Slot-type Reflective Photomicrosensor EE-SPX301/401 EE-SPY30/40 CSM_EE-SPX301_401 EE-SPY30_40_DS_E_4_2 Photomicrosensor with light modulation is not influenced by external light. * Voltage-output models with wide operating voltage range (5 to 24 VDC). * Fitted with an easy-to-adjust optical axis mark. * Easy adjustment and optical axis monitoring with a light indicator. For the most recent information on models that have been certified for safety standards, refer to your OMRON website. Be sure to read Safety Precautions on page 5. Ordering Information Sensors Infrared light Appearance Sensing method Through-beam type (with slot) Sensing distance Output type Output configuration Model Dark-ON EE-SPX301 Light-ON EE-SPX401 Dark-ON EE-SPY301 Light-ON EE-SPY401 Dark-ON EE-SPY302 Light-ON EE-SPY402 3.6 mm (slot width) Horizontal type Reflective type NPN output 5 mm Vertical type Reflective type 5 mm Accessories (Order Separately) Type Connector Connector with Cable NPN/PNP Conversion Connector Connector Hold-down Clip Cable length 1m 0.46 m (total length) Model EE-1002 EE-1003 EE-2001 EE-1003A Remarks For EE-1003 only. * Refer to Accessories for details. 1 EE-SPX301/401 EE-SPY30/40 Ratings and Specifications Sensing method Item Through-beam type (with slot) Reflective type EE-SPX301, EE-SPX401 EE-SPY301, EE-SPY401 EE-SPY302, EE-SPY402 Models 5 mm (Reflection factor: 90%; white paper 15 x 15 mm) *1 Sensing distance 3.6 mm (slot width) Sensing object Opaque: 1 x 0.5 mm min. Differential distance 0.05 mm max. Light source GaAs infrared LED with a peak wavelength of 940 nm Indicator *2 Light indicator (red) Supply voltage 5 to 24 VDC 10%, ripple (p-p): 5% max. Current consumption Average: 15 mA max., Peak: 50 mA max. Control output NPN voltage output: Load power supply voltage: 5 to 24 VDC Load current: 80 mA max. OFF current: 0.5 mA max. 80 mA load current with a residual voltage of 1.0 V max. 10 mA load current with a residual voltage of 0.4 V max. Response frequency *3 500 Hz min. Ambient illumination 3,000 lx max. with incandescent light or sunlight on the surface of the receiver Ambient temperature range Operating: -10 to +55C Storage: -25 to +65C (with no icing) Ambient humidity range Operating: 5% to 85% Storage: 5% to 95% (with no condensation) Vibration resistance Destruction: 10 to 55 Hz, 1.5-mm double amplitude for 2 h each in X, Y, and Z directions Shock resistance Destruction: 500 m/s2 for 3 times each in X, Y, and Z directions Degree of protection IEC IP50 Connecting method Special connector (soldering not possible) Weight --0.2 mm max. (with a sensing distance of 3 mm, horizontally) 100 Hz min. Approx. 2.6 g Material Case Polycarbonate *1. Operation may not be possible near the Sensor. *2. The indicator is a GaP red LED (peak wavelength: 700 nm). *3. The response frequency was measured by detecting the following rotating disk. EE-SPX301 EE-SPX401 Disk EE-SPY30@ EE-SPY40@ 200 mm dia. 15 mm 2 mm 2 mm 15 mm 15 mm 2 mm Disk Disk 2 EE-SPX301/401 EE-SPY30/40 Engineering Data (Reference Value) EE-SPY301, EE-SPY401 EE-SPY301, EE-SPY401 Distance Y (mm) Distance Y (mm) Operating Range Characteristics 12 11 10 Sensing object: White paper (15 x 15 mm2) reflection factor: 90% 9 8 Operates Releases 7 6 12 11 10 Sensing object: 9 White paper (15 x 15 mm2) 8 reflection factor: 90% 7 Operates Y Releases 6 Y 5 5 4 4 X X 3 3 2 2 1 1 0 -5 -4 -3 -2 -1 0 1 2 3 4 0 -5 -4 5 -3 -2 -1 0 1 2 Distance X (mm) 12 11 Sensing object: White paper (15 x 15 mm2) reflection factor: 90% 10 9 4 5 EE-SPY302, EE-SPY402 Distance Y (mm) Distance Y (mm) EE-SPY302, EE-SPY402 3 Distance X (mm) 8 7 12 11 Sensing object: White paper (15 x 15 mm2) reflection factor: 90% 10 9 8 7 6 6 X X 5 5 Y 4 3 3 2 2 1 1 0 -5 -4 -3 -2 -1 0 1 2 3 4 Y 4 5 0 -5 -4 -3 -2 -1 0 1 2 Distance X (mm) 3 4 5 Distance X (mm) Sensing Position Characteristics EE-SPX301 (Z Direction) EE-SPX301 (Y Direction) Dark ON Dark ON Tr ON Tr ON Z Y Tr OFF 0 1 2 3 4 5 6 7 8 Z (mm) Tr OFF 0 1 2 3 4 5 6 7 8 Y (mm) 3 EE-SPX301/401 EE-SPY30/40 EE-SPY@@@ EE-SPY@@@ 6 Vcc = 24 V Length of cable = 0.5 m Thickness of cable = 0.3 mm2 Sensing object: 2 White paper (15 x 15 mm ) (reflection factor: 90%) 5 4 Sensing distance (mm) Sensing Distance vs. Object Area