuttons, potentiometers, RCDs (ELCBs), timers, IS components, clients products 305mm 265mm J24 shown GHG 74/44 Ex e Control stations and terminal boxes Certification Area classification ATEX/IEC classification UL/NEC classification Certified temperature Ingress protection Material Entries Weight Options ATEX, IECEx, TR CU, cCSAus Zone 1, 2, 21, 22, weatherproof Ex II 2G, Ex e IIC T4/T5/T6 Gb / Ex e ib [ia/ib] IIC T4/T5/T6 Gb Ex II 2D, Ex tb IIIC T95C/T80C Db Class I, Div. 2, Groups A, B, C, D Class II, Div. 1, Groups E, F, G Class II, Div. 2, Groups F, G Class I, Zone 1, AEx e II, Ex e II Normal: -20C to +40C Optional: -55C to +55C IP66 Corrosion free GRP or stainless steel Multiple entries per face* See datasheet* Terminals, enclosure size *Model dependent 72 EATON signalling and alarms product overview Hazardous area control and distribution GHG 411 81 Ex e Control station Certification Area classification ATEX/IEC classification UL/NEC classification Certified temperature Ingress protection Material Entries Weight Options ATEX, IECEx, TR CU, cULus, INMETRO Zone 1, 2, 21, 22, weatherproof Ex II 2G, Ex ed ib m IIC T6 Ex II 2D, Ex tD A21 T80C Class I, Div. 2, Groups A, B, C, D Class II, Div. 1, Groups E, F, G (Canada) Class II, Div. 2, Groups F, G Class I, Zone 1, AE x e IIC T6, Ex e II T6 Normal: -20C to +40C Optional: -55C to +55C IP66 Polyamide 1 x M20 0.5kg* Pushbuttons, emergency stop, rotary switches block, potentiometer, lamps, 3 position key switch, gold contact block 85mm 115mm GHG 411 82 Ex e Control station Certification Area classification ATEX/IEC classification UL/NEC classification Certified temperature Ingress protection Material Entries Weight Options ATEX, IECEx, TR CU, cULus, INMETRO Zone 1, 2, 21, 22, weatherproof Ex e II T6, Ex e ib IIC T6 Ex ed IIC T6 or Ex ed ib IIC T6 Class I, Div. 2, Groups A, B, C, D Class II, Div. 1, Groups E, F, G (Canada) Class II, Div. 2, Groups F, G Class I, Zone 1, AE x e IIC T6, Ex e II T6 Normal: -20C to +40C Optional: -55C to +55C IP66 Polyamide 1 x M20 0.5kg* Pushbuttons, emergency stop, rotary switches block, potentiometer, lamps, 3 position key switch, gold contact block 85mm 155mm GHG 411 83 Ex e Control station Certification Area classification ATEX/IEC classification UL/NEC classification Certified temperature Ingress protection Material Entries Weight Options ATEX, IECEx, TR CU, cULus, INMETRO Zone 1, 2, 21, 22, weatherproof Ex e II T6, Ex e ib IIC T6 Ex ed IIC T6 or Ex ed ib IIC T6 Class I, Div. 2, Groups A, B, C, D Class II, Div. 1, Groups E, F, G (Canada) Class II, Div. 2, Groups F, G Class I, Zone 1, AE x e IIC T6, Ex e II T6 Normal: -20C to +40C Optional: -55C to +55C IP66 Polyamide 1 x M20 0.5kg* Pushbuttons, emergency stop, rotary switches block, potentiometer, lamps, 3 position key switch, gold contact block 85mm 195mm *Model dependent EATON signalling and alarms product overview 73 Industrial control and distribution EL 101 D Cast iron pendulum switch Area classification Operating temperature Ingress protection Material Entries Weight Voltage Weatherproof -25C to +60C IP66 Cast iron 1 x M20 10.5kg 230Vac 74mm 218mm O156mm DUS 1kV discharge surge arrester Ingress protection Material Options IP00 Housing: polyester Insulating layer: mica Spark-over voltages O52mm 32.5mm 44 *Model dependent 74 EATON signalling and alarms product overview HAC products and solutions Public Alarm & General Systems (PAGA) Closed Circuit Television Stations (CCTV) Designed to enhance modern communication philosophies, the SonixTM PA/GA system includes a highly sophisticated yet simplified architecture that removes the need for lengthy engineering cycles, bespoke and costly software, custom field engineering or expensive onsite support. We are able to offer fully compliant communications solutions to meet the most demanding applications for onshore, offshore and industrial installations. HERNISTM, Oxalis and Yuhua lead the way in developing advanced camera-based surveillance systems for marine and oil & gas installations worldwide. Our solutions contribute to increased efficiency