Subminiature Load Cell
Model 11
DESCRIPTION
Model 11 (tension/compression) subminiature load cell is
designed to measure load ranges from 150 g to 1000 lb. With
subminiature dimensions, including diameters from .50 in to 0.75
in and height of 0.38 in, these units are easily incorporated into
systems having limited space.
The model achieves a non-linearity and hysteresis of 0.5 % full
scale respectively and a frequency response of up to 58 kHz. A
balance module is included in the load cell’s lead wire cable for
zero balance, and should not be removed.
FEATURES
• 150gto1000lb
• mV/Voutput
• Subminiaturedesign
• Singlediaphragmconstruction
2Honeywell•SensingandControl
Model 11
PERFORMANCE SPECIFICATIONS
Characteristic Measure
Load ranges7150 g to 1000 lb
Linearity ±0.5 % full scale
Hysteresis ±0.5 % full scale
Non-repeatability ±0.1 % full scale
Tolerance on output
150 g to 500 g 10mV/V(nominal)
Tolerance on output
1000 g to 1000 lb 2mV/V(nominal)
Operation Tension/compression3
Resolution Infinite
Maximum permissible
torque 150 g to 100 lb 4 in-lb
Maximum permissible
torque 250 lb to 1000 lb 20 in-lb
RANGE CODES
Range codes Range
AL 150 g
AN 250 g
AP 500 g
AR 1000 g
AT 5 lb
AV 10 lb
BL 25 lb
BN 50 lb
BR 100 lb
CN 250 lb
CR 500 lb
CV 1000 lb
ELECTRICAL SPECIFICATIONS
Characteristic Measure
Straingagetype
150 g to 500 g
Semiconductor
Straingagetype
1000 g to 1000 lb
Bonded foil
Excitation (calibration) 5Vdc
Insulation resistance 5000mOhm@50Vdc
Bridge resistance (toler-
ance) 150 g to 500 g
500 ohm (nominal)
Bridge resistance (toler-
ance) 1000 g to 1000 lb
350 ohm (nominal)
Zero balance (tolerance) ±3 % of full scale (nominal)
Shuntcalibrationdata Included
Electrical termination (std) 1,83 m [5 ft] cable with balance board4
MECHANICAL SPECIFICATIONS
Characteristic Measure
Maximum allowable load Seetable1
Weight Seetable
Material Stainlesssteel
Deflection @ full scale Seetable
Natural frequency Seetable
WIRING CODES
Cable Unamplied
Red (+) excitation
Black (-) excitation
Green (-) output
White (+) output
MOUNTING DIMENSIONS
Ranges Ø D T H A B
150, 250, 500,
1000 g; 5, 10,
25, 50, 100 lb
12,7
mm
[0.50 in]
#4-40
UNC
7,37 mm
[0.29 in]
4,83 mm
[0.19 in]
4,57 mm
[0.18 in]
250, 500,
1000 lb
19,05
mm
[0.75]
1/4-28
UNF
9,65 mm
[0.38 in]
7,87 mm
[0.31 in]
7,87 mm
[0.31 in]
ENVIRONMENTAL SPECIFICATIONS
Characteristic Measure
Temperature, operating -54°Cto121°C[-65°Fto250°F]
Temperature, compensated 15°Cto71°C[60°Fto160°F]
Temperature effect, zero 0.01 % full scale/°F
Temperature effect, span 0.02 % reading/°F
Honeywell•SensingandControl3
Subminiature Load Cell
DEFLECTIONS AND RINGING FREQUENCIES
Capacity Deection at full
scale (10-3 in)
Ringing frequency
(kHz)
Weight Weight with cable Max. allowable load1
(% FS)
150 g 0.05 10 5 g [0.011 lb] 13 g [0.029 lb] 500
250 g 0.04 14 5 g [0.011 lb] 13 g [0.029 lb] 500
500 g 0.03 22 5 g [0.011 lb] 13 g [0.029 lb] 500
1000 g 0.7 8 5 g [0.011 lb] 13 g [0.029 lb] 150
5 lb 0.6 11 5 g [0.011 lb] 13 g [0.029 lb] 150
10 lb 0.6 17 5 g [0.011 lb] 13 g [0.029 lb] 150
25 lb 0.5 24 5 g [0.011 lb] 13 g [0.029 lb] 150
50 lb 0.5 34 5 g [0.011 lb] 13 g [0.029 lb] 150
100 lb 0.5 48 5 g [0.011 lb] 13 g [0.029 lb] 150
250 lb 0.6 25 19 g [0.041 lb] 27 g [0.06 lb] 150
500 lb 0.7 33 19 g [0.041 lb] 27 g [0.06 lb] 150
1000 lb 1.0 40 19 g [0.041 lb] 27 g [0.06 lb] 150
OPTION CODES
Many range/option combinations are available in
our quick-ship and fast-track manufacture pro-
grams. Please see http://sensing.honeywell.com/
TMsensor-ship for updated listings.
