AC-DC Power Supplies Bus ConverterPower Module Type DPF1000 Ordering information DPF 1000 1 2 1Series name 2Output wattage R MODEL AC INPUT[V] MAX OUTPUT WATTAGE[W] DC OUTPUT VOLTAGE[V] DPF1000 AC85 - 264 1,000 DC360 AC170 - 264 1,500 SPECIFICATIONS INPUT OUTPUT PROTECTION CIRCUIT AND OTHERS ISOLATION ENVIRONMENT SAFETY OTHERS MODEL VOLTAGE[V] POWER FACTOR CORRECTION RANGE[V] CURRENT[A] FREQUENCY[Hz] INRUSH CURRENT[A] EFFICIENCY[%] POWER FACTOR LEAKAGE CURRENT[mA] *1 WATTAGE[W] *2 VOLTAGE[V] VOLTAGE ACCURACY[V] *3 OVERVOLTAGE PROTECTION[V] IOG ENA AUX OTHERS INPUT-OUTPUT INPUT, OUTPUT-FG OPERATING TEMP.,HUMID.AND ALTITUDE *4 STORAGE TEMP.,HUMID.AND ALTITUDE VIBRATION IMPACT AGENCY APPROVALS HARMONIC ATTENUATOR CASE SIZE/WEIGHT COOLING METHOD DPF1000 AC85 - 264 1f AC85 - 255 1f 11.5typ (ACIN 100V) 50/60 (47 - 63) 8.5typ (ACIN 200V) Limited by external resistance 90typ (ACIN 100V) 95typ (ACIN 200V) 0.98typ (ACIN 100V) 0.95typ (ACIN 200V) 0.75max (60Hz, According to IEC60950 and DEN-AN) 1,000 1,500 DC360 t20 DC400 - 450 The power factor corrector function stops Inverter operation monitoring, Open-collector output, Maximum sink current 10mA, Maximum allowance voltage 35V Enable signal, Open-collector output, Maximum sink current 10mA, Maximum allowance voltage 35V Auxiliary power supply for external signal, Output voltage:6.5 - 8.5V maximum, Output current:10mA Parallel operation possible (Current balancing function), N+1 redundant operation possible, Thermal protection Non isolated AC3,000V 1minute Cutoff current = 10mA, DC500V, 50MWmin (20t15C) -20 to +85C (Aluminum base plate), 20 - 95%RH (Non condensing) (Refer to DERATING CURVE), 3,000m (10,000feet) max -40 to +85C, 20 - 95%RH (Non condensing), 9,000m (30,000feet) max 10 - 55Hz, 49.0m/s2 (5G), 3minutes period, 60minutes each along X, Y and Z axis 196.1m/s2 (20G), 11ms, once each X, Y and Z axis UL60950-1, C-UL, EN60950-1, EN50178 Complies with DEN-AN and IEC60950-1 Complies with IEC61000-3-2 *5 118.6X12.7X85mm [4.67X0.5X3.35 inches] (WXHXD) /200g max Conduction cooling (e.g. heat radiation from the aluminum base plate to the attached heat sink) *1Refer to Input voltage derating. *2When the input voltage is more than 255V, the power factor corrector function stops, and the output voltage becomes rectified AC input voltage. *3The value included the output setting and the line regulation, the load regulation and the temperature regulation. However, the input voltage is in the power factor correction range. DPF-2 AC170 - 264 1f *4Please consult us in regard to use from -40C. *5Please contact us about class C. *External components are required. Refer to standard connection method. DPF1000 External view Aluminum Base Plate Recomending size for processing PCB (TOP VIEW) 106.68 [0.1] A SIGNAL PIN t=0.8t0.1 [0.01] 4-0.6t0.1 [0.03] 2.54 1t0.1 [0.04] [0.02] +1 3.0 -0.5 [0.12] 3.0t0.5 [0.12] 4-3.5 44.7 [0.14] [1.75] 106.68 [4.2] Dimensions in mm,[ Div. : 0.5inch ]= inches Weight: 200g max Tolerance: t0.3 [t0.012] Dimensions in mm,[ ]= inches Base Plate: Aluminum Mounting torque * Mounting hole screwing torque 0.49N*m(5.0kgf*cm)max [0.1] [4.2] 0.31 AC IN/DC OUT PIN 2.54 [0.1] [0.1] [0.1] AC2 - VOUT +VOUT R 2.54 [0.55] 2.54 AC1 13.97 [0.85] 21.59 [1.76] AUX IOG CB ENA AC IN 44.7 [0.1] [0.55] 2.54 SIGNAL PIN Name Plate A 13.97 [4] 4-M3 Mounting Hole (FG) 0.31 101.6 t0.5 2.54 [4.67] DC OUT 118.6t1 [0.5] [4.2] Case (PBT) [2.0] 106.68 50.8 [0.54] [0.85] 21.59 [2] 13.97 12.7t0.5 [0.05] [0.54] 85t1 Lot No. 4-1.2 [0.07] [3.35] 50.8 5-1.7 13.97 4-M3 Mounting Hole for Heat Sink(FG) Performance data OUTPUT VOLTAGE FOR INPUT STATIC CHARACTERISTICS 390 400 380 V OUTPUT VOLTAGE OUTPUT VOLTAGE V 370 350 330 Input Voltage AC100V Input Voltage AC200V 310 0 0.8 0 1.6 2.4 3.2 4.0 4.8 OUTPUT CURRENT 5.6 6.4 7.2 320 Output Wattage 1000W Output Wattage 1500W 300 0 100 140 180 INPUT VOLTAGE A 220 260 V HARMONIC CURRENT (AC230V ) 10.0 10.0 Harmonic current standard of class A (at odd number) A Harmonic current standard of class A (at odd number) A 1.0 1.0 HARMONIC CURRENT HARMONIC CURRENT 340 0 8.0 HARMONIC CURRENT (AC100V ) 0.1 0.01 0.001 360 1 10 20 HARMONIC ORDER 30 40 0.1 0.01 0.001 1 10 20 30 40 HARMONIC ORDER DPF-3 Mouser Electronics Authorized Distributor Click to View Pricing, Inventory, Delivery & Lifecycle Information: Cosel: DPF1000