and provide safety for people and equipment in hazardous areas and under extreme conditions. Status lights & audible and visual combination units Call points Audible alarms Manual alarm call points are designed for the purpose of raising an alarm manually once verification of a fire or emergency condition exists, by operating the push button or break glass the alarm signal can be raised. MEDC and FHF's range of audible alarms are suitable for a wide array of applications, feature a variety of tone settings, and are designed to raise the alarm in dangerous situations. Traditional bells are also available. Telephones Visual alarms Control and distribution Gitiesse and FHF supply a full range of automatic and sound powered telephones suitable for any kind of application: IP and analogue, weatherproof proof and explosion protected. Supplementary audio and optical devices are also available as an option. MEDC and FHF offer a range of beacons and combination units including flashing, steady-state indicators and rotating units. These may be used to warn of potential hazards or indicate the status of plant conditions, fire and gas alarms, evacuation alerts and many more. At MEDC we offer standard and bespoke control and distribution units for harsh and hazardous environments. As a leading manufacturer of explosion proof equipment, MEDC can provide hazardous and safe area control units in a range of dimensions to suit your required specification. For use in situations where both audible and visual awareness is required together to alert operators of a potential hazard. Customised solutions from MEDC and FHF can be designed and manufactured using our sounders and beacons to suit the specific needs of the customer. Loudspeakers The MEDC range of hazardous, heavy duty, industrial and commercial speakers are designed to meet the requirements for public address, voice alarm (evacuation) and background music. EATON signalling and alarms product overview 75 Hazardous area US products SM87PB SM87BG Page 78 LD15 PH1 Page 78 Expertline LED Page 79 XB4 Page 81 FB11 & FB12 Page 83 Page 78 SM87 HXB Page 80 XB12 PB XB11 XB16 FB15 Page 80 Page 82 Page 81 FL4 & FB4 Page 82 DB3B Page 83 Page 79 XB15 SM87LU1/LU3 DB1P Page 83 Page 79 Page 80 Page 81 BG Page 82 DB5 Page 84 Eaton offers a range of products specifically designed and certified for use in the US and Canada. This range of call points, signalling devices, telephones and control panels is certified to UL and CSA standards and is suitable for use in hazardous locations such as zone I and zone II. 76 EATON signalling and alarms product overview Page 84 dGW21/dRGW21 dGH 21 Page 84 DB3B/XB11 Page 85 DB3B/SM87HXB XB12SL Page 88 Page 89 DB1/SM87HXB Page 88 Page 90 DB3B/XB15 Page 85 SM87SL Page 87 Page 88 GHG 74/44 Page 87 Page 87 Analogue InduTel Wall telephone Page 89 GHG 411 81 Page 90 Page 86 XB11SL FernTel IP Ex ResistTel JB10 & JB11 HD1 DB16 Page 85 Page 86 Page 86 SL15 DB4B Page 90 Page 89 GHG 411 82 Page 91 GHG 411 83 Page 91 EATON signalling and alarms product overview 77 Hazardous area US products SM87PB Hazardous location push button call point Certification Area classification UL/NEC classification Approvals Certified temperature Ingress protection Material Entries Weight Switches Options cULus, ULC, CSA Hazardous locations, ordinary locations Class 1, Div. 1, Groups C, D (CSA Ex ia also includes groups A & B ) Class I, zone 1. Groups IIA, IIB SIL2, ABS -58F to +158F* NEMA 4X & 6 Stainless steel or alloy Up to 4 x 1/2" NPT or 3/4" NPT Stainless: 8.4lb. Alloy: 5.5lb 2 pole c/o (Up to 4 pole c/o available) Switch action, labels, LED, EOL and series resistors, diodes, 3 or 4 pole switches, colour 4-3/4" 4-3/4" SM87BG Hazardous location break glass call point Certification Area classification UL/NEC classification Certified temperature Ingress protection Material Entries Weight Switches Options CSA Hazardous locations, ordinary locations Class 1, Div. 1. Groups A, B, C, D -58F to +158F* NEMA 4X & 6 Stainless steel or alloy Up to 4 x 1/2" NPT or 3/4" NPT Stainless: 8.4lb. Alloy: 