S134 Page 1SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE ©2003 TELEDYNE RELAYS
www.teledynerelays.com S134/1203/Q1
CENTIGRID®AND TO-5
SERIES
S134
CENTIGRID®
SURFACE MOUNT
COMMERCIAL RELAYS
SENSITIVE DPDT
DESCRIPTION
The Series S134 sensitive surface mount Centigrid®relay is an ultraminiature,
hermetically sealed, armature relay. The low profile height (.460") and .100" lead
spacing make it ideal for applications where extreme packaging density and/or
close PC board spacing are required. The specially formed leads are pre-tinned to
make the relays ideal for most types of surface mount solder reflow processes.
The basic design and internal construction are identical to the Series 134
Centigrid®relays, and are capable of meeting Teledyne Relays’ T2R®requirements.
The following unique construction features and manufacturing techniques provide
overall high reliability and excellent resistance to environmental extremes:
All welded construction.
Unique uni-frame design providing high magnetic efficiency and mechanical
rigidity.
High force/mass ratios for resistance to shock and vibration.
Advanced cleaning techniques provide maximum assurance of internal
cleanliness.
Precious metal alloy contact material with gold plating assures excellent high
current
and dry circuit switching capabilities.
The Series S134D and S134DD relays have internal discrete silicon diodes for coil
suppression and polarity reversal protection.
The sensitive surface mount Centigrid®relay has a high resistance coil, thus
requiring extremely low operating power (200 mw typical). The advantages of
reduced heat dissipation and power supply demands are a plus.
INTERNAL CONSTRUCTION
SERIES
DESIGNATION RELAY TYPE
S134 DPDT basic relay
S134D DPDT relay with internal diode for coil transient suppression
S134DD DPDT relay with internal diodes for coil transient suppression and polarity
reversal protection
UNI-FRAME
ARMATURE
UPPER
STATIONARY
CONTACT
LOWER
STATIONARY
CONTACT
MOVING
CONTACT
ENVIRONMENTAL AND
PHYSICAL SPECIFICATIONS
Temperature
(Ambient)
Storage –65°C to +125°C
Operating –55°C to +85°C
Vibration
(General Note 1) 30 g’s to 3000 Hz
Shock
(General Note 1)
75 g’s,
6 msec, half-sine
Acceleration 50 g’s
Enclosure Hermetically sealed
Weight 0.15 oz. (4.3g) max.
Reflow Temperature 260°C max. temp.
1 min. max.
©2003 TELEDYNE RELAYS SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE S134 Page 2
www.teledynerelays.com S134/1203/Q1
CENTIGRID®AND TO-5
300
250
200
150
100
50
0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0
LOAD CURRENT (AMPS DC)
FIGURE 1
TYPICAL DC CONTACT RATING (RESISTIVE) (Note 2)
LOAD VOLTAGE (VDC)
SERIES S134
GENERAL ELECTRICAL SPECIFICATIONS (–65°C to +125°C unless otherwise noted) (Notes 2 & 3)
DETAILED ELECTRICAL SPECIFICATIONS (–65°C to +125°C unless otherwise noted) (Note 3)
Contact Arrangement 2 Form C (DPDT)
Rated Duty Continuous
Contact Resistance 0.1 ohm max. before life; 0.2 ohm max. after life at 1A/28Vdc (measured 1/8" from header)
Contact Load Ratings (DC)
(See Fig. 2 for other DC
resistive voltage/current ratings)
Resistive: 1 Amp/28Vdc
Inductive: 200 mA/28Vdc (320 mH)
Lamp: 100 mA/28Vdc
Low Level: 10 to 50 μA/10 to 50mV
Contact Load Ratings (AC) Resistive: 250 mA/115Vac, 60 and 400 Hz (Case undergrounded)
100 mA/115Vac, 60 and 400 Hz (Case grounded)
Contact Life Ratings
10,000,000 cycles (typical) at low level
1,000,000 cycles (typical) at 0.5A/28Vdc resistive
100,000 cycles min. at all other loads specified above
Contact Overload Rating 2A/28Vdc Resistive (100 cycles min.)