Characteristics Receiver output excess gain (multiple) Receiver Output Excess Gain vs. Sensing Distance Characteristics 15 Sensing object: white paper (reflection factor: 90%) l l 10 3 5 2 1 Operating level 0 0 12 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 22 32 52 72 102 202 302 502 Sensing area l2 (mm2) Distance d (mm) EE-SPY@@@ EE-SPY@@@ 110 100 90 80 Sensing object: 2 White paper (15 x 15 mm ) 60 (reflection factor: 90%) 70 Vcc = 24 V Length of cable = 0.5 m Thickness of cable = 0.3 mm2 EE-SPY301 EE-SPY302 50 40 30 d d + - + - 20 10 0 -40 -30 -20 -10 0 10 20 30 40 Angle () Operating distance/release distance (mm) Dependency on Cable Length for Operation Distance/Release Distance Relative sensing distance d (%) Sensing Angle vs. Sensing Distance Characteristics 20 18 16 Sensing object: 2 White paper (15 x 15 mm ) (reflection factor: 90%) Ta = 25C Vcc = 4.5 V RL = 4.7 k Lead: AWG24 (A) 14 (B) 12 10 C: 10 F Attach externally 8 4 (A): Using direct cable extension. (B): Using an externally attached capacitance of 10 F. 2 Operates Releases 6 0 0.1 0.3 0.5 0.7 1.0 3 5 7 10 Length of cable (m) 4 EE-SPX301/401 EE-SPY30/40 I/O Circuit Diagrams NPN Output Model Output configuration Timing charts Output circuit Incident Interrupted EE-SPX401 EE-SPY401 EE-SPY402 Light indicator ON (red) OFF Light-ON ON Output transistor Load 1 (relay) OFF Operates Light indicator (red) Releases H L Load 2 1.5 to 3 mA Load 1 OUT Ic Main circuit Incident Interrupted EE-SPX301 EE-SPY301 EE-SPY302 Light indicator ON (red) OFF Dark-ON Load 2 Load 2 * Voltage output (when the sensor is connected to a transistor circuit) ON Output transistor Load 1 (relay) 5 to 24 VDC OFF Operates Releases H L Safety Precautions Refer to Warranty and Limitations of Liability. WARNING This product is not designed or rated for ensuring safety of persons either directly or indirectly. Do not use it for such purposes Precautions for Correct Use Make sure that this product is used within the rated ambient environment conditions. Mounting The sensing distance for the EE-SPY Reflective-type Photomicrosensor with built-in amplifier varies from 8 to 20 mm depending on the product (90% reflective white paper). Do not place glossy objects in the background of the sensing object. Wiring * Connection is made using a connector. Do not solder to the pins (leads). * When extending the cable, use an extension cable with conductors having a total cross-section area of 0.3 mm2. The total cable length must be 2 m maximum. * To use a cable length longer than 2 m, attach a capacitor with a capacitance of approximately 10 F to the wires as shown below. The distance between the terminal and the capacitor must be within 2 m. (Use a capacitor with a dielectric strength that is at least twice the Sensor's power supply voltage.) 5 to 24 VDC + OUT A capacitor of 10 F min. - 0V Extension cable 2 m max. * Make sure the total length of the power cable connected to the product is less than 10 m even if a capacitor is inserted. 5 EE-SPX301/401 EE-SPY30/40 (Unit: mm) Dimensions Tolerance class IT16 applies to dimensions in this datasheet unless otherwise specified. Sensors EE-SPX301 EE-SPX401 26 20 14 7 Sensing window (1 x 0.5) 3.6 Terminal Arrangement 9 24 (1) (2) Indicator window (red) 18 Vcc OUT (3) OUTPUT GND (0 V) Two, 3.2 dia. 6 3 7.5 (3) (2) (1) 3 3-0.635 1.25 2.5 4.2 5 EE-SPY301 EE-SPY401 26 20 14 7 8 Terminal Arrangement Sensing face (1) 4 20 Indicator window (red) 14 6 (2) Vcc OUT (3) OUTPUT GND (0 V) Two, 3.2 dia. 3 7.5 (3) (2) (1) 3 3-0.635 1.25 2.5 EE-SPY302 EE-SPY402 4.2 5 26 20 14 7 3.5 4 8 Sensing face Terminal Arrangement (1) (2) Indicator window (red) 20 OUTPUT GND (0 V) Two, 3.2 dia. 6 7.5 (3) Vcc OUT 3 (3) (2) (1) 3-0.635 1.25 2.5 3 4.2 5 Accessories (Order Separately) * Refer to Accessories for details. 6 Read and Understand This Catalog Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or comments. Warranty and Limitations of Liability WARRANTY OMRON's exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year (or other period if specified) from date of sale by OMRON. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, REGARDING NON-INFRINGEMENT, MERCHANTABILITY, OR FITNESS FOR PARTICULAR PURPOSE OF THE PRODUCTS. ANY BUYER OR USER ACKNOWLEDGES THAT THE BUYER OR USER ALONE HAS DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE. OMRON DISCLAIMS ALL OTHER WARRANTIES, EXPRESS OR IMPLIED. LIMITATIONS OF LIABILITY OMRON SHALL NOT BE RESPONSIBLE FOR SPECIAL, INDIRECT, OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED ON CONTRACT, WARRANTY, NEGLIGENCE, OR STRICT LIABILITY. In no event shall the responsibility of OMRON for any act exceed the individual price of the product on which liability is asserted. IN NO EVENT SHALL OMRON BE RESPONSIBLE FOR WARRANTY, REPAIR, OR OTHER CLAIMS REGARDING THE PRODUCTS UNLESS OMRON'S ANALYSIS CONFIRMS THAT THE PRODUCTS WERE PROPERLY HANDLED, STORED, INSTALLED, AND MAINTAINED AND NOT SUBJECT TO CONTAMINATION, ABUSE, MISUSE, OR INAPPROPRIATE MODIFICATION OR REPAIR. Application Considerations SUITABILITY FOR USE OMRON shall not be responsible for conformity with any standards, codes, or regulations that apply to the combination of products in the customer's application or use of the products. At the customer's request, OMRON will provide applicable third party certification documents identifying ratings and limitations of use that apply to the products. This information by itself is not sufficient for a complete determination of the suitability of the products in combination with the end product, machine, system, or other application or use. The following are some examples of applications for which particular attention must be given. This is not intended to be an exhaustive list of all possible uses of the products, nor is it intended to imply that the uses listed may be suitable for the products: Outdoor use, uses involving potential chemical contamination or electrical interference, or conditions or uses not described in this catalog. Nuclear energy control systems, combustion systems, railroad systems, aviation systems, medical equipment, amusement machines, vehicles, safety equipment, and installations subject to separate industry or government regulations. Systems, machines, and equipment that could present a risk to life or property. Please know and observe all prohibitions of use applicable to the products. NEVER USE THE PRODUCTS FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY WITHOUT ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE OMRON PRODUCTS ARE PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM. PROGRAMMABLE PRODUCTS OMRON shall not be responsible for the user's programming of a programmable product, or any consequence thereof. Disclaimers CHANGE IN SPECIFICATIONS Product specifications and accessories may be changed at any time based on improvements and other reasons. It is our practice to change model numbers when published ratings or features are changed, or when significant construction changes are made. However, some specifications of the products may be changed without any notice. When in doubt, special model numbers may be assigned to fix or establish key specifications for your application on your request. Please consult with your OMRON representative at any time to confirm actual specifications of purchased products. DIMENSIONS AND WEIGHTS Dimensions and weights are nominal and are not to be used for manufacturing purposes, even when tolerances are shown. PERFORMANCE DATA Performance data given in this catalog is provided as a guide for the user in determining suitability and does not constitute a warranty. It may represent the result of OMRON's test conditions, and the users must correlate it to actual application requirements. Actual performance is subject to the OMRON Warranty and Limitations of Liability. ERRORS AND OMISSIONS The information in this document has been carefully checked and is believed to be accurate; however, no responsibility is assumed for clerical, typographical, or proofreading errors, or omissions. 2012.8 In the interest of product improvement, specifications are subject to change without notice. OMRON Corporation Industrial Automation Company http://www.ia.omron.com/ (c)Copyright OMRON Corporation 2012 All Right Reserved. Mouser Electronics Authorized Distributor Click to View Pricing, Inventory, Delivery & Lifecycle Information: Omron: EE-SPY402 EE-SPY401 EE-SPY301 EE-SPY302