Millenium 3 logic controllers Type Part number Power supply Inputs Outputs 88970041 24 V c 8 digital (of which 4 are analogue) 4 x 8 A relays 88970042 24 V c 8 digital (of which 4 are analogue) 4 solid state 0.5 A (of which 1 is PWM) With display CD12 CD20 88970043 100 V 240 V a 8 digital 4 x 8 A relays 88970044 24 V a 8 digital 4 x 8 A relays 88970045 12 V c 8 digital (of which 4 are analogue) 4 x 8 A relays 88970051 24 V c 12 digital (of which 6 are analogue) 8 x 8 A relays 88970052 24 V c 12 digital (of which 6 are analogue) 8 solid state 0.5 A (of which 4 are PWM) 88970053 100 V 240 V a 12 digital 8 x 8 A relays 88970054 24 V a 12 digital 8 x 8 A relays 88970055 12 V c 12 digital (of which 6 are analogue) 8 x 8 A relays 88970021 24 V c 8 digital (of which 4 are analogue) 4 x 8 A relays 88970023 100 V 240 V a 8 digital 4 x 8 A relays 88970024 24 V a 8 digital 4 x 8 A relays 88970840 NEW 12 V c 8 digital (of which 4 are analogue) 4 solid state 0.5 A (of which 1 is PWM) 88970031 24 V c 12 digital (of which 6 are analogue) 8 x 8 A relays 88970033 100 V 240 V a 12 digital 8 x 8 A relays 88970034 24 V a 12 digital 8 x 8 A relays Without display CB12 CB20 Millenium 3 logic controllers operate with the following software: M3 SOFT Multilingual programming software (CD-ROM) including a library of specific functions. Part no.: 88970111 Ergonomic display Optimum memory capacity M3 ALARM Alarm management software (CD-ROM) Part no.: 88970116 This software is used alongside the M3MOD communication interface (part no.: 88970117). For all details of hardware adaptation, see pages 64-65. 26 www.millenium3.crouzet.com "Compact" range selection guide Modular power supplies (1) M3MOD STN GSM 12 V DC - 24 W 88970117 88970118 88970119 88950306 b v b v b v v b v v 24 V DC - 7.5 W NEW Starter kits and demo case 24 V DC - 15 W NEW 24 V DC - 30 W NEW 24 V DC - 60 W NEW 88950303 88950304 88950307 88950302 Standard v b b b b 88970080 v b b b b 88970106 (case) 88970081 b v v b v v b b b b b v v b b b b b v v b v v b v v b v v b v v b v v b v v b v v b v v b v v b Compatible v Mounted with the M3MOD: - STN modem, - or GSM modem Millenium 3 Standard Modem communication solutions b 88970082 88970083 b b b b b b b b b b (1) Find the whole "Power Supplies" offer on pages 58-59. The 4 starter kits each contain: 1 CD12 or CD20 logic controller + 1 USB link cable + 1 M3 SOFT programming software application (CD-ROM) including a library of specific functions. Part no.: 88970080 / 88970081 / 88970082 / 88970083 The demonstration case contains: www.millenium3.crouzet.com 1 CD12 logic controller + 1 USB link cable + 1 M3 SOFT programming software application (CD-ROM) including the library of specific functions + 1 voltage adaptor + 1 I/O simulation card. Part no.: 88970106 27 Millenium 3 Standard "Compact" range with display Budget solution with display Memory: 120 lines in LADDER language and up to 350 "typical" blocks in FBD language LCD with 4 lines of 18 characters and configurable backlighting Selective parameter setting: You can choose the parameters that can be adjusted on the front panel or 0-20 mA/Pt 100 with converters (see page 50) Analogue inputs 0-10 V CD20 CD12 Part numbers Type CD12 Input 8 digital (including 4 analogue) 8 digital (including 4 analogue) 8 digital 8 digital 8 digital (including 4 analogue) 