5.5lb 2 pole c/o (Up to 4 pole c/o available) Switch action, labels, LED, EOL and series resistors, diodes, 3 or 4 pole switches, colour 4-3/4" 4-3/4" PH1 Hazardous location pull handle call point Certified temperature Ingress protection Material Entries Weight Switches Options cULus Hazardous locations, ordinary locations Class I, Div. 1, Groups B, C, D Class I, Div. 2, Groups A, B, C, D Class II, Div. 2, Groups F, G Class III Class I, Zone 1, AEx d IIC, Ex d IIC -58F to +158F NEMA 4X & 6 Corrosion free GRP (UL Class I, Div. 1 Inner Cover: 316 stainless steel) Up to 2 x 1/2" NPT or 3/4" NPT UL Class I, Div 2/ATEX/IECEx/UW: 5.8lb UL Class I, Div. 1: 8.4lb 1 or 2 pole c/o EOL and series resistors, diodes, labels, body colour 4-5/8" 7-7/8" Certification Area classification UL/NEC classification *Model dependent 78 EATON signalling and alarms product overview Hazardous area US products PB Hazardous location push button call point Certification Area classification UL/NEC classification Approvals Certified temperature Ingress protection Material Entries Weight Switches Options cULus, CSA Hazardous locations, ordinary locations Class I, Div. 2, Groups A, B, C, D Class II, Div. 2, Groups F, G Class I, Zone 2 SIL2, ABS -58F to +131F* NEMA 4X & 6 Corrosion free GRP Up to 4 x 1/2" NPT 2.6lb 1 or 2 pole c/o Labels, LED, EOL and series resistors, diodes, Earth continuity, switch action, number of terminals, colour 4-3/4" 4-15/16" BG Hazardous location break glass call point Approvals Certified temperature Ingress protection Material Entries Weight Switches Options cULus Hazardous locations, ordinary locations Class I, Div. 2 Groups A, B, C, D Class I, Zone 2 SIL2 -13F to +131F* NEMA 4X & 6 Corrosion free GRP Up to 4 x 1/2" NPT 2.6lb 1 or 2 pole c/o Labels, switches, LED, Lift flap, EOL and series resistors, diodes, Earth continuity, plastic element, break glass hammer, number of terminals, colour 4-3/4" 4-15/6" Certification Area classification UL/NEC classification LD15 Hazardous location LED strobe 4-41/64" 9-13/32" Approvals Certified temperature Ingress protection Material Entries Weight Voltage Light source LED life Options cULus, ULC Hazardous locations, ordinary locations Class I, Div. 2, Groups A*, B*, C, D Class II, Div. 2, Groups F, G Class I, Zone 1, AEx d IIC* & IIB, Ex d IIB SIL1 (1oo1) & SIL2 (1oo2) -67F to +158F NEMA 4X & 6 Corrosion free GRP Up to 3* x 1/2" NPT or 3/4" NPT Direct: 7.7lb. Pipe: 6.8lb 12-48Vdc, 110-254Vac LED 54,000 hours Lens colour, lens guard, mounting, tag & duty label, relay initiate, body colour 9-13/32" Certification Area classification UL/NEC classification 150 3 5-29/32" Direct mount Pipe mount *Model dependent EATON signalling and alarms product overview 79 Hazardous area US products Expertline LED Certified temperature Ingress protection Material Entries Weight Voltage Light source Options cULus Hazardous locations, ordinary locations Class I, Div. 2, Groups A, B, C, D, T4 Class I, Zone 2, Groups IIA, IIB, IIC, T4 -40F to +140F NEMA 4X Polycarbonate 1x 1/2" NPT, 2x blind plug 1/2" NPT 5.5lb 24Vdc, 120-230Vac LED LED colour 12-3/8 Certification Area classification UL/NEC classification 11-3/4 Hazardous location LED strobe 7-1/4 4-11/16 2-3/8 SM87HXB Certification Area classification UL/NEC classification Approvals Certified temperature Ingress protection Material Entries Weight Voltage Light source Options cULus, CSA Hazardous locations, ordinary locations Class I, Div, 1, Groups C, D Class I, Zone 1, Aex d IIB, Exd IIB SIL2 -67F to +158F NEMA 4X & 6 Stainless steel or alloy Up to 4 x 1/2" NPT or 3/4" NPT Alloy: 4.4lb. Stainless steel: 8.4lb 24-48Vdc, 110-254Vac Xenon Lens colour, lens guard, lens guard, tag/duty label, body colour 7-1/8" 5 joule hazardous location strobe 4-3/4" XB11 Certification Area classification UL/NEC classification Approvals Certified temperature Ingress protection Material Entries Weight Voltage Light source Options cULus Hazardous locations, ordinary locations Class I, Div. 2, Groups C, D Class I, Zone 1, AEx d IIB, Ex d IIB CSFM -67F to +158F NEMA 4X & 6 Corrosion