Special Features
Electrical Specs
150 Watts
BK60C-40
High Efficiency
• High efficiency, 5V@89%
• -40°C to 100°C baseplate operating
temperature (no derating)
• Positive and Negative enable function
• Low output ripple and noise
• High capacitive load limit on start-up
• Remote sense compensation
• Regulation to zero load
• Fixed frequency switching (300 kHz)
Operating temperature (baseplate):
-40°C to +100°C
Storage temperature: -55°C to +105°C
Overtemperature protection: 110°C typical
MTBF: >1 million hours
Input
Input range 36-75 VDC
Input Surge 100V / 100ms
Efficiency 89% @ 3.3V (typ)
Output
Load regulation 10mV typical down to no load
(output below 5V)
Line regulation 10mV typical
(outpt below 5V)
Ripple and noise 200mV p-p max)
Remote sense Up to 0.5V
Output voltage
adjust range ±20% of nominal output
Transient Response 10% max deviation with 25% to 75%
full load (output 5V and above)
200mV
Overvoltage Protection 130% nominal output
(output 5V and above)
160% nominal outpt
(2.2V output)
140% nominal output
(3.3V output)
Current Limit 115% maximum output
Control
Voltage Adjust 90 to 110%
Enable TTL compatible (positive & negative
enable options)
Notes:
1. Nominal values apply with sense pins connected and other
control pins unconnected.
2. Specifications subject to change without notice.
Environmental
Total Power: 150 Watts
Input Voltages: 48V
No. of Outputs: Single
UL UL 1950
CAN22.2-950
TUV EN60950
Safety
Astec Industry Standard
America’s (USA): 1-888-41-ASTEC Europe (UK): 44 (1384) 842-211 Asia (HK): 852-2437-9662