12 digital (including 6 analogue) 12 digital (including 6 analogue) 12 digital 12 digital 12 digital (including 6 analogue) CD20 Output 4 relays 8 A 4 solid state 0.5 A (including 1 PWM) 4 relays 8 A 4 relays 8 A 4 relays 8 A 8 relays 8 A 8 solid state 0.5 A (including 4 PWM) 8 relays 8 A 8 relays 8 A 8 relays 8 A Supply 24 V 24 V 100 240 V 24 V 12 V 24 V 24 V 100 240 V 24 V 12 V Code 88970041 88970042 88970043 88970044 88970045 88970051 88970052 88970053 88970054 88970055 Accessories Type M3 SOFT PA Description Multilingual programming software containing specific library functions (CD-ROM) EEPROM memory cartridge 3 m serial link cable: PC Millenium 3 3 m USB link cable: PC Millenium 3 Millenium 3 Bluetooth interface (class A 10 m) Code 88970111 88970108 88970102 88970109 88970104 Starter kits (see page 27 for details) Type Kit 12 Input 8 digital (including 4 analogue) 8 digital 12 digital (including 6 analogue) 12 digital Kit 20 Output 4 relays 4 relays 8 relays 8 relays Supply 24 V 100 240 V 24 V 100 240 V Code 88970080 88970081 88970082 88970083 Dimensions (mm) CD12 CD20 71,2 124,6 113,3 1 2 1 2 - 1 + 2 1 2 90 35 100 90 OK A B ESC - + OK 107,6 ESC 27,5 B 27,5 A 107,6 35 100 27,5 27,5 59,9 58 68 58 68 Input / Output Connections See Page 40-43 for details or to find instruction sheets visit: www.millenium3.crouzet.com in "Download" For adapted products, see page page 64-65 28 www.millenium3.crouzet.com "Compact" range without display Simply a control system solution inside a modular casing Memory: 120 lines in LADDER language and up to 350 "typical" blocks in FBD language No display or parameter-setting buttons to avoid tampering by unauthorised users or 0-20 mA/Pt 100 with converters (see page 50) Analogue inputs 0-10 V CB12 CB20 Part numbers Input 8 digital (including 4 analogue) 8 digital 8 digital 8 digital (including 4 analogue) 12 digital (including 6 analogue) 12 digital 12 digital CB20 Output 4 relays 8 A 4 relays 8 A 4 relays 8 A 4 solid state 0.5 A (including 1 PWM) 8 relays 8 A 8 relays 8 A 8 relays 8 A Supply 24 V 100 240 V 24 V 12 V 24 V 100 240 V 24 V Code 88970021 88970023 88970024 88970840 88970031 88970033 88970034 Millenium 3 Standard Type CB12 Accessories Type M3 SOFT PA Description Multilingual programming software containing specific library functions (CD-ROM) EEPROM memory cartridge 3 m serial link cable: PC Millenium 3 3 m USB link cable: PC Millenium 3 Millenium 3 Bluetooth interface (class A 10 m) Code 88970111 88970108 88970102 88970109 88970104 Dimensions (mm) CB12 CB20 71,2 124,6 113,3 2 1 2 1 2 1 2 90 107,6 35 27,5 100 90 27,5 1 107,6 35 100 27,5 27,5 59,9 57,5 67,5 57,5 67,5 Input / Output Connections See Page 40-43 for details or to find instruction sheets visit: www.millenium3.crouzet.com in "Download" For adapted products, see page page 64-65 www.millenium3.crouzet.com 29 Millenium 3 logic controllers Type Part number Power supply Inputs Outputs With XD10/ XD26 display Without display XB10/XB26 88970141 88970131 NEW 24 V c 88970132 NEW 24 V c 6 digital (of which 4 are analogue) 4 x 8 A relays 88970133 NEW 100 V 240 V a 88970134 NEW 24 V a 6 digital 4 x 8 A relays 6 digital 4 x 8 A relays 88970151 NEW 24 V c 88970152 NEW 24 V c 16 digital (of which 6 are analogue) 10 relays, of which 8 are 8 A and 2 are 5 A 88970142 88970143 88970144 88970161 88970162 88970163 88970164 88970165 88970814 NEW 6 digital (of which 4 are analogue) 4 solid state 0.5 A (of which 1 is PWM) 16 digital (of which 6 are analogue) 10 solid state 0.5 A (of which 4 are PWM) 88970153 NEW 100 V 240 V a 88970154 NEW 24 V a 88970155 NEW 12 V c 12 V c 16 digital 10 relays, of which 8 are 8 A and 2 are 5 A 16 digital 10 relays, of which 8 are 8 A and 2 are 5 A 16 digital (of which 6 are analogue) 10 relays, of which 8 are 8 A and 2 are 5 A 16 digital (of which 6 are analogue) 10 solid state 0.5 A (of which 4 are PWM) Extensions "Sandwich" Type Part number Power supply Inputs Outputs TOR Via the 24 V c controller 6 digital 4 x 5 A relays, 1 of which is a changeover relay 88970323 100 V 240 V a 6 digital 4 x 5 A relays, 1 of which is a changeover relay 88970324 24 V a 6 digital 4 x 5 A relays, 1 of which is a changeover relay Part number Power supply Mains Characteristics of exchanges (words) XN05 88970270 Via the 24 V c controller Modbus TCP Ethernet protocol XN03 88970250 Via the 24 V c controller Modbus RS-485 (slave) Modbus RS-485 (slave) Read: 8 - Read/Write: 8 Clock: 4 - Status: 1 Read: 8 - Read/Write: 8 Clock: 4 - Status: 1 Read: 8 - Read/Write: 8 Clock: 4 - Status: 1 XE10 88970321 Type Communication XN06 88972250 NEW Via the 24 V c controller Millenium 3 logic controllers operate with the following software: M3 SOFT Multilingual programming software (CD-ROM) including the library of specific functions. Part no.: 88970111 M3 ALARM Alarm management software (CD-ROM) Part no.: 88970116 This software is used alongside the M3MOD communication interface (part no.: 88970117). For all details of hardware adaptation, see pages 64-65. 30 www.millenium3.crouzet.com "Expandable" range selection guide Modular power supplies (1) M3MOD STN GSM 12 V DC - 24 W 88970117 88970118 88970119 88950306 b v b v b v v 24 V DC - 7.5 W NEW Starter kits 24 V DC - 15 W NEW 24 V DC - 30 W NEW 24 V DC - 60 W NEW 88950303 88950304 88950307 88950302 v b b b b v b b b b b v v b v v b b b b b v v b b b b b v v b v v b v v b b v v b b Compatible v Mounted with the M3MOD: - STN modem, - or GSM modem Expandable Millenium 3 Standard Modem communication solutions 88970084 88970085 (1) Find the whole "Power Supplies" offer on pages 58-59. Termination extensions Type Part number Power supply Inputs Outputs Digital Via the 24 V c controller 4 digital 2 x 8 A relays 88970213 Via the 100 V 240 V a controller 4 digital 2 x 8 A relays 88970214 Via the 24 V a controller 4 digital 2 x 8 A relays 88970215 Via the 12 V c controller 4 digital 2 x 8 A relays XR10 88970221 Via the 24 V c controller 6 digital 4 x 8 A relays 88970223 Via the 100 V 240 V a controller 6 digital 4 x 8 A relays 88970224 Via the 24 V a controller 6 digital 4 x 8 A relays 88970225 Via the 12 V c controller 6 digital 4 x 8 A relays XR14 88970231 Via the 24 V c controller 8 digital 6 relays, of which 4 are 8 A and 2 are 5 A 88970233 Via the 100 V 240 V a controller 8 digital 6 relays, of which 4 are 8 A and 2 are 5 A 88970234 Via the 24 V a controller 8 digital 6 relays, of which 4 are 8 A and 2 are 5 A 88970235 Via the 12 V c controller 8 digital 6 relays, of which 4 are 8 A and 2 are 5 A XA04 88970241 Via the 24 V c controller 1 analogue (0-10 V/0-20 mA), 1 analogue (0-10 V/0-20 mA/Pt100) 2 analogue (0-10 V)/PWM XR06 88970211 Analogue The 2 starter kits each contain: 1 XD26 logic controller + 1 USB link cable + 1 M3 SOFT programming software application (CD-ROM) including a library of specific functions. Part no.: 88970084 / 88970085 www.millenium3.crouzet.com 31 Millenium 3 Standard "Expandable" range with display "High-performance" expandable solution with display Extended memory: 120 lines in LADDER language and up to 700 "typical" blocks in FBD language LCD with 4 lines of 18 characters and configurable backlighting Selective parameter setting: You can choose the parameters that can be adjusted on the front panel or 0-20 mA/Pt 100 with converters (see page 50) Open to XN network communication extensions and digital I/O or analogue extensions XD10 Analogue inputs 0-10 V XD26 Part numbers Type XD10 Input 6 digital (including 4 analogue) 6 digital (including 4 analogue) 6 digital 6 digital 16 digital (including 6 analogue) 16 digital (including 6 analogue) 16 digital 16 digital 16 digital (including 6 analogue) 16 digital (including 6 analogue) XD26 Output 4 relays 8 A 4 solid state 0.5 A (including 1 PWM) 4 relays 8 A 4 relays 8 A 10 relays (8 x 8 A relay and 2 x 5 A relay) 10 solid state 0.5 A (including 4 PWM) 10 relays (8 x 8 A relay and 2 x 5 A relay) 10 relays (8 x 8 A relay and 2 x 5 A relay) 10 relays (8 x 8 A relay and 2 x 5 A relay) 10 solid state 0.5 A (including 4 PWM) Supply 24 V 24 V 100 240 V 24 V 24 V 24 V 100 240 V 24 V 12 V 12 V Code 88970141 88970142 88970143 88970144 88970161 88970162 88970163 88970164 88970165 88970814 Accessories Type M3 SOFT PA Description Multilingual programming software containing specific library functions (CD-ROM) EEPROM memory cartridge 3 m serial link cable: PC Millenium 3 3 m USB link cable: PC Millenium 3 Millenium 3 Bluetooth interface (class A 10 m) Code 88970111 88970108 88970102 88970109 88970104 Starter kits (see page 31 for details) Type Kit 26 Input 16 digital (including 6 analogue) 16 digital Output 10 relays (8 x 8 A relay and 2 x 5 A relay) 10 relays (8 x 8 A relay and 2 x 5 A relay) Supply 24 V 100 240 V Code 88970084 88970085 Dimensions (mm) XD10 XD26 71,2 124,6 113,3 1 2 1 2 - 1 + 2 1 2 90 35 100 90 OK A B ESC - + OK 107,6 ESC 27,5 B 27,5 A 107,6 35 100 27,5 27,5 59,9 58 68 58 68 Input / Output Connections See Page 40-43 for details or to find instruction sheets visit: www.millenium3.crouzet.com in "Download" For adapted products, see page page 64-65 32 www.millenium3.crouzet.com Millenium 3 Standard "Expandable" range without display "High-performance" expandable solution without display Extended memory: 120 lines in LADDER language and up to 700 "typical" blocks in FBD language No display or parameter-setting buttons to avoid tampering by unauthorised users or 0-20 mA/Pt 100 with converters (see page 50) Open to XN network communication extensions and digital I/O or analogue extensions Analogue inputs 0-10 V XB10 XB26 Part numbers Input 6 digital (including 4 analogue) 6 digital (including 4 analogue) 6 digital 6 digital 16 digital (including 6 analogue) 16 digital (including 6 analogue) 16 digital 16 digital 16 digital (including 6 analogue) XB26 Output 4 relays 8 A 4 solid state 0.5 A (including 1 PWM) 4 relays 8 A 4 relays 8 A 10 relays (8 x 8 A relay and 2 x 5 A relay) 10 solid state 0.5 A (including 4 PWM) 10 relays (8 x 8 A relay and 2 x 5 A relay) 10 relays (8 x 8 A relay and 2 x 5 A relay) 10 relays (8 x 8 A relay and 2 x 5 A relay) Supply 24 V 24 V 100 240 V 24 V 24 V 24 V 100 240 V 24 V 12 V Code 88970131* 88970132 88970133* 88970134 88970151 88970152 88970153 88970154 88970155 Millenium 3 Standard Type XB10 *Available 2nd quarter of 2008 General characteristics See page 22, except: Certifications UL, CSA Accessories Type M3 SOFT PA PA PA PA Description Multilingual programming software containing specific library functions (CD-ROM) EEPROM memory cartridge 3 m serial link cable: PC Millenium 3 3 m USB link cable: PC Millenium 3 Millenium 3 Bluetooth interface (class A 10 m) Code 88970111 88970108 88970102 88970109 88970104 Dimensions (mm) XB26 XB10 124,6 113,3 71,2 1 2 1 2 1 2 1 2 90 107,6 35 27,5 100 90 107,6 27,5 35 100 27,5 27,5 59,9 57,5 67,5 57,5 67,5 Input / Output Connections See Page 40-43 for details or to find instruction sheets visit: www.millenium3.crouzet.com in "Download" For adapted products, see page 64-65 www.millenium3.crouzet.com 33 Millenium 3 Standard Sandwich communication extensions for XD10/XB10 & XD26/XB26 Exchange of input/output state or of internal values via communication networks Power supply via the controller XN06 XN03 XN05 Part numbers Type XN03 XN06 XN05 Description Modbus RS-485 slave communication extension 4 words Modbus RS-485 slave communication extension 8 words Ethernet protocol TCP Modbus extension Supply Via the 24 V Via the 24 V Via the 24 V controller controller controller Code 88970250 88972250 88970270 Characteristics of communication extensions General characteristics 88970250 & 88972250 See page 22, except: Certifications 88970270 UL, CSA, GL (UL, CSA: 88972250) Earthing Yes, refer to the quick reference guide supplied with the product -20 +55C (+40C in a non-ventilated enclosure) in accordance with IEC/EN 600682-1 and IEC/EN 60068-2-2 Maximum length of the network: 1000 m (9600 Baud max, AWG26) Operating temperature Cable length Communication parameters 88970250 & 88972250 Type of link Transmission rate (Bauds) 88970270 2 or 4-wire; RTU or ASCII 1200, 2400, 4800, 9600, 19200, 28800, 38400, 57600 None; even; odd 1 247 Parity Addressing Characteristics of exchanges 88970250 UL, CSA GL pending Yes, refer to the quick reference guide supplied with the product 0 +55C (+40C in a non-ventilated enclosure) in accordance with IEC 60068-2-1 and IEC 60068-2-2 Maximum length between 2 controllers: 100 m 88972250 Static or dynamic 88970270 Programming with Ladder language Image of smart relay I/O Status 4 1 4 1 - 4 4 4 1 8 8 12 1 8 8 4 1 Programming with FBD language Read Read/Write Clock words Status words Dimensions (mm) XN03 - XN05 - XN06 10 70 57 52,5 90 108 35 27,5 100 27,5 35 25 15 44 For adapted products, see page 64-65 34 www.millenium3.crouzet.com Digital sandwich extension for XD10/XB10 and XD26/XB26 Can be used to reach up to 50 inputs/outputs in conjunction with XR14 termination extensions Relay outputs one of which is a changeover relay XE10 Part numbers Input 6 digital 6 digital 6 digital Output 4 relays 5 A (1 of which is a changeover relay) 4 relays 5 A (1 of which is a changeover relay) 4 relays 5 A (1 of which is a changeover relay) Supply Via the 24 V 100 240 V 24 V controller Code 88970321 88970323 88970324 Millenium 3 Standard Type XE10 Dimensions (mm) XE10 90 107,6 27,5 35 100 27,5 72 60 57,4 70 Input / Output Connections See Page 40-43 for details or to find instruction sheets visit: www.millenium3.crouzet.com in "Download" For adapted products, see page page 64-65 www.millenium3.crouzet.com 35 Millenium 3 Standard Digital extension for XD10/XB10 and XD26/XB26 Power supply via the controller at the same voltage as the inputs Number of inputs/outputs can be configured in accordance with your requirements XR06 XR10 XR14 Part numbers Type XR06 Input 4 digital 4 digital 4 digital 4 digital 6 digital 6 digital 6 digital 6 digital 8 digital 8 digital 8 digital 8 digital XR10 XR14 Output 2 relays 8 A 2 relays 8 A 2 relays 8 A 2 relays 8 A 4 relays 8 A 4 relays 8 A 4 relays 8 A 4 relays 8 A 6 relays (4 x 8 A relay 6 relays (4 x 8 A relay 6 relays (4 x 8 A relay 6 relays (4 x 8 A relay Supply Via the 24 V controller Via the 100 240 V controller controller Via the 24 V controller Via the 12 V Via the 24 V controller Via the 100 240 V controller Via the 24 V controller Via the 12 V controller Via the 24 V controller controller Via the 100 240 V Via the 24 V controller controller Via the 12 V and 2 x 5 A relay) and 2 x 5 A relay) and 2 x 5 A relay) and 2 x 5 A relay) Code 88970211 88970213 88970214 88970215 88970221 88970223 88970224 88970225 88970231 88970233 88970234 88970235 Dimensions (mm) XR06 XR10 - XR14 35,5 27,5 25 90 107,6 27,5 35 100 90 107,6 35 100 27,5 27,5 72 60 57,4 70 57,4 70 Input / Output Connections See Page 40-43 for details or to find instruction sheets visit: www.millenium3.crouzet.com in "Download" Analogue extension for XD10/XB10 and XD26/XB26 Direct connection of analogue 0-10 V or 0-20 mA or Pt 100 inputs (10 bits) can be configured using the M3 SOFT 2 analogue 0-10 V or PWM outputs (10 bits) can be configured using the M3 SOFT software Ramp can be parameterised for outputs used as 0-10 V outputs Power supply via the controller XA04 Part numbers Type XA04 Input 1 analogue (0-10 V / 0-20 mA), 1 analogue (0-10 V / 0-20 mA / Pt100) Output 2 analogue (0-10 V) / PWM Supply Via the 24 V controller Code 88970241 For adapted products, see page page 64-65 36 www.millenium3.crouzet.com Characteristics of analogue extension 88970241 General characteristics of analogue extension 88970241 See page 22, except: Certifications UL, CSA GL (pending) Yes, refer to the quick reference guide supplied with the product Earthing Inputs used as analogue inputs Input Input range Input impedance Maximum non destructive current/voltage Value of LSB Input type Resolution Conversion time Accuracy at 25C Accuracy at 55C Isolation between analogue channel and power supply Longueur cable Protection against polarity inversions 0-10 V IP and IQ 0 10 V 18 k 30 V 9.8 mV Common mode 10 bits Module cycle time 1% 1% None 0-20 mA IP and IQ 0 20 mA 246 30 mA 20 A Common mode 10 bits Module cycle time 1% 1% None Pt 100 IQ -25 125C 0.15C Pt 100 probe - IEC 751 - 3-wire 10 bits Module cycle time 1.5C 1.5C None 10 m maximum, with shielded cable (sensor not isolated) Command ignored 10 m maximum, with shielded cable (sensor not isolated) Command ignored 10 m maximum, with shielded cable (sensor not isolated) Command ignored Analogue outputs Range output Input type Max. load Value of LSB Resolution Conversion time Accuracy at 25C Accuracy at 55C