free GRP 2 x 1/2" NPT 5.5lb 24-48Vdc, 110-240Vac Xenon Flash rate, lens colour, lens guard, mounting, tag/duty label, body colour 8-3-32" 5 joule hazardous location strobe 7-7/8" *Model dependent 80 EATON signalling and alarms product overview Hazardous area US products XB15 5, 10 & 15 joule hazardous location xenon strobes 4-41/64" 9-13/32" Approvals Certified temperature Ingress protection Material Entries Weight Voltage Light source Options cULus, ULC Hazardous locations, ordinary locations Class I, Div. 2, Groups A*, B*, C, D Class II, Div. 2, Groups F, G Class I, Zone 1 AEx d IIC* & IIB, Ex d IIB SIL1, CSFM, UL Marine -67F to +158F NEMA 4X & 6 Corrosion free GRP Up to 3* x 1/2" NPT or 3/4" NPT 5.7lb - 6.6lb 24-48Vdc, 110-254Vac Xenon Tube energy, flash rate, lens colour, lens guard, mounting, tag & duty label, relay initiate, body colour 9-13/32" Certification Area classification UL/NEC classification 150 3 5-29/32" Direct mount Pipe mount XB4 Certification Area classification UL/NEC classification Certified temperature Ingress protection Material Entries Weight Voltage Light source Options cULus Hazardous locations, ordinary locations Class I, Div. 1, Groups C, D Class I, Zone 1, Groups IIB & IIA -67F to +158F NEMA 4X & 6 Stainless steel or alloy Up to 3 x 1/2" NPT or 3/4" NPT Alloy: 14.5lb - 16.7lb Stainless steel: 33.0lb - 35.0lb 24Vdc, 110-240Vac Xenon Flash rate, relay initiate, lens guard, lens colour, tag/duty label, body colour 11" 21 joule hazardous location xenon strobe 9-1/16" XB12 Certification Area classification UL/NEC classification Approvals Certified temperature Ingress protection Material Entries Weight Voltage Light source Options cULus Hazardous locations, ordinary locations Class I, Div. 2, Groups C, D Class I, Zone 1, AEx d IIB, Ex d IIB CSFM, UL Marine -67F to +158F NEMA 4X & 6 Corrosion free GRP 2 x 1/2" NPT 15.4lb 24Vdc, 110-240Vac Xenon Body & lens colour, lens guard, tag & duty labels, flash rate, mounting method 12-3/32" 21 joule hazardous location xenon strobe 11-1/32" *Model dependent EATON signalling and alarms product overview 81 Hazardous area US products XB16 Certification Area classification UL/NEC classification Approvals Certified temperature Ingress protection Material Entries Weight Voltage Light source Options cULus Hazardous locations, ordinary locations Class I, Div. 2, Groups A ,B, C, D Class II, Div. 2, Groups F, G UL1971, CSFM -67F to +158F NEMA 4X & 6 Corrosion free GRP 1 x 3/4" NPT 2.2lb 24-48Vdc, 110-254Vac Xenon Flash rate, lens colour, lens guard, tag & duty label, relay initiate, body colour 8-35/64" 10 joule hazardous location xenon strobe 4-5/8" SM87LU1/LU3 Certification Area classification UL/NEC classification Certified temperature Operating temperature Ingress protection Material Entries Weight Voltage Light source Options cULus, CSA Hazardous locations, ordinary locations Class I, Div. 1, Groups C, D Class I, Zone 1, Aex d IIB, Exd IIB -67F to +131F SM87LU1: -4F to +131F SM87LU3: -67F to +131F NEMA 4X & 6 Stainless steel or alloy SM87LU1: Up to 3 x 1/2" NPT or 3/4" NPT SM87LU3: Up to 4 x 1/2" NPT or 3/4" NPT Alloy: 5.5lb. Stainless steel: 8.3lb 24-48Vdc, 110-254Vac Filament, fluorescent Lens colour, lens guard, tag/duty labels, body colour 7-1/8" Hazardous location steady burning light 4-3/4" FL4 & FB4 Certification Area classification UL/NEC classification Certified temperature Operating temperature Ingress protection Material Entries Weight Voltage Light source Options 82 EATON signalling and alarms product overview cULus Hazardous locations, ordinary locations Class I, Div. 1, Groups C, D Class I, Zone 1, Groups IIB & IIA FL4: -4F to +131F FB4: -67F to +131F FL4: -4F to +131F FB4: -67F to +131F NEMA 4X & 6 Stainless steel or alloy Up to 3 x 1/2" NPT or 3/4" NPT Alloy: 14.3lb - 19.6lb Stainless steel: 32.8lb - 38.1lb 24-110Vdc, 110-254Vac Filament, fluorescent Lamp wattage, lens colour, lens guard, tag & duty labels, relay initiate, body colour 11" Ex d(e) steady beacons 9-1/16" Hazardous area US products FB11 & FB12 Hazardous location steady burning lights 4-3/4" 12-3/32" Certified temperature Ingress protection Material Entries Weight Voltage Light source Options cULus Hazardous locations, ordinary locations Class I, Div. 2, Groups C, D Class I, Zone 1, AEx d IIB, Ex d IIB -67F to +131F NEMA 4X and 6 Corrosion free GRP 2 x 1/2" NPT FB11: 6.2lb. FB12: 16.7lb 24-48Vdc, 110-254Vac Filament Lamp wattage, lens colour, lens guard, mounting, tag/duty label, body colour 7-1/8" Certification Area classification UL/NEC classification 11-1/32" FB15 Hazardous location steady burning light 4-41/64" 9-13/32" Approvals Certified temperature Ingress protection Material Entries Weight Voltage Light source Options cULus Hazardous locations, ordinary locations Class I, Div. 2, Groups A*, B*, C, D Class I, Zone 1 AEx d IIC* & IIB, Ex d IIB CSFM -67F to +158F NEMA 4X and 6 Corrosion free GRP Up to 3* x 1/2" NPT or 3/4" NPT Pipe: 5.7lb. Direct: 6.6lb 24-48Vdc, 110-254Vac Filament Lamp wattage, lens colour, lens guard, mounting, tag & duty label, lens colour 9-13/32" Certification Area classification UL/NEC classification 150 3 Pipe mount 5-29/32" Direct mount DB1P Hazardous location horn cULus Class I, Div 1, Groups C & D SIL1 -13F to +158F NEMA 4X Alloy Up to 3 x 1/2" NPT or 3/4" NPT 7.7lb - 12.3lb* 12-48Vdc, 110Vac Max: 100dB, 10' (3dB)* 27 2* Output level, entries, tag & duty labels, relay initiate, remote tone select, EOL resistor, colour 6-11/16" 6-19/32" Certification UL/NEC classification Approvals Certified temperature Ingress protection Material Entries Weight Voltage Sound output Tones Stages Options *Model dependent EATON signalling and alarms product overview 83 Hazardous area US products DB3B Hazardous location horn Approvals Operating temperature Ingress protection Material Entries Weight Voltage Sound output Tones Stages Options cULus Class I, Div. 2, Groups A, B, C, D Class II, Div. 2, Groups F, G SIL2, CSFM -67F to +158F NEMA 4X & 6 Body: corrosion free GRP Flare: thermoplastic Up to 2 x 1/2" NPT or M20 10lb (based on long flare unit) 12-48Vdc, 110-254Vac Max: 112dB, 10' (3dB)* 28 3 (5 voltage free) Tag & duty labels, swivel bracket, EOL resistor, Earth continuity, tone activation method, voltage free activation, flare type, custom tones, flare colour 11-7/64" 7-7/8" Certification UL/NEC classification DB5 Hazardous location horn Certification UL/NEC classification Operating temperature Ingress protection Material Entries Weight Voltage Sound output Tones Options FM, CSA Class I, Div, 1, Groups A, B, C, D -4F to +131F NEMA 4 ABS Up to 2 x M20 via knockouts 0.7lb 12-24Vdc Max: 90dB, 10' (3dB) 26 Tag label, body colour 2-1/8 1/8 1-57/641/8 O3-21/32 1/8 dGW21/dRGW21 Hazardous location bell O7-7/8 8-1/8 cULus Class I, Div. 2, Groups A, B, C, D -4F to +104F NEMA 4X Corrosion free GRP 2 x 1/2" NPT 12lb 24Vdc, 120Vac Max: 105dB, 10' (3dB) 10-5/8 Certification UL/NEC classification Operating temperature Ingress protection Material Entries Weight Voltage Sound output 4-5/16 *Model dependent 84 EATON signalling and alarms product overview Hazardous area US products dGH 21 Hazardous location hooter Certification UL/NEC classification Certified temperature Ingress protection Material Entries Weight Voltage Sound output cULus Class I, Div. 2, Groups A, B, C, D -4F to +104F NEMA 4X Corrosion free GRP 2 x 1/2" NPT 12lb 24Vdc, 240Vac Max: 105dB, 10' (3dB) 8 9/16" 10 3/4" DB4B Hazardous location loudspeaker Approvals Operating temperature Ingress protection Material Entries Weight Sound output Transformer Wattage & transformer tappings Low impedance Options cULus Class I, Div. 2, Groups A, B, C, D Class II, Div. 2, Groups F, G SIL2, CSFM -67F to +158F* NEMA 4X & 6 Body: corrosion free GRP. Flare: thermoplastic Up to 2 x 1/2" NPT or M20 11.0lb (based on long flare unit) Sensitivity (1W, 10'): 100dB* (3dB) Max at full power (25W, 10'): 114dB* (3dB) 100V, 70V, 25V 25W: 25.0, 12.5, 6.0, 4.0, 2.0, 1.0* 15W: 15.0, 7.5, 5.0, 4.0, 2.0, 0.8* 8W: 8.0, 4.0, 2.0, 1.5, 0.7, 0.4* 8* Tag & duty labels, swivel bracket, DC blocking capacitor, flare length, flare colour 11-7/64" 7-7/8" Certification