IEC Appliance Outlet F or H, Screw-on Mounting, Front Side, Solder, PCB or Quick-connect Terminal
Flange with countersunk holes Flange with through holes special type
Approvals and Compliances
F
70° C
H
70° C
Description
- Panel Mount :
Screw-on mounting , from front side
- 1 Function :
- Connector , Pin temperature 70 °C , protection class I or II ,
- Solder, Quick Connect or PCB Terminal
Weblinks
pdf datasheet, html-datasheet, General Product Information, Distributor-
Stock-Check, Accessories, Detailed request for product
Technical Data
Ratings IEC 10 A / 250 VAC; 50 Hz
Ratings UL/CSA 15 A / 250 VAC; 60 Hz
Dielectric Strength > 4 kVAC between L-N
> 2 kVAC between L/N-PE
(1 min/50 Hz)
Allowable Operation Tempe-
rature
-25 °C to 70 °C
IP-Protection from front side IP 20 acc. to IEC 60529
Insulation cover Suitable for appliances with protection
class I or II acc. to IEC 61140
Terminal Solder, Quick Connect or PCB Terminal
straight
Material: Housing PA6, black or grey, UL 94V-0
Approvals and Compliances
Detailed information on product approvals, code requirements, usage instructions and detailed test conditions can be looked up in Details about
Approvals
Approvals
The approval mark is used by the testing authorities to certify compliance with the safety requirements placed on electronic products.
Approval Reference Type: 5091
Approval Logo Certificates Certification Body Description
VDE Approvals VDE VDE Certificate Number: 40010295
UL Approvals UL UL File Number: E57445
CSA Approvals CSA CSA Certification Record: 27324
CSA Approvals CSA CCC File Number: 27324
2
Connectors (Inlets/Outlets)
5091 https://www.schurter.com /PG07
Connectors
Product standards
Product standards that are referenced
Organization Design Standard Description
Designed according to IEC 60320-1 Appliance couplers for household and similar general purposes
Designed according to IEC 60320-1 Appliance couplers for household and similar general purposes
Designed according to UL 498 Standard for Attachment Plugs and Receptacles
Designed according to CSA C22.2 no. 42 General Use Receptacles, Attachment Plugs, and Similar Wiring Devices
Application standards
Application standards where the product can be used
Organization Design Standard Description
Designed for applications acc. IEC/UL 60950 IEC 60950-1 includes the basic requirements for the safety of information
technologyequipment.
Compliances
The product complies with following Guide Lines
Identification Details Initiator Description
CE declaration of conformity SCHURTER AG The CE marking declares that the product complies with the applicable
requirements laid down in the harmonisation of Community legislation on
its affixing in accordance with EU Regulation 765/2008.
RoHS SCHURTER AG EU Directive RoHS 2011/65/EU
China RoHS SCHURTER AG The law SJ / T 11363-2006 (China RoHS) has been in force since 1 March
2007. It is similar to the EU directive RoHS.
REACH SCHURTER AG On 1 June 2007, Regulation (EC) No 1907/2006 on the Registration,
Evaluation, Authorization and Restriction of Chemicals 1 (abbreviated as
"REACH") entered into force.
Dimensions [mm]
23.2
26.145
+0.2
- 0
15.8
15.6
24
35
18.135
23
4
+0.2
- 0
ø 3.2
Flange with countersunk holes
3
Connectors (Inlets/Outlets) 5091
https://www.schurter.com /PG07
Connectors
26.344.5
5.6
24
18.235
ø10
ø3.2
35
0.9
77
4
ø1.5
Flange with through holes special type
Config. Code
5091|-|H|-|A|B|C|0-|D|-|E|O|
The characters are placeholders for the correspondingly keys of selections from the key tables.