Load
range
150 g, 250 g, 500 g, 1000 g, 5 lb, 10 lb, 25 lb, 50 lb,
100 lb, 250 lb, 500 lb, 1000 lb
Tempera-
ture
compen-
sation
1a. 60 °F to 160 °F
1b. 30 °F to 130 °F
1c. 0 °F to 185 °F
1e. -20 °F to 200 °F5
1f. 70 °F to 250 °F5
Internal
ampliers
2u.Unamplied,mV/Voutput
Electrical
termina-
tion
5 ft integral cable with balance board4
6a. Bendix PTIH-10-6P - (or equivalent) 6 pin (max.
120°C)onendofcable
6e. Integral cable: Teflon
6v. Phoenix connector on end of cable
Electrical
termina-
tion orien-
tation
15d.Connectoronendofcable
Special
calibration
30a. Compressiontestingonly,positiveincompres-
sion
30b. Tension and compression testing only, positive in
tension
30c. Compressiontestingonly,negativeincompres-
sion
Shock and
vibration
44a.Shockandvibrationresistance
SensingandControl
AutomationandControlSolutions
Honeywell
1985 Douglas Drive North
GoldenValley,MN55422USA
+1-815-235-6847
www.honeywell.com/sensing
008637-1-EN IL50 GLO
May 2008
Copyright © 2008 Honeywell International Inc. All rights reserved.
Model 11 Subminiature Load Cell
TYPICAL SYSTEM DIAGRAM
NOTES
1. Allowable maximum loads – maximum load to be applied without
damage.2
2. Without damage - loading to this level will not cause excessive zero
shift or performance degradation. The user must consider fatigue
life for long term use and structural integrity. All structurally critical
applications (overhead loading, etc.) should always be designed
with safety redundant load paths.
3. Standardcalibrationfortension/compressionloadcellsistension
only.
4. A small, 2 in circuit board is included in the cable, 2 ft from the load
cell. Do not remove this board.
5. Only for ranges greater-than-or-equal-to 1000 g.
6. Specicationsmayvarywiththisoption.
7. This unit calibrated to Imperial (non-Metric) units.
Warranty. Honeywell warrants goods of its manufacture as
being free of defective materials and faulty workmanship.
Honeywell’s standard product warranty applies unless agreed
to otherwise by Honeywell in writing; please refer to your
order acknowledgement or consult your local sales office for
specific warranty details. If warranted goods are returned to
Honeywell during the period of coverage, Honeywell will repair
or replace, at its option, without charge those items it finds
defective. The foregoing is buyer’s sole remedy and is in lieu
of all warranties, expressed or implied, including those of
merchantability and tness for a particular purpose. In no
event shall Honeywell be liable for consequential, special, or
indirect damages.
While we provide application assistance personally, through our
literature and the Honeywell web site, it is up to the customer to
determine the suitability of the product in the application.
Specicationsmaychangewithoutnotice.Theinformationwe
supply is believed to be accurate and reliable as of this printing.
However, we assume no responsibility for its use.
FormoreinformationaboutSensingandControlproducts,visit
www.honeywell.com/sensing or call +1-815-235-6847
Email inquiries to info.sc@honeywell.com
WARNING
PERSONAL INJURY
•DONOTUSEtheseproductsassafetyoremergency
stopdevicesorinanyotherapplicationwherefailureof
theproductcouldresultinpersonalinjury.
Failure to comply with these instructions could result in
death or serious injury.
WARNING
MISUSE OF DOCUMENTATION
•Theinformationpresentedinthiscatalogueisfor
referenceonly.DONOTUSEthisdocumentasproduct
installationinformation.
•Completeinstallation,operationandmaintenance
informationisprovidedintheinstructionssuppliedwith
eachproduct.
Failure to comply with these instructions could result in
death or serious injury.