UL/NEC classification DB16 Hazardous location loudspeaker Transformer Wattage & transformer tappings Low impedance Options cULus Class I, Div. 2, Groups A, B, C, D* -67F to +104F NEMA 4X & 6 Corrosion free GRP Up to 2 x 1/2" NPT or 3/4" NPT 12.0lb Sensitivity (1W, 10'): 100dB* (3dB) Max at full power (30W, 10'): 112dB* (3dB) 100V 25W: 25.0 ,12.5, 6.0, 4.0, 2.0, 1.0* 30W: 30.0, 25.0, 12.0, 6.0, 4.0, 2.0* 8* Tag & duty labels, Earth continuity, Earth stud, colour 13-61/64" 10-5/16" Certification UL/NEC classification Certified temperature Ingress protection Material Entries Weight Sound output *Model dependent EATON signalling and alarms product overview 85 Hazardous area US products DB3B/XB15 Hazardous location horn / 5, 10 & 15 joule strobe combination units Approvals Certified temperature Ingress protection Material Entries Voltage Sound output Tones Stages Light source Options cULus Hazardous locations, ordinary locations Class I, Div. 2, Groups A, B, C, D Class II, Div. 2, Groups F, G SIL1 -67F to +158F NEMA 4X & 6 Body: corrosion free GRP. Flare: thermoplastic Up to 2 x 1/2" NPT or 3/4" NPT customer entries Note: customer entries are in the strobe 24-48Vdc, 110-254Vac Max: 112dB*, 10' (3dB) 28 3 Xenon Tube energy, body, lens & flare colour, lens guard, flash rate, earth continuity, relay & tel. initiate, flare type, labels 8-11/16" 16-9/16" Certification Area classification UL/NEC classification DB3B/XB11 Hazardous location horn / 5 joule strobe combination unit Voltage Sound output Tones Stages Light source Options cULus Hazardous locations, ordinary locations Class I, Div. 2, Groups C, D -67F to +158F NEMA 4X & 6 Body: corrosion free GRP. Flare: thermoplastic 1 x 1/2" NPT customer entry Note: customer entry is in the strobe 24-48Vdc, 110-240Vac Max: 112dB*, 10' (3dB) 28 3 Xenon Body, lens & flare colour, lens guard, flash rate, earth continuity, tel. initiate, flare type, labels 8 2/3" 16 1/2" Certification Area classification UL/NEC classification Certified temperature Ingress protection Material Entries DB3B/SM87HXB Hazardous location horn / 5 joule strobe combination unit Entries Voltage Sound output Tones Stages Light source Options 86 EATON signalling and alarms product overview cULus Hazardous locations, ordinary locations Class I, Div. 1, Groups C, D SIL1 -67F to +158F NEMA 4X & 6 Strobe: stainless steel or alloy Sounder body: corrosion free GRP Flare: thermoplastic Up to 3 x 1/2" NPT customer entries Note: Customer entries are in the strobe 24-48Vdc, 110-254Vac Max: 112dB*, 10' (3dB) 28 3 Xenon Body, lens & flare colour, lens guard, flash rate, earth continuity, tel. initiate, flare type, labels 8 2/3" 16 1/2" Certification Area classification UL/NEC classification Approvals Certified temperature Ingress protection Material *Model dependent Hazardous area US products DB1/SM87HXB Hazardous location horn / 5 joule strobe combination unit Voltage Sound output Tones Stages Light source Options cULus Hazardous locations, ordinary locations Class I, Div, 1, Groups C, D SIL1 -13F to +158F NEMA 4X Stainless steel or alloy Up to 3 x 1/2" NPT customer entries Note: Customer entries are in the strobe 24-48Vdc, 110-240Vac Max: 100dB*, 10' (3dB) 27 2 Xenon Body & lens colour, lens guard, flash rate, earth continuity, tel initiate, labels 8" 13 3/4" Certification Area classification UL/NEC classification Approvals Certified temperature Ingress protection Material Entries SM87SL 5 joule hazardous location xenon and LED status light Certified temperature Ingress protection Material Entries Weight Voltage Light source No. of ways Options cULus*, CSA* Hazardous locations, ordinary locations Class I, Div. 1, Groups C, D Class I, Zone 1, Aex d IIB, Exd IIB Class I, Div 1: -13F to +131F Class I, Zone 1: -67F to +131F NEMA 4X and 6 Alloy Up to 3 x 1/2" NPT or 3/4" NPT See datasheet 24-48Vdc, 110-254Vac Xenon, filament, fluorescent Up to 5 Lens colour, lens guard, lens guard, tag/duty label, body colour 6-11/16" 19-11/16" Certification Area classification UL/NEC classification XB11SL Certification Area classification UL/NEC