5091|-| H |-|A|B|C|0-|D|-|E|O| = Type
Type Configuration
key
protection class II B
protection class I X
5091|-|H|-| A |B|C|0-|D|-|E|O| = Terminals
Terminal L Configuration
key
solder terminal
1
PCB-terminal standard (additional solder terminal)
4
Blade terminal (6.3 x 0.8 mm)
9
5091|-|H|-|A| B |C|0-|D|-|E|O| = Terminals
Terminal N Configuration
key
solder terminal 1
PCB-terminal standard (additional solder terminal) 4
Blade terminal (6.3 x 0.8 mm) 9
Symbols similar as in table A
5091|-|H|-|A|B| C |0-|D|-|E|O| = Terminals
Terminal Ground Configuration
key
without terminal 0
solder terminal 1
PCB-terminal standard (additional solder terminal) 4
Blade terminal (6.3 x 0.8 mm) 9
Symbols similar as in table A
5091|-|H|-|A|B|C|0-| D |-|E|O| = Color
Color Configuration
key
Black A
Grey B
5091|-|H|-|A|B|C|0-|D|-| E |O| = Style
Style Configuration
key
flange with countersunk holes 1
flange with through holes 2
flange with through holes (special type) 7
5091|-|H|-|A|B|C|0-|D|-|E| O | = Features
Features Configuration
key
not used 0
dead cover 1
holder for 1 fuse (text legible, when inlet on top) 2
holder for 1 fuse (text legible, when inlet on bottom) 3
holder for 1 or 2 fuses (text legible, when inlet on top) 4
4
Connectors (Inlets/Outlets)
5091 https://www.schurter.com /PG07
Connectors
Features Configuration
key
holder for 1 or 2 fuses (text legible, when inlet on bottom) 5
voltage selector with 1 fuse 6
voltage selector with 2 fuses 7
thermal circuit breaker for rated current 4A A
thermal circuit breaker for rated current 6A B
Features Configuration
key
thermal circuit breaker for rated current 8A C
thermal circuit breaker for rated current 10A D
thermal circuit breaker for rated current 15A E
thermal circuit breaker for rated current 20A F
All Variants
Type Terminals L / N Terminal Ground Color Style Features Config. Code Order Number
protection class I solder terminal solder terminal Grey flange with countersunk holes - 5091-X-1110-B-1 6182.0002
protection class I PCB-terminal stan-
dard (additional
solder terminal)
PCB-terminal stan-
dard (additional
solder terminal)
Black flange with through holes
(special type)
- 5091-X-4440-A-7 6182.0004
protection class I PCB-terminal stan-
dard (additional
solder terminal)
PCB-terminal stan-
dard (additional
solder terminal)
Grey flange with through holes
(special type)
- 5091-X-4440-B-7 6182.0005
protection class I Blade terminal (6.3
x 0.8 mm)
Blade terminal (6.3
x 0.8 mm)
Black flange with countersunk holes - 5091-X-9990-A-1 6182.0006
protection class I Blade terminal (6.3
x 0.8 mm)
Blade terminal (6.3
x 0.8 mm)
Grey flange with countersunk holes - 5091-X-9990-B-1 6182.0008
The listet variants should be available from stock Other versions on request www.schurter.com/contact
Most Popular.
Availability for all products can be searched real-time:https://www.schurter.com/en/Stock-Check/Stock-Check-SCHURTER
Packaging unit 100 Pcs
Mating Inlets/Plugs
Category / Description
Appliance Inlet Overview complete
6100-3, Mounting: Screw, Solder terminals or quick connect terminals, Appliance Inlet: IEC C14 6100-3
6100-4, Mounting: Snap-in, Solder terminals or quick connect terminals, Appliance Inlet: IEC C14 6100-4
G-Stecker, Mounting: Appliance Inlet : IEC C14 Without fuse holder 6150
6010, Mounting: Snap-in, Solder, quick-connect, screw, PCB, Appliance Inlet: IEC C14 6010
0711, Mounting: Snap-in, 0.8 mm, Solder, Appliance Inlet: IEC C14 0711
Appliance Inlet further types to 5091 ...
Distribution Unit Overview complete
Distribution Unit for Snap-in Mounting with 1 IEC Appliance Inlet C14 and 1 Appliance Outlet F 0712
Distribution Unit with 1 IEC Appliance Inlet C14 and 2 Appliance Outlets F, Shuttered 4741
Distribution Unit with 1 IEC Appliance Inlet C14 and 4 Appliance Outlets F 4747
Distribution Unit with 1 IEC Appliance Inlet C14 or Power Cord, 4, 5 or 6 IEC Appliance Outlets F and Extra Components 4740
EMC Power Strip with Line Filter FLBB
Distribution Unit further types to 5091
IEC Inlet Filter Overview complete
GRF2, Mounting: Rear Side, With EMC-shield and without line filter, 10 A, Plug Connector, Appliance Inlet: IEC C14,
Suitable for appliances with protection class I GRF2
5110, Mounting: Screw, Front Side, Filter: Standard and Medical Version, Without fuse holder: 10 A, Thermoplastic
Appliance Inlet: IEC C14, prewired, Suitable for appliances with protection class I 5110
KFS, Mounting: Screw, Front Side, Filter: Standard Version, Without fuse holder: 10 A, Appliance Inlet: IEC C14, pre-
wired KFS
IEC Inlet Filter further types to 5091
5
Connectors (Inlets/Outlets) 5091
https://www.schurter.com /PG07
Connectors
Category / Description
Power Entry Module Overview complete
DC11, Mounting: Screw, Rocker switch: non-illuminated or illuminated 1 or 2 pole, Quick connect terminals 4.8 x 0.8
mm, Appliance Inlet: IEC C14, Without fuse holder: Suitable for appliances with protection class I or II DC11
KEB1, Mounting:Screw, Quick connect terminals 4.8 x 0.8 mm, Without fuse holder: Rocker switch, non-illuminated or
illuminated, red, 1-pole, Appliance Inlet: IEC C14, 250 VAC, prewired, Suitable for appliances with protection class I KEB1
KEB2, Mounting:Screw, Quick connect terminals 4.8 x 0.8 mm, Without fuse holder: Rocker switch, non-illuminated or
illuminated, 2-pole, Appliance Inlet: IEC C14, 250 VAC, prewired, Suitable for appliances with protection class I KEB2
DC21, Mounting: Screw Rear Side, Rocker switch: non-illuminated or illuminated 2-pole, Quick connect terminals 4.8
x 0.8 mm Appliance Inlet: IEC C14, Without fuse holder: DC21
DD11, Mounting: Screw-on mounting, Rocker switch: non-illuminated or illuminated 2-pole, Quick connect terminals
4.8 x 0.8 mm, Appliance Inlet: IEC C14, With or without protection cover, Fuse holder: 1 or 2 pole, Suitable for appli-
ances with protection class I
DD11
Power Entry Module further types to 5091 ...
Power Entry Module with line filter Overview complete
KFB1, Mounting: Screw, Front Side, Filter: Standard Version, Without fuse holder: 10 A, Rocker switch: 1-pole, Appli-
ance Inlet: IEC C14, prewired KFB1
KFB2, Mounting: Screw, Front Side, Filter: Standard and Medical Version, Without fuse holder: 10 A, Rocker switch:
2-pole, Appliance Inlet: IEC C14, prewired KFB2
DC12, Mounting: Screw, Front-/Rear-Side, Filter, Standard and Medical Version, Without fuse holder:10 A, Rocker
switch: 1 or 2 pole, non-illuminated or illuminated Appliance Inlet: IEC C14, prewired DC12
DC22 Mounting: Screw, Rear Side, PCB, 10 A, Filter: Standard and Medical Version, Without fuse holder: Rocker switch:
1 or 2 pole, non-illuminated or illuminated, Appliance Inlet: IEC C14, Suitable for appliances with protection class I DC22
DD12, Mounting: Screw-on mounting, Front Side, Filter, Standard and Medical Version, Fuse holder:1 or 2 pole, 10 A,
Rocker switch: 2-pole, non-illuminated Appliance Inlet: IEC C14, prewired DD12
Power Entry Module with line filter further types to 5091 ...
The specifications, descriptions and illustrations indicated in this document are based on current
information. All content is subject to modifications and amendments. Information furnished is believed
to be accurate and reliable. However, users should independently evaluate the suitability and test each
product selected for their own applications.
29.11.2017
Mouser Electronics
Authorized Distributor
Click to View Pricing, Inventory, Delivery & Lifecycle Information:
Schurter: