3 stage charging
AC 115/230VAC selected by switch
Built-in passive PFC function compliance to EN61000-3-2 Class A (option)
Protection: Short circuit / Reverse polarity / Over voltage / Over temperature
Charger for lead-acid batteries
2 color LED loading indicator
Low cost, High reliability
FAN on/off control(Depends on charging current)
3 years warranty
Features :
P:WithPassivePFC
N:WithoutPassivePFC
PB 360 12
SPECIFICATION
PB-360 -12
MODEL
BOOSTCHARGEVOLTAGE
FLOATCHARGEVOLTAGE
OUTPUTCURRENT(Typ.) Note6
BATTERY TYPE
VOLTAGE ADJUSTABLERANGE
RECOMMENDEDBATTERY
CAPACITY(AMP HOURS) Note5
OUTPUT
VOLTAGERANGE
FREQUENCY RANGE
EFFICIENCY (Typ.)
INPUT
ENVIRONMENT
INRUSHCURRENT (Typ.)
LEAKAGECURRENT
OVERTEMPERATURE
SAFETY STANDARDS
SAFETY &
EMC
(Note4)
WITHSTANDVOLTAGE
ISOLATIONRESISTANCE
WORKINGTEMP.
WORKINGHUMIDITY
STORAGETEMP.,HUMIDITY
TEMP.COEFFICIENT
VIBRATION
OVERVOLTAGE
REVERSEPOLARITY
PROTECTION
ACCURRENT (Typ.)
14.4V
13.6V
24.3A
Open&SealedLead Acid
80~240Ah
13~14.7V
90~132VAC/180~264VACselectedbyswitch 127~187VDC/254~370VDC
47~63Hz
85%
7A/115VAC3.5A/230VAC
COLDSTART 60A
<3.5mA /240VAC
16~18V
Byinternalfuse
Protectiontype: Shutdowno/pvoltage,re-powerontorecover
Protectiontype: Automaticallyderatechargecurrentuntilzero
IEC60335-2-29CBapprovedby TUV(exceptfor48V),UL60950-1approved
CompliancetoEN55022(CISPR22)ClassB, EN61000-3-2,-3(onlyP type)
CompliancetoEN61000-4-2,3,4,5,6,8,11,EN55024,lightindustrylevel,criteria A
I/P-O/P:3KVACI/P-FG:1.5KVACO/P-FG:0.5KVAC
I/P-O/P,I/P-FG,O/P-FG:100MOhms/500VDC /25 /70%RH
-20~+60 (Referto"DeratingCurve")
20~90%RHnon-condensing
-40~+85 ,10~95%RH
0.05%/ (0~45
10~500Hz,2G10min./1cycle,60min.eachalongX, Y,Zaxes
MTBF 115.8Khrsmin.MIL-HDBK-217F(25 )
253*135*48.5mm(L*W*H)
DIMENSIONOTHERS
NOTE
PACKING 1.5Kg;6pcs/10Kg/0.95CUFT
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets
EMC directives.
5. This is Mean Well's suggested range. Please consult your battery manufacturer for their suggestions about maximum charging current limitation.
6. Maximum charging current will be in the range of 90~110% rated output current.
P
PB-360 series
360WSingleOutputBatteryCharger
FUNCTION REMOTECONTROL (CN5) Open:NormalworkShort:StopCharging
(P type only)(except for 48V)
12:14.4V
24:28.8V
48:57.6V
PB-360 -24 PB-360 -48
28.8V 57.6V
27.2V 54.4V
26~28.8V 52~58.6V
12.5A 6.25A
40~125Ah 20~65Ah
86% 87%
31~35V 59~64V
SHORTCIRCUIT O/P Builtinfuse(FS100)toprotectshortcircuitcondition,shutdowno/pvoltageandcannotre-poweron
FileName:PB-360-SPEC2011-08-17
POWERFACTOR(Typ.) >0.65(withP type)at230VAC
EMCIMMUNITY
EMCEMISSION