HWS15/A
85 ~ 265VAC (47 ~ 63Hz) or 120 ~ 370VDC
Input Current (100/200VAC)(Typ) (*1)
14A at 100VAC, 28A at 200VAC, Ta=25°C, Cold Start
Built to meet IEC61000-3-2
0<Ta<60°C
-10<Ta<0°C
Less than 0.5mA. 0.2mA(Typ) at 100VAC / 0.4mA(Typ) at 230VAC
-10 ~+60°C (-10 ~+40°C:100%,+50°C:60%,+60°C:20%)
Input - FG : 2kVAC (20mA), Input - Output : 3kVAC (20mA)
Output - FG : 500VAC (100mA) for 1min
at 25°C and 70%RH Output - FG : 500VDC
At no operating, 10 ~ 55Hz (Sweep for 1min)
Constant, X,Y,Z 1hour each.
Approved by UL60950-1, CSA60950-1, EN60950-1, EN50178
Built to meet UL508, DENAN
Built to meet SEMI-F47 (200VAC Line only)
Built to meet EN55011/EN55022-B, FCC-B, VCCI-B
Built to meet EN55011/EN55022-B, FCC-B, VCCI-B
Built to meet IEC61000-4-2(Level 2,3), -3(Level 3), -4(Level 3),
-5(Level 3,4), -6(Level 3), -8(Level 4), -11
31.5 x 82 x 80 ( Refer to Outline Drawing )
*Read instruction manual carefully, before using the power supply unit.
=NOTES=
*1. At 100/200VAC, Ta=25°C and maximum output power.
*2. For cases where conformance to various safety specs (UL, CSA, EN) are required,
to be described as 100 ~ 240VAC(50/60Hz).
*3. Not applicable for the in-rush current to Noise Filter for less than 0.2ms.
*4. Measure with JEITA RC-9131A probe, Bandwidth of scope :100MHz.
For start up at low ambient temperature and low input voltage, output ripple noise might not meet specification.
However, there is no overshoot at start up and output ripple noise specification can be met after one second.
*5. 85 ~ 265VAC , constant load.
*6. No load-Full load, constant input voltage.
*7. Foldback current limit with automatic recovery. Not operate at over load or dead short condition for more than 30seconds.
*8. OVP circuit will shutdown output, manual reset (Re power on).
*9. At 100/200VAC , Ta=25°C, nominal output voltage and maximum output current.
Measured by the each measuring method of UL,CSA,EN and DENAN(at 60Hz).
Ratings - Derating at standard mounting.
- Load (%) is percent of maximum output power or maximum output current, whichever is greater.
- As for other mountings, refer to derating curve (A224-01-02/A_).
As for DENAN, built to meet at 100VAC.