Repeat accuracy at 55 C Isolation between analogue channel and power supply Cable length Protection against polarity inversions 0 10 V Resistive 10 mA 10 mV 10 bits Controller cycle time 1% of full scale 1% of full scale 1% None 10 metres maximum, with shielded cable (sensor not isolated) Yes PWM Range output Max. load PWM cyclic ratio Frequency Accuracy Built-in protections V power supply 1.2 k (I 20 mA) 1024 steps 78 Hz, 312.5 Hz, 666.6 Hz, 1000 Hz, 1250 Hz, 1428 Hz, 1666 Hz, 2000 Hz 1% across the entire temperature range for PWM ratios from 5% to 95% Against overvoltages: Yes Dimensions (mm) XA04 90 107,6 35 27,5 100 27,5 35,5 25 57,4 70 Input / Output Connections See Page 40-43 for details or to find instruction sheets visit: www.millenium3.crouzet.com in "Download" For adapted products, see page page 64-65 www.millenium3.crouzet.com 37 Millenium 3 Standard Analogue inputs Millenium 3 Standard Modem communication plug and play solutions For remote control of your application Automatic notification of alarms via SMS (GSM Modem) / email or on a PC with M3 ALARM software. Millenium 3 program can be downloaded, modified and sent Input and output states, as well as all program values, can be polled and controlled remotely 2 types of pre-configured ready-to-use modem: - STN modem for wired transmission networks - GSM modem for wireless communication M3MOD STN GSM Part numbers Type M3MOD STN GSM Description Modem communication interface STN modem GSM modem 850/900/1800/1900 MHz Supply 12-24 V 12-24 V 12-24 V Code 88970117 88970118 88970119 Description 1.80 m serial link cable: DB9/DB9 Alarm management software (CD-ROM) Code 88970123 88970116 Accessories Type PA M3 ALARM Characteristics of the communication Modem system General characteristics of the modem communication 88970117 88970118 88970119 See page 22, except: Certifications UL, CSA UL, CSA UL, CSA, CE, FCC, IC, PTCRB, R&TTE Power supply 88970117 88970118 88970119 Nominal voltage (V) Operating limits 12 24 V -13% / + 20% or 10 28.8 V 5% max. 30 mA 30 mA 550 mA 1.1 W 1 ms, repetition 20 times Yes 1 A fuse 12 24 V -13% / + 5% or 10 30 V 140 mA 70 mA 9600 mA No - 12 24 V -54% / + 33% or 5.5 32 V 165 mA 87 mA 2100 mA at 5.5 V 2.1 W No With fuse 2.5 A Ripple Nominal current under 12 V DC Nominal current under 24 V DC Peak current on energisation Max. absorbed power Immunity from micro power cuts Protection against polarity inversions Fuse protection Characteristics of the "COM-M3" link with the controller Type of connector Type of link Compatibility Isolation of "Com-M3" connector from the "Com-M" connector Isolation of "Com-M3" connector from the supply terminals Specific Millenium Specific Millenium communication protocol Only with Millenium controllers version V2.1 Via optocoupler 1780 V Via optocoupler 1780 V Characteristics of the "COM-M3" link with the modem Type of connector Type of link with Modem connector cable Compatibility Analogue RTC modem compatibility GSM modem compatibility Isolation of "Com-M" connector from the Modem Isolation of "Com-M" connector from the supply terminals 38 Specific Millenium RS 232 serial (supplied with the communication interface) Only with Millenium controllers version V2.1 AT commands AT commands Via link cable to Modem (supplied) Via link cable to Modem (supplied) www.millenium3.crouzet.com