Contact Carry Rating Contact factory
Coil Operating Power 200 milliwatts typical at nominal rated voltage @ 25°C
Operate Time 4.0 msec max. at nominal rated voltage @ 25°C
Release Time S134 Series: 2.0 msec max. S134D, S134DD Series: 7.5 msec max.
Contact Bounce 1.5 msec max.
Intercontact Capacitance 0.4 pf typical
Insulation Resistance 10,000 megohms min. between mutually isolated terminals
Dielectric Strength Atmospheric pressure: 500 Vrms/60Hz 70,000 ft.: 125 Vrms/60Hz
Negative Coil Transient (Vdc) S134D, S134DD 1.0 max
Diode P.I.V. (Vdc) S134D, S134DD 100 min.
BASE PART
NUMBERS
(See Note 10 for full P/N example)
S134-5
S134D-5
S134DD-5
S134-6
S134D-6
S134DD-6
S134-9
S134D-9
S134DD-9
S134-12
S134D-12
S134DD-12
S134-18
S134D-18
S134DD-18
S134-26
S134D-26
S134DD-26
Coil Voltage (Vdc) Nom. 5.0 6.0 9.0 12.0 18.0 26.5
Max. 7.5 10.0 15.0 20.0 30.0 40.0
Coil Resistance
(Ohms ±10% @25°C)
S134, S134D 100 200 400 800 1600 3200
S134DD (Note 4) 64 125 400 800 1600 3200
Coil Current (mAdc @25°C)
(134DD Series) Note 5 Min. 56.8 36.3 18.1 12.5 9.6 7.2
Max. 78.1 48.9 23.6 16.0 12.2 9.0
Pick-up Voltage (Vdc, Max.) S134, S134D 3.5 4.5 6.8 9.0 13.5 18.0
S134DD 3.7 4.8 8.0 11.0 14.5 19.0
Drop-out Voltage (Vdc)
S134, S134D Min. 0.12 0.18 0.35 0.41 0.59 0.89
Max. 2.5 3.2 4.9 6.5 10.0 13.0
S134DD Min. 0.7 0.8 0.9 1.0 1.1 1.3
Max. 2.6 3.0 4.5 5.8 9.0 13.0
S134 Page 3SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE ©2003 TELEDYNE RELAYS
www.teledynerelays.com S134/1203/Q1
CENTIGRID®AND TO-5
.335 MAX
(8.51)
.031 REF (.79)
4° MAX TYP
4° MAX TYP
.035 REF
(.89)
.045 MIN 8 PL
(1.14)
.100 4 PL
(2.54)
.200
(5.08)
.100 TYP (2.54)
.375 MAX
(9.53) .460 MAX
(11.68) DIMENSIONS ARE SHOWN
IN INCHES (MILLIMETERS)
Ø.017 REF
(.43) 2° ±2° TYP
.378 +.030
–.020 TYP
9.60 +.76
–.51
()
.200
(5.08)
(Note 6)
.375 SQ MAX
(9.53)
.200
(5.08)
.410 MIN
(10.41)
OUTLINE DIMENSIONS AND RECOMMENDED PAD LAYOUT (Notes 7, 8 & 9)
GENERAL NOTES
1. Relay contacts will exhibit no chatter in excess of 10 μsec or transfer in excess of 1 μsec.
2. “Typical” characteristics are based on available data and are best estimates. No on-going
verification tests are performed.
3. Unless otherwise specified, parameters are initial values.
4. For reference only. Coil resistance not directly measurable at relay terminals due to
internal series semiconductor.
5. Measured at nominal voltage for 5 sec. max.
6. Position of leads as they emerge from relay base.
7. Leads will fit noted pad layout with no overhang.
8. Lead ends are coplanar within .008" wide tolerance zone.
9. Terminals coated with SN60 or SN63 solder per QQ-S-571. Kovar exposed at sheared
end of leads.
