LTC Batteries SL-360 Size: AA Standard use and stand-by Performance Data (Typical values for batteries stored at +25 C for one year) 4.0 System Nominal voltage Nominal capacity Nominal current Max. continuous discharge current Anode surface area Lithium content Weight Volume Temperature range 3.5 Lithium Thionyl Chloride 3.6 V 2.4 Ah 2 mA 20 mA 14 cm2 0.65 g 18 g 8 cm3 -55 C ... +85 C Voltage / V 3.0 2.0 0.5 0.0 0.70.3 Capacity to 2 Volts / Ah SL-360/T +0.2 -0.3 50.5-1.5 0.1 3 1 10 3 2.0 5 6 102 Time / h 103 7 1.5 Ah 2.1 Ah 2.4 Ah 2.4 Ah 2.3 Ah 2.1 Ah 1.9 Ah 104 105 4 2 5 1 1.5 1.0 1: 2: 3: 4: 5: 0.5 0.1 +72 C +55 C +25 C 0 C -30 C 1 10 Current / mA 3.17 100 1000 0.15 thick 45 Operating Voltage 3.6 3.4 Voltage / V O 14.7-1.2 3.8 O 0.8 O 0.8 SL-360/P 45 3.2 3.0 5 4 3 2 1 2.8 1: 20 mA 2: 6 mA 3: 2 mA 4: 0.2 mA 5: 0.02 mA 2.6 SL-360/PR SL-360/PT 2.4 10 25 40 55 Temperature / C 70 85 100 3.5 4+0,5 1-0.1 1-0.1 0.2 thick 0.2 thick Available Terminations Catalogue No. SL-360/S SL-360/T SL-360/P SL-360/PR SL-360/PT 11 1 03601 00 11 1 03602 00 11 1 03603 00 11 1 03606 00 11 1 03608 00 Standard Tags Pins Pins radial Polarized tags 10.16 WARNING: Fire, explosion, and severe burn hazard. Do not recharge, disassemble, heat above 100 C, incinerate, or expose contents to water. Any values given here are for informational purposes only. They also depend on actual conditions of use and are not warranties of future performance. Subject to change. PDC13Eng 4+0,5 -50 -35 -20 -5 3.5 4 Available Capacity 0.0 0.01 70.5 2 1: 180 ~20 mA 2: 560 ~6 mA 3: 1.8 k ~2 mA 4: 5.6 k ~0.6 mA 5: 18 k ~0.2 mA 6: 56 k ~0.06 mA 7: 180 k ~0.02 mA 1.5 1.0 SL-360/S + 1 2.5 2.5 O 4.2 Typical Discharge Curves at +25 C 8 Tadiran Batteries GmbH * Industriestr. 22 * 63654 BUDINGEN GERMANY * Tel.: +49 (0)6042 954-0 * www.tadiranbatteries.de