classification 11-1/2" Certified temperature Ingress protection Material Entries Weight Voltage Light source No. of ways Options cULus Hazardous locations, ordinary locations Class I, Div. 2, Groups C, D Class I, Zone 1, AEx d IIB, Ex d IIB -67F to +158F* NEMA 4X and 6 Corrosion free GRP 1 x 1/2" NPT See datasheet 24-48Vdc, 110-240Vac Xenon, filament, fluorescent Up to 5 Body & lens colour, tag & duty labels 19-3/4" 5 joule hazardous location status light 11-1/16" *Model dependent EATON signalling and alarms product overview 87 Hazardous area US products SL15 5, 10 and 15 joule hazardous location xenon and LED status light Certification Area classification UL/NEC classification Approvals Certified temperature Ingress protection Material Entries Weight Voltage Light source No. of ways Options cULus Hazardous locations, ordinary locations Class I, Div. 2, Groups A*, B*, C, D Class II, Div. 2, Groups F, G Class I, Zone 1, AEx d IIC* & IIB, Ex d IIB UL Marine -67F to +158F IP66 & IP67, NEMA 4X & 6 Corrosion free GRP Up to 2 x 1/2" NPT or 3/4" NPT See datasheet 24-48Vdc, 110-254Vac* Xenon, filament, LED Up to 4 Flash rate (xenon & LED), light source, tube energy (xenon), lens guard, tag & duty label, body colour Not filament 8 3/16" 9 13/16" 7 3/4" 7 3/4" XB12SL Certification Area classification UL/NEC classification No. of ways Options 11-1/2" Approvals Certified temperature Ingress protection Material Entries Weight Voltage Light source cULus Hazardous locations, ordinary locations Class I, Div. 2, Groups C, D Class I, Zone 1, AEx d IIB, Ex d IIB CSFM -67F to +158F NEMA 4x & 6 Corrosion free GRP 1 x 1/2" NPT See datasheet 24Vdc, 110-240Vac Xenon, filament, fluorescent, rotating tungsten halogen Up to 5 Flash rate, lamp wattage, lens colour, lens guard, tag/duty label, body colour 19-3/4" 21 joule xenon strobe and steady burning hazardous location status light 11-1/16" ExResistTel Hazardous and ordinary location robust telephone Ex ResistTel UL (small) ~261 UL Class 1, Div 2, Groups A, B, C, D T5 -4F to +104F NEMA 4X Corrosion-free GRP 13lbs Loudspeaker set, TWIN sounder/beacon, protection hood, secondary sounder 10-1/4" Certification UL/NEC classification Certified temperature Ingress protection Material Weight Options ~133 8-15/16" *Model dependent 88 EATON signalling and alarms product overview Hazardous area US products FernTel IP Zone 2 Hazardous and ordinary location wall and desk IP telephone Certification ATEX/IEC classification Certified temperature Ingress protection Material Weight Options UL Class 1, Division 2, Groups A, B, C, D T5 -4F to +140C NEMA 4X Polycarbonate 5.3lbs Body colour, spiral cord/armoured cord, stabiliser bracket Analogue InduTel Wall telephone Ordinary location telephone with protection door UL IT equimpment safety -40F to +141F NEMA 3R Polycarbonate 5lbs approx Keypad, transparent door, optical call indicator Body colour 8-1/4" Certification UL/NEC classification Certified temperature Ingress protection Material Weight Options Options 18" HD1 Hazardous location heat detector Approvals Certified temperature Ingress protection Material Entries Weight Options cULus Hazardous locations, ordinary locations Class I, Div. 2, Groups A, B, C, D Class I, Zone 2, Group IIC SIL2, ABS -4F to +131F NEMA 4X & 6 Corrosion free GRP 2 x 1/2" NPT (via supplied adaptors) 2.4lb Temperature setting ,tag & duty label, probe guard, monitoring resistors and diode, body colour 5-1/8" 6-1/2" 4-21/64" Certification Area classification UL/NEC classification EATON signalling and alarms product overview 89 Hazardous area US products JB10 & JB11 Hazardous location junction boxes 5-1/8" JB10 5-29/32" 5-29/32" Certified temperature Ingress protection Material Entries Weight Options cULus Hazardous locations, ordinary locations Class I, Div. 2, Groups A, B, C, D Class I, Zone 1, AEx e IIC, Ex e IIC -4F to +131F NEMA 4X & 6 Corrosion free GRP Up to 2 x 1/2" NPT or 3/4" NPT per face JB10: 2.4lb. JB11: 4.0lb Terminals, earth continuity, tag label, body colour 4-24/64" Certification Area classification UL/NEC classification JB11 GHG 74/44 Hazardous location control units and terminal boxes Certification Area classification UL/NEC classification Certified temperature Ingress protection Material Entries Weight Options cCSAus Hazardous locations, ordinary locations Class I, Div. 2, groups A, B, C, D Class II, Div. 1, Groups E, F, G Class II, Div. 2, Groups F, G Class I, Zone 1, AEx e II, Ex e II Normal: -4F to +104F Optional: -67F to +131F IP66 Corrosion free GRP or stainless steel Multiple entries per face* See datasheet* Terminals, enclosure size GHG 411 81 Hazardous location control station Certified temperature Ingress protection Material Entries Weight Options cULus Hazardous locations, ordinary locations Class I, Div. 2, Groups A, B, C, D Class II, Div. 1, Groups E, F, G (Canada) Class II, Div. 2, Groups F, G Class I, Zone 1, AE x e IIC T6, Ex e II T6 Normal: -4F to +104F Optional: -67F to +131F IP66 Polyamide 1 x 1/2" NPT 1.0lb* Pushbuttons, emergency stop, rotary switches block, potentiometer, lamps, 3 position key switch, gold contact block 3-11/32" 4-1/2" Certification Area classification UL/NEC classification *Model dependent 90 EATON signalling and alarms product overview Hazardous area US products GHG 411 82 Hazardous location control station Certified temperature Ingress protection Material Entries Weight Options cULus Hazardous locations, ordinary locations Class I, Div. 2, Groups A, B, C, D Class II, Div. 1, Groups E, F, G (Canada) Class II, Div. 2, Groups F, G Class I, Zone 1, AE x e IIC T6, Ex e II T6 Normal: -4F to +104F Optional: -67F to +131F IP66 Polyamide 1 x 1/2" NPT 1.0lb* Pushbuttons, emergency stop, rotary switches block, potentiometer, lamps, 3 position key switch, gold contact block 3-11/32" 6-9/64" Certification Area classification UL/NEC classification GHG 411 83 Hazardous location control station Certified temperature Ingress protection Material Entries Weight Options cULus Hazardous locations, ordinary locations Class I, Div. 2, Groups A, B, C, D Class II, Div. 1, Groups E, F, G (Canada) Class II, Div. 2, Groups F, G Class I, Zone 1, AE x e IIC T6, Ex e II T6 Normal: -4F to +104F Optional: -67F to +131F IP66 Polyamide 1 x 1/2" NPT 1.0lb* Pushbuttons, emergency stop, rotary switches block, potentiometer, lamps, 3 position key switch, gold contact block 3-11/32" 6-1/2" Certification Area classification UL/NEC classification *Model dependent EATON signalling and alarms product overview 91 Eaton The safety you rely on. See the complete offering at http://www.medc.com and www.fhf.de MEDC FHF Hazardous Area Communications Unit B Sutton Parkway Oddicroft Lane Sutton in Ashfield NG17 5FB United Kingdom Tel: + 44 1623 444400 Fax: + 44 1623 444531 hacmarketing@eaton.com www.crouse-hinds.com/hac Italy Office Via Al Ponte Polcevera 8/14 16161 Genova Italia Norway Office P.O. Box 791 Stoa NO-4809 Arendal Norway Germany Office FHF Funke + Huster Fernsig GmbH Gewerbeallee 15-19 45478 Mulheim a.d.Ruhr, Germany Dubai Office Techno Park, Jebel Ali (South) P.O. Box 261768 Dubai, United Arab Emirates T: +39 10 7416 801 F: +39 10 740 21 31 T: +47 37 06 37 00 F: +47 37 06 37 06 T: +49 208 82 68 0 F: +49 208 82 68 286 T: +971 4 8066100 USA Office 3413 North Sam Houston Parkway West Houston, TX 77086 USA Korea Office 7th Fl. Parkland Building 601, Eonju-ro, Gangnam-gu Seoul Korea Singapore Office No.2 Serangoon North Avenue 5 #06-01. Fu Yu Building Singapore 554911 T: +1 713 937 9772 F: +1 713 937 9773 T: +82 2 6380 483 F: +82 2 3484 6778 T: +65 6645 9888 Saudi Arabia Office Middle East LLC - Dammam K.S.A. PLANT AT 2ND Industrial City Dammam 111, Jubail Street PO BOX: 70160 Al Khobar, Pin:31952. Kingdom of Saudi Arabia T: +966 3 812 2970 Eaton 1000 Eaton Boulevard Cleveland, OH 44122 United States Eaton.com (c) 2015 Eaton Corporation All Rights Reserved Printed in UK Ref: OVERV0816 August 2016 Eaton's Crouse-Hinds Business Eaton's Crouse-Hinds Business 1201 Wolf Street Syracuse, NY 13208 (866) 764-5454 crouse.customerctr@cooperindustries.com Eaton is a registered trademark. All other trademarks are property of their respective owners.