10.
6
543
781
2
S134
S134D
S134DD
6
543
781
2
(±)
(+)
6
543
781
2
(±)
(+)
TERMINAL LOCATIONS
& SCHEMATIC DIAGRAMS
SCHEMATICS ARE VIEWED
FROM TERMINALS
SERIES S134
Teledyne Part Numbering System for Surface Mount Relays
SURFACE
MOUNT
S 134 D - 26
SERIES NO.
D = SUPPRESSION DIODE
DD = SUPPRESSION AND POLARITY PROTECTION DIODES COIL VOLTAGE
11. Add "/R" to end of part number for RoHS compliant solder coated pins (Sn99.3/Cu0.7).
Pad designation and
bottom view dimensions Height For use with the following: Dim. H
Max.
“M4” Pad for TO-5
ER411T
ER412, ER412D, ER412DD .295 (7.49)
712, 712D, 712TN,
RF300, RF310, RF320 .300 (7.62)
ER420, ER422D, ER420DD, 421,
ER421D, ER421DD, ER422, ER422D,
ER422DD, 722, 722D, RF341
.305 (7.75)
ER431T, ER432T,
ER432, ER432D, ER432DD .400 (10.16)
732, 732D, 732TN, RF303, RF313,
RF323 .410 (10.41)
RF312 .350 (8.89)
“M4” Pad for TO-5
ER411, ER411D, ER411DD .295 (7.49)
ER431, ER431D, ER431DD .400 (10.16)
RF311 .300 (7.62)
RF331 .410 (10.41)
“M4” Pad for Centigrid®
172, 172D .305 (7.75)
ER114, ER114D, ER114DD,
J114, J114D, J114DD .300 (7.62)
ER134, ER134D, ER134DD,
J134, J134D, J134DD .400 (10.16)
RF100 .315 (8.00)
RF103 .420 (10.67)
“M9” Pad for Centigrid®
122C, A152 .320 (8.13)
ER116C, J116C .300 (7.62)
ER136C, J136C .400 (10.16)
RF180 .325 (8.25)
A150 .305 (7.75)
Notes:
1. Spacer pad material: Polyester  lm.
2. To specify an “M4” or “M9” spacer pad, refer to the mounting variants portion of the part numbering
example in the applicable datasheet.
3. Dimensions are in inches (mm).
4. Unless otherwise speci ed, tolerance is ± .010 (.25).
5. Add 10 m to the contact resistance show in the datasheet.
6. Add 0.01 oz. (0.25 g) to the weight of the relay assembly shown in the datasheet.
Ø.150
[3.81]
(REF)
Dim H
MAX
Dim H
MAX
Dim H
MAX
.156
[3.96]
(REF)
.256
[6.5]
(REF)
Dim H
MAX
Appendix A: Spacer Pads
© 2008 Teledyne Relays SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE
Pad designation and
bottom view dimensions Height For use with the following: Dim. H
Max.
“M” Pad 5/ 6/
ER411T, J411T, ER412, ER412D
ER412DD, J412, J412D, J412DD
ER412T, J412T
.388 (9.86)
712, 712D, 712TN .393 (9.99)
ER431T, J431T, ER432, ER432D
ER432DD, J432, J432D, J432DD
ER432T, J432T
.493 (12.52)
732, 732D, 732TN .503 (12.78)
ER420, J420, ER420D, J420D
ER420DD, J420DD, ER421, J421
ER421D, J421D, ER421DD
J422D, ER422DD, J422DD, 722
.398 (10.11)
“M2” Pad 7/ 8/
ER411T
ER412, ER412D, ER412DD
J412, J412D, J412DD
.441 (11.20)
712, 712D .451 (11.46)
ER421, ER421D, ER421DD
722, 732D .451 (11.46)
ER431T
ER432, ER432D, ER432DD .546 (13.87)
732, 732D .556 (14.12)
“M3” Pad 5/ 6/ 9/
ER411, ER411D, ER411DD
ER411TX
ER412X, ER412DX, ER412DDX
ER412TX
.388 (9.86)
712X, 712DX, 712TNX .393 (9.99)
ER420X, ER420DX, ER420DDX
ER421X, ER421DX, ER421DDX
ER422X, ER422DX
ER422DDX, 722X, 722DDX
.398 (10.11)
ER431, ER431D, ER431DD
ER431TX
ER432X, ER432DX, ER432DDX
ER432TX
.493 (12.52)
732X, 732DX, 732TNX .503 (12.78)
Notes:
1. Spreader pad material: Diallyl Phthalate.
2. To specify an “M”, “M2” or “M3” spreader pad, refer to the mounting variants portion of the part number example
in the applicable datasheet.
3. Dimensions are in inches (mm).
4. Unless otherwise speci ed, tolerance is ± .010” (0.25).
5/. Add 25 m to the contact resistance shown in the datasheet.
6/. Add .01 oz. (0.25 g) to the weight of the relay assembly shown in the datasheet.
7/. Add 50 m to the contact resistance shown in the datasheet.
8/. Add 0.025 oz (0.71 g) to the weight of the relay assembly shown in the datasheet.
9/. M3 pad to be used only when the relay has a center pin (e.g. ER411M3-12A, 722XM3-26.)
.370 [9.4]
MAX SQ
.150
[3.81]
.100
[2.54]
.200
[5.08]
.300
[7.62]
.100
[2.54]
Dim H
MAX
.370
[9.4]
MIN
.014
[0.36]
(REF)
.390 [9.91]
SQ
.300
[7.62]
.100
[2.54]
.300
[7.62]
.100
[2.54] .150
[3.81]
.150
[3.81]
.130
[3.3]
Dim H
MAX
.370 [9.4]
MAX SQ
.150
[3.81]
.100
[2.54]
.200
[5.08]
.300
[7.62]
.100
[2.54]
Dim H
MAX
.370
[9.4]
MIN
.014
[0.36]
(REF)
Appendix A: Spreader Pads
(800) 284-7007 • www.teledynerelays.com +44 (0) 1236 453124 • www.teledyne-europe.com © 2008 Teledyne Relays
.100
[2.54]
.100
[2.54]
.100
[2.54]
"Y" POSITION
"Z" POSITION
.100
[2.54]
.100
[2.54]
.100
[2.54]
"W" POSITION
"U" POSITION
(ER116C and ER136C only)
"X" POSITION
"Z" POSITION
"Y" POSITION
.050
[1.27]
36°±3°
Ø.200
[Ø5.08]
"Z" POSITION
"Y" POSITION
"X" POSITION
45°±3°
"Z" POSITION
"Y" POSITION
Ø.200
[Ø5.08]
Centigrid® Relays:
RF100, RF103, ER114, ER134, 172
Centigrid® Relays:
RF180, ER116C, 122C, ER136C
TO-5 Relays:
ER411T, ER412, ER412T, ER420, ER421, ER422,
ER431T, ER432, ER432T, 712, 712TN, 400H, 400K,
400V, RF300, RF303, RF341, RF312, RF310, RF313,
RF320, RF323
TO-5 Relays:
ER411, ER431, RF311, RF331
NOTES
1. Terminal views shown
2. Dimensions are in inches (mm)
3. Tolerances: ± .010 (±.25) unless otherwise speci ed
4. Ground pin positions are within .015 (0.38) dia. of true position
5. Ground pin head dia., 0.035 (0.89) ref: height 0.010 (0.25) ref.
6. Lead dia. 0.017 (0.43) nom.
Indicates ground pin position
Indicates glass insulated lead position
Indicates ground pin or lead position
depending on relay type
Appendix A: Ground Pin Positions
© 2008 Teledyne Relays SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE