MYRRA - SERIE 44000 EI 30-18 2,3-2,8 VA MYRRA - SERIE 44000 EI 30-18 2,3-2,8 VA EI 30-18 SERIE 44000 2,3-2,8 VA Primary Voltage 117 V * Vacuum filling * Two compartments bobbins * Self-extinguishing plastics UL 94 VO * Degree of protection IP 00 * 70 grams weight * Resin class B CEI 85 (20 000h testing to CEI 126) * Inherently short-circuits proof * Insulation voltage 4 KV (6 KV MYRRA test) * 30 V model is VDE EN 60742 certified (Production on request) * 100% tested production * Certification : CCA procedure on request * To be noted : 2 * 18 V and 2 * 24 V models are non approved. Protection transformers according to EN 60742 circuit isolation tranformer. http://www.myrra.ie/44000-5.html (1 of 3)5/22/2007 4:14:59 PM Reference Secondary Secondary No-load Ambient, Rating Voltage Currant Voltage Temperature VA V mA V C 44169 6 383 10,5 T 70 B 2,3 44170 9 256 15,7 T 70 B 2,3 44171 12 192 21 T 70 B 2,3 44172 15 128 31,4 T 70 B 2,3 44173 18 128 31,4 T 70 B 2,3 44174 24 96 41,9 T 70 B 2,3 44175 2x6 2 x 192 2 x 10,5 T 70 B 2,3 44176 2x9 2 x 128 2 x 15,7 T 70 B 2,3 44177 2 x 12 2 x 96 2 x 21 T 70 B 2,3 44178 2 x 15 2 x 77 2 x 25,9 T 70 B 2,3 44179 2 x 18 2 x 64 2 x 31,4 T 70 B 2,3 44180 2 x 24 2 x 48 2 x 4,9 T 70 B 2,3 44774 6 450 10,5 T 50 B 2,7 44775 9 300 15,4 T 50 B 2,7 44776 12 225 21,1 T 50 B 2,7 44777 15 180 26,3 T 50 B 2,7 44778 18 150 30,9 T 50 B 2,7 44779 24 113 42 T 50 B 2,7 44780 2x6 2 x 225 2 x 10,5 T 50 B 2,7 44781 2x9 2 x 150 2 x 15,4 T 50 B 2,7 44782 2 x 12 2 x 113 2 x 21 T 50 B 2,7 44783 2 x 15 2 x 90 2 x 26,3 T 50 B 2,7 44784 2 x 18 2 x 75 2 x 31,5 T 50 B 2,7 44785 2 x 24 2 x 56 2 x 42,1 T 50 B 2,7 44786 6 467 10,5 T 40 B 2,8 44787 9 311 15,4 T 40 B 2,8 MYRRA - SERIE 44000 EI 30-18 2,3-2,8 VA 44788 12 233 21,1 T 40 B 2,8 44789 15 187 26,3 T 40 B 2,8 44790 18 156 30,9 T 40 B 2,8 44791 24 117 42,1 T 40 B 2,8 44792 2x6 2 x 233 2 x 10,5 T 40 B 2,8 44793 2x9 2 x 156 2 x 15,4 T 40 B 2,8 44794 2 x 12 2 x 117 2 x 21,1 T 40 B 2,8 44795 2 x 15 2 x 93 2 x 26,3 T 40 B 2,8 44796 2 x 18 2 x 77 2 x 31,5 T 40 B 2,8 44797 2 x 24 2 x 58 2 x 42,1 T 40 B 2,8 EI 30-18 SERIE 44000 2,3-2,8 VA Primary Voltage 230 V Secondary Secondary No-load Ambient, Rating Reference Voltage Currant Voltage Temperature VA V mA V C http://www.myrra.ie/44000-5.html (2 of 3)5/22/2007 4:14:59 PM 44157 6 383 10,5 T 70 B 2,3 44158 9 256 15,7 T 70 B 2,3 44159 12 192 21 T 70 B 2,3 44160 15 128 31,4 T 70 B 2,3 44161 18 128 31,4 T 70 B 2,3 44162 24 96 41,9 T 70 B 2,3 44163 2x6 2 x 192 2 x 10,5 T 70 B 2,3 44164 2x9 2 x 128 2 x 15,7 T 70 B 2,3 44165 2 x 12 2 x 96 2 x 21 T 70 B 2,3 44166 2 x 15 2 x 77 2 x 25,9 T 70 B 2,3 44167* 2 x 18 2 x 64 2 x 31,4 T 70 B 2,3 44168* 2 x 24 2 x 48 2 x 4,9 T 70 B 2,3 44687 6 450 10,5 T 50 B 2,7 44688 9 300 15,4 T 50 B 2,7 44689 12 225 21,1 T 50 B 2,7 44690 15 180 26,3 T 50 B 2,7 44691 18 150 30,9 T 50 B 2,7 44692 24 113 42 T 50 B 2,7 44693 2x6 2 x 225 2 x 10,5 T 50 B 2,7 44694 2x9 2 x 150 2 x 15,4 T 50 B 2,7 44695 2 x 12 2 x 113 2 x 21 T 50 B 2,7 44696 2 x 15 2 x 90 2 x 26,3 T 50 B 2,7 44491* 2 x 18 2 x 75 2 x 31,5 T 50 B 2,7 MYRRA - SERIE 44000 EI 30-18 2,3-2,8 VA http://www.myrra.ie/44000-5.html (3 of 3)5/22/2007 4:14:59 PM 44492* 2 x 24 2 x 56 2 x 42,1 T 50 B 2,7 44697 6 467 10,5 T 40 B 2,8 44698 9 311 15,4 T 40 B 2,8 44699 12 233 21,1 T 40 B 2,8 44700 15 187 26,3 T 40 B 2,8 44701 18 156 30,9 T 40 B 2,8 44702 24 117 42,1 T 40 B 2,8 44703 2x6 2 x 233 2 x 10,5 T 40 B 2,8 44704 2x9 2 x 156 2 x 15,4 T 40 B 2,8 44705 2 x 12 2 x 117 2 x 21,1 T 40 B 2,8 44706 2 x 15 2 x 93 2 x 26,3 T 40 B 2,8 44493* 2 x 18 2 x 77 2 x 31,5 T 40 B 2,8 44494* 2 x 24 2 x 58 2 x 42,1 T 40 B 2,8