-6-
9. UNIT LIFE AND RELIABILITY
9.1 Life Magnetic head : 300,000 times pass
(conditions) In a clean office room.
In damp or dirty atmosphere, the life may be 1/3 to 1/5 of the
above figure.
9.2 Error rate : Less than 0.1 %
(conditions) This error rate is obtained when a new normal card (data”1010・・”)
is horizontally passed at the standard speed (30 cm/sec ~ 60cm/sec) by manual operatrion
in the clean environment at delivery from our company.
10. GUARANTEE
If defects should occur within one year after the delivery of the card reader due to
improper material or bad workmanship, the defective parts shall be replaced or
repaired, free of charge.
11. MAINTENANCE
Because of difficulty in changing components on the P.C Board, replacement of
whole unit is recommended for service and maintenance.
12. CAUTIONS ON THE USE
Please be noted that we do not guarantee proper performance of the card reader
if it is used other than the indicated specification range.
12.1 At the installation
(1) Do not drop or bump anything against a card reader. Otherwise, failure may
be the result.
(2) Do not touch the P.C.B. with bear hands.
(3) Be sure to install on a flat surface so as to prevent any force to be applied to
the Card reader at the installation.
(4) Do not drop or bump anything against a card reader. Otherwise, failure
may be the result.
(5) The card reader should avoid installation of the following environment.
・ Watery, humid or dusty place.
・ Near machines which generate magnetic field or inducted noise.
(Printer ,LED display, CRT etc.)
・ Place which gets direct sunlight.