M7100 Pressure Transducer
M7100 www.meas-spec.com March 2015
2/6
PERFORMANCE SPECIFICATIONS
Ambient Temperature: 25°C (unless otherwise specified)
Accuracy (combined linearity, hysteresis & repeatability)
Insulation Resistance (500Vdc)
Frequency Response @ -3dB
Notes
1. Best fit straight line.
2. TEB includes all accuracy errors, thermal errors, span and zero tolerances over the compensated temperature range.
3. Temperature range for product with standard cable is -20°C to +105°C.
4. Between sensor body to any pins of connector.
ENVIRONMENTAL SPECIFICATIONS
Ambient Temperature: 25°C (unless otherwise specified)
Fluids compatible with 17-4PH Stainless Steel
20g, 10 ~ 2000Hz
MIL-STD-810C, Method 514.2, Curve L
Half-Sine, Peak: 50g, 11ms
MIL-STD-202, Method 213B, Condition A
Notes
5. The maximum pressure that can be applied without changing the transducer’s performance or accuracy.
6. The maximum pressure that can be applied to a transducer without rupture of either the sensing element or transducer.
RoHS: RoHS 2 (Directive 2011/65/EU)
UL 508 Certified: Industrial Control Equipment, CSA 22.2 No. 14-10
EMC Performance Criteria: Output Change < ±1.5% FSO
IEC61000-4-2 ESD: 8kV Contact / 15kV Air; Discharge Rate > 10s
IEC61000-4-3 EM Field: 100V/m, 1kHz 80% Modulation, 80 ~ 1000MHz
IEC61000-4-4 Electrical Fast Transient: Level 2, 1KV each line, Capacitance coupling
IEC61000-4-5 Surge: Level 2, 42Ω Impedance, Figure 11 (L-L 500V, L-E 1KV)
IEC61000-4-6 Conducted RF: Level 2, 3V/130dB, 150KHz ~ 80MHz, 2s Dwell, Clamp Injection
IEC61000-4-9 Pulse Magnetic Field: Level 3, 100A/m, 10 Second pulse interval
IEC55022 Emission: Class B, 30dB @ 30-230MHz, 37dB